Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “INTERFEROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

[Experimental study of vibration analysis in middle ear models by holographic interferometry. Effects of the cross-sectioned area of aditus on the vibration of tympanic membrane].

To aid in the establishment of optimum conditions for postoperative function of the tympanic membrane, a model of the middle ear was experimentally prepared, the cross-sectioned area of aditus ad antrum was altered and the effects on the tympanic membrane vibrational characteristics were observed using the holographic interference method. The following results were obtained. 1) At the low frequencies below 2 kHz, the vibration mode of tympanic membrane was concentric on the whole, but the vibration pattern became fractionated at 4 kHz and above. The frequency of onset of the fractionated vibration pattern was changed only by the conditions of the membrane itself and was not affected much by the sound pressure, the volume of the middle ear cavity and the cross-sectioned area of aditus ad antrum. 2) There were resonance and anti-resonance points in the tympanic vibration pattern. These resonance and anti-resonance frequencies became higher as the diameter of aditus increased until eventually a constant value was reached. At diameters in excess of this constant value, the resonance frequency tended to fall and the anti-resonance frequency tended to rise. 3) The tympanic vibration in the middle ear cavity was not influenced very much by the diameter of aditus at 250Hz. Vibration decreased when aditus was blocked at 500Hz and the opening diameter had a major influence at 1kHz. Vibration was maximum at a diameter of about 2mm and a minimum when aditus was blocked. At 2 to 3kHz, the effects on vibration increased when aditus was blocked. 4) When aditus ad antrum was blocked, the vibration frequency characteristics of tympanic membrane deteriorated at under 1kHz and improved at 2 to 3kHz. When a comparison was made between the case with opened aditus, (which was considered to be equivalent to the closed method of tympano-plasty), and the case with closed aditus, (considered to be equivalent to the open method), the vibration frequency characteristics of the tympanic membrane improved in the low sound region up to 2kHz when the diameter was 4mm.

Ear, Middle↗

[Evaluation of tear film stability by means of laser interferometry].

PURPOSE: The paper presents a new method for evaluation of the tear film stability on the human eye. METHODS: The tear film distribution on the cornea is measured by the lateral shearing interference technique. The eye is kept open during approximately a two-minute recording, when the blinking has to be prevented. Continuous recording and viewing of interferograms enables registration of the changes in disturbances of interference fringes during elapsed time. The changes in fringes are caused by evaporation of tears from the ocular surface and appearance of the breakups. CONCLUSIONS: The noninvasive tear breakup time (NITBUT) can be evaluated by comparing the recorded consecutive interferograms.

Cornea↗

Determination of excimer laser ablation rates of corneal tissue using wax impressions of ablation craters and white-light interferometry.

BACKGROUND AND OBJECTIVE: Efforts to better understand the processes of corneal ablation are aided by a means to precisely measure corneal tissue ablation rates. MATERIALS AND METHODS: A white-light interferometer was used to measure the depth of argon fluoride laser ablation craters and wax impressions of the ablation craters. The technique was validated using polymethylmethacrylate (PMMA), and was then used to measure the ablation rate of bovine corneal tissue. RESULTS: The ablation rate was measured as 0.47 microm/pulse from direct measurement of the PMMA ablation craters and as 0.48 microm/pulse from measurement of the corresponding wax impressions. The ablation rate of bovine corneal tissue was found to be 0.90 microm/pulse. CONCLUSIONS: Wax impressions provide a valid representation of ablation craters. The ablation depth of corneal tissue and PMMA was found to increase linearly with increasing number of laser pulses, and the slope of the regression lines provided a measure of the laser ablation rate.

Animals↗

[Partial coherent interferometry--an alternative method for intraocular lens power calculation performed by ultrasonography].

PURPOSE: To compare axial length estimated by means of Zeiss IOLMaster and A-scan ultrasonography and anticipate postoperative refraction after IOL implantation with refraction measured after operation. MATERIAL AND METHODS: 26 patients were analyzed. Measurement of axial length was performed by Zeiss IOLMaster and A-scan ultrasonography. Preoperative refraction was determined by both methods based on SRK/T calculation formula and 119.0 and 120.5 A-constant for IOL. Postoperative refraction was expressed as a spherical equivalent and was obtained by autokeratorefraktometry in the first day after cataract surgery. RESULTS: Mean axial length measured by IOLMaster was longer by 0.06 mm in compared to ultrasound estimation (p < 0.001). The correlation between pre-operative refraction values determined by IOLMaster and post-operative measurements was statistically significant (p = 0.03). CONCLUSIONS: Measurement of axial length performed by IOLMaster is longer than by ultrasonography. IOLMaster seems to be more reliable method than ultrasonography in intraocular artificial lens calculation in cataract surgery.

Aged↗

Study of precorneal tear film thickness and structure by interferometry and confocal microscopy.

Past measurements of precorneal tear film thickness in rabbits and humans gave values of 4-7 microns. These have been the accepted values. However, measurements presented in this report are much higher. Earlier techniques may have changed film thickness or not have fully included the layer containing mucus. Little is known about the mucus component. Thickness was measured in freshly killed animals of 10 species using two independent optical techniques. Coherent light was reflected from eyes and thickness was determined from spacing of interference fringes. Clear images of tissue structure were obtained with confocal microscopy, the tear film was visually identified, and thickness measured. Measurements by the two methods were closely correlated in each animal. No film was detected in trout or carp. In other species, thickness ranged from 9 microns in frogs to 15 microns in gerbils. Values are significantly larger than earlier estimates. Film thickness in three living rabbits was not significantly different from that measured shortly after death. There was no variation in thickness at five positions across the cornea in three species. Mucus content of rat tear film was examined by measuring thinning after application of 4, 8, and 20% (weight/volume) acetylcysteine, a mucolytic agent. Thickness was considerably reduced compared to controls, and the film almost completely removed by the highest concentration. The authors propose that the film is largely composed of mucus, not free aqueous solution. Our methods include such layers, and measurements are correspondingly larger than earlier ones.

Animals↗

A study of acrylic resin denture base material distortion using computer-aided holographic interferometry.

A holographic interferometer for investigating deformations of dental prostheses is described. Residual stress relaxation resulting from the polymerization of acrylic resin dentures is qualitatively studied during the first 48 hours following fabrication. The resulting fringe patterns show a symmetry that is correlated to the shape of the denture. A quantitative analysis of the interferograms was performed with the aid of a computer program. The computer-aided holographic interferometer was tested using disk-shaped acrylic resin materials. Dimensional deformations resulting from temperature changes were measured with an accuracy better than 0.2 microns. Because of the aging of the resin material, the reaction to temperature changes may differ as a function of time and may be studied using quantitative comparison of deformation plots. For convenience, the original object shape can be added to or subtracted from the graphical deformation data.

Acrylic Resins↗