Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Confocal microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

From cells to tissues: fluorescence confocal microscopy in the study of histological samples.

Our knowledge of the genetic mechanisms controlling cell proliferation and differentiation usually originates from in vitro cultured cell line models. However, the definition of the molecular switches involved in control of homeostasis and the understanding of the changes occurring in neoplastic transformation require looking at single cells as the components of a complex tissue network. Histological examination of tissue samples can gain a substantial amount of information from high-resolution fluorescence analysis. In particular, confocal microscopy can help in the definition of functional pathways using multiparameter analysis. In this report, we present acquisition and analysis procedures to obtain high-resolution data from tissue sections. Confocal microscopy coupled to computational restoration, statistical evaluation of spatial correlations, and morphological analysis over large tissue areas were applied to colorectal samples providing a molecular fingerprint of the biological differences inferred from classical histological examination.

Animals↗

Visualization of exocytosis during sea urchin egg fertilization using confocal microscopy.

A Ca2+ wave at fertilization triggers cortical granule exocytosis in sea urchin eggs. New methods for visualizing exocytosis of individual cortical granules were developed using fluorescent probes and confocal microscopy. Electron microscopy previously provided evidence that cortical granule exocytosis results in the formation of long-lived depressions in the cell surface. Fluorescent dextran or ovalbumin in the sea water seemed to label these depressions and appeared by confocal microscopy as disks. FM 1-43, a water-soluble fluorescent dye which labels membranes in contact with the sea water, seemed to label the membrane of these depressions and appeared as rings. In double-labeling experiments, the disk and ring labeling by the two types of fluorescent dyes were coincident to within 0.5 second. The fluorescent labeling is coincident with the disappearance of cortical granules by transmitted light microscopy, demonstrating that the labeling corresponds to cortical granule exocytosis. Fluorescent labeling was simultaneous with an expansion of the space occupied by the cortical granule, and labeling by the fluorescent dextran was found to take 0.1-0.2 second. These results are consistent with, and reinforce the previous electron microscopic evidence for, long-lived depressions formed by exocytosis; in addition, the new methods provide new ways to investigate cortical granule exocytosis in living eggs. The fluorescence labeling methods were used with the Ca2+ indicator Ca Green-dextran to test if Ca2+ and cortical granule exocytosis are closely related spatially and temporally. In any given region of the cortex, Ca2+ increased relatively slowly.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Confirmation of confocal microscopy diagnosis of Acanthamoeba keratitis using polymerase chain reaction analysis.

BACKGROUND: Acanthamoeba keratitis has commonly been identified with in vivo confocal microscopy and confirmed with histologic examination of an epithelial biopsy specimen. OBJECTIVE: To determine if Acanthamoeba keratitis can be verified using polymerase chain reaction (PCR) of epithelial biopsy specimens. METHODS: Epithelial specimens from patients with suspected Acanthamoeba keratitis by confocal microscopy were tested for Acanthamoeba with PCR of Acanthamoeba ribosomal DNA. RESULTS: Twenty-four of 31 patients with evidence of Acanthamoeba keratitis were positive for Acanthamoeba on PCR analysis using 3 sets of primers. In 22 cases, the sequence obtained closely matched Acanthamoeba castellanii. CONCLUSIONS: This study demonstrates that PCR analysis of epithelial biopsy specimens can provide definitive verification of the confocal microscopic and histologic identification of Acanthamoeba organisms associated with keratitis. Acanthamoeba keratitis is probably quite common, especially in contact lens wearers, although more than half of the patients in this study did not wear contact lenses.

Acanthamoeba↗

DNA staining for fluorescence and laser confocal microscopy.

We examined five nucleic acid binding fluorescent dyes, propidium iodide, SYBR Green I, YO-PRO-1, TOTO-3, and TO-PRO-3, for nuclear DNA staining, visualized by fluorescence and laser confocal microscopy. The optimal concentration, co-staining of RNA, and bleaching speeds were examined. SYBR Green I and TO-PRO-3 almost preferentially stained the nuclear DNA, and the other dyes co-stained the cytoplasmic RNA. RNAse treatment completely prevented the cytoplasmic RNA staining. In conventional fluorescence microscopy, these dyes can be used in combination with fluorescence-labeled antibodies. Among the dyes tested, TOTO-3 and TO-PRO-3 stained the DNAs with far-red fluorescence under red excitation. Under Kr/Ar-laser illumination, TOTO-3 and TO-PRO-3 were best suited as the nuclear staining dyes in the specimens immunolabeled with fluorescein and rhodamine (or Texas red).

Animals↗

Immunolocalisation of neuronal nitric oxide synthase at the neuromuscular junction of MDX mice: a confocal microscopy study.

The distribution of nitric oxide synthase at the neuromuscular junction (NMJ) of normal, denervated and mdx mice was studied using a specific antibody against the neuronal isoform of nitric oxide synthase (nNOS). Fluorescence confocal microscopy demonstrated that nNOS immunoreactivity was localised mainly in the sarcolemma and presynaptic region covering acetylcholine receptor branches. The expression of presynaptic nNOS was greatly reduced in dystrophin-deficient muscles. In normal denervated muscles, nNOS was still present in the presynaptic region and there were no qualitative changes in the expression of this protein. These results suggest that the presynaptic distribution of nNOS is associated with terminal Schwann cells. The relationship between nNOS and the presynaptic components of the neuromuscular junction may open new perspectives for improving our understanding of the pathogenesis of dystrophic muscles.

Animals↗

4Pi-confocal microscopy provides three-dimensional images of the microtubule network with 100- to 150-nm resolution.

We show the applicability of 4Pi-confocal microscopy to three-dimensional imaging of the microtubule network in a fixed mouse fibroblast cell. Comparison with two-photon confocal resolution reveals a fourfold better axial resolution in the 4Pi-confocal case. By combining 4Pi-confocal microscopy with Richardson-Lucy image restoration a further resolution increase is achieved. Featuring a three-dimensional resolution in the range 100-150 nm, the 4Pi-confocal (restored) images are intrinsically more detailed than their confocal counterparts. Our images constitute what to our knowledge are the best-resolved three-dimensional images of entangled cellular microtubules obtained with light to date.

3T3 Cells↗

[Observation of the cornea with confocal microscopy after Nd:YAG laser capsulotomy].

PURPOSE: The purpose of the study was to evaluate the influence of Nd:YAG capsulotomy on the cornea structure assessed by scanning slit confocal microscopy. MATERIAL AND METHODS: 14 eyes in 14 patients after Nd:YAG laser capsulotomy performed 6-34 months after extracapsular cataract extraction with PCIOL implantation were observed. Structure of cornea layers was evaluated before the procedure, then 3 hours and 7 days after the laser exposition using confocal microscope. RESULTS: Initial evaluation showed degenerative changes in subepithelial plexus; 3 hours after the procedure excessive exfoliation of superficial epithelial cells was observed. No significant changes were registered 7 days after the procedure. CONCLUSION: No significant changes were found in the confocal microscopy images of cornea after Nd:YAG capsulotomy.

Aged↗

Differences in laser-induced autofluorescence between adenomatous and hyperplastic polyps and normal colonic mucosa by confocal microscopy.

Laser-induced autofluorescence has been used to discriminate normal from adenomatous colonic mucosa. However, few studies to date have studied the origin of colonic autofluorescence. Using confocal microscopy (excitation wavelength 488 nm), we have shown that autofluorescence at this wavelength is present predominantly in the lamina propria of normal mucosa but in the epithelium in adenomatous and hyperplastic polyps. The intensity ratio of epithelial cell to lamina propria fluorescence was significantly lower (P < 0.0001) in normal mucosa (0.52 +/- 0.01) compared with either adenomatous (1.6 +/- 0.2) or hyperplastic polyps (1.7 +/- 0.15). However, the ratios were not significantly different between hyperplastic and adenomatous polyps. Thus, confocal microscopy enables the detection of the sites of autofluorescence within colonic mucosa and the quantitation of differences in fluorescence between different tissue types.

Adenomatous Polyps↗

Four-dimensional multiphoton confocal microscopy: the new frontier in cellular imaging.

This paper reviews new developments in microscopy that combine gene transfer technology, multiphoton confocal fluorescence microscopy, live cell imaging and digital imaging techniques that provide unique insights into the complex physiological processes involved in tissue function at the cellular and subcellular level. The evolution of this novel, new technology is discussed with particular attention to earlier achievements in noninvasive ocular surface imaging. The practical basis of confocal microscopy, multiphoton confocal fluorescence microscopy, and the vital fluorescent labeling of cells in living tissues are also discussed. Additionally, one application using retroviral gene transfer to express enhanced green fluorescent protein in living wound healing fibroblasts is presented as an example of how living biology can be studied in situ in four dimensions (x, y, z, time).

Journal Article↗

Fiber-optic monitoring coupled with confocal microscopy for imaging gene expression in vitro and in vivo.

Detection of fluorescent signals in living cells is a common and powerful technique used to monitor gene expression for multiple biomedical applications. A disadvantage of this approach in vivo, is the limited accessibility for long-term monitoring of the fluorescent signals within organs in living animals. Because of the multiple applications of gene expression monitoring through fluorescent signals, innovative methods for readout are required. We developed a strategy combining gene transfer, fiber-optic or endoscope monitoring, and confocal microscopy for the brain interstitial or cavitary endoscopic visualization of the efficacy of gene delivery and expression in vivo. The approach is also effective in vitro and can be applied to multiple organs in vivo. We show an example of the detection of green fluorescent protein (GFP)-emitted fluorescence following the administration of recombinant GFP-expressing adenovirus or implantation of rat C6 glioblastoma cells infected with the recombinant GFP adenovirus into the rat hippocampus of chronically cannulated rats. The results show that fiber-optic monitoring coupled with confocal microscopy in gene transfer studies is a practical approach that results in a direct, efficient, rapid, and sensitive visualization of fluorescent signals in the brain. This allows for the continuous real-time in vitro or in vivo brain monitoring of gene expression, accurate anatomical localization, multiple experimental manipulations in the same subject or preparation, while no sacrifice of the animal is required to monitor the efficacy of gene transfer and/or expression.

Animals↗

In vivo confocal microscopy of corneal wound healing after excimer laser photorefractive keratectomy.

We used real-time scanning confocal microscopy to evaluate early changes in corneal wound healing after excimer laser photorefractive keratectomy (PRK). Adult New Zealand White rabbits were given photorefractive keratectomy treatments appropriate for 5.00 to 8.00 D of myopia (44.5 to 71.0 micros depth, with a 5-mm diameter treatment zone). Daily confocal microscopic examinations showed acute loss of keratocytes in the anterior corneal stroma by 5 hours; losses were maximal between 24 and 48 hours for 5.00 D and 6.00 D ablations and between 72 and 96 hours for 7.00 D and 8.00 D ablations. The oval nuclei of normal keratocytes gave way to spindle-shaped fibroblasts accompanied by an accumulation of fibrillary extracellular matrix. Fibroblasts density increased toward the end of the week. Deeper ablations resulted in a longer period of keratocyte depletion and delayed onset of fibroblast activity. No epithelial, deep stromal, or endothelial abnormalities were detected, nor was stromal inflammation found. Light microscopy 1 week after PRK revealed superficial fibroplasia, which correlated with the en face images obtained with real-time in vivo confocal microscopy. The confocal microscope has a number of advantages as a clinical tool for investigation of laser-induced changes in corneal keratocytes and the stromal matrix, which may play a role in determining visual outcome after PRK.

Animals↗

Differential localization of cysteine protease inhibitors and a target cysteine protease, cathepsin B, by immuno-confocal microscopy.

The cystatin superfamily of cysteine protease inhibitors and target cysteine proteases such as cathepsin B have been implicated in malignant progression. The respective cellular/extracellular localization of cystatins and cysteine proteases in tumors may be critical in regulating activity of the enzymes. Confocal microscopy has enabled us to demonstrate the differential localization of cystatins and cathepsin B in an embryonic liver cell line and an invasive hepatoma cell line. In both, stefins A and B were distributed diffusely throughout the cytoplasm, whereas cystatin C was distributed in juxtanuclear vesicles. Stefin A and cystatin C, but not stefin B, were present on the cell surface. Cystatin C was found on the top surfaces of both cell lines, whereas stefin A was found only on the top surface of the embryonic liver cells. Cathepsin B staining was concentrated in perinuclear vesicles in the embryonic liver cells. In the hepatoma cells, staining for cathepsin B was also present in vesicles adjacent to the cell membrane and on localized regions of the bottom surface. Such a disparate distribution of cathepsin B and its endogenous inhibitors may facilitate proteolysis by the hepatoma cells and thereby contribute to their invasive phenotype.

Animals↗

Changes in yolk platelet pH during Xenopus laevis development correlate with yolk utilization. A quantitative confocal microscopy study.

The variations of the pH in Xenopus yolk platelets have been estimated by fluorescence confocal microscopy and computer image processing. For pH measurements in vitellogenic oocytes, the pH-sensitive fluorescent dye, DM-NERF, was coupled to vitellogenin, and the DM-NERF-vitellogenin was taken up by oocytes via receptor-mediated endocytosis. Dual emission ratio measurements of internalized DM-NERF-vitellogenin indicated that the mature yolk platelets are mildly acidic (pH 5.6). Their precursors, the primordial yolk platelets, have a similar pH. This pH is probably sufficiently low for the partial cleavage of vitellogenin to yolk proteins, but not for yolk degradation. The yolk platelet pH at various developmental stages was estimated by measuring the accumulation of Acridine Orange, both in isolated yolk platelets and in disaggregated embryonic cells. During oogenesis, the yolk platelets accumulated a constant amount of Acridine Orange, corresponding to a pH of around 5.7. During embryogenesis, however, yolk platelets became progressively much more acidic (pH < 5). Acidification correlated with yolk degradation in the various tissues examined, and yolk utilization was blocked when acidification was inhibited with bafilomycin, an inhibitor of vacuolar H+-ATPase. Bafilomycin also inhibited differentiation of cells isolated from stage 13-15 embryos. These data show that the yolk platelet pH is developmentally regulated and is involved in triggering yolk degradation. Also, yolk acidification and degradation appeared to be associated with cell differentiation and with the formation of the endosomal/lysosomal compartment, typical of adult cells, but absent in early embryos.

Acids↗

Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF).

PURPOSE: To study the feasibility of measuring total corneal thickness, as well as the thickness of the epithelium and Bowman's layer, using a novel in vivo confocal microscopy through-focusing (CMTF) methodology. METHODS: The central cornea was scanned from the epithelium to endothelium at an average focal plane speed of 32 microns/sec for rabbits, and 64 microns/sec for humans. Scans were initially video-recorded and later digitized. From digital images, CMTF intensity curves were generated by calculating the average pixel intensity in the central 180 x 180 pixel region (285 microns x 285 microns) of each image in the scan, and plotting as a function of z-depth. Peaks in this intensity profile were then empirically correlated to unique corneal layers using a program which interactively displayed images corresponding to the mouse cursor position along the intensity profile curve. Sublayer thickness values were then calculated from the z-axis positions of the relevant peaks in the intensity curve. Ten normal rabbits and seven human volunteers were evaluated in the study. Both CMTF and ultrasonic pachymetry (UP) measurements were performed on rabbit eyes to determine the agreement between CMTF and UP. RESULTS: Distinct epithelial, basal lamina, and endothelial peaks were identified for all 10 rabbit eyes. The mean central corneal thickness in the rabbit was 381.6 +/- 27.3 microns by CMTF and 384.4 +/- 28.7 microns by UP. The mean difference in central corneal thickness between CMTF and UP was -2.8 +/- 7.1 microns which was not statistically significant (p > 0.2 by paired t-test). Central epithelial thickness in the rabbit measured by CMTF was 47.7 +/- 2.2 microns. The average coefficients of variation for repeated scans were 2.5% and 0.7% for epithelial and corneal thickness, respectively. The standard errors for both epithelial and corneal thickness were less than 1.5 microns for all rabbits. The reproducibilities for epithelial and corneal thickness measurements were 2.2 microns and 2.6 microns, respectively, calculated as the square root of the within group variances of One-Way ANOVA. Intensity profiles for human corneas showed strong epithelial and endothelial peaks, as well as smaller peaks corresponding to the basal-epithelial nerve plexus and the denser anterior layer of stromal keratocyte nuclei. The mean central corneal thickness in the human was 532.1 +/- 18.8 microns; central epithelial thickness was 50.6 +/- 3.9 microns; central Bowman's layer thickness was 16.6 +/- 1.1 microns. The average coefficients of variation for repeated scans were 5.9%, 13.2%, and 1.6% for epithelial, Bowman's layer, and corneal thickness, respectively. The standard errors for all measurements were less than 2.4 microns. The reproducibilities for epithelial, Bowman's layer, and corneal thickness measurements were 3.2 microns, 2.3 microns, and 10.0 microns, respectively. CONCLUSIONS: CMTF is a novel, reproducible technique for obtaining epithelial and corneal thickness measurements during clinical in vivo confocal microscopy of the cornea. More importantly, this methodology provides the first objective, quantitative approach for measurement and analysis of depth and thickness of corneal sub-layers which may prove uniquely valuable in temporally assessing corneal function.

Adult↗

Scanning surface confocal microscopy for simultaneous topographical and fluorescence imaging: application to single virus-like particle entry into a cell.

We have developed a method for simultaneous recording of high-resolution topography and cell surface fluorescence in a single scan which we call scanning surface confocal microscopy. The resolution of the system allows imaging of individual fluorescent particles in the nanometer range on fixed or live cells. We used this technique to record the interaction of single virus-like particles with the cell surface and demonstrated that single particles sink into the membrane in invaginations reminiscent of caveolae or pinocytic vesicles. This method provides a technique for elucidating the interaction of individual viruses and other nanoparticles, such as gene therapy vectors, with target cells. Furthermore, this technique should find widespread application for studying the relationship of fluorescently tagged molecules with components of the cell plasma membrane.

Animals↗

Rearrangements of the fibrin network and spatial distribution of fibrinolytic components during plasma clot lysis. Study with confocal microscopy.

Binding of components of the fibrinolytic system to fibrin is important for the regulation of fibrinolysis. In this study, decomposition of the fibrin network and binding of plasminogen and plasminogen activators (PAs) to fibrin during lysis of a plasma clot were investigated with confocal microscopy using fluorescein-labeled preparations of fibrinogen, plasminogen, tissue-type PA (t-PA), and two-chain urokinase-type PA (tcu-PA). Lysis induced by PAs present throughout the plasma clot was accompanied by a gradual loss of fibrin content of fibers and by accumulation of plasminogen onto the fibers. Two sequential phases could be distinguished: a phase of prelysis, during which the fibrin network remained immobile, and a phase of final lysis, during which fibers moved with a tendency to shrink and eventually disappeared. The two phases occurred simultaneously but in different locations when lysis was induced by PAs present in the plasma surrounding the clot. The zone of final lysis was located within a 5-8 microns superficial layer, where fibers were mobile, a surface-associated fibrin agglomerates appeared. Plasminogen accumulated in these agglomerates up to 30-fold as compared with its concentration in the outer plasma. t-PA was also highly concentrated in the agglomerates, and tcu-PA bound to them slightly. The zone of prelysis, where plasminogen was moderately accumulated on the immobile fibers, was located deeper in the clot. This zone was much thinner in the case of t-PA-induced lysis than in the case of tcu-PA-induced lysis, reflecting the difference in penetration of the two PAs into the clot. We conclude that under conditions of diffusional transport of fibrinolytic enzymes from outside a plasma clot, extensive lysis is spatially restricted to a zone not exceeding 5-8 microns from the clot surface. In this zone the structure of the fibrin network undergoes significant changes, and strikingly high accumulation of fibrinolytic components takes place.

Blood Coagulation↗

Quantitative laser scanning confocal microscopy on single capillaries: permeability measurement.

OBJECTIVE: We tested the hypothesis that there is significant solute loss to the superfusate during microvessel solute permeability measurement in frog mesentery which leads to underestimation of permeability coefficient. This is the first application of laser-scanning confocal microscopy to measure microvessel permeability. METHODS: Microvessel permeability to sodium fluorescein (0.5 mg/ml, MW 376) was measured in the presence of bovine serum albumin (10 mg/ml) in Ringer's solution. Every 11-12s an optical section transverse to the vessel axis (x-z section) was collected. The images were corrected for fluorescence attenuation in the z direction and nonuniformity of light collection (shading) in the x direction by comparison to a fluorescent standard. Extravascular fluorescence, which increased linearly with time, and the step increase in fluorescence intensity of the vessel lumen were used to calculate an apparent permeability. Measurements were made first with the tissue superfused with Ringer and second after changing the superfusate to mineral oil in order to retain solute potentially lost to Ringer superfusate. RESULTS: The permeability to fluorescein measured with Ringer superfusate (5.0 +/- SD 2.6 x 10(-5) cm/s; n = 3) was not different from that measured with mineral oil covering the upper mesothelial surface (4.5 +/- 1.9). CONCLUSIONS: Therefore, the loss of sodium fluorescein through the upper mesothelium does not significantly alter permeability under these conditions. These techniques enable detailed analysis of solute concentration gradients surrounding microvessels.

Animals↗

Z-polarized confocal microscopy.

In light microscopy the transverse nature of the electromagnetic field precludes a strongly focused longitudinal field component, thus confining polarization spectroscopy and imaging to two dimensions (x,y). Here we describe a simple confocal microscopy arrangement that optimizes for signal from molecules with transition dipoles oriented parallel to the optic axis. In the proposed arrangement, we not only generate a predominant longitudinally (z) polarized focal field, but also engineer the detection scheme in such a way that in a bulk of randomly oriented molecules, the microscope's effective point-spread function is dominated by the contribution of those molecules that are oriented along the optic axis. Our arrangement not only implicitly allows for the determination of the orientation of transition dipoles of single molecules in three dimensions, but also highlights the contribution of z-oriented molecules in three-dimensional imaging.

Microscopy, Confocal↗