Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Valves”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Factors affecting left ventricular mass regression after aortic valve replacement with stentless valves.

The hemodynamic benefits of using stentless valves for replacement of the human aortic valve have become more well known. These devices are associated with significant decrease in left ventricular (LV) mass and LV remodeling in the early postoperative period. However, no large study has examined patient-related and valve-related factors that may contribute to this phenomenon. This study examined 1,103 patients who underwent aortic valve replacement (AVR) with a stentless porcine valve (Freestyle = 840, SPV = 263). In all cases, a subcoronary implant technique was used. Valve performance was assessed by serial echocardiograms. At 3 years' post-AVR, mean gradient was 6.3+/-5.0 mm Hg, and effective orifice area (EOA) was 2.0+/-0.7 cm2. Indexed EOA was 1.2+/-0.4 cm2/m2. There was an association between indexed EOA and the extent of LV mass regression. At 3 years after surgery, LV mass index (LVMI) was reduced to 76.3% to 78.7% of baseline in patients whose indexed EOA was >0.8 cm2/m2. In contrast, for patients with an indexed EOA that was <0.8 cm2/m2, LVMI at 3 years was 95.5% of baseline (P = .0001). Multiple linear regression models were used to identify parameters that predicted the 3-year LVMI. Baseline LVMI (P<.0001), prior myocardial infarction (P = .0009), male gender (P = .0036), and carotid stenosis (P = .022) were independent predictors of LV mass regression. Valve type, valve size, preoperative New York Heart Association class symptoms, coronary disease, prior bypass surgery, chronic obstructive pulmonary disease, or underlying valve pathology had no effect on LV mass regression. Data indicate that baseline LVMI and patient-prosthetic mismatch have major effects on the extent of LV mass regression post-AVR. Long-term hemodynamic benefits of AVR can be optimized by proper selection of the prosthesis so as to avoid mismatch. Furthermore, because the baseline LVMI affects the extent of regression post-AVR, early intervention may result in more complete resolution of LV mass postoperatively, which may have important prognostic implications.

Aged↗

The Quattro valve and active infective endocarditis of the mitral valve.

BACKGROUND AND AIM OF THE STUDY: Even today, infective endocarditis remains a therapeutic challenge. Active endocarditis at the time of valve implantation is an important risk factor for the development of prosthetic valve infection. This study reports results following implantation of the Quattro valve, a stentless chordally supported quadrileaflet mitral valve made from bovine pericardium. METHODS: The Quattro valve was implanted in seven patients (four females, three males; mean age 34 years) requiring isolated mitral valve replacement for active bacterial endocarditis. All had congestive heart failure; two were in cardiogenic shock. The diagnosis of active endocarditis was based on clinical and echocardiographic findings, together with macroscopic evidence of acute infection at surgery, blood culture or histopathological evidence of valve infection. Postoperatively, all patients received at least four weeks of parenteral antibiotic therapy. RESULTS: Congestive heart failure (and large pedunculated vegetations and mobile septic left atrial thrombi in two patients) prompted early surgical intervention. Patients underwent surgery at a mean of 7 days (range: 1-16 days) after admission. Endocarditis was caused by Gram-positive cocci in all patients except one. At a mean follow up of 15 months (range: 6-24 months) all patients were alive and symptomatically improved. To date, all remain free of prosthetic valve endocarditis, reoperation and thromboembolism. CONCLUSION: The Quattro valve can be implanted safely in patients with acute bacterial endocarditis. The results also reflect the benefit of early surgical intervention in patients with infective endocarditis complicated by congestive heart failure, with or without large vegetations.

Adult↗

Doppler echocardiographic evaluation of St. Jude Medical valves in the tricuspid position: criteria for normal and abnormal valve function.

BACKGROUND: Although this examination for mitral and aortic prosthetic valves has been frequently reported to be available for the early diagnosis of complications, there are few reports on examinations for tricuspid prosthetic valves, particularly the mechanical valve such as the St. Jude Medical (SJM) valve. Furthermore, the criteria for early diagnosis of complications are unknown. The purpose of this study is to evaluate the SJM valve in the tricuspid position by Doppler echocardiography and to analyze valve-related complications. METHODS: Between September 1978 and March 1997, 46 patients underwent tricuspid valve replacements with SJM valves; these cases were evaluated by Doppler echocardiography. We divided the cases into Normal and Complication groups. RESULTS: In the Normal group, peak pressure gradient was 4.2+/-1.5 mmHg and pressure half-time was 123.5+/-22.9 msec. In the Complication group, peak pressure gradient was 12.7+/-3.6 mmHg and pressure half-time was 271.8+/-76.4 msec. In the Complication group, the lowest peak pressure gradient case was 8.0 mmHg and the shortest pressure half-time was 160.0 msec. CONCLUSIONS: We concluded that when the peak pressure gradient is more than 8 mmHg or the pressure half-time is more than 160 msec, there is a possibility of complications. Despite the problems, the absence of any structural change after more than ten years suggests that the SJM valve can be used in the tricuspid position with careful follow-up.

Adult↗

Progression of isolated tricuspid regurgitation late after mitral valve surgery for rheumatic mitral valve disease.

BACKGROUND AND AIMS OF THE STUDY: Severe tricuspid regurgitation (TR) may develop late after mitral valve surgery without significant mitral stenosis, regurgitation and other causes of left heart failure. The study aim was to investigate severe isolated TR late after mitral valve surgery for rheumatic mitral valve disease. METHODS: A total of 208 patients who underwent mitral valve surgery (valve replacement in 121, commissurotomy in 62, valvuloplasty in 25) was investigated. The mean (+/-SD) follow up was 13+/-6 years. Severe isolated TR was defined clinically by elevated venous pressure, and echocardiographically by grade 4+ TR without significant mitral stenosis, regurgitation, other causes of left heart failure, pulmonary hypertension or rheumatic tricuspid valve. RESULTS: Severe isolated TR was identified in 30 patients (14%) at four to 24 years after mitral valve surgery. All patients had atrial fibrillation. Of these patients, 23 had medical treatment and seven had tricuspid valve surgery. Three of the medically treated patients were in NYHA class IV and died from multiple organ failure at three to seven years after severe TR was diagnosed. Among surgically treated patients, four were in NYHA class IV and had postoperative complications (one early death, one late death), while three NYHA class II/III patients had very few postoperative complications. CONCLUSION: Severe isolated TR was detected in 14% of patients after mitral valve surgery. It is important to detect patients with progressive heart failure and to indicate earlier reoperation in order to prevent significant late mortality.

Adult↗

Analysis of velocity in the ascending aorta in humans. A comparative study among normal aortic valves, St. Jude Medical and Starr-Edwards Silastic Ball valves.

To analyze velocity spectral energy distribution in humans, blood velocities were recorded by means of hot-film anemometry at 41 predetermined measurement points in the cross-sectional area of the ascending aorta approximately 6 cm downstream of the aortic valves. Measurements were made in 8 patients with normal aortic valves, in 4 after insertion of a St. Jude Medical (SJM) aortic valve and in 3 after insertion of a Starr-Edwards Silastic Ball (SSB) aortic valve. Data analysis based on Fast Fourier Transform demonstrated that turbulence energy was lower in patients with normal aortic valves than in patients after insertion of an artificial valve in the aortic position and probably more pronounced after SSB valves than after SJM valves. The spatial distribution of the turbulence energy above 100 Hz was more irregular than corresponding laminar velocities previously presented. The VER100 (Velocity Energy Ratio at 100 Hz, i.e. the velocity energy above 100 Hz divided by the total velocity energy) proved useful for evaluating differences in flow disturbances downstream of different aortic valves. The mean VER100 in the three categories of patients were respectively 0.3, 1.4, and 2.1%.

Adult↗

A comparison of aortic valve replacement with viable cryopreserved and fresh allograft valves, with a note on chromosomal studies.

We examined the long-term clinical function and fate of allograft aortic valves, preserved by two differing methods, for aortic valve replacement: (1) fresh allografts stored at 4 degrees C refrigeration (group I) and (2) viable allografts cryopreserved in liquid nitrogen at -196 degrees C (group II). A total of 316 aortic valve replacement operations were performed, 124 in group I (December 1969 to May 1975) and 192 in group II (June 1975 to December 1986). Concomitant surgical procedures (eg, coronary artery bypass grafting and mitral valve replacement) were necessary in 120 operations. The overall immediate 30 day mortality was 6.0% (confident limits 4.6% to 7.7%), and the survival rates were 83% at 4 years and 60% at 15 years. Endocarditis and technical factors concerning reoperation showed no difference between the two groups according to parametric estimates and hazard function analyses. However, there was a marked difference in reoperation for valve degeneration: 23 patients in group I and 0 patients in group II. The freedom from reoperation for valve degeneration at 10 years was 89% for group I and 100% for group II, and at 15 years it was 59% for group I. The hazard function for group I reflected the late rising risk of degeneration. The freedom from thromboembolism of both groups (aortic valve replacement with or without bypass grafting) was 97% at 10 years and 96% at 15 years. Group II explanted valves (operation for technical malalignment reasons) has consistently shown evidence of persisting viability on tissue culture, on metabolic studies, and on histologic appearances. Chromosomal studies have shown the donor origin of these cells. The superior results with the cryopreserved valve is considered to be due to persisting viability, which appears to be the key to durability.

Adult↗

Comparative evaluation of aortic valve replacement with Starr, Björk, and porcine valve prostheses.

Three groups of 100 consecutive patients with aortic valve disease who were operated on between 1974 and 1978 underwent long-term evaluation. There were 100 aortic valve replacements with porcine bioprosthetic valves (group I), 100 with Starr valves (group II), and 100 with Björk valves (group III). There were no significant differences in the preoperative clinical conditions of the patients in the three groups. Cumulative follow-up was 1688 patient-years. Incidence of valve-related death at 8 years was 4 +/- 2.3% in group I, 13 +/- 3.6% in group II, and 13 +/- 3.8% in group III (p less than .05). At 8 years 95 +/- 2.8% of the patients in group I were free of thromboembolism, compared with 81 +/- 4.8% of those in group II and 84 +/- 4.2% of those in group III (p less than .002). The actuarial risk of a reoperation at 8 years was 16 +/- 6% in group I, 5 +/- 2% in group II, and 2 +/- 1.6% in group III (p less than .025 group I vs group III). At 8 years 98 +/- 1.2% of the patients in group I were free of anticoagulant-related complications, compared with 88 +/- 3.8% of those in group II and 86 +/- 3.9% of those in group III (p less than .005). We conclude that at 8 years porcine bioprosthetic valves performed better than mechanical valves, taking into consideration thromboembolism, anticoagulant-related hemorrhage, and valve-related death.

Actuarial Analysis↗

Mitral valve dysfunction resulting from thickening and stiffening of artificial mitral valve chordae.

BACKGROUND: There is little information about changes in mitral valve function caused by thickening and stiffening of artificial chordae during follow-up. Using serial echocardiographic examination, we evaluated thickening and stiffening of artificial chordae and the effect of those changes on mitral valve function. METHODS AND RESULTS: Between November 1986 and November 1993, 40 patients underwent mitral valve repair with artificial chordae using glutaraldehyde-tanned xenograft pericardium (GTXP) or polytetrafluoroethylene suture (PTFE). Seven GTXP patients and 20 PTFE patients underwent serial echocardiographic examination after surgery and were included in the final analysis. Thickening and stiffening of the artificial chonlae were classified according to echocardiographic changes after surgery: grade 1, no change; grade 2, thickening and/or stiffening without impairment of the motion of the mitral valve leaflet; and grade 3, thickening and stiffening that impaired motion of the mitral valve leaflet. The mean follow-ups in patients with GTXP and PTFE were 6.0 and 3.6 years, respectively. During follow-up, there were 2 GTXP patients with grade 2 thickening and stiffening and 4 patients with grade 3. There were 6 PTFE patients with grade 2 thickening and stiffening and 2 patients with grade 3. Grade 3 occurred earlier in GTXP than in PTFE patients (P < .05). Mitral valve area in GTXP patients decreased from 2.5 +/- 0.4 to 2.1 +/- 0.3 cm2 (P < .05); however, mitral valve area in PTFE patients showed no significant change during follow-up (2.1 +/- 0.4 to 2.0 +/- 0.4 cm2, P = NS). CONCLUSIONS: Although mitral valve repair with artificial chordae is useful, more attention should be paid to mitral valve function resulting from thickening and stiffening of artificial chordae.

Adult↗

Aortic valve replacement in elderly women with small aortic roots: comparing sorin pericardial and St. Jude Medical mechanical valves.

After implanting 19mm and 21mm Sorin pericardial aortic valves (AVR) in 35 women over the age of 60 years, it was our clinical impression that these patients had an unduly high incidence of residual valve stenosis. A retrospective comparison of our experience with this valve and the 19mm St. Jude mechanical AVR in a similar group of 26 patients, operated during the same period (October 1987 to July 1994), was carried out. In comparison to the 19mm St. Jude valve, the 19 mm Sorin Pericardial valve was associated with significant residual stenosis in elderly women despite similar body surface areas. This prosthesis/patient mismatch was not eliminated by the use of a 21 mm Sorin pericardial valve. Although the Sorin pericardial valves was associated with a reduced incidence of thromboembolism and anticoagulation related hemorrhage, it had a significantly increased risk of permanent valve related morbidity and mortality. As a result if this experience we have discontinued our use of the Sorin pericardial valve.

Aged↗

The small aortic root and the Medtronic Hall valve: ultrafast computed tomography assessment of left ventricular mass following aortic valve replacement.

BACKGROUND AND AIMS OF THE STUDY: The selection of an appropriate size aortic valve substitute with respect to patient size and life-style, in the presence of a small aortic root, is problematic, and a decision to enlarge the aortic annulus is often arbitrary. An aortic valve substitute-patient mismatch may place an excessive load on the left ventricle resulting in residual left ventricular mass with attendant patient morbidity and mortality. The aim of this study was to assess the adequacy of the Medtronic Hall valve in the small aortic root using ultrafast computed tomography analysis of left ventricular mass. MATERIALS AND METHODS: In 13 patients the smallest Medtronic Hall valves (size 20 and 21; measured internal orifice area of 2.01 cm2 for both) were used to replace the native aortic valve. All patients had aortic stenosis, and left ventricular hypertrophy was established by echocardiography. The mean body surface area was 1.8 +/- 0.2 m2 (range 1.50-2.06 m2) and the mean weight was 75 +/- 15 Kg (range 50-97 Kg). The mean preoperative New York Heart Association functional class was 3.54 +/- 0.5. RESULTS: There was no operative or late mortality. At a mean follow up of 22 months after aortic valve replacement, the mean left ventricular mass index was 89 +/- 11.4 g/m2 (normal left ventricular mass index by ultrafast computed tomography = 97 +/- 14 g/m2) and mean New York Heart Association functional class was 1.6 +/- 0.8 (p (Binomial) = 0.0001 compared to preoperative). Doppler echocardiogram demonstrated a mean gradient across the prosthetic valve of 17 +/- 7 mmHg. There was no trend towards greater left ventricular mass index in patients with greater body surface area or weight. In no patient was the aortic annulus enlarged. CONCLUSIONS: Trends from this preliminary data suggest that implanting the smallest Medtronic-Hall aortic valves (sizes 20 and 21) results in normal left ventricular mass following aortic valve replacement in patients up to a body surface area of 2.06 m2 and provides support for the notion that an aortic annulus enlarging procedure was not necessary in this group of patients.

Adult↗

[A report of two cases of Carpentier-Edwards pericardial mitral valve malfunction due to neointimal overgrowth expanding to valve cusps].

Two cases of Carpentier-Edwards pericardial mitral valve malfunction due to neointimal overgrowth were reported. Case one was a 51-year-old female undergone redo mitral valve replacement at nine years after first operation. Removed valve showed remarkable overgrowth of neointima expanding to the valve cusps. Case two was a 67-year-old male. A valve removed at nine years after first operation and at 1.5 years after recovery of prosthetic valve endocarditis. Removed valve also showed neointimal overgrowth expanding to the valve cusps. Although we experienced only two cases of neointimal overgrowth, these findings were considered being important in durability of Carpentier-Edwards pericardial valve.

Aged↗

[Incidence and concomitant factors of tricuspid valve insufficiency in patients with aortic and mitral valve diseases].

Invasive data about the frequency and associated factors of tricuspid regurgitation in normals and in patients with aortic and mitral valve disease are still rare. Thus, right ventricular biplane angiograms (RAO/LAO projection), the mean pulmonary artery pressure and the presence of atrial fibrillation were analyzed with regard to tricuspid regurgitation in 30 normals and 165 patients with pure mitral regurgitation, mitral stenosis, aortic regurgitation, aortic stenosis, combined mitral valve disease or combined aortic valve disease. Patients with tricuspid stenosis or coronary artery disease were excluded. In 52 of the 195 patients tricuspid regurgitation was present. Tricuspid regurgitation occurred statistically more often in patients with mitral stenosis (33%), mitral regurgitation (48%) or combined mitral valve disease (68%) than in patients with aortic regurgitation (4%) or combined aortic valve disease (3%). In patients with aortic stenosis and in normals tricuspid regurgitation was not present. In patients with combined mitral valve disease, tricuspid regurgitation was more often present than in patients with pure mitral stenosis (p less than 0.002), despite comparable values of the mean pulmonary artery pressure, the right ventricular enddiastolic and endsystolic volume indexes, the right ventricular ejection fraction and the frequency of atrial fibrillation. Only in patients with pure mitral regurgitation tricuspid regurgitation was associated with an elevated mean pulmonary artery pressure (p less than 0.02). Differences in the right ventricular size and function did not occur between normals and patients with mitral or aortic valve disease. Therefore, the mean pulmonary artery pressure, atrial fibrillation and the size and function of the right ventricle are not major determinants for the occurrence of tricuspid regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve↗

Autologous tissue cardiac valve for aortic valve replacement: technical aspects and early results.

BACKGROUND: The known complications of heterograft bioprostheses and homograft valves have renewed the interest in the use of autologous material. A new technique to construct a tissue prosthesis for aortic valve replacement using the patient's pericardium harvested at the time of operation was developed. The glutaraldehyde-tanned pericardium is mounted on a stent requiring no suturing. Intraoperative testing assures adequate valve function. METHODS: The autologous tissue cardiac valve was implanted in 50 patients in the aortic position between March 1994 and May 1995. Echocardiograms were performed in all patients before hospital discharge, at 3 months (41 patients), and at the end of first postoperative year (12 patients). The mean age was 69.8 +/- 5 years (range, 58 to 82 years). Eighty-four percent of patients presented with aortic stenosis and 16% had a combined lesion. Additional cardiac procedures were performed in 21 patients. RESULTS: Aortic cross-clamp time was 72 +/- 19 minutes, and bypass time was 97 +/- 28 minutes. There were three in-hospital deaths, and 2 patients died within the first postoperative year. Predischarge echocardiography demonstrated excellent hemodynamics, with a mean gradient of 20 +/- 8 mm Hg and no or trivial aortic insufficiency in 45 patients. One patient had moderate aortic insufficiency. At first follow-up 36 patients (90%) were in New York Heart Association class I and 4 patients were in class II. Echocardiography showed no evidence of valve failure or degeneration (mean gradient, 17 +/- 5mm Hg; aortic insufficiency = grade 0 [trivial] in 35 patients, grade II in 3 patients, and grade III in 1 patient). Similarly, no degeneration or valve failure with increasing aortic insufficiency was seen in the patients studied at the end of the first postoperative year. CONCLUSIONS: These results demonstrate that an autologous tissue cardiac valve can be manufactured in the operating room without significant additional operating time. Intraoperative testing minimizes the risk of primary failure with aortic insufficiency. Short-term results are encouraging with good hemodynamic performance of the valve and no signs of degeneration. However, long-term durability needs to be demonstrated.

Aged↗

Midterm results after aortic valve replacement with a stentless bioprosthesis aortic valve.

BACKGROUND: It is suggested that a simplified implant model Cryolife-O'Brien (CryoLife International, Kennesaw, GA) offers less satisfactory outcome compared with standard stentless models. This study was conducted to prospectively evaluate the midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis. METHODS: In 1996, a prospective clinical trial using different stentless valves was initiated. From September 1996 through September 2002, 156 consecutive patients with a mean age of 74.5 years underwent aortic valve replacement with the Cryolife-O'Brien porcine stentless bioprosthesis. The predominant aortic valve lesion was stenosis in 128 and insufficiency in 28 cases. Patients have been followed from 2 to 72 months (mean, 42 months). Echocardiography was performed by one echocardiographer preoperatively, intraoperatively, postoperatively at discharge, 2 to 6 months later, and annually thereafter. RESULTS: Sixty percent of patients received a valve 25 mm in diameter or larger; 39% had concomittant coronary bypass grafting. The 30-day operative mortality rate was 6.4%. Ten late nonvalve-related deaths have occurred. Severe aortic insufficiency caused by oversizing leads to early reoperation in 3 patients. The peak and mean systolic gradients decreased significantly during the first 12 months after implantation, p < 0.001, and the effective valve areas increased significantly during this time interval p < 0.001. At 5 years, ten patients have moderate aortic insufficiency. The actuarial survival at 5 years was 88 +/- 3%. The rate for freedom from endocarditis was 100% and for freedom from thromboembolic events was 94%. CONCLUSIONS: Midterm results after aortic valve replacement with the Cryolife-O'Brien stentless bioprosthesis are encouraging. Good hemodynamics have been coupled with low rate of valve-related complications, thus representing a very good alternative to conventional stented bioprostheses.

Aged↗

Systolic aortic valve compression from partial dehiscence of an aortic valve homograft.

Implantation of valve prostheses provide improvement of symptoms and prolongation of life in selected patients with valvular heart disease. Meticulous follow-up of patients after valve surgery is essential as complications of valve failure, valve dehiscence, valve thrombosis, and infection may occur. The major mode of failure of aortic valve homografts is valve regurgitation, which is readily detected by physical examination. We report a case of left ventricular outflow obstruction after implantation of an aortic valve homograft.

Adult↗

Changes in patterns of left ventricular hypertrophy after aortic valve replacement for aortic stenosis and regurgitation with St. Jude Medical cardiac valves.

In this study, we analyzed the extent and pattern of regression of left ventricular (LV) hypertrophy after aortic valve replacement in patients with aortic stenosis (AS) and compared the results with those of another group of patients with aortic regurgitation (AR). Seventy patients who underwent isolated aortic valve replacement were divided into 2 groups. Group 1 was comprised of 29 patients who underwent aortic valve replacement for aortic stenosis, and Group 2 of 41 patients who underwent aortic valve replacement for aortic regurgitation. A third group of 10 healthy subjects served as a healthy control group. Echocardiographic studies were done before the operation and 5 years postoperatively. At follow-up, a significant reduction in the left ventricular mass was found in both groups, but it remained significantly greater than in the healthy control group. The ratio of LV wall thickness to radius (th/r) in Group 1 decreased significantly, and at follow-up it was within the normal value. In Group 2, the th/r ratio increased, and at follow-up it was within the normal value. After aortic valve replacement, the wall thickness remained significantly greater than normal for patients with AS, and the chamber radius remained significantly greater than normal for patients with AR. For these reasons, LV hypertrophy still existed in both groups at postoperative follow-up. The actuarial survival rate was 85.3% at 16 years for Group 1 and 83.4% at 18 years for Group 2. There was no significant difference in the long-term survival rates between the 2 groups. Actuarial freedom from valve-related events was 91.9% at 16 years for Group 1 and 82% at 18 years for Group 2. There was no significant difference in the valve-related event free curves between groups. After 5 years of follow-up, th/r reached normal for both groups, indicating remodeling of the LV geometry after aortic valve replacement.

Adult↗

Current perspective on aortic valve repair and valve-sparing aortic root replacement.

Aortic valve repair and valve-sparing aortic root replacement are attractive concepts because they offer the possibility of valve competence without structural deterioration due to nonviability and they preclude the need for anticoagulation. Enthusiasm for aortic valve repair has waxed and waned over the past 45 years due in part to the inherent technical difficulties and poor mid-term results. Renewed interest in the concept of aortic valve repair has paralleled the development of valve-sparing aortic root replacement over the last 20 years. A current perspective on aortic valve repair and valve-sparing aortic root replacement is presented in the following review. Historical background, indications for repair, technical considerations, and outcomes data are discussed.

Aortic Valve↗

Mitral valve replacement in patients after aortic valve replacement.

BACKGROUND: Mitral valve replacement in patients who previously had undergone aortic valve replacement is a technical challenge. The rigid aortic prosthesis limits visualization of the anterior mitral annulus and placement of sutures. METHODS: Reoperative mitral valve replacement was performed in five patients after aortic valve replacement. Two patients underwent resternotomy to allow verification of normal aortic prosthetic valve function. Anterolateral right thoracotomy was used for reentry in the remaining three patients. Exposure of the anterior mitral annulus was accomplished by initial traction on the intact anterior leaflet, with resection of this leaflet only after placement of sutures. RESULTS: All patients survived the surgical procedure and are well 2 to 30 months after operation. In one patient it was impossible to open one cusp of the mitral prosthesis, nor was it possible to rotate the valve. The valve was reimplanted, but sutures were tied only after testing for full free cusp motion. CONCLUSIONS: When appropriate, right thoracotomy incision offers excellent exposure of the mitral valve with minimal dissection. Placement of sutures along the anterior portion of the annulus is facilitated by traction downwards on the anterior leaflet. Full range of motion of the prosthetic cusps should be verified before tying the sutures.

Aged↗