Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “NAILS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Nail matrix hypergranulosis.

Nail pathology shares some common features with skin pathology, but it also has its own peculiar aspects. The anatomical and physiological characteristics of the nail unit probably play a major role in determining these pathological differences. Although the presence of keratohyaline granules is a normal feature of the skin, there is no granular layer in the normal nail matrix. As a consequence, nail matrix hypergranulosis should be considered a separate entity from skin hypergranulosis. In our review of 150 longitudinal nail biopsy specimens, keratohyaline granules were seen in the nail matrix of 24 cases of lichen planus, 29 cases of spongiotic trachyonychia, 10 cases of psoriasis, and three cases of Hallopeau acrodermatitis. In all cases, the presence of keratohyaline granules was associated with the absence of the normal keratogenous zone. Similar nail matrix features were detectable in three cases of malignant melanoma, two cases of primary systemic amyloidosis, and one case of histiocytoid hemangioma compressing the nail matrix. Our data suggest that inflammatory and compressive insults to the nail matrix cause both disappearance of the keratogenous zone and matrix keratinization with the formation of keratohyaline granules. Skin hypergranulosis reflects a hyperplasia of a normal skin component. In the nail matrix, however, hypergranulosis represents the appearance of structures not normally present. Nail matrix hypergranulosis should be considered a pattern of nail matrix reaction to different inflammatory insults. It is therefore more analogous to epidermal parakeratosis than to epidermal hypergranulosis.

Acrodermatitis↗

Candida onychomycosis--an evaluation of the role of Candida species in nail disease.

Nail infections caused by Candida species are normally associated with chronic paronychia or chronic mucocutaneous candidiasis (CMCC). However, the role of Candida in the pathogenesis of other primary nail dystrophies has been questioned in view of their response to antifungal therapy alone. In the present study of 86 patients with primary nail dystrophies from which Candida was isolated, three patterns of nail involvement were found. Nineteen patients, of whom 17 had CMCC, had total dystrophic onychomycosis of at least two nails. The second group consisted of 27 patients with paronychia and lateral onycholysis. In a further 40 patients, who did not have paronychia, Candida was isolated from nails showing primary distal and lateral onycholysis. These changes were mainly seen in patients with peripheral vascular disease, particularly Raynaud's disease, or Cushing's syndrome. Nail biopsies from patients in the latter two groups confirmed the presence of yeasts and mycelium in the nail plate and 17 (46%) of those receiving antifungal therapy with ketoconazole or itraconazole showed complete clearance of the nail dystrophy. Good responses to therapy were seen more frequently in patients with peripheral vascular disease or Cushing's syndrome of whom 15 (72%) recovered; distal erosion of the nail plate, mycelium in the nail plate on biopsy or direct microscopy together with the isolation of C. albicans were all associated with good responses to antifungals. In addition to patients with CMCC or paronychia, therefore, Candida appears to be a significant pathogen in some patients with primary onycholysis of the finger nails, particularly where there is underlying peripheral vascular disease or Cushing's syndrome.

Adolescent↗

Nail biopsy. Indications and methods.

Nail biopsy is a safe and useful diagnostic procedure for many nail disorders when routine clinical and laboratory methods fail to produce a diagnosis. Prerequisites for nail biopsy are an understanding of the surgical anatomy of the nail, adequate anesthesia and hemostasis, and a nail abnormality for which histopathology can provide the diagnosis. Indications and methods for nail biopsy vary according to the site and type of pathology in the nail unit. Nail bed and perionychial biopsies can be performed easily and with minimal scarring. They are most commonly used to diagnose tumors as well as infectious and inflammatory disorders of the nail. The most important reason to biopsy the nail matrix is to make or exclude the diagnosis of melanoma in a patient with longitudinal melanonychia. Great care must be taken in nail matrix biopsy to minimize the risk of permanent nail dystrophy.

Biopsy↗

Drug-induced nail disorders: incidence, management and prognosis.

A large number of drugs of different classes, ranging from antibacterials to chemotherapeutic agents to psoralens, can be responsible for the development of nail changes. Drug-induced nail changes usually involve several or all 20 nails and appear in temporal correlation with drug intake. Some nail changes are asymptomatic and only cause cosmetic problems, while others cause pain and discomfort and impair manual activities or deambulation. Drug-induced nail abnormalities are usually transitory and disappear with drug withdrawal, but sometimes persist in time. The pathogenesis of the nail changes is usually a toxic effect of the drug on the different nail constituents, but other mechanisms can be involved. Drugs that are well known to produce nail abnormalities include cancer chemotherapeutic agents, psoralens, retinoids, tetracyclines, antimalarials and zidovudine. Arsenic poisoning is also always associated with nail changes that have medico-legal importance. Some drugs taken during pregnancy may impair nail development of the fetus, and nail hypoplasia or other nail dystrophies will be evident in the newborn.

Female↗

Isolated congenital nail dysplasia: a new autosomal dominant condition.

OBJECTIVE: Developmental nail abnormalities are extremely heterogeneous, with hereditary isolated conditions being a small and rare subgroup. An unusual congenital nail dysplasia observed in a large South German kindred was characterized clinically to review the question of uniqueness. DESIGN: Case series of affected family members. SETTING: University department of dermatology and houses of patients. PATIENTS: The history and clinical features in 22 affected family members (13 females and 9 males, aged 5 to 74 years) were recorded and documented by photographs. Nail biopsy samples were taken from 2 patients. INTERVENTIONS: None. RESULTS: The pedigree spanning 5 consecutive generations was best compatible with autosomal dominant inheritance with complete penetrance. Nail alterations were mostly present since birth and soon reached an individually variable degree of severity. Affected persons showed longitudinal streaks and thinning of nail plates, mostly of all fingernails and toenails, with some accentuation of the thumbnail and big toenails, poorly developed lunulae, longitudinal angular ridges of individual nail plates occasionally starting proximally from a reddish prominence, platonychia and koilonychia of individual nails often overgrowing the lateral folds, and notches and fissures of the free margins. Histological abnormalities included a prominent granular layer of the nail matrix and epithelial strands and buds extending from the nail bed. There were no associated anomalies. Other nail dystrophies were excluded by differences in clinical and histological features. CONCLUSION: The nail abnormality observed in our family represents a new autosomal dominant disorder for which we propose the term isolated congenital nail dysplasia. Arch Dermatol. 2000;136:1239-1243

Adolescent↗

Intramedullary nails for extracapsular hip fractures in adults.

BACKGROUND: Intramedullary nails may be used for the surgical fixation of extracapsular hip fractures in adults. They may be inserted from the top (cephalocondylic) or from the bottom (condylocephalic) end of the femur. OBJECTIVES: To compare different types or design modifications of intramedullary nails used in the fixation of extracapsular hip fractures. SEARCH STRATEGY: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (March 2006), the Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 1, 2006), MEDLINE, EMBASE, the UK National Research Register, several orthopaedic journals, conference proceedings and reference lists of articles. SELECTION CRITERIA: All randomised or quasi-randomised trials comparing different types of intramedullary nails or modifications to the design of intramedullary nails in the treatment of extracapsular hip fractures in adults. DATA COLLECTION AND ANALYSIS: Both authors independently assessed trial quality and extracted data. Additional information was sought from all trialists. MAIN RESULTS: Six studies, involving a total of 1071 predominantly female and older people with mainly unstable trochanteric fractures, were included. Allocation concealment was likely in one trial, not described in three and not done in the other two trials. Four studies, with 910 participants, compared the proximal femoral nail with the Gamma nail. Though there was increased risk of comminution (fragmentation) at the fracture site when inserting a Gamma nail, there was no statistically significant difference in operative fracture of the femur (1/455 versus 5/455; relative risk 0.33, 95% confidence interval 0.07 to 1.63). No notable differences were seen between implants for fracture healing complications, reoperations and other post-operative complications. Pooled data showed no significant difference between implants for mortality (relative risk 1.08, 95% confidence interval 0.82 to 1.41) or function assessment outcomes. One study, with 80 participants, found no differences between a gliding nail versus a standard Gamma nail. Another study, with 81 participants, found no difference between a dynamically versus a statically locked intramedullary hip screw. AUTHORS' CONCLUSIONS: The limited evidence from the randomised trials undertaken to date is insufficient to determine whether there are important differences in outcome between different designs of intramedullary nails used in the internal fixation of extracapsular hip fractures. Given the evidence of superiority of the sliding hip screw compared with intramedullary nails for extracapsular hip fractures, further studies comparing different designs of intramedullary nails are not a priority. Any new design should be evaluated in a randomised comparison with the sliding hip screw.

Aged↗

Enhanced econazole penetration into human nail by 2-n-nonyl-1,3-dioxolane.

This study determines the enhancing effects of 2-n-nonyl-1,3-dioxolane on the penetration of econazole, an antifungal drug, into the deeper layers of the human nail where fungal infection resides. Aliquots (10 microL) of Econail lacquer formulation containing 0.45 mg of [(14)C]-econazole with 18% 2-n-nonyl-1,3-dioxolane (test group) or without 2-n-nonyl-1,3-dioxolane (control group) were applied twice daily for 14 days to human nails that had been washed with ethanol before each morning's application. The hydration of the nail sample was well controlled to simulate normal physiological conditions. After 14 days of dosing, the inner ventral section of the nail plate was assayed for absorbed drug content, using a micrometer-controlled drilling and nail powder removal system. The mass balance values of [(14)C]-econazole in this study were 90.8 and 96.4% for the test and control groups, respectively. The weight-normalized econazole content in the ventral/intermediate nail plate center in the test group was 6-fold greater than that in the control (p = 0.008). The total econazole absorbed into the supporting bed cotton ball in the test group was nearly 200-fold greater than that in the control group (p = 0.008) over the 14-day period. The amount of econazole after dosing in the inner part of the human nail (potential diseased area) was 11.1 +/- 2.6 (SD) microg/mg of nail powder with 2-n-nonyl-1,3-dioxolane in the lacquer and 1.78 +/- 0.32 microg/mg without 2-n-nonyl-1,3-dioxolane (p = 0.008). The surface nail contained more econazole (p = 0.004), that is, nonabsorbed drug, where 2-n-nonyl-1,3-dioxolane was not part of the dosing solution. Econazole in the support bed under the nail (the total absorbed dose) was 47.5 +/- 22.0 mg in the lacquer with 2-n-nonyl-1,3-dioxolane and 0.2 +/- 0.1 mg in the lacquer without 2-n-nonyl-1,3-dioxolane (p = 0.008). Moreover the concentration in the deep nail layer in the test group is 14,000 times higher than minimum inhibitory concentration (MIC) believed necessary to inhibit the growth of infecting fungi (Dermatophytes species). In a subsequent study, [(14)C]-dioxolane did not penetrate the nail well. Therefore, the mechanism of enhancement of econazole penetration is at the formulation/nail interface.

Administration, Topical↗

[The prosthesis nail -- a new stable fixation device for periprosthetic fractures and critical fractures of the proximal femur].

Increasing numbers of total hip arthroplasties in combination with increasing age and growing daily activities of the elderly lead to increasing numbers of periprosthetic fractures and revision arthroplasties in osteoporotic bone. The prosthesis nail is a hybrid of a hip prosthesis and an intramedullary nail allowing immediate full weight bearing and early rehabilitation. The prosthesis nail consists of three self-locking components: a distally locked intramedullary nail, different lengthening modules, and a hip prosthesis module. From 1992 to 1999, 28 prosthesis nails were implanted in 26 patients (40-88 years, mean age: 71 years). The indications were 21 peri- and subprosthetic fractures caused by trauma, 2 fractures of the proximal femur in combination with a fracture of the femoral head or severe degenerative arthritis, and 4 revision arthroplasties associated with poor bone quality. A combination of the prosthesis nail and bone cement was used in one patient suffering from a pathological fracture of the distal femur. Patients were additionally treated with wire cerclage (six patients) and autogenous bone grafting (ten patients). All patients-except those who received a reconstruction of the acetabulum in the same session (four patients)-were mobilized with full weight bearing on the operated side as soon as wound pain diminished. Bone healing was observed in all periprosthetic fractures. In three patients the prosthesis nail had to be revised: one patient suffered from recurrent dislocations and in one patient weighing 350 pounds limb shortening occurred after the distal locking screw broke. Intramedullary infection was observed once after treatment of a periprosthetic fracture. When bone union was achieved the prosthesis nail was removed and the patient was mobilized with a girdlestone situation. The idea of the prosthesis nail is based on the logical consequence of treating femur fractures with the most efficient procedure, which is intramedullary nailing. The prosthesis nail can be applied according to the requirements of the fracture as a reamed or unreamed nail and immediate full weight bearing is possible. Considering the high average age of the patients, low morbidity, short rehabilitation time, and low costs are the major advantages of this new device. Taking into account the unfavorable preoperative conditions associated with elderly and multimorbid patients, the rate of complications is relatively low.

Acetabulum↗

[Tibia nonunion after intramedullar nailing for fracture: decortication and osteosynthesis by medial plating].

PURPOSE OF THE STUDY: Intramedullar nailing is now widely used for fractures of the tibia. Extension of nailing indications to proximal, distal, and comminuted fractures has led to a significant rate of complications. The purpose of this study was to analyze decortication and medial plating for the treatment of tibial nonunion after intramedullary nailing. MATERIAL AND METHODS: Eighteen cases of aseptic tibial nonunion after nailing for fracture were treated in three women and fifteen men, mean age 39 years (19-57). The initial classification was open (n = 8), segmental (n = 3), single-focus (n = 15). The fracture site was inferior (n = 6), middle (n = 7), and superior (n = 2). Primary nailing used reaming in 15 cases (83%), unreamed in 3 (17%) static in 13 and dynamic in 5. Four plaster cabts were also applied. Complications were: infection (n = 1), compartmental syndrome (n = 2), tibial nerve palsy (n = 1), dysesthesia (n = 2), and protrusion of the nail into the knee (n = 1). Dynamization was performed in 11 patients, one with additional bone graft and fibulectomy. Repeated reamed nailing was performed in one patient. Seven nonunions were atrophic and 11 were hypertrophic. There were 13 malpositionings associated with the nonunion. Treatment of the nonunion was performed 300 days on average (90-900) after nailing: cancellous bone graft was associated with decortication in four cases because of bone loss (n = 3) or atrophic nonunion (n = 1). RESULTS: Union rate was 94%. Mean time for union was 108 days (80-180) with no significant difference (Student t-test) between atrophic (119 days) and hypertrophic (103 days) nonunion. Correction of the malposition was incomplete in seven patients, with angular malunion of less than 6 degrees in five patients and greater than 10 degrees in two. One late infection occurred and finally healed after external fixation and antibiotic therapy. No skin necrosis occurred. Five patients had pain on the hardware. Removal was performed in one time and pain resolved. Improvement of knee and ankle stiffness was achieved in all patients. DISCUSSION: This technique has been used in our department since 1967. Different studies have found a union rate ranging from 94% to 100% with this procedure. Intramedullary nailing, sometimes associated with bone graft or decortication, is also used for tibial nonunion with a good rate of union. The main problem of intramedulary nailing for nonunion, as for fracture, is the difficulty in avoiding malunion. Plating a nonunion, as a fracture, enables better reduction. Skin problems can occur with the medial plate if the soft tissues are damaged. This situation is very uncommon in secondary surgery. CONCLUSION: Decortication and medial plating was a safe and efficient treatment for tibia nonunion after failure of intramedullary nailing and allows better reduction and repeated nailing.

Adult↗

A biomechanical comparison of intramedullary nailing systems for the humerus.

This study evaluated the rotational and bending stability of three interlocking nail systems in paired cadaveric humeri. The Russell-Taylor Humeral Interlocking Nail, the Seidel Humeral Locking Nail, and the True-Flex Humeral Nail were mechanically tested in torsion and four-point bending. The Russell-Taylor and the Seidel interlocking nails are reamed systems that rely on proximal interlocking screws and distal screws or phalanges respectively for rotational stability. However, axillary nerve damage may result during proximal screw placement, and these systems exhibit low resistance to rotation. The True-Flex intramedullary nail is an unreamed system that relies on cross-sectional geometry to achieve rotational stability. By not relying on interlocking screws for stability, nerve damage associated with the screw placement may be eliminated. However, the results indicate the cross-sectional geometry of the True-Flex nail is not able to provide the same degree of static locking as the Russell-Taylor or Seidel interlocking nails. Humeri implanted with the Russell-Taylor and Seidel nails also had a significantly greater torsional stiffness than the True-Flex nail. As expected, humeri implanted with the Russell-Taylor and Seidel nails also had a significantly greater bending stiffness than the True-Flex nail in both anterior-posterior and medial-lateral bending.

Absorptiometry, Photon↗

Internal fixation of supracondylar femoral fractures: comparative biomechanical performance of the 95-degree blade plate and two retrograde nails.

OBJECTIVE: The biomechanical stability of supracondylar femoral fractures fixed with a condylar blade plate (plate), a Green Seligson Henry nail (GSHN), or a new retrograde unreamed supracondylar femoral nail (new nail) based on the AO unreamed femoral nail were compared. DESIGN: A standardized simulated comminuted supracondylar femoral fracture (segmental defect) in fresh frozen paired cadaveric femora was stabilized with one of the implants. The interfragmentary fracture site stiffness in three directions and axial strength of the fixator-bone construct were compared (pairwise). RESULTS: The plate versus the new nail was (a) axially 10 percent as stiff and 50 percent as strong (ultimate strength), (b) as stiff in A/P bending, and (c) five times more stiff in torsion. Varus angle at failure under axial load was significantly greater for the plate than for the new nail. There were no statistical differences in axial stiffness and ultimate strength between the new nail and the GSHN, but the new nail was 50 percent and 30 percent as stiff in A/P bending and torsion, respectively. The magnitude of deformation at failure under axial loading was similar. CONCLUSIONS: In fixation of extraarticular comminuted supracondylar distal femur fractures, results indicate that (a) the new nail provides equal or greater stability than does the plate, except when large torsional loads are anticipated, and (b) the new nail provides stability equal to the GSHN for axial loading and lesser stability against off-axis loads. As is evident in this and other studies, intramedullary implants are less torsionally stiff than are plates. The torsional stiffness of the new nail is expected to be sufficient because it is comparable to many available nails, and low torsional moments are expected for healing femoral supracondylar fractures.

Biomechanical Phenomena↗

Modified tibial nails for treating distal tibia fractures.

OBJECTIVE: To determine the biomechanical consequences of cutting one centimeter off the tip of a tibial nail when treating distal tibia fractures with intramedullary nails. DESIGN: Randomized laboratory investigation using matched pairs of cadaveric tibias with osteotomies made to resemble distal tibia fractures extending to four and five centimeters from the tibiotalar joints. INTERVENTION: The smaller (four-centimeter) distal tibias were stabilized using ten-millimeter diameter tibial nails that had been modified by removing the distal one centimeter of the nail. The five-centimeter distal tibias were stabilized with standard ten-millimeter diameter tibial nails. Each tibia was tested in elastic compression, rotation, and compression-bending on a servohydraulic materials testing machine. MAIN OUTCOME MEASUREMENTS: Stiffness was calculated for each type of loading to compare stability of the modified nail construct to that of the standard nail construct. RESULTS: Four-centimeter distal tibia fragments stabilized with modified nails have comparable stiffness in compression and in torsion to five-centimeter distal tibia fragments stabilized with standard tibial nails. The stiffness in compression-bending was surprisingly low in both groups and differed by only 3.7 percent. CONCLUSIONS: Removal of one centimeter from the tip of a tibial nail allows placement of two distal interlocking screws in tibial fractures located four centimeters from the tibiotalar joint. The fixation strength achieved is comparable to that of standard intramedullary nailing of tibial fractures located five centimeters from the tibiotalar joint using two distal interlocking screws. Fixation strength with these distal fractures, however, is not strong enough to resist moderate compression-bending loads. Thus, patients with distal tibia fractures treated with intramedullary nailing must follow weight-bearing restrictions until significant fracture healing occurs to prevent coronal plane malalignment of the fracture.

Biomechanical Phenomena↗

Does the nail bed really regenerate?

From observations of nail bed injuries, the regeneration of the nail bed seemed evident. The nail bed regenerated well in the presence of the nail matrix and poorly in its absence, suggesting that the nail bed regenerated from the nail matrix. Full-thickness skin graft or flap coverage of nail bed defects resulted in the good nail bed regeneration. The nail bed grew back, pushing the graft or the flap distally. The regenerated nail beds were about 70 percent of normal size in guillotine-type amputations and about 90 percent in the presence of an intact distal phalanx. The difference between full- and split-thickness skin grafts seemed to be adherence to the phalangeal bone, the former giving way to the advancing nail bed and the latter staying in the way. In addition, the destination of the moving nail bed cells was discussed.

Adult↗

Free nonvascularized composite nail grafts: an institutional experience.

Free, nonvascularized composite nail grafts have been reported as a successful method to reconstruct nail deformities due to congenital anomalies or traumatic defects. The authors performed a decade review of their experience with nine patients who had had 10 free, nonvascularized composite nail grafts. Patient demographics, mechanism of injury, timing, site of reconstruction, and amount of nail to be replaced were all recorded. Results of nail growth in reconstructed nails were judged as excellent, good, fair, or poor on the basis of the appearance of the nail. The majority of reconstructed nails had half or more of the nail bed replaced. The 10 cases (mean follow-up of 1.8 years) that were reported had two excellent, three good, two fair, and three poor outcomes. There was no apparent relation between the successful outcome of the procedure and patient age, timing of reconstruction, or amount of nail bed replaced. Although the authors' experience suggests the unpredictable nature of this type of graft, it should be considered for patients who desire nail reconstruction and are not candidates for ablative or vascularized nail complex transfer procedures.

Adolescent↗

A morphological study of ectopic plantar nail.

Ectopic nails are rare. Four adult patients presented to us, affected by true ectopic nails of the foot, sole, and toes, occurring bilaterally in one case. Full documentation of these anomalies was collected. The aim of this study was to better describe the morphologic features of ectopic plantar nails by using, besides histologic evaluation, transmission and scanning electron microscopy. New morphologic criteria were identified to determine if ectopic plantar nail differed from normal and ectopic hand nails. Morphologically, ectopic plantar nails are smaller than normal ones, but still form cuticles, nail grooves and nail folds, and periungual wrinkles. Furthermore, they form with a flat angle between the nail matrix and proximal nail fold, and have a nail plate interrupted by several transverse nails grooves.

Adult↗

Therapeutic effects of a 12-week course of alefacept on nail psoriasis.

BACKGROUND AND OBJECTIVES: Nail psoriasis is a common finding in psoriatic patients and it affects the quality of life in a great proportion of patients. Topical or systemic treatments have limited effectiveness or have a serious toxicity potential. Biologicals such as alefacept are the most recent treatment modalities for psoriasis. In the present study we evaluated changes in nail pathology in patients with plaque psoriasis and nail involvement during treatment with alefacept. PATIENTS AND METHODS: Digital photographs from eight patients were produced, which were analysed using the nail psoriasis severity index (NAPSI). A minimal NAPSI of 15 was chosen to divide patients into a moderate to very severe nail psoriasis group and a group with no or mild nail psoriasis. A decrease in NAPSI of at least 25% was considered a significant response to therapy. RESULTS: In the group with at least moderate nail psoriasis, two patients improved, in two patients the nail changes remained unchanged and in one patient the nail pathology was aggravated. The group with no or mild nail psoriasis showed variable results. CONCLUSIONS: Although alefacept showed some results in treating nail pathology in psoriasis, a more extensive study is required, covering both more patients and a more extensive time period. Furthermore, it would also be clinically relevant to compare the effects of alefacept on nail psoriasis with other biologicals.

Adult↗

[Evaluation of impaction on bone nail and bone plate of the pertrochanteric fracture].

PURPOSE OF THE STUDY: Impaction in pertrochanteric fracture sites is a well known phenomenon; the screw-plate system is designed to stabilise the fracture. Although easier to use, the risk with the nail-plate system is postoperative penetration of the nail into the joint. The present study was conducted to determine the exact conditions of the impaction, and to identify possible ways to improve the nail-plate system. MATERIAL-METHOD: The study included 129 cases of pertrochanteric fracture, excluding sub-trochanteric fractures. All fractures were fixed with a 130 degrees angulated nail-plate. In all cases, consolidation was uneventful after 8 to a 12 weeks. The anatomical type of fracture, i.e. stable or unstable, was determined according to the size of the intermediary fragment, including the trochanter minor. The displacement was measured as the difference between the length of the nail and the length of the femoral head and neck measured along the axis of the femoral neck. The parameters examined were: fracture stability degree, bony mineralisation (Singh Index), nail length, femoral neck, length nail position in the femoral head, and above all, fracture reduction. All these parameters were computerised and compared using Stat View statistics software. RESULTS: Impaction was observed in 43 per cent of cases. Among these, 25 per cent were rated as slight (1 to 5 mm), 18 per cent as moderate (over 5 mm) and 9 per cent as marked (10 to 25 mm). Impaction was associated with demineralisation of the bone tissue (p = 0.001). The anatomical classification of the fracture was not a determining factor (p = 0.19), as marked displacements were also recorded in stable fractures. A posterior and inferior position of the intramedullary nail in the femoral head is one of displacement determining factors (p = 0.004, two-sided 1 test). Valgus over-correction is the most important factor, especially when it is associated with bony demineralisation (p = 0.02) and an inadequately centred intramedullary pin (p = 0.02). Shorter the femoral neck, and shorter the nail, greater was the frequency of nail articular penetration. DISCUSSION: The risk of articular penetration therefore reaches 15 per cent in petrochanteric fractures repaired with a nail plate, set at an angle of 130 degrees. A short neck, a cervicodiaphyseal angle superior to 140 degrees, and demineralisation are the three determining parameters. Stable or unstable fracture has in fact little effect on displacement incidence, and therefore does not, on its own, warrant the use of a prosthesis in comminuted fractures. The authors compared their results to literature on progressive sliding system: the incidence of complications associated with this type of fracture treatment is identical, but the determining parameters are different. CONCLUSION: The study shows that the nail-plate is efficient and provides simple and solid fracture fixation. However, this osteosynthesis material needs to be modified in order to improve its fixation in the femoral head.

Adult↗

[Biomechanics of femoral interlocking nails at the bone-implant transition].

Today there is a variety of different interlocking intramedullary nail designs available for the femur-each designed with a different approach to achieve stability for fracture fixation. We compared different nail types in the bone-implant complex (BIC) of four unreamed solid nails and a slotted, reamed nail to see if there are major differences in stiffness for axial load, bending and torsion. We simulated comminuted mid-shaft fractures by a 2 cm defect osteotomy in paired human cadaver femora. Each bone was tested intact in a Universal testing machine. The results were recorded, osteotomy and osteosynthesis were performed, and the BIC was tested. Relative stiffness was calculated for each individual bone. For P-values less than 0.01 ('least significance difference test') the difference between groups was considered to be significant. In torque testing the unslotted solid nails showed significantly more stiffness (0.6-1.8 Nm/degree) compared to the slotted nail (0.2 Nm/degree). Compared to intact bone (6.9 Nm/degree), both groups of nails were significantly less stiff (relative stiffness 2-20%). In axial load and bending testing, the large-diameter unreamed nail showed greater higher stiffness (32-68%). This study shows that stiffness of the BIC in interlocking femoral nails is more dependent on nail profile than on the press-fit of nails in the medullary canal. For torque stiffness the absence of a slot is of special importance. According to our study, all of the unslotted nails tested give adequate stability for fracture fixation.

Adult↗