Arthroscopy after dysfunctional total knee arthroplasty: two cases with peg fracture of the polyethylene insert.

Arthroscopy may be indicated in patients with painful dysfunction of the knee joint following total joint replacement. Arthrofibrosis, impacted soft tissue, patellar malalignment, synovialitis, and intra-articular foreign bodies can be treated with the promise of a good outcome. Two cases of peg fracture of the polyethylene insert of a semiconstrained knee prosthesis are presented. In relation to fracture position, instability and locking-up of the joint were clinically manifest. When arthroscopy is used judiciously, its merits are found in ensuring the proper diagnosis and in the reliable planning of treatment. When the patient reports locking-up of the joint, the rare complication of a polyethylene peg fracture must be considered.

Arthroplasty, Replacement, Knee↗

Patient satisfaction and outcome after septic versus aseptic revision total knee arthroplasty.

A consecutive series of revision total knee arthroplasties performed at 3 university-affiliated centers by 3 surgeons was prospectively studied. The same implant was used in all cases. The evaluation included a Knee Society clinical score (KSCS); SF-36; satisfaction survey; and radiographs preoperatively, at 6 and 12 months postoperatively, and annually thereafter. Follow-up averaging 36 months (range, 24-60 months) was obtained in 125 of 138 knees (91%). Twenty-eight knees were infected, and 26 of 28 knees were treated successfully with 2-stage exchange with an interval of 4 to 6 weeks using an antibiotic-impregnated spacer block and intravenous antibiotics. The remaining 99 knees were revised for reasons other than infection, including aseptic component loosening, progressive osteolysis, and component instability. Preoperatively, patients with infection had a significantly decreased arc of motion compared with patients without infection (79 degrees vs 92 degrees; P<.05). There was a strong trend for the infected knees to have a lower preoperative KSCS than the noninfected knees, although this trend did not achieve statistical significance (76 vs. 92; P =.11). Postoperatively, patients with infection continued to have a significantly decreased range of motion (89 degrees vs. 99 degrees; P =.05). The postoperative KSCS was markedly lower in the septic versus aseptic revisions (115 vs. 135; P =.02). Patients with infection had a significantly lower function score (44 vs. 57; P =.03). A significantly higher percentage of patients stated that they were unable to return to normal activities of daily living after septic versus aseptic revision total knee arthroplasty (24% vs. 7%; P<.05). Despite the inferior functional result, patients expressed an equal degree of satisfaction with the results of their treatment in septic versus aseptic revision cases.

Aged↗

Ultrasound for diagnosis of infection in revision total hip arthroplasty.

Eighty consecutive patients (85 hips; 43 women; median age, 74 years [range, 33-90 years]) underwent a revision total hip arthroplasty. Preoperatively and guided by ultrasound, biopsy specimens of the joint pseudocapsule were taken, and joint fluid was aspirated for culture. Capsule morphology was investigated with light microscopy. When septic loosening was defined as 2 intraoperative cultures yielding the same microorganism, the prevalence was 12%. Sensitivity of the capsule biopsy cultures was 67%; specificity, 68%; positive predictive value, 22%; and negative predictive value, 94%. Joint fluid was often sparse and always falsely sterile. One specimen from a hip with septic loosening showed histologic changes (> or =3 foci, each with > or =3 plasma cells/high-power field) consistent with chronic infection. The remaining 8 septic loosenings eluded histologic detection, yielding 11% sensitivity. All aseptic loosenings were classified correctly (specificity 100%). Positive and negative predictive values were 100% and 89%. Ultrasound-guided aspiration and capsule biopsy with cultures and histology does not seem to be sufficiently accurate in the preoperative diagnosis of infected total hip arthroplasty.

Adult↗

Multiple previous surgeries, infection, and preoperative radiation: a cause for arterial rupture in closed reduction?

We report a patient who underwent revision hip arthroplasty with preoperative radiation after a septic loosening of the primary hip prosthesis. Subsequently the patient presented with a dislocation of the hip. During the closed reduction with general anesthesia, a rupture of the arteria profunda femoris occurred. The patient was treated by angiographic obliteration of the arteria profunda femoris followed by an open reduction and augmentation of the acetabular component.

Aged↗

Brucellosis as a cause of septic loosening of total hip arthroplasty.

Infection after a total hip arthroplasty is a severe complication and is associated with a high incidence of morbidity. We describe a case of late infection, 5 years after the implantation of a cemented hip prosthesis. The infection was caused by gram-negative Brucella melitensis and occurred in a 63-year-old man who owned cattle. As far as we know, such a complication has never been published before.

Arthroplasty, Replacement, Hip↗

A technique for treating periprosthetic fractures of the femur associated with deep prosthetic infection.

In this report a case of periprosthetic fracture of the femur associated with deep prosthetic infection after a total hip arthroplasty is treated in a novel way that allows for stabilization of the fracture and the delivery of local antibiotics. The technique allows the surgeon to stabilize the fracture and deliver antibiotics locally with a cement-coated Enders nail. This technique is useful in this combination of difficult problems as it facilitates the goals of eradicating infection, alleviating pain and improving function.

Aged↗

Polyethylene-induced pes anserinus bursitis mimicking an infected total knee arthroplasty: a case report and review of the literature.

Polyethylene-induced pes anserinus bursitis after total knee arthroplasty (TKA) with the clinical manifestations mimicking an infected TKA is a very rare occurrence. We report such a case in a 74-year-old woman. She developed recurrent draining papules on the anterolateral aspect of the knee because of polyethylene-induced chronic pes anserinus bursitis 8 years after TKA. The diagnosis was established with a sinography study and confirmed by histopathologic examination of the surgical specimen. The symptoms were resolved after surgical excision of the lesion. Pes anserinus bursitis should be included in the differential diagnosis in knees with a draining sinus after TKA, and sinogram is considered the best method to establish the diagnosis.

Aged↗

[Results of one-stage endoprosthesis revision in periprosthetic infection cause by methicillin-resistant Staphylococcus aureus].

OBJECTIVE: Are the results of one-stage exchange arthroplasties to treat periprosthetic infection caused by methicillin-resistant Staphylococcus aureus (MRSA) comparable to bacteriologically unselected studies of one-stage exchange operations? METHOD: From 1996 to 1997 twenty patients with a periprosthetic infection caused by methicillin-resistant Staphylococcus aureus (MRSA) were treated at the ENDO-Klinik by an one-stage exchange arthroplasty. Mean follow-up of fifteen one-stage exchange total hip replacements and 5 one-stage exchange total knee replacements was 16 months. The patients were examined by means of clinical, laboratory-chemical and radiological tests. In addition, postoperative joint aspiration was performed on 14 patients. RESULTS: In 11 cases (61%) the periprosthetic infection was treated successfully with only one one-stage exchange operation. In cases with persisting infection the period between the first exchange arthroplasty and the repeated clinical manifestation of the infection (second exchange operation) was 2 months on average. 93% of the joint aspirations (n = 14), performed on average 4 weeks postoperatively, correlated with the result of the follow-up tests. CONCLUSION: Periprosthetic infection with MRSA is a problematic infection. Because of the reduced therapeutic possibilities it is associated with a higher rate of recurrence than the unselected group of patients as a whole [6, 11, 16, 17, 19, 20]. The authors recommend one-stage exchange arthroplasty using a combination of vancomycin and ofloxacin as admixture to polymethylmethacrylat (Refobacin Palacos R). This procedure does, however, need further development. Intraoperative use of an antiseptic and systemic administration of rifampicin, as recommended by Zimmerli [23] is a further possibility.

Aged↗

[Staged diagnosis of septic hip endoprosthesis loosening with laboratory parameters and antigranulocyte scintigraphy].

AIM: The value of serial diagnosis of septic loosening of hip endoprosthesis using laboratory parameters and antigranulocytes scintigraphy was investigated and compared to joint aspiration. METHOD: In 35 patients with intraoperative verification of infection, we calculated sensitivity, specify and prevalence dependent positive and negative predictive values for antigranulocyte scintigraphy, laboratory tests and the most suitable combination of both. We also calculated predictive values of joint aspiration using sensitivity and specify values given in the literature. RESULTS: From negative and positive predictive values, of the sedimetation rate and leukocyte count provided no increase of information. We found the same result for positive predictive values of C-reactive protein. For antigranulocyte scintigraphy alone, we found a distinct but still unsatisfying increase of information. Nevertheless, in both cases infection could be excluded definitely. Therefore, the combination of C-reactive protein and antigranulocyte scintigraphy was suitable and the positive predictive values of this combination were only about 5% lower than those of joint aspiration. But with joint aspiration, infection could not be excluded. CONCLUSION: A positive result in serial diagnosis using C-reactive protein and antigranulocyte scintigraphy leads to an distinct increase in the probability of infection which is comparable to that of joint aspiration. The additional advantages of this procedure are the certain exclusion of infection and the absence of invasiveness.

Aged↗

[First experiences with fluorodeoxyglucose-positron-emission tomography (FDG-PET) in the evaluation of painful total knee and hip joint replacements].

AIM: The aim of the study was to describe first experiences using FDG-PET in the examination of painful arthroplasties. METHOD: 12 patients prior to revision of a total hip or knee joint replacement underwent PET. Histopathology, microbiological analysis and intraoperative diagnosis were compared to preoperative PET findings. RESULTS: The analysis of intraoperative findings, of microbiological examinations and of histopathology showed that besides the well known determinants infection and early postoperative granulation tissue, polyethylene wear induced foreign-body reaction was a major cause for increased FDG consumption. CONCLUSION: In vivo imaging of marked foreign-body tissue reaction induced by polyethylene wear is feasible by FDG-PET. This observation, however, leads to reduced specificity of PET imaging for the diagnosis of periprosthetic infection.

Aged↗

[Limits in cementless hip revision total hip arthroplasty. Midterm experience with an oblong revision cup].

UNLABELLED: Revision of an acetabular component in a patient who has severe periacetabular bone loss is a complex problem, particularly when there is not enough bone stock to allow placement of an acetabular component near the normal anatomical hip center. To fill the defect, a valuable option for revision arthroplasty is the cementless oblong revision cup (LOR). METHODS: 50 consecutive revisions of the acetabular component were performed in 48 patients. The mean age at the time of revision was sixty-one years (range, thirty-three to seventy-eight years). Forty-eight hips were available for follow-up, at a mean of thirty-two months (range, eighteen to sixty-one months). The acetabular defect classified according to Paprosky, the migration and the radiolucencies were followed radiologically. RESULTS: 8 hips (16 %) were revised again: two because of infection (4 %) and six because of instability (12 %). The revised hips are not associated to the preoperative degree of acetabular defect (34 % defect type III) (P > 0.05). The mean Harris Hip score was corrected from 36.5 (range, 7.5 to 92.5) to 78.2 points (range, 47.6 to 97.6) (P < 0.01). The mean d'Aubigné Score was corrected from 8.3 (range, 4 to 6) to 15 points (range, 10 to 18) (P < 0.01). Neither pre- nor postoperative results were associated to the degree of acetabular defect (P > 0.05). However, patients with multiple revisions had a significantly reduced clinical outcome than patients with the first revision (P < 0.05). The hip center of rotation, cranially placed to the contralateral side (0.92 cm) was corrected by the revision to a more normal anatomic rotation center (0.27 cm). Partial zonal radiolucencies, always smaller than 1.5 mm were seen in 30 % of the patients. The mean migration of the acetabular component was not significant (P > 0.05). CONCLUSION: The authors support the use of the cementless oblong revision cup if contact can be made with host bone to more than 50 %. If this is not possible, acetabular bone reconstruction combined with a roof ring and a cemented cup is the component of choice.

Acetabulum↗

[Functional results following Girdlestone arthroplasty].

AIM: Aim of the investigation was to identify prognostic factors predicting the level of postoperative function following Girdlestone ("G")-arthroplasty. METHODS: Data were derived from 87 patients, 90 hips, treated with "G"-arthroplasty at one institution between 1983 and 2000. RESULTS: Hip scores amounted to 38.7 (HHS) and 3.5 (Merle) points. The number of previously implanted total hip arthroplasties (THR) did not correlate with the functional result of "G"-arthroplasty (r = - 0.1400; p = 0.4524). On average, the duration of THR prior to "G"-arthroplasty was 44.6 months. Survival time of the latest THR and function of "G"-arthroplasty did not correlate (r = 0.0705; p = 0.7065). Patient age at primary THR, at follow-up, or at "G"-procedure did not correlate with HHS (r = - 0.0367, p = 0.8418, r = 0.1527, p = 0.4121; r = - 0.0151; p = 0.9356, respectively). Time following "G"-arthroplasty, averaging 90.6 months, did not correlate with patients function (r = 0.0920, p = 0.6289). Revision following "G"-procedure and the presence of diabetes positively correlated (p = 0.0104). The appearance of cement in the femoral canal and radiographic signs of persistent bone infection correlated significantly (p = 0.0572). CONCLUSION: Patient age, duration of "G"-hips, and number of prior THR were not reliable to predict the function of "G"-arthroplasty.

Adult↗

[Infection diagnosis after knee-TEP-implantation].

AIM: In this study, the accuracy of antigranulocyte scintigraphy as a diagnostic means prior to revision in infected total knee replacement was compared to that of preoperative joint aspiration and laboratory parameters. The most efficient combination of all diagnostic methods was calculated and thus a diagnostic algorithm recommended. The value of PCR was compared to commonly used techniques of microbiological culturing. METHODS: Preoperative diagnostic means for infection of 50 total knee replacements in 45 patients requiring revision surgery, were retrospectively analyzed. Inclusion criteria were the intraoperative microbiological and histological verification of infection. Sensitivity, specificity, negative and positive prediction value of C-reactive protein (CRP) and leukocytes, antigranulocyte scintigraphy with (99m)Tc-labeled antibodies, and preoperative joint aspiration were calculated. Furthermore, the accuracy of the different techniques of culturing was compared to that of the polymerase chain reaction (PCR) based on the intraoperative histological findings. Two blinded examiners evaluated specimens taken intraoperatively according to the criteria of Mirra. RESULTS: We observed a sensitivity of 1.0, a specificity of 0.82, a positive prediction value of 0.83 and a negative prediction value of 1.0 for the antigranulocyte scintigraphy. The sensitivity of preoperative joint aspiration was 0.5, the specificity 1.0, and the positive and negative prediction values were 1.0 and 0.5. Correlated to the intraoperative histological findings the accuracy of PCR and culturing was comparable. The highest accuracy was obtained for blood culture samples. CONCLUSION: Compared to preoperative joint aspiration the antigranulocyte scintigraphy proved to be more sensitive in the diagnosis an infected knee replacement while having a high specificity. An advantage of PCR compared to the common microbiological culturing techniques was not observed.

Aged↗

[One-stage revision of shoulder arthroplasty in the case of periprosthetic infection].

AIM: Infection of shoulder arthroplasties is rare, but represents a potentially devastating complication. The aim of this work is to show the value of various diagnostic procedures, specify causative pathogens and present the results of one-stage revised patients. METHOD: We performed a retrospective analysis of our 16 consecutive patients with an infected shoulder arthroplasty. RESULTS: In 13 of 16 cases a causative pathogen could be established preoperatively. Staphylococcus and Propioni spp. dominated. Only 9 patients could be followed up because two died, two were lost and three patients were revised because of non-infectious complications. The follow-up time was 5.8 years (13 months-13.25 years). The Constant-Murley score was 33.6 of 100. Eradication of infection was achieved in all patients. In the follow-up time no reinfection has occurred. CONCLUSION: Culturing of the preoperative joint fluid aspirate and the determination of CRP provide an early diagnosing of shoulder arthroplasty infection. One-stage revision arthroplasty with radical debridement and application of antibiotics to the bone cement provide an accurate therapy of periprosthetic shoulder infection.

Aged↗

[Usefulness of 16S rDNA polymerase-chain-reaction (PCR) in the intraoperative detection of infection in revision of failed arthroplasties].

AIM: In this study the accuracy of the 16S DNA polymerase chain reaction (PCR) in revision arthroplasties was compared to that of conventional bacterial culture when correlated to intraoperative histological findings. Furthermore, the influence of antibiotic treatment and different ways of collecting samples was evaluated. METHOD: In a prospective study we collected samples of tissues, aspiration fluids and swabs during revision arthroplasty surgery and examined them with PCR as well as conventional bacterial culturing methods. Also, we correlated these two methods with the histological findings of intraoperative tissue samples. Two independent examiners evaluated the samples according to the criteria of Mirra et al. Sensitivity, specificity, positive and negative prediction value and the accuracy were calculated for the molecular biological and culture methods. Three groups were defined to evaluate the influence of accompanying antibiotic treatment and the way of collecting the microbiological samples. RESULTS: Nine periprosthetic infections could be detected by PCR as well as by conventional bacterial culturing. Correlated with the 25 positive histological findings this resulted in a sensitivity of 0.36, a specificity of 1.0, a negative prediction value of 0.61, a positive prediction value of 1.0 and an accuracy of 0.68 for both methods. Swabs compared to aspiration fluids and tissues samples showed the highest sensitivity with both methods. No higher sensitivity of PCR compared to conventional bacterial culturing could be observed in patients with accompanying antibiotic treatment. CONCLUSION: Although PCR is more rapidly available for the diagnosis of periprosthetic infection, a definite advantage of this more expensive method could not be demonstrated in view of the same low sensitivity of PCR and conventional bacterial culturing.

Arthroplasty↗

[Systemic spread of wear debris--an in-vivo study].

AIM: The aim of this study was to elucidate whether there is a systemic spread of wear debris from peripherally applied stainless steel and titanium particles into the blood and subsequently to parenchymatous organs. Furthermore, we report on histological findings at the implantation site. METHOD: In Syrian Gold hamsters we implanted 2 mm3 wear debris of stainless steel and titanium into the dorsal skin fold chamber. Over a period of 2 weeks we took blood samples and afterwards explanted the implant area, the heart, lung, liver and spleen. One half of the organs and the implant area were used for histological analysis. The other half of the organs and the blood samples were analysed by optical emission spectrometer with inductively coupled plasma and graphite furnace atomic absorption spectrophotometry for their contents of chromium, nickel and titanium. RESULTS: In the group with titanium particles, histological analysis of the implant site showed moderate phagocyted wear in granulocytes but no other pathological findings. Animals treated with stainless steel wear debris had a massive inflammatory reaction, in some cases leading to necrosis. The analysis of the blood and one half of the organs showed increased levels of chromium and, already 24 hours after implantation, raised values for nickel. The result of the hamsters treated with titanium showed significantly elevated levels of titanium ions in the organs, but not in the blood samples. Histology of the organs did not reveal pathological findings. CONCLUSION: In this study we could show a massive inflammatory reaction for stainless steel wear debris in contrast to titanium wear debris at the implantation site. The elevated blood levels of chromium and increased values of other metals in the organs suggest the haematogenic distribution of ions from the peripherally implanted wear debris.

Animals↗

Fibrous tissue overgrowth and prosthetic valve endocarditis: report of a case.

Mechanical valve stenosis without restricted occluder motion and paravaluvular leakage developed in a patient who had undergone patch closure of partial atrioventricular septal defect and replacement of the left atrioventricular valve 13 years previously. Dense calcification of the supravalvular region was shown in a cineradiogram, whereas transthoracic and transesophageal echocardiography failed to reveal any obstructive mechanism. Elevated transprosthetic pressure gradient with unrestricted occluder motion suggested prosthetic valve stenosis resulting from fibrous tissue overgrowth, although this was not visualized by the modern diagnostic imaging tools. Reoperation confirmed calcified fibrous tissue overgrowth obstructing the mechanical valve inflow. Examination of resected tissue revealed prosthetic valve endocarditis due to alpha-streptococcus. Paravalvular leakage accompanying fibrous tissue overgrowth may indicate the presence of prosthetic valve infection even if the clinical manifestations are scarce.

Calcinosis↗