Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “FLUOROSCOPY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Dynamic radiography. An evaluation of cardiac motion by the analysis of scattered radiation during fluoroscopy.

A non-invasive technique, utilizing scattered radiation, has been developed to monitor and measure the motion of the epicardial surface during fluoroscopy. A number of dogs were studied using a monitoring device which consists of an X-Ray beam collimator, collimated sodium iodide dectetors and their associated electronics. The detector signals are computer processed to obtain frequency fingerprints of epicardial motion that may, in the future, indicate the condition of the myocardium.

Computers↗

Real-time digital K-edge subtraction fluoroscopy.

We report in vitro and in vivo trials of K-edge fluoroscopy, by which iodine contrast concentration is displayed live, with tissue and bone images suppressed, free of patient-motion artifacts. Iodine and cerium, 125 and 225 mg/cm2 respectively, filter alternate TV fields of cine-pulsed 50 KVP x-rays. Weighted subtraction of successive TV fields isolates the iodine image and simultaneously minimizes artifacts. Digital techniques are used in real time. At our present x-ray tube limit, 500 mA instantaneous current, the patient exposure is 180 mR/sec and quantum mottle limits the image quality. Integrating four successive difference images provides a compromise between mottle and smoothly moving displays. Cardiovascular images of a 17-kg dog, using 1 ml/kg Renografin-60 injected into a foreleg vein, show that a 15-cm chest thickness is our present practical maximum. This method may be useful in diagnosing cardiovascular anomalies in infants without catheterization or suspension of breathing.

Animals↗

A fluoroscopy-based computed tomography scanner for small specimen research.

RATIONALE AND OBJECTIVES: A small-laboratory computed tomography (CT) system using a fluoroscopic system and a personal computer was fabricated and tested. The motivation for building this specimen scanner was to provide medical researchers with the capability of using CT as a practical tool in their research, as well as to provide an opportunity for hands-on CT instruction. METHODS AND MATERIALS: The CT system was constructed using mostly off-the-shelf items; however, the CT stage itself was custom fabricated and software development was necessary. In addition, a personal computer and a standard fluoroscopy system were used. RESULTS: The spatial resolution was found to match the 228-microns sampling limitation, yielding approximately 2 line pairs per mm. Iodine contrast sensitivity studies showed that 1% solution of 370 mg/ml iodine solution was easily detected (P = .05). CONCLUSIONS: A small CT scanner for specimen research can be economically constructed, and is capable of good performance. The authors found substantial interest on the part of small animal researchers involved in a wide variety of medical research.

Animals↗

Large core biopsy of the pancreas under CT fluoroscopy control: results and complications.

PURPOSE: The objective of this study was to evaluate the accuracy and complication rate of CT fluoroscopy-guided percutaneous core biopsies of the pancreas in patients with a suspected pancreatic neoplasm. MATERIALS AND METHODS: Sixty-three CT-guided biopsies were performed in 57 consecutive patients over a period of 20 months. Forty-nine of the 57 patients had a malignant lesion (85.9%). All procedures were done under CT fluoroscopic guidance. A high-speed biopsy gun with 14, 16, or 18 gauge cutting-type needles was used. Based on final pathologic diagnosis as the standard of reference, the diagnostic efficacy was determined. Complications during and afterward up to the patient's discharge from hospital (mean, 8.1 days; range, 1-48 days) were noted. RESULTS: Core biopsy of the pancreas resulted in a correct diagnosis in 51 of 63 biopsies, yielding a sensitivity for malignancy of 78.1%, a specificity of 100%, a positive predictive value of 100%, and an overall accuracy of 81.0%. One patient of 57 developed an acute pancreatitis related to the biopsy (1.6%). CONCLUSION: CT fluoroscopic-guided core biopsy is a safe and reliable tool for the pretherapeutic evaluation of pancreatic lesions.

Adult↗

A preliminary report of percutaneous cholecystostomy under ultrasonography and fluoroscopy guidance.

We carried out percutaneous cholecystostomy and cholangiography without incident under guidance of ultrasonography and fluoroscopy in three patients with obstructive jaundice, cholangitis, and acute cholecystitis. The technique appears to be safe and can be performed at the patient's bedside, which gives it an advantage over surgical drainage. Moreover, the percutaneous route can be used for biliary drainage when the transhepatic approach is not possible.

Aged↗

Esophageal dilation can be done safely using selective fluoroscopy and single dilating sessions.

Maxims for safe esophageal dilation have included recommendations to use fluoroscopy in all instances and to limit dilation sessions to 2-mm increments. We reviewed a 34-month experience of all esophageal dilations undertaken at a large multispecialty clinic to define adherence to these recommendations and to delineate whether deviation was associated with significant complications. Four hundred thirty-two patients underwent 716 courses of esophageal dilation during this time, 92% of whom had benign disease. Eighty-nine percent of patients were dilated with polyvinyl dilators (Savary/American) and only 8% of these patients required fluoroscopic monitoring for the bougienage. Seventy-eight percent of the dilating sessions for patients without achalasia were undertaken using either a single large dilator (> or = 45 Fr) or employed incremental dilator sizes > 2 mm (6 Fr) in a single session. There was a single perforation in 662 nonachalasia dilations and this was a consequence of attempted placement of an esophageal endoprosthesis. We conclude that use of guide wire technology and newer dilating techniques do away with the need for routine fluoroscopic control. Moreover, single large dilators or dilator increments > 2 mm may be safely used, contingent on endoscopic stricture assessment.

Dilatation↗

Stereo fluoroscopy-assisted distal interlocking of intramedullary nails.

A simulation study of distal interlocking of an intramedullary nail was performed using newly devised, portable stereo fluoroscopy. Two intramedullary nails in which ten holes were drilled perpendicular to the long axis and at various angles to the diameter were inserted into a femoral and a tibial bone model. Ten drill bits were drilled freehand into the holes in the nail with the aid of the stereo fluoroscope. All twenty drill bits were seated in the holes in the first attempt. This instrument provides a three-dimensional view in real time, which enables the surgeon to appreciate the three-dimensional relationship between the drill bit and the hole in the nail in the bone model. Distal interlocking of the intramedullary nail is facilitated with the aid of this stereo fluoroscope.

Bone Nails↗

Percutaneous approach to the renal pelvis: combined use of ultrasonography and fluoroscopy.

The percutaneous approach to the renal pelvis provides access for antegrade urography, percutaneous nephrostomy, or endourologic manipulation. Having performed 31 successful procedures, including the percutaneous placement of double-pigtail ureteral stents for ureterovesical obstruction, we advocate the combined use of ultrasonography and fluoroscopy to achieve optimal results.

Adolescent↗

The role of fluoroscopy in cervical epidural steroid injections: an analysis of contrast dispersal patterns.

STUDY DESIGN: A multicenter, retrospective analysis of cervical epidurograms. OBJECTIVES: To determine the effectiveness of the loss of resistance (LOR) technique in identifying the cervical epidural space. To delineate the pattern of epidural contrast spread during cervical epidural steroid injections. BACKGROUND: Previous studies have shown that if performed without fluoroscopy, the LOR technique can result in inaccurate needle placement in up to 30% of lumbar epidural steroid injections. To date, no study has examined accuracy of LOR technique and pattern of radiographic contrast spread in cervical epidural levels. METHODS: Epidurograms of 38 cervical epidural steroid injections in 31 patients were reviewed. The number of LOR attempts and pattern of contrast spread was analyzed. The effects of age, gender, MRI results, previous cervical laminectomy, and the physician's level of training were correlated with results. RESULTS: The authors found a 53% rate of false LOR during the first attempt to enter the epidural space. Unilateral epidural contrast spread was found in 51% and ventral epidural spread was found in 28% of cases. The average number of cervical vertebral levels covered with 2 mL of contrast was 3.14, with significantly wider spread noted in those patients who had not undergone previous cervical laminectomy. Other variables did not influence the accuracy of needle placement and pattern of epidural contrast spread. CONCLUSIONS: The loss of resistance technique may not be an adequate method for ensuring accurate needle placement in blindly performed cervical epidural injections. The use of epidurography can improve the accuracy of needle placement and medication delivery to targeted areas of pathology.

Adult↗

Percutaneous placement of posterior cervical screws using three-dimensional fluoroscopy.

STUDY DESIGN: The placement of percutaneous posterior cervical screws using three-dimensional fluoroscopic guidance was performed in intact human cadaver specimens. OBJECTIVES: To determine the accuracy and feasibility of placing entirely percutaneous posterior cervical screws using a novel form of spinal image guidance. SUMMARY OF BACKGROUND DATA: Conventional image guidance has been shown to increase the accuracy of many open cervical instrumentation procedures. There are presently no published studies reporting this novel method for guiding the percutaneous placement of posterior cervical screws. METHODS: An isocentric C-arm was used to obtain CT images of three intact cadaver specimens. A percutaneous dynamic reference array was attached to the C2 spinous process of each specimen. Light-emitting diodes attached to the C-arm were tracked with an electro-optical camera. The image data set was then transferred to the image-guided workstation, which performed an automated registration. Using the workstation, trajectories were planned for bilateral C1-C2 transarticular, C3-C6 lateral mass, and C7 pedicle screw placement. Through 1.5-cm incisions, a drill guide fitted with light-emitting diodes was used for sequential, image-guided drilling, tapping, and placement of cannulated 4.0 mm screws at each level. Postprocedure, thin-cut CT scanning was used to determine the accuracy of screw placement. RESULTS: A total of 41 of 42 percutaneous screws (97.6%) were accurately placed. All of the transarticular atlantoaxial and subaxial lateral mass screws showed no evidence of foramen transversarium, neural foramen, or facet joint violation. One of the C7 pedicle screws had a minor cortical wall violation. CONCLUSION: This study demonstrates the feasibility of placing percutaneous posterior cervical screws. Three-dimensional fluoroscopy appears to enable highly accurate, percutaneous three-dimensional cervical spine navigation.

Bone Screws↗

An iterative algorithm for X-ray CT fluoroscopy.

X-ray computed tomography fluoroscopy (CTF) enables image guidance of interventions, synchronization of scanning with contrast bolus arrival, and motion analysis. However, filtered backprojection (FB), the current method for CTF image reconstruction, is subject to motion and metal artifacts from implants, needles, or other surgical instruments. Reduced target lesion conspicuity may result from increased image noise associated with reduced tube current. In this report, we adapt the row-action expectation-maximization (EM) algorithm for CTF. Because time-dependent variation in images is localized during CTF, the row-action EM-like algorithm allows rapid convergence. More importantly, this iterative CTF algorithm has fewer metal artifacts and better low-contrast performance than FB.

Algorithms↗

A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.

A method was developed for registering three-dimensional knee implant models to single plane X-ray fluoroscopy images. We use a direct image-to-image similarity measure, taking advantage of the speed of modern computer graphics workstations to quickly render simulated (predicted) images. As a result, the method does not require an accurate segmentation of the implant silhouette in the image (which can be prone to errors). A robust optimization algorithm (simulated annealing) is used that can escape local minima and find the global minimum (true solution). Although we focus on the analysis of total knee arthroplasty (TKA) in this paper, the method can be (and has been) applied to other implanted joints, including, but not limited to, hips, ankles, and temporomandibular joints. Convergence tests on an in vivo image show that the registration method can reliably find poses that are very close to the optimal (i.e., within 0.4 degrees and 0.1 mm), even from starting poses with large initial errors. However, the precision of translation measurement in the Z (out-of-plane) direction is not as good. We also show that the method is robust with respect to image noise and occlusions. However, a small amount of user supervision and intervention is necessary to detect cases when the optimization algorithm falls into a local minimum. Intervention is required less than 5% of the time when the initial starting pose is reasonably close to the correct answer, but up to 50% of the time when the initial starting pose is far away. Finally, extensive evaluations were performed on cadaver images to determine accuracy of relative pose measurement. Comparing against data derived from an optical sensor as a "gold standard," the overall root-mean-square error of the registration method was approximately 1.5 degrees and 0.65 mm (although Z translation error was higher). However, uncertainty in the optical sensor data may account for a large part of the observed error.

Algorithms↗

Percutaneous nephrostomy under guidance of ultrasonography and fluoroscopy using a pigtail catheter.

Percutaneous nephrostomy using a pigtail catheter was performed in 37 patients under the guidance of ultrasonography and fluoroscopy. The only failure in 60 attempts was due to a subcapsular haematoma. The catheter appears to be well tolerated and is large enough for good drainage. Ultrasonography has proved to be a valuable part of this technique and has made antegrade pyelography easy.

Adolescent↗

Comparison of echocardiography-guided and fluoroscopy-guided endomyocardial biopsy techniques.

The accuracy of bioptome placement for endomyocardial biopsy was evaluated using standard fluoroscopic guidance and compared simultaneously with two-dimensional echocardiography in six healthy subadult grizzly bears (Ursus arctos horribilis). Despite perceived adequate positioning of the bioptome toward the septum when judged using fluoroscopy, only one out of the six placements were actually positioned in the right ventricular apex toward the septum when evaluated using two-dimensional echocardiography. The bioptome was readily relocated to the right ventricular apex/septal location by echocardiography. The forceps were easily visualized at all times and the open cups were readily directed into the desired location for biopsy. Based on a subjective score for tissue quantity from 1 to 4 (poor to excellent), biopsies collected by echocardiographic-guided technique had a mean score of 3.4, while biopsies collected by fluoroscopic-guided technique had a mean score of 1.8. In summary, this study suggests that endomyocardial biopsy locations can be accurately positioned using two-dimensional echocardiography with the advantages of less radiation, lower procedural costs, and direct visualization of the sampling site. Clear definition of endocardial surface as afforded by echocardiography may enhance tissue sample quality and lower potential complications from this procedure.

Animals↗

The role of fluoroscopy in the removal of tracheobronchial pin aspiration.

In this study, we investigated the role of fluoroscopy in the bronchoscopic removal of aspirated pins. Of 373 patients who underwent bronchoscopy for presumed tracheobronchial foreign body aspiration, 56 pin aspiration cases were selected and divided into two groups according to whether fluoroscopic guidance was required (group I) or not (group II). The localisation of foreign bodies, mortality and morbidity ratios and the duration of the procedures were investigated. Pin aspiration percentage was 15. Pins were mostly located in peripheral airways in group I, and in central airways in group II (p < 0.05). The mean duration of the procedure was 42 +/- 30 min in group I and 17 +/- 13 min in group II (p < 0.01). There was no mortality. Morbidity percentage was 7 in group I and 12 in group II (p > 0.05). No thoracotomy was required in any cases. Fluoroscopic guidance is safe and carries no additional morbidity and mortality and can be used for pins in the tracheobronchial tree.

Adolescent↗

Tracheal foreign bodies in the cat and the use of fluoroscopy for removal: 12 cases.

OBJECTIVES: To gather information to support the use of fluoroscopically guided removal of tracheal foreign bodies in cats. It was also the intent to produce a case series and look at the long-term outcome following tracheal foreign body removal. METHODS: A retrospective study was performed. This looked at cases of tracheal foreign bodies in cats seen at the University of Bristol veterinary school at Langford over an eight-year period. Outcome was assessed via telephone conversations with the owners. RESULTS: Twelve cats were presented with tracheal foreign bodies during this time. Ten of these foreign bodies were successfully removed using fluoroscopy and two using bronchoscopy. All cats survived. Follow-up was available for nine cats and showed no long-term complications. CLINICAL SIGNIFICANCE: Forceps removal under fluoroscopic guidance is a rapid, safe, and effective method for removal of tracheal foreign bodies in cats. It should be considered as an alternative to bronchoscopy for removal of tracheal foreign bodies in cats. Indeed, in cases where bronchoscopy has failed, it can be attempted to avoid thoracotomy. Successful removal of tracheal foreign bodies in cats is associated with a good long-term outcome.

Animals↗

Measurement of the dose deposition characteristics of x-ray fluoroscopy beams in water.

The purpose of this study was to characterize the x-ray dose distribution of fluoroscopy beams by measuring their percent depth dose curves and lateral dose profiles in a water phantom. Percent depth dose curves were measured near the surface with an Attix parallel plate chamber and deep within the water phantom with a Farmer-type cylindrical chamber. Percent depth dose curves were compared to published data where applicable. Lateral dose profiles were measured at depths of 2, 5, 10, and 15 cm in phantom with a Farmer chamber. Pulsed, 50 mA x-ray beams with peak tube potentials of 60, 80, 100, and 120 kV and half value layers of 1.89, 2.52, 3.20, and 4.09 mm Al, respectively, were investigated.

Biophysical Phenomena↗