Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “High Throughput Screening”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

High throughput screening of methylation status of genes in prostate cancer using an oligonucleotide methylation array.

Recent work using high-throughput microarray technology has discovered altered expression of a large number of genes in prostate cancer. Many of these alterations may be the consequence of changes in methylation status in the CpG islands of promoter or exon 1 regions of these genes. In order to determine the methylation status of a large number of genes and ESTs we combined the principle of match/mismatch hybridization with the technique of whole genome labeling to develop a highly specific oligonucleotide-based methylation microarray. Using this array, we analyzed the methylation status of 105 genes and ESTs in three prostate cancer cell lines. Between 32 and 47% of these genes and ESTs were methylated in these cell lines. By correlating the methylation status of this array with the results of Affymetrix expression arrays of three prostate cancer cell lines, we determined that methylation of genes played a significant role (37%) in down-regulating the expression of certain genes in prostate cancer. We also tested this array on a number of primary prostate tissue samples. Our results indicated that a subset of genes in this microarray (25/105) were methylated in all prostate cancer samples but not in normal prostate, suggesting the potential significance of alterations in the methylation status of certain genes in the development of prostate cancer.

Acetylation↗

High throughput screening of sub-ppb levels of basic drugs in equine plasma by liquid chromatography-tandem mass spectrometry.

This paper describes a high throughput LC-MS-MS method for the screening of 75 basic drugs in equine plasma at sub-ppb levels. The test scope covers diversified classes of drugs including some alpha- and beta-blockers, alpha- and beta-agonists, antihypotensives, antihypertensives, analgesics, antiarrhythmics, antidepressants, antidiabetics, antipsychotics, antiulcers, anxiolytics, bronchodilators, CNS stimulants, decongestants, sedatives, tranquilizers and vasodilators. A plasma sample was first deproteinated by addition of trichloroacetic acid. Basic drugs were then extracted by solid-phase extraction (SPE) using a Bond Elut Certify cartridge, and analysed by LC-MS-MS in positive electrospray ionization (+ESI) and multiple reaction monitoring (MRM) mode. Liquid chromatography was performed using a short C(8) column (3.3 cm L x 2.1mm ID with 3 microm particles) to provide fast analysis time. The overall instrument turnaround time was 8 min, inclusive of post-run and equilibration time. No interference from the matrices at the expected retention times of the targeted masses was observed. Over 60% of the drugs studied gave limits of detection (LoD) at or below 25 pg/mL, with some LoDs reaching down to 0.5 pg/mL. The inter-day precision for the relative retention times ranged from 0.01 to 0.54%, and that for the relative peak area ratios (relative to the internal standard) ranged from 4 to 37%. The results indicated that the method has acceptable precision to be used on a day-to-day basis for qualitative identification.

Animals↗

Biomonitoring human exposure to organohalogenated substances by measuring urinary chlorophenols using a high-throughput screening (HTS) immunochemical method.

The widespread contamination of the environment by persistent organochlorinated substances is well-known. High-throughput immunochemical methods may improve routine assessment of the exposure of the population to these chemicals by analyzing urinary biomarkers. Trichlorophenols (TCP) have often been considered as biomarkers of many organochlorinated compounds. With the aim to assess exposure of the population to these substances a high-throughput immunosorbent solid-phase extraction (HTS-IS-SPE) procedure coupled to ELISA for simultaneous analyses of 2,4,6-TCP immunoreactivity equivalents (2,4,6-TCP-IR equiv) in multiple hydrolyzed urine samples has been developed. Around 100 urine samples can be processed simultaneously with an inter- and intraassay precision lower than 23% CV and a limit of detection of 0.3 microg L(-1). The analyses by HTS-IS-SPE-ELISA and HTS-IS-SPE-GC/MS of urine samples (N = 117) collected from three different population groups point to a broad exposure of the Catalonian population to organohalogenated substances including the recently emerging organobrominated pollutants. Environment and edible products seem to be the most likely sources of exposure, since excretion of 2,4,6-TCP-IR equiv has been found to be independent from the occupational sector. An excellent correlation was observed between the 2,4,6-TCP-IR equiv determined by HTS-IS-SPE-ELISA and the concentrations measured by HTS-IS-SPE-GC/MS (R2 = 0.912). The results show that immunochemical screening methods, based on the quantification of urinary biomarkers, can be excellent tools for exposure assessment. The HTS-IS-SPE-ELISA presented here has proved to be efficient, precise, accurate, rapid, and specific, which opens up the possibility for a broad variety of applications where routine testing of large number of samples is required.

Chlorophenols↗

Combinatorial materials synthesis and high-throughput screening: an integrated materials chip approach to mapping phase diagrams and discovery and optimization of functional materials.

Combinatorial materials synthesis methods and high-throughput evaluation techniques have been developed to accelerate the process of materials discovery and optimization and phase-diagram mapping. Analogous to integrated circuit chips, integrated materials chips containing thousands of discrete different compositions or continuous phase diagrams, often in the form of high-quality epitaxial thin films, can be fabricated and screened for interesting properties. Microspot x-ray method, various optical measurement techniques, and a novel evanescent microwave microscope have been used to characterize the structural, optical, magnetic, and electrical properties of samples on the materials chips. These techniques are routinely used to discover/optimize and map phase diagrams of ferroelectric, dielectric, optical, magnetic, and superconducting materials.

Combinatorial Chemistry Techniques↗

Improvement of H2O2 stability of manganese peroxidase by combinatorial mutagenesis and high-throughput screening using in vitro expression with protein disulfide isomerase.

A functional expression system for a heme protein of Phanerochaete chrysosporium, manganese peroxidase (MnP), was developed using the Escherichia coli in vitro coupled transcription/translation system in the presence of hemin and fungal protein disulfide isomerase. This system has allowed the high-throughput construction and screening of a large diversity of mutant heme enzymes and has made it possible to improve the enzymatic function efficiently. Here we increased the H2O2 stability of MnP using this system; a mutant MnP library containing three randomized amino acid residues located in the H2O2-binding pocket of MnP was designed and constructed on a 384-well plate using SIMPLEX (single-molecule-PCR-linked in vitro expression). The screening of 10(4) samples independently expressed for improved H2O2 stability led to four positive mutants, the H2O2 stability of which was nine times higher than that of the wild-type.

Amino Acids↗

Identification of glycogen synthase kinase 3alpha/beta as a host factor required for HBV transcription using high-throughput screening.

BACKGROUND AND AIMS: HBV leads to severe liver diseases, such as cirrhosis and HCC. Identification of host factors that regulate HBV replication can provide new therapeutic targets. The discovery of sodium taurocholate cotransporting polypeptide (NTCP) as an HBV entry receptor has enabled the establishment of hepatic cell lines for analyzing HBV infection and propagation. Using this new system, studies aimed at identifying host factors that regulate HBV propagation have increased. APPROACH AND RESULTS: We established an HBV-based-reporter gene expression system that mimics HBV replication from transcription to virus egress. Using this approach, we screened 1827 Food and Drug Administration-approved compounds and identified glycogen synthase kinase 3 (GSK3)alpha/beta inhibitors, including AZD1080, CHIR-98014, CHIR-98021, BIO, and AZD2858, as anti-HBV compounds. These compounds suppressed HBeAg and HBsAg production in HBV-infected human primary hepatocytes. Proteome analysis revealed that GSK3alpha/beta phosphorylated forkhead box K1/2 (FOXK1/2)s. A double-knockout of FOXK1/2 in HBV-infected HepG2-NTCP cells reduced HBeAg and HBsAg production. The rescue of FOXK2 expression, but not FOXK1 expression, in FOXK1/2-double-knockout cells restored HBeAg and HBsAg production. Importantly, phosphorylation of FOXK2 at Ser 424 is required for GSK3alpha/beta-mediated HBeAg and HBsAg production. We observed the binding of FOXK2 to HBV DNA in HepG2-NTCP cells. CONCLUSIONS: Our recombinant HBV-based screening system enables the discovery of new targets. Using our approach, we identified GSK3 inhibitors as potential anti-HBV agents.

Humans↗

High throughput screening of human subtelomeric DNA for copy number changes using multiplex amplifiable probe hybridisation (MAPH).

BACKGROUND: Subtelomeric regions of the human genome are gene rich, with a high level of sequence polymorphism. A number of clinical conditions, including learning disability, have been attributed to subtelomeric deletions or duplications, but screening for deletion in these regions using conventional cytogenetic methods and fluorescence in situ hybridisation (FISH) is laborious. Here we report that a new method, multiplex amplifiable probe hybridisation (MAPH), can be used to screen for copy number at subtelomeric regions. METHODS: We have constructed a set of MAPH probes with each subtelomeric region represented at least once, so that one gel lane can assay copy number at all chromosome ends in one person. Each probe has been sequenced and, where possible, its position relative to the telomere determined by comparison with mapped clones. RESULTS: The sensitivity of the probes has been characterised on a series of cytogenetically verified positive controls and 83 normal controls were used to assess the frequency of polymorphic copy number with no apparent phenotypic effect. We have also used MAPH to test a cohort of 37 people selected from males referred for fragile X syndrome testing and found six changes that were confirmed by dosage PCR. CONCLUSIONS: MAPH can be used to screen subtelomeric regions of chromosomes for deletions and duplications before confirmation by FISH or dosage PCR. The high throughput nature of this technique allows it to be used for large scale screening of subtelomeric copy number, before confirmation by FISH. In practice, the availability of a rapid and efficient screen may allow subtelomeric analysis to be applied to a wider selection of patients than is currently possible using FISH alone.

Analysis of Variance↗

A high-throughput screening procedure for identifying mice with aberrant taste and oromotor function.

Little is known about how specific genes influence taste function in mammals. One of the most promising ways to fill this void is to screen the progeny of chemically mutagenized (or genetically altered) mice for aberrant taste phenotypes and then identify the mutated gene(s) that is associated with each taste anomaly. To exploit this approach, a high-throughput and robust screening procedure is needed. We have attempted to meet this demand by developing an automated procedure that assesses taste responsiveness of individual mice to palatable and unpalatable taste stimuli. We focused on three taste stimuli (quinine hydrochloride, QHCl; sodium chloride, NaCl; and sucrose) and one mouse strain (C57BL/6). We used a commercially available gustometer system that both monitors the licking responses of mice and controls the presentation of each taste stimulus during successive 5 s trials. We describe a screening procedure that (after 2 days of simple training) can generate a concentration-response curve for NaCl or sucrose during a single 30 min test session, and for QHCl over three 30 min test sessions. A normative database based on the responses of 98 mice subjected to our screening procedure is also presented. We envision that investigators could use this normative database to assess taste function in the progeny of mutagenized (or genetically altered) mice. Any mouse that deviates significantly-e.g. three standard deviations (SD)-from the mean of the normative database would be flagged as having a potentially interesting mutation. We also developed an additional second screen for identifying mice with oromotor abnormalities. This latter screen is necessary because oromotor problems could lead to false positives or negatives in the screen for taste function, but is also useful for researchers interested in genes influencing oromotor circuitry. Throughout the development of the screening protocol, we sought to balance two conflicting demands: the need to maximize the screen's sensitivity and minimize its duration. This screen represents a significant improvement over the common two-bottle preference test because it assesses taste function more specifically and in a fraction of the time.

Animals↗

Using high-throughput screening data to discriminate compounds with single-target effects from those with side effects.

The most desirable compound leads from high-throughput assays are those with novel biological activities resulting from their action on a single biological target. Valuable resources can be wasted on compound leads with significant 'side effects' on additional biological targets; therefore, technical refinements to identify compounds that primarily have effects resulting from a single target are needed. This study explores the use of multiple assays of a chemical library and a statistic based on entropy to identify lead compound classes that have patterns of assay activity resulting primarily from small molecule action on a single target. This statistic, called the coincidence score, discriminates with 88% accuracy compound classes known to act primarily on a single target from compound classes with significant side effects on nonhomologous targets. Furthermore, a significant number of the compound classes predicted to have primarily single-target effects contain known bioactive compounds. We also show that a compound's known biological target or mechanism of action can often be suggested by its pattern of activities in multiple assays.

Drug-Related Side Effects and Adverse Reactions↗

High throughput screening of library compounds against an oligonucleotide substructure of an RNA target.

Approximately 300,000 compounds from selected libraries were screened against a subdomain of a hepatitis C viral (HCV) RNA using a high throughput flow injection mass spectrometry (FIA-MS) method with automated data storage and analysis. Samples contained 2 microM RNA target and 10 microM of each of up to ten ligands. Preliminary studies to optimize operational parameters used the binding of aminoglycosides to the A44 subdomain of bacterial RNA. Binding (confirmed by titration) and sensitivity were maximized within the constraints of the library and throughput. The mobile phase of 5 mM ammonium acetate in 50% isopropanol maintained the noncovalent complexes and provided good detection by electrospray mass spectrometry. Additionally, this composition maximized general solubility of the various classes of compounds including the oligonucleotide and organic library molecules. Cation adduction was insignificant in this screen although some solute and target dependent acetate adduction was observed. The ion trap mass spectrometer provided sufficient mass resolution to identify complexes of RNA with known components of the library. Converted mass spectral data (netCDF) were subjected to two types of statistical evaluation based on binding. The first algorithm identified noncovalent complexes that correlated with the molecular weights of the injected compounds. The second yielded the largest peak in the noncovalent complex region of the spectrum; this spectrum may or may not correlate with expected well components. Sixty-three compounds were confirmed to bind by more stringent secondary testing. Titrations, which were carried out with selected binding compounds, yielded a range of dissociation constants. Biological activity was observed for eleven confirmed binders.

Ligands↗

Development of a cyanovirin-N-HIV-1 gp120 binding assay for high throughput screening of natural product extracts by time-resolved fluorescence.

The unique, high-affinity binding of cyanovirin-N (CV-N), a potent anti-human immunodeficiency virus (HIV) protein, to the HIV envelope glycoprotein gp120, was exploited to develop an HTS assay in an attempt to discover small-molecule mimetics of CV-N. A competition binding assay was developed using CV-N labeled with europium (Eu(3+)). The labeling protocol did not significantly alter the gp120 binding properties or the antiviral activity of CV-N. This report describes the assay development, validation, and results of screening a large library of aqueous and organic natural product extracts. The extracts were incubated with immobilized recombinant gp120 in 96-well plates prior to the addition of Eu(3+)-labeled CV-N. Following a wash step, bound CV-N was measured by dissociation-enhanced time-resolved fluorometry of Eu(3+). The assay proved to be robust, rapid, and reproducible, and was used to screen over 50,000 natural product extracts, and has resulted in the identification of several aqueous natural product extracts that inhibited CV-N-gp120 binding and also had anti-HIV activity.

Anti-HIV Agents↗

Assay for ubiquitin ligase activity: high-throughput screen for inhibitors of HDM2.

An assay for the autoubiquitination activity of the E3 ligase HDM2 (Mdm2) was developed and adapted to a high-throughput format to identify inhibitors of this activity. The assay can also be used to measure the activity of other E3s and may be useful in finding both inhibitors and activators of a wide range of different ubiquitin ligases.

Animals↗

Eukaryotic arylamine N-acetyltransferase. Investigation of substrate specificity by high-throughput screening.

Arylamine N-acetyltransferases (NAT; EC 2.3.1.5) catalyse the transfer of acetyl groups from acetylCoA to xenobiotics, including drugs and carcinogens. The enzyme is found extensively in both eukaryotes and prokaryotes, yet the endogenous roles of NATs are still unclear. In order to study the properties of eukaryotic NATs, high-throughput substrate and inhibitor screens have been developed using pure soluble recombinant Syrian hamster NAT2 (shNAT2) protein. The assay can be used with a wide range of compounds and was used to determine substrate specificity of shNAT2. We describe the expression and characterisation of shNAT2 and also purified recombinant human NAT1 and NAT2, including the use of the assay to explore the substrate specificities of each of the enzymes. Hamster NAT2 has similar substrate specificity to human NAT1, acetylating para-aminobenzoate but not arylhydrazine and hydralazine compounds. The overlapping but distinct substrate-specific activity profiles of human NAT1 and NAT2 were clearly observed from the screen. Naturally occurring compounds were tested as substrates or inhibitors of shNAT2 and succinylCoA was found to be a potent inhibitor of shNAT2.

Animals↗

High throughput screens for the identification of compounds that alter the accumulation of the Alzheimer's amyloid beta peptide (Abeta).

Evidence gathered over the last two decades suggests that beta amyloid (Abeta), the predominant proteinaceous component of senile plaques, plays an early and critical role in the etiology and pathogenesis of Alzheimer's disease (AD). Thus, it is reasonable to hypothesize that compounds capable of reducing the accumulation of Abeta may be of value therapeutically. Additionally, compounds that influence Abeta accumulation may be useful as tools to further dissect the cellular pathways that regulate Abeta production and accumulation. To screen for compounds that affect Abeta levels, we have established high throughput, cell-based assays capable of the sensitive and selective detection of Abeta40 in parallel with the more amyloidogenic form of the peptide, Abeta42. To validate the approach, we examined the effects of several compounds previously identified to influence Abeta accumulation. Analysis of peptide accumulation following treatment with these compounds showed results similar to those previously published. Currently, we are using this assay to screen drugs that have already received FDA approval for the treatment of other diseases and over-the-counter natural product extracts. If compounds such as these can be identified that lower Abeta in the brain, they may represent one of the fastest and most cost effective methods to therapy.

Alzheimer Disease↗

Denaturing HPLC for high-throughput screening of rifampicin-resistant Mycobacterium tuberculosis isolates.

OBJECTIVE: To evaluate the use of denaturation high-performance liquid chromatography (dHPLC) as a rapid method to detect rifampicin (RMP) resistance based on mutations in the rpoB gene in a high-volume laboratory setting. METHODS: A total of 132 RMP-resistant Mycobacterium tuberculosis strains with different rpoB mutation were used to optimise the running condition of dHPLC as a pilot study. A blind correlation study was subsequently done between dHPLC and in vitro RMP susceptibility tests on 3167 M. tuberculosis strains in a high-throughput clinical setting. RESULTS: In the pilot study, rpoB mutation could be detected on 116/132 (87.9%) RMP-resistant strains by dHPLC. In the second phase of the study, 84/3107 (2.7%) clinical M. tuberculosis isolates were RMP-resistant. The sensitivity and specificity of dHPLC in the prediction of RMP resistance were 70/84 (83.3%) and 70/77 (91.0%), respectively. The specificity became 100% when 511 Leu to Pro mutation was excluded from the RMP resistance-related genetic changes. CONCLUSION: In the detection of RMP resistance in a high-throughput laboratory setting, dHPLC has been demonstrated to be rapid, simple, workable, automatable and inexpensive in terms of running costs and the labour involved.

Bacterial Proteins↗

Fluorescein-labeled beta-lactamase mutant for high-throughput screening of bacterial beta-lactamases against beta-lactam antibiotics.

The increasing emergence of new bacterial beta-lactamases that can efficiently hydrolyze beta-lactam antibiotics to clinically inactive carboxylic acids has created an intractable problem in the treatment of bacterial infections, and it is highly desirable to develop a useful tool that can rapidly screen bacteria for beta-lactamases against a variety of antibiotic candidates in a high-throughput manner. This paper describes the use of a fluorescein-labeled beta-lactamase mutant (E166Cf) as a convenient fluorescent tool to screen beta-lactamases, including the Bacillus cereus beta-lactamase I (PenPC), B. cereus beta-lactamase II, Bacillus licheniformis PenP, Escherichia coli TEM-1, and Enterobacter cloacae P99 against various beta-lactam antibiotics (penicillin G, penicillin V, ampicillin, cefuroxime, cefoxitin, moxalactam, cephaloridine), using a 96-well microplate reader. The E166Cf mutant was constructed by replacing Glu166 on the flexible Omega-loop, which is close to the enzyme's active site, with a cysteine residue on a class A beta-lactamase (B. cereus PenPC) and subsequently labeling the mutant with thiol-reactive fluorescein-5-maleimide. Such modifications significantly impaired the hydrolytic activity of the E166Cf mutant compared to that of the wild-type enzyme. The fluorescence intensity of the E166Cf mutant increases in the presence of beta-lactam antibiotics. For antibiotics that are resistant to hydrolysis by the E166Cf mutant (cefuroxime, cefoxitin, moxalactam), the fluorescence signal slowly increases until it reaches a plateau. For antibiotics that can be slowly hydrolyzed by the E166Cf mutant (penicillin G, penicillin V, ampicillin), the fluorescence signal rapidly increases to the plateau and then declines after a prolonged incubation. The E166Cf mutant retains its characteristic pattern of fluorescence signals in the presence of both bacterial beta-lactamases and beta-lactamase-resistant antibiotics. In contrast, in the presence of both bacterial beta-lactamases and beta-lactamase-sensitive antibiotics, the fluorescence signals of the E166Cf mutant were decreased. The fluorescence signals from the E166Cf mutant allow an unambiguous differentiation of beta-lactamase-resistant antibiotics from beta-lactamase-sensitive ones in the screening of bacterial beta-lactamases against a panel of antibiotic candidates. This simple method may provide an alternative tool in choosing potent beta-lactam antibiotics for treatment of bacterial infections.

Animals↗

High-throughput screening of protein surface activity via flow injection analysis-pH gradient-dynamic surface tension detection.

Using flow injection analysis (FIA), a pH gradient is blended in real time with a protein sample as the pH-dependent protein surface activity is measured by a dynamic surface tension detector (FIA-pH-DSTD). This instrumental system was developed as a high-throughput method for the screening of protein surface activity at the air/liquid interface as a function of pH. This method utilizes the continuous flow, drop-based dynamic surface tension detector in combination with flow injection sample introduction and blending of a steady-state concentration of protein sample with a pH gradient ranging from pH 2.0 to pH 11.5. Dynamic surface tension is measured through the differential pressure across the air/liquid interface of repeatedly growing and detaching drops. Continuous surface tension measurement is achieved for each eluting drop of 2-s length (2 muL), providing insight into both the kinetic and thermodynamic behaviors of molecular orientation processes at the liquid/air interface. Three-dimensional data are obtained, with surface tension first converted to surface pressure, which is collected as a function of elution time versus drop time. In FIA-pH-DSTD, a commercial pH probe is used to measure pH during elution time, enabling surface pressure throughout drop time to be subsequently plotted as a function of eluting pH. An automated DSTD calibration procedure and data analysis method is applied, which allows simultaneous use of two different solvents, permitting real-time dynamic surface tension data to be obtained. The method was applied to the analysis of 14 commercial purified proteins, yielding characteristic features of surface activity as a function of pH. The reproducibility of the measurement and selectivity advantage of the DSTD was shown for the analysis of serum albumins from various mammalian sources. Several applications were also suggested and discussed in order to show the potential of the method for protein and food chemistry studies and in the study of protein-polymer interactions.

Journal Article↗

Flux assays in high throughput screening of ion channels in drug discovery.

Ion channels have been identified as therapeutic targets in various disorders, such as cardiovascular disease, neurological disease, and cystic fibrosis. Flux assays to detect functional ionic flux through ion channels are becoming increasingly popular as tools for screening compounds. In an optimized flux assay, modulation of ion channel activity may produce readily detectable changes in radiolabeled or nonradiolabeled ionic flux. Technologies based on flux assays are currently available in a fully automated high throughput format for efficient screening. This application offers sensitive, precise, and reproducible measurements giving accurate drug rank orders matching those of patch clamp data. Conveniently, the flux assay is amenable to adaptation for different ion channels, such as potassium, sodium, calcium, and chloride channels, by using suitable tracer ions. The nonradiolabeled rubidium-based flux assay coupled with the ion channel reader (ICR) technology has become very successful in ion channel activity analysis and is emerging as a popular technique in modern drug discovery.

Animals↗