Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Computer Peripherals”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Optimal digital filtering for tremor suppression.

Remote manually operated tasks such as those found in teleoperation, virtual reality, or joystick-based computer access, require the generation of an intermediate electrical signal which is transmitted to the controlled subsystem (robot arm, virtual environment, or a cursor in a computer screen). When human movements are distorted, for instance, by tremor, performance can be improved by digitally filtering the intermediate signal before it reaches the controlled device. This paper introduces a novel tremor filtering framework in which digital equalizers are optimally designed through pursuit tracking task experiments. Due to inherent properties of the man-machine system, the design of tremor suppression equalizers presents two serious problems: 1) performance criteria leading to optimizations that minimize mean-squared error are not efficient for tremor elimination and 2) movement signals show ill-conditioned autocorrelation matrices, which often result in useless or unstable solutions. To address these problems, a new performance indicator in the context of tremor is introduced, and the optimal equalizer according to this new criterion is developed. Ill-conditioning of the autocorrelation matrix is overcome using a novel method which we call pulled-optimization. Experiments performed with artificially induced vibrations and a subject with Parkinson's disease show significant improvement in performance. Additional results, along with MATLAB source code of the algorithms, and a customizable demo for PC joysticks, are available on the Internet at http:¿tremor-suppression.com.

Algorithms↗

Application of tilt sensors in human-computer mouse interface for people with disabilities.

This study describes the motivation and the design considerations of an economical head-operated computer mouse. In addition, it focuses on the invention of a head-operated computer mouse that employs two tilt sensors placed in the headset to determine head position and to function as simple head-operated computer mouse. One tilt sensor detects the lateral head-motion to drive the left/right displacement of the mouse. The other one detects the head's vertical motion to move up and down with respect to the displacement of the mouse. A touch switch device was designed to contact gently with operator's cheek. Operator may puff his cheek to trigger the device to perform single click, double clicks, and drag commands. This system was invented to assist people with disabilities to live an independent professional life.

Communication Devices for People with Disabilities↗

DASHER--an efficient writing system for brain-computer interfaces?

DASHER is a human-computer interface for entering text using continuous or discrete gestures. Through its use of an internal language model, DASHER efficiently converts bits received from the user into text, and has been shown to be a competitive alternative to existing text-entry methods in situations where an ordinary keyboard cannot be used. We propose that DASHER would be well-matched to the low bit-rate, noisy output obtained from brain-computer interfaces (BCIs), and discuss the issues surrounding the use of DASHER with BCI systems.

Brain↗

Electronic imaging workstations: ergonomic issues and the user interface.

The electronic imaging workstation serves as the interface between an electronic system and a user. Although the performance aspects of electronic displays are crucial considerations in workstation design, experience suggests that human factors in mechanical operation, software accessibility, and workstation environment are also important. Generally, workstations should have monitors arranged horizontally, and the work environment should be designed to minimize glare from lighting fixtures and to accommodate requirements for low luminance. Devices that control the workstation (eg, key pads, track balls) should be designed so that the user can operate primary and auxiliary controls with efficiency of hand and eye movements. Although many innovations in software (eg, graphical user interfaces) have allowed current workstations to be operated by users who have no knowledge of computer operations, further improvements in interactive software are necessary if such systems are to be accepted by radiologists.

Computer Peripherals↗

A visual telemedicine system: the integration of ordinary TV and HDTV still image transmission.

This paper describes a project to develop and test a new telemedicine system using image transmission. The system was implemented at Aomori prefecture, the northernmost prefecture of Japan, to provide medical consultation to remote hospitals from a medical center located in Aomori city, capital of the prefecture. The characteristics of the system are the combination of an HDTV still image transmission system and an ordinary tele-conference system using 65 kilobit telephone line i.e., an ordinary telephone line available in almost any part of Japan. We also developed a disk storage system that stores transmitted images automatically without human intervention. The system was assessed in real clinical settings and has proved to be effective in various areas of medical consultation, including radiology, pathology, dermatology, etc. We hope that this system becomes a standard telemedicine system in the future.

Computer Peripherals↗

A computer program for sequencing and presenting complex sounds for auditory neuroimaging studies.

This paper describes a computer program, named ASAP (audio sequencing and presentation), that runs on IBM PC compatible hardware with a Microsoft Windows operating system and has been specially designed for facilitating auditory neuroimaging studies. The program's main characteristics are: (1) the ability to generate sequences of complex sounds; (2) an easy-to-use, graphical user interface; (3) full compatibility with Microsoft Windows 95 or later and Windows NT version 4.0 or later software; (4) precise timing of selected sound sequences; (5) the capability of triggering other devices; (6) the capability of being triggered to deliver stimuli; (7) support for both monotic and dichotic sound sequences; and (8) rudimentary support for the simultaneous presentation of pictures/text and sound.

Acoustic Stimulation↗

Nine ways to use handheld computers.

Handheld computers can be used to make calculations, share articles with colleagues, store contact information, and even save lives. Translation software can facilitate communication with non-English-speaking patients. You can find out the cost of medications with drug reference software. Make the ED schedules accessible, so that staff can volunteer to fill in gaps.

Computer Peripherals↗

Image-guided neurosurgery comparing a pointer device system with a navigating microscope: a retrospective analysis of 208 cases.

A retrospective analysis of neuronavigation procedures performed at the Vienna Neurosurgical Clinic was undertaken to elucidate the advantages of 2 technically different navigation systems in clinical use. In a 30-month period, 208 frameless stereotactic procedures were performed using a stereotactic microscope (MKM System, Zeiss; 92 procedures in 87 patients; 47 female, 40 male; mean age, 46 yrs) and a light emitting diode (LED) based pointer navigation device (Easy Guide Neuro (EGN), Philips; 116 procedures in 114 patients; 63 female, 51 male; mean age 46.4 yrs). The navigating microscope was exclusively used for cranial navigation, the pointer device system in 107 cases for cranial and in 9 cases for spinal navigation. Procedures were CCT-guided in 109 cases, MRI-guided in 95, and both CT/MRI guided in 4 cases. Skin fiducials were used in all these procedures. The MKM system provided coordinate-based navigation, similar to frame systems. This allowed surgical planning and performance using stereotactic coordinates for target calculation. Additionally, tumor volumes were defined by contours and projected into the ocular of the microscope, allowing guidance during targeting and resection of lesions. Both of these features proved beneficial in tumor surgery (60.8% MKM cases), cavernoma surgery (21.8% MKM cases), and epilepsy surgery (14.1% MKM cases). In contrast to the microscope, the pointer navigation system could be employed for intuitive correlation of image points with points of interest in the operating field by using a LED-equipped pointer device. This permitted image guidance during a wide spectrum of neurosurgical procedures, in tumor surgery (68.1% EGN cases), cavernoma surgery (5.1% EGN cases), epilepsy surgery (14.1% EGN cases), vascular surgery (3.4% EGN cases), spinal surgery (7.8% EGN cases), and guidance for burr holes and drainages (6.9% EGN cases), without calculating stereotactic coordinates. This analysis showed clear differences in the application of the two systems and may facilitate the decision as to which system best meets the individual demands of a neurosurgical department.

Adult↗

Changes in upper extremity biomechanics across different mouse positions in a computer workstation.

In order to determine differences in biomechanical risk factors across different mouse positions within computer workstations a repeated measures laboratory study was completed with 30 adults (15 females 15 males). The subjects performed mouse-intensive tasks during two experiments. One experiment examined three mouse positions: a standard mouse (SM) position with the mouse directly to the right of the keyboard; a central mouse (CM) position with the mouse between the keyboard and the body, positioned in the body's mid-sagittal plane; a high mouse (HM) position, which simulated using a keyboard drawer with the mouse on the primary work surface. The second experiment compared two mouse positions: the SM position and a more central position using a keyboard without a number keypad (NM). Electrogoniometers and inclinometers measured wrist and upper arm postures and surface electromyography measured muscle activity of four forearm muscles and three shoulder muscles. The CM mouse position was found to produce the most neutral upper extremity posture across all measures. The HM position produced the least neutral posture and resulted in the highest level of muscle activity. Compared to the SM position, the NM position reduced wrist extension slightly and promoted a more neutral shoulder posture. Little difference in muscle activity was observed between the SM and NM positions. In conclusion, of these alternative mouse positions, the HM position was the least desirable, whereas the CM position reduced overall awkward postures associated with mouse-intensive computer tasks.

Adult↗

Basic study on the rectangular numeric keys for touch screen.

The present study was conducted to examine the optimum inter-key spacing of numeric rectangular keys for touch screens. Six male students (22-25 years old) and three female students (21-24 years old) participated in the experiment. Each subject performed the data entry task using rectangular keys of touch devices. These keys were arranged in both horizontal and vertical layouts. The sizes of the rectangular keys in both layouts were 12 x 21 mm and 15 x 39 mm, and each of the inter-key spacing of each key was 0, 3, 6, 12 and 21 mm. The response time with inter-key spacing of 3 mm was significantly faster than with the inter-key spacing of 0, 12 and 21 mm (p < 0.05). Keys of vertical position produced faster response time than that of horizontal position. The subjective ratings showed that the inter-key spacing of 6 mm was significantly better than the inter-key spacing of 0, 3, 12 and 21 mm (p < 0.05).

Adult↗

Pen-based computing: applications in clinical medicine.

Handheld, pen-based computing is an affordable, empowering technology that has application in small practice settings as well as in hospital-wide environments. Although hardware standards are evolving, there is now a stable base of applications, wired and wireless connectivity, and other features that make pen-based computing an attractive alternative to paper and pen patient data acquisition. When combined with centralized data synchronization, pen-based computers can also serve as an affordable medium for the dissemination of clinical guidelines, standard formulary, and other patient-related data. Wireless, and to a lesser extent, wired pen-PDAs hold the potential to make web-based electronic medical records accessible from anywhere at any time.

Computer Peripherals↗

Experimental study of fat embolism syndrome.

To find the diagnostic methods for subclinical stage fat embolism syndrome (FES), we established an experimental animal model, using fat intravenous injection. The fat was obtained from the long bone marrow cavity of homologous dogs. Fourteen healthy mongrel dogs received 0.7 ml/kg fluid marrow fat injection and all of them developed FES within 48 hours. The blood samples collected from the pulmonary vessels by floating catheter and peripheral vein at different time intervals were subjected to blood gas analysis and were frozen sectioned rapidly. The sections were stained with oil red 'O'. Positive result was seen 2 hours after fat injection in both pulmonary and peripheral blood. Computer image analysis showed that the number and diameter of fat droplets in pulmonary vascular blood were obviously higher and larger than those in peripheral vein blood. These findings were correlated well with blood gas changes and clinical features. The demonstration of fat droplets from pulmonary or peripheral blood by oil red 'O' staining combined with blood gas changes (PaO2 < 7.99 kPa, P(A-a)O2 > 6.09 kPa) may be rapid and specific for early diagnosis of FES. In the treatment of FES, dexamethason can stabilize the cellular membranes and inhibit the neutrophil response to fatty acid and the release of phospholipase A2, arachidonic acid and platelet aggregation.

Animals↗

A full-size MRI-compatible keyboard response system.

Two commercially available plastic keyboards were contrasted in the degree to which they interfered with echo planar imaging. One keyboard (GrandTec USA's "Virtually Indestructible Keyboard") caused significantly less temporally variant and invariant signal loss and was integrated into a MRI interface system for recording participants' manual motor responses. The response recording system is safe, accurately records reaction time behavioral data, and does not interfere with functional data collection. Implementing this MRI-compatible keyboard allows the collection of motor responses from complex manual behaviors (i.e., typing) and thus represents a valuable tool for functional MRI (fMRI) studies.

Adult↗

The camera mouse: visual tracking of body features to provide computer access for people with severe disabilities.

The "Camera Mouse" system has been developed to provide computer access for people with severe disabilities. The system tracks the computer user's movements with a video camera and translates them into the movements of the mouse pointer on the screen. Body features such as the tip of the user's nose or finger can be tracked. The visual tracking algorithm is based on cropping an online template of the tracked feature from the current image frame and testing where this template correlates in the subsequent frame. The location of the highest correlation is interpreted as the new location of the feature in the subsequent frame. Various body features are examined for tracking robustness and user convenience. A group of 20 people without disabilities tested the Camera Mouse and quickly learned how to use it to spell out messages or play games. Twelve people with severe cerebral palsy or traumatic brain injury have tried the system, nine of whom have shown success. They interacted with their environment by spelling out messages and exploring the Internet.

Activities of Daily Living↗