Evaluating the effectiveness of evidence-based guidelines for the use of spacer devices in children with acute asthma.

OBJECTIVE: To change standard practice from using nebulisers to metered dose inhalers and holding chambers (spacers) in children presenting with mild to moderate acute asthma. DESIGN: A before-after comparison of children with acute asthma presenting to the emergency department (ED) between August and October 1999 with those presenting between June and August 1997. SETTING: A tertiary care metropolitan children's hospital. INTERVENTIONS: Evidence-based clinical practice guidelines for using spacers were developed by a local multidisciplinary consensus process. A multifaceted guideline implementation program was used in 1999. MAIN OUTCOME MEASURES: Physician prescribing practices (spacer use); clinical outcomes (need for hospitalisation, admission to intensive care unit, and length of stay [LOS]). RESULTS: 75 of 247 children (30%; 95% CI, 25%-36%) required hospital admission in 1999. This was similar to the 1997 study period, when 95 of 326 (29%; 95% CI, 24%-34%) children were admitted. Of those with mild to moderate asthma, 160 (68%) received bronchodilators in the ED; 151 (94%) were initially treated with a spacer device in 1999. In 1997, no children were initially treated with spacers in the ED. The median (range) LOS in hospital for children with asthma of all severities was 1.7 (0.5-19.8) days in 1999 and 1.7 (0.2-7.6) days in 1997 (P=0.85). CONCLUSIONS: We successfully changed standard practice from using nebulisers to spacers for bronchodilator delivery in children with mild to moderate acute asthma, with no difference in the need for or duration of hospitalisation.

Acute Disease↗

Is high-dose fluticasone propionate via a metered-dose inhaler and Volumatic as efficacious as nebulized budesonide in adult asthmatics?

The efficacy and tolerability of fluticasone propionate (FP) 2 mg daily via a metered-dose inhaler and Volumatic (Glaxo Wellcome) spacer device was compared with nebulized budesonide (nBUD), 2 and 4 mg daily, in a multi-centre, open-label, cross-over study of adult asthmatics. Patients received, in random order, either 4 weeks of treatment with FP followed by 4 weeks of treatment with nBUD, or vice versa, with an intervening 4 week 'wash-out' period between treatments. Thirty patients completed the study, of whom 24 were evaluable. In terms of the primary efficacy parameter, change in mean morning peak expiratory flow (PEF) (l min-1) from baseline to the fourth week of each treatment period, FP was more effective than nBUD [mean difference (FP-nBUD) 21.1 l min-1, P = 0.007, 95% CI (6.5, 35.7)]. Sub-group analysis demonstrated FP to be superior to the 4 mg nBUD [mean treatment difference (FP-nBUD) 42.9 l min-1, P = 0.026, 95% CI (7.1, 78.8)] and at least as efficacious as the 2 mg nBUD sub-group [mean treatment difference (FP-nBUD) 10.2 l min-1, P = 0.211, 95% CI (-6.5, 26.9)]. Furthermore, larger reductions in diurnal variation were observed during FP treatment [mean treatment difference (FP-nBUD) -4.4 percentage points, P = 0.028, 95% CI (-8.4, -0.5)]. There was no significant difference between the treatments for the proportion of symptom-free 24 h periods. Of those expressing a preference, significantly more patients found FP via a metered-dose inhaler and spacer device both easier to administer (78%, P = 0.007) and more convenient to take (76%, P = 0.008) than nebulized budesonide. In addition, cost per patient analysis showed that nebulized budesonide was from 1.7 to 3.5 times more expensive than FP.

Adolescent↗

Aerosol profile extracted from spacers as a determinant of actual dose.

PURPOSE: We propose a novel method to evaluate the efficacy of a pressurized metered dose inhaler (pMDI) in combination with a spacer, by not only considering the total dose extractable from the spacer but also the dependence of dose on the volume available for aerosol inhalation. METHODS: We studied volume-dependence of aerosol concentration during extraction from two commonly used plastic spacers (150 ml AerochamberPlus; 750 ml Volumatic) after a single puff of a 100 microg salbutamol pMDI (HFA-Ventolin), using laser photometric measurements. RESULTS: After a delay of is in each spacer, the aerosol peak dose for AerochamberPlus was 2-fold that for Volumatic (p < 0.001), with the peak appearing well within the first 0.5 L even for the largest spacer. The opposite dose relationship is reached when considering total cumulative dose, which was 2-fold higher for Volumatic than for AerochamberPlus (p < 0.001); >95% of total cumulative dose was extracted well within 3 L for the largest spacer. The 2-fold cumulative dose relationship was confirmed by chemical assay on an absolute filter [AerochamberPlus: 21.4+/-3.2 (SD) microg; Volumatic: 43.8+/-9.1 (SD) microg]. CONCLUSIONS: Actual aerosol dose available to patients during inhalation via spacers can only be done on the basis of a quantification of aerosol peak dose and cumulative dose as a function of extracted volume.

Administration, Inhalation↗

Salbutamol and/or beclomethasone diproprionate in asthma.

OBJECTIVE: Acute severe exacerbation of asthma is potentially life threatening and requires critical assessment and appropriate therapy. Now a days, steroids are often combined with bronchodilators for the treatment of bronchial asthma. Therefore, the present study was undertaken to compare effectiveness of beclomethasone diproprionate-salbutamol combination versus salbutamol alone by MDI (with or without spacer) in acute asthma. METHODS: A total of 57 paediatric patients (5-12 years) with acute attack of bronchial asthma attending emergency department of Indira Gandhi Medical College and Hospital was randomised to receive salbutamol (100 microg/puff) alone or with BDP (50 microg/puff) by metered dose inhaler with or without spacer. All baseline investigations were repeated one hour after the therapy. RESULTS: Clinical parameters indicative of severity of asthma improved statistically in all treatment groups. The increase in PEFR was better with MDI-S+B with spacer as compared to other groups, though it failed to reach statistical significance. The fall in serum potassium level is significantly more with MDI-S+B group when spacer was not used. No serious adverse effects were observed in any of the treatment groups. CONCLUSIONS: Metered dose inhalation of BDP-salbutamol combination with spacer provides better recovery whereas fall in serum potassium with MDI-S+B suggests use of spacer and monitoring of serum potassium during treatment.

Administration, Inhalation↗

Clinical comparison of inhaled budesonide delivered either via pressurized metered dose inhaler or Turbuhaler.

The aim of this open, randomized cross-over study was to compare the efficacy and safety of inhaled budesonide administered either via a pressurized metered dose inhaler with a 750 ml spacer attached, or via a new dry powder inhaler, Turbuhaler, in 28 patients with stable bronchial asthma. During the 2-week run-in period, the patients received their ordinary inhaled steroid treatment. This was followed by two 4-week periods of active treatment with inhaled budesonide given via Turbuhaler or pressurized MDI. The patients were divided into two groups according to their previous, inhaled steroid doses. Group A received 400 micrograms of budesonide b.i.d, and Group B 800 micrograms of budesonide b.i.d. Diary cards were used by the patients at home to report asthma symptoms, beta 2-agonist consumption, and PEF twice daily, as well as the number of coughs experienced in a 5-min period after steroid inhalation. Budesonide Turbuhaler produced a significantly better effect on morning peak flow than budesonide MDI. The number of coughs in the 5 min after steroid inhalation was significantly lower with the Turbuhaler than with the MDI. In all other parameters recorded (e.g. FEV1, evening PEF, histamine PC20 and other diary measurements) there were no statistically significant differences between the two devices. Turbuhaler was significantly more appreciated than MDI in all questions of preference. The study showed that budesonide via Turbuhaler was at least as effective and safe as budesonide via a pressurized MDI at daily doses of 800 and 1,600 micrograms.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Inhalation↗

Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers.

Many different metered-dose inhalation devices are becoming available for the treatment of airway diseases. Each of these inhalers differs in its delivery characteristics. An assessment of the efficacy of drug delivery by these inhalers is essential, in view of their therapeutic use. A review of the literature on the relationship between airway deposition and airway effects of drugs delivered from metered-dose inhalers is presented. Nebulizers or spacers are not discussed. The effect of an inhaler depends on the characteristics of the inhaler and the inhalation manoeuvre performed by the patient. This review focuses on the influence of inhaler characteristics on the airway deposition and airway effects. Data from several studies show that there is a significant relationship between the amount of drug deposited in the airways and the airway effects of the drug. Studies on the relationship between airway deposition and airway effect have been troubled by methodological problems, such as the absence of multiple dose comparisons and the difficulty in obtaining steep dose-response curves. The techniques for measuring airway deposition of inhaled drugs, namely the scintigraphic and the pharmacokinetic method, are discussed and compared. The appropriate use of these techniques can help to define and compare the drug delivery characteristics of different devices, thus enabling inhaled therapy to be optimized.

Administration, Inhalation↗

Quality and access to care among a cohort of inner-city adults with asthma: who gets guideline concordant care?

STUDY OBJECTIVES: Asthma morbidity is highest among inner-city populations. This study measured whether quality and access to care over time was concordant with National Asthma Education and Prevention Program (NAEPP) guidelines. It also identified factors associated with NAEPP guideline-concordant care. DESIGN: A prospective, observational cohort study. SETTING: An urban academic medical center. PATIENTS: A consecutive cohort of 198 inner-city adults hospitalized for asthma. MEASUREMENTS: Detailed information about sociodemographics, asthma history, access to care, history of the current exacerbation, prescription and use of inhaled corticosteroids (ICS) and beta-agonists, and other elements of NAEPP-concordant care (spacers, metered-dose inhaler [MDI] technique, peak flow meters, and action plans) was collected during the index admission and 1 month and 6 months after discharge. RESULTS: In this predominantly low-income, nonwhite cohort, while 92% of patients had insurance and 80% had a usual source of care, 73% reported delays in seeking care. ICS were prescribed for 77% of patients prior to hospital admission, 83% at 1 month, and 67% at 6 months. Adherence with other NAEPP recommendations were 89% for receipt of MDI instruction, 68% for spacers, 80% for peak flow meters, 31% for written action plans for worsening, and 22% for written plans for attacks. In multivariate analysis, greater asthma severity and having a usual source of care increased the odds of receiving ICS, spacers, and peak flow meters. Care by a specialist increased the odds of receiving action plans. Patients who spoke mostly Spanish were less likely to be given spacers or action plans. CONCLUSION: Baseline problems with quality and access to care persisted over time. Better systems of care are needed to ensure that high-risk patients receive an appropriate step-up in the quality of ongoing asthma care.

Adult↗

Beclomethasone dipropionate given to adult asthmatics through a new spacer device: effects of high-dose administration.

The usefulness of a metered-dose inhaler equipped with a new spacer device (Jet spacer) was evaluated and compared with that of a standard actuator in the administration of high-dose inhaled beclomethasone dipropionate (0.5 mg four times daily) to adults with moderate asthma. After a 2-week run-in period, 36 patients were enrolled in a 4-week study according to a randomized, parallel-group design. Efficacy was assessed by measurements of pulmonary function and daily beta 2-agonist consumption. Morning serum and 24-hour urinary cortisol levels were measured at baseline and after treatment; adrenocorticotropic hormone (ACTH) stress testing was also done. Spirometric parameters significantly improved in both groups; peak expiratory flow rate measured at the final visit was significantly higher (P < .01) in the group using the Jet spacer than in patients using the standard actuator. Beta 2-agonist consumption decreased in both groups. The number of patients with a normal response to ACTH was significantly higher (P < .01) in the Jet group than in the standard actuator group; concomitant urinary cortisol excretion decreased significantly (P < .05) in the standard actuator group. Local irritation was reported by 1 patient in the Jet group and by 2 patients in the standard actuator group. Use of the new Jet spacer was found to reduce the potential for adrenal suppression and increase the efficacy of high-dose inhaled beclomethasone dipropionate given to adults with asthma.

Adolescent↗

The efficacy of alternative spacer devices for delivery of aerosol therapy to children with asthma.

Spacer devices are important aids for use with metered dose inhalers in children with asthma. However, expense and unavailability of commercially produced spacers in developing countries have limited their use. Home-made spacers in the form of cups or bottles are widely used despite a lack of data confirming their efficacy. We investigated the relative efficacy of three spacers (a commercially available spacer, a modified 500-ml cold drink bottle and a polystyrene cup) for delivery of aerosolized drugs to asthmatic children older than 5 years. We also investigated the effect of leaks in the delivery system by comparing delivery via a sealed and an unsealed cold drink bottle. Lung deposition of aerosolized Tc-99m DTPA inhaled via spacer was measured in 30 patients. The median aerosol deposition in the lungs was significantly greater for the conventional spacer than for the cup (31.5% vs 9.5%; Z = -2.8, p = 0.005). Median aerosol deposition for the conventional spacer and sealed bottle were equivalent (40.5% vs 44%). Aerosol deposition from the sealed and unsealed bottle was significantly different (43.5% vs 24%; Z = -2.54, p = 0.01); however, the unsealed bottle was more efficient than the cup. We conclude that a modified 500-ml cold drink bottle is an efficient spacer. Leaks in this system are a major factor affecting the amount of drug deposited. The modified polystyrene cup is not an efficient spacer, delivering between a third and a fifth of the dose that other spacers were capable of delivering.

Administration, Inhalation↗

Recent advances in aerosol therapy for children with asthma.

Inhalational drug delivery is the primary mode of asthma therapy in children and is the main focus of this article. Pressurized metered dose inhalers (pMDIs) are now the method of choice in infants and children under 5 years old, when used in combination with an appropriate valved holding chamber or spacer. Spacers are particularly important for steroid inhalation to maximize lung deposition and minimize unwanted oropharyngeal deposition. Optimal inhalation technique with a pMDI-spacer in infants is to inhale the drug by breathing tidally through the spacer. Drug delivery to the lungs using pMDIs can vary greatly, depending on the formulation used and the age of the child. Dry powder inhalers (DPIs) are driven by the peak inspiratory flow of the patient and are usually not appropriate for children under 5 or 6 years of age. Nebulizers continue to play a role in the treatment of acute asthma where high doses of bronchodilator are required, though multiple doses via pMDI spacer may suffice. Important drug delivery issues specific to children include compliance, use of mask versus mouthpiece, lower tidal volumes and inspiratory flows, determination of appropriate dosages, and minimization of adverse local and systemic effects.

Administration, Inhalation↗

Nebulizers or pressurized metered-dose inhalers in the treatment of asthma exacerbations.

The use of inhaled beta2-agonists delivered by a metered-dose inhaler (MDI) with a holding chamber (spacer) actually is considered the best treatment for childhood acute asthma. However, its use in daily practice still seems rather limited. The aim of this study was to investigate, using a questionnaire, the use of a nebulizer or MDI as the first-line method for delivering inhaled beta2-agonists in children with acute asthma. A questionnaire was developed and distributed to 22 pediatric departments and to 131 family pediatricians (FPs) in northeast Italy. We showed that in the hospitals the episodes of acute asthma usually were treated with bronchodilators administered by wet nebulization (95.45%). This was the case also for FPs (70.9%). However, 29.1% of FPs usually advised the use of an MDI/holding chamber to children with acute asthma. Despite the established efficacy of inhaled beta2-agonists administrated with an MDI compared with wet nebulization in acute asthma, this practice still is rather limited. The use of wet nebulization was more evident in hospital settings compared with community medicine. Emergency room visits may represent a missed opportunity to promote an effective method of delivering bronchodilators in childhood asthma.

Acute Disease↗

Bronchodilator effect of terbutaline aerosol in asthmatic: comparison of two spacer devices.

The degree of bronchodilation achieved with aerosolised bronchodilators may partly depend on correct usage of a particular inhaler device. The effect of two puffs of 0.25 mg each of terbutaline aerosol using either of two spacer devices--a tube spacer and conical spacer with inhalation valve (Nebuhaler)--in a randomised manner were compared in 20 patients with bronchial asthma. All participants (11 male, 9 female) aged 16 to 50 years had clinically stable baseline airway obstruction responsive to bronchodilators. The maximum per cent increase of PEFR and FEV1 were significantly higher after inhalation via Nebuhaler than tube spacer (44.93 +/- 21.15% vs 26.67 +/- 13.17%; 74.0 +/- 17.87 vs 47.65 +/- 15.74% respectively, p less than 0.01). The increase noted at each time interval was significantly higher and more sustained with Nebuhaler. In terms of bronchodilator effect Nebuhaler had definite advantage over tube spacer in our study. There were no significant changes in pulse rate nor in blood pressure.

Administration, Inhalation↗

Holding chambers versus nebulisers for beta-agonist treatment of acute asthma.

BACKGROUND: In acute asthma inhaled beta-agonists are often administered to relieve bronchospasm by wet nebulisation, but some have argued that metered-dose inhalers with a holding chamber (spacer) can be equally effective. In the community setting nebulisers are more expensive, require a power source and need regular maintenance. OBJECTIVES: There is controversy as to whether wet nebulisers are better than metered dose inhalers with holding chambers to deliver beta2-agonist medications for acute asthma. Comparisons of hospital and home use are also of interest. The objective of this review was to assess the effects of holding chambers compared to nebulisers for the delivery of beta2-agonists for acute asthma. SEARCH STRATEGY: We searched the Cochrane Airways Group trials register and the Cochrane Controlled Trials Register. SELECTION CRITERIA: Randomised trials in adults and children (from two years of age) with asthma, where holding chamber beta2-agonist delivery was compared with wet nebulisation. DATA COLLECTION AND ANALYSIS: One reviewer applied study inclusion criteria and extracted the data. Trial quality was assessed independently by two reviewers. Missing data were obtained from the authors or estimated. MAIN RESULTS: This review analysed 686 children and 375 adults included in 16 trials. Method of delivery of beta2-agonist did not appear to affect hospital admission rates. In adults, the odds ratio of holding chamber versus nebuliser was 1.12, 95% confidence interval 0.45 to 2.76. The odds ratio for children was 0.91, 95% confidence interval 0.4 to 2.1. Children's length of stay in the emergency department was significantly shorter when the holding chamber was used, with a weighted mean difference of -0.62 hours, 95% confidence interval -0.84 to -0.40 hours. Adults' length of stay in the emergency department was similar for the two delivery methods. Peak flow and forced expiratory volume were also similar for the two delivery methods. Pulse rate was lower for holding chamber in children, weighted mean difference -8.3% baseline, 95% confidence interval -11.5 to -5.0,. REVIEWER'S CONCLUSIONS: Metered-dose inhalers with holding chamber produced outcomes that were at least equivalent to nebuliser delivery. Holding chambers may have some advantages compared to nebulisers for children with acute asthma.

Acute Disease↗

Application and efficacy of the multi-dose powder inhaler, Easyhaler, in children with asthma.

With powder inhalers, optimal performance is dependent on the inspiratory flow produced by the patient through the devices. The objective of this open, non-randomized study was to evaluate the suitability of a new, multidose, dry powder inhaler, the Easyhaler, for children with asthma. The peak inspiratory flow (PIF) through the Easyhaler (PIF(EH)) was measured with a pneumotachograph in 120 asthmatic children aged 4-16 yr. The bronchodilatory effect of 0.2 mg salbutamol through the Easyhaler was compared with that of 0.2 mg salbutamol through a metered dose inhaler (MDI) with a spacer, in 15 children with obstruction. The mean PIF(EH) was 56 l/min (range 22-83 l/min). The PIF(EH) correlated significantly with age, height, and absolute peak expiratory flow (PEF), but not with the level of obstruction (PEF percentage of predicted, range 45-146%). Only four children (aged 5, 6, 10, and 16 yr) had PIF(EH) values below 28 l/min, which has been shown in in vitro studies to be the threshold for effective use of the Easyhaler. In 15 children with PEF, < 85% of predicted bronchodilatory effects of 0.2 mg salbutamol through the Easyhaler and from an MDI-cum-spacer were equal. Most children aged 6-16 yr produce PIF values sufficient for the use of the Easyhaler. The gain of 0.2 mg salbutamol from the Easyhaler was equal to that from a new, unprimed, MDI with a spacer in children with asthma.

Administration, Inhalation↗

Salmeterol administration by metered-dose inhaler alone vs metered-dose inhaler plus valved holding chamber.

STUDY OBJECTIVE: To determine whether a spacer device designed as a valved holding chamber with a flow signal increases the efficacy of the long-acting beta(2)-agonist, salmeterol, in patients who use incorrect technique with metered-dose inhaler (MDI) alone. DESIGN: Double-blind, randomized, placebo-controlled study. SETTING: University hospital outpatient rooms. PATIENTS: Twenty adult outpatients with stable persistent asthma, receiving a daily anti-inflammatory drug. INTERVENTIONS: Patients were randomized to either salmeterol MDI (incorrect use: 1 s after actuating MDI, inhale rapidly) and placebo plus spacer (correct use: inhale slowly as MDI is actuated, continue to inhale slowly and deeply) or placebo MDI (incorrect use) and salmeterol plus spacer (correct use). The following week, patients received the opposite treatment. The dose was two puffs from each device on each treatment day; each puff was separated by 1 min. MEASUREMENTS AND RESULTS: After baseline peak expiratory flow (PEF), salmeterol was administered and serial PEF determined (0.5, 1, 2, 3, 4, 6, 8, 10, and 12 h). Administration of salmeterol MDI plus spacer resulted in significantly greater increases in PEF from baseline vs MDI at 4 h (44 L/min vs 10 L/min; p < 0.01) and 6 h (49 L/min vs 24 L/min; p < 0.05). Both methods of administration were equally well tolerated. CONCLUSION: We conclude that patients who have poor timing and rapid inhalation with salmeterol MDI alone will have greater increases in PEF at 4 h and 6 h and no additional side effects if the dose is administered with a valved holding chamber that is used correctly. Further study is needed regarding other errors in MDI technique with salmeterol.

Adult↗

Aerosol therapy for asthma.

Inhaled drugs play an important role in asthma management. The correct use of an appropriate delivery device is necessary to achieve the desired therapeutic effects of the drug. Currently, chlorofluorocarbon-propelled metered-dose inhalers, with or without spacers, are the most popular aerosol delivery devices. With the planned phase out of the chlorofluorocarbon metered-dose inhalers, the use of other delivery devices is being emphasized. To achieve optimal therapeutic effects, the drug and the delivery device should be considered a "couple". Aerosol delivery devices should provide an adequate "drug dose to the lung", be cost effective, simple to operate, minimize oropharyngeal deposition and systemic side effects, and match the patient's requirements. A new generation of aerosol delivery devices, incorporating the latest advances in aerosol technology, is likely to fulfill many of the goals mentioned above.

Administration, Inhalation↗

Evaluation of aerosol drug output from the OptiChamber and AeroChamber spacers in a model system.

Metered-dose inhalers (MDIs) are an effective means of generating drug-containing aerosols targeted for delivery to intrapulmonary airways. Many problems associated with incorrect patient use of MDIs are mitigated by adding a valved spacer device to the inhaler mouthpiece. This in vitro study compared the efficiency of drug output through a new spacer device, OptiChamber (HealthScan Products Inc., Cedar Grove, NJ), to that of a device commercially available since the 1980s, AeroChamber (Monaghan Medical, Plattsburgh, NY). Testing utilized MDI formulations of albuterol, beclomethasone dipropionate, and cromolyn sodium. OptiChamber equaled or, in the majority of cases, exceeded AeroChamber in output of the three drugs at two simulated inspiratory flow rates. Drug output from OptiChamber was found to be less sensitive to changes in flow rate than that from AeroChamber. OptiChamber also showed less decrease in drug output than AeroChamber when time delays were introduced between MDI actuation and the start of a simulated inhalation. Mass median aerodynamic diameters of drugs exiting the two spacers were generally similar to those of drugs exiting the MDI alone. However, spacers were shown to nearly eliminate the output of large-size drug particles (>5.8 microm), which can result in oropharyngeal drug deposition. Emitted fine-particle drug (<5.8 microm) doses from OptiChamber were greater than those from AeroChamber with or without a delay between canister actuation and the start of a simulated inhalation. The results suggest that OptiChamber may provide more efficacious aerosol drug delivery than AeroChamber under both ideal and suboptimal conditions.

Aerosols↗

Terbutaline metered-dose inhalation vs metaproterenol by hand-held nebulization: a comparison in black inner-city COPD patients.

A greater percentage of the inner-city black population suffers from chronic obstructive pulmonary disease (COPD) than does the white population in general. Urban black patients are also more likely than urban white patients to receive primary care for their COPD symptoms in area emergency rooms, which can affect the resources available for medical care in these institutions. The present study compared the standard of therapy at Provident Medical Center, metaproterenol, administered by a hand-held nebulizer (HHN), with therapy using terbutaline, administered by a metered-dose inhaler (MDI) with a spacer, in 60 black patients with mild to moderate respiratory distress.Measurements of peak expiratory flow rates before and after therapy indicated that both methods of treatment provided similar relief. The terbutaline MDI modality, however, required less equipment and therapist time, and patients could continue the same therapy at home. All 60 patients were sent home on terbutaline MDI therapy. Follow-up by questionnaire, two to three weeks later, showed 95 percent of 36 respondents preferred the terbutaline MDI with spacer compared with their previous therapy.

Administration, Inhalation↗