Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CADAVER”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Cadaver radiography in the teaching of gross anatomy.

The authors describe a new teaching method for first-year medical students, involving preparation and use of cadaver radiographs in the gross anatomy laboratory. A standard series of radiographs of each cadaver was obtained prior to dissection and provided to each group of students. This technique offers a unique opportunity for radiographic/anatomical/pathological correlation, facilitates an understanding of complex anatomical relationships, and illustrates the application of anatomical knowledge to clinical practice. It can also generate intense student enthusiasm and improve student-faculty communication and teaching relationships.

Anatomy↗

Percutaneous lumbar diskectomy using a new aspiration probe: porcine and cadaver model.

A method of percutaneous aspiration of the nucleus pulposus of lumbar disks is described as performed in four pigs and three cadavers. Through a lateral oblique percutaneous approach, 80-100% of the nucleus pulposus was removed in each of the pigs; approximately 30% of the cadaver disk was removed. A unique aspiration probe and the introducing set as well as the technique are described. The implications for clinical use in patients are discussed. We believe this technique may be an alternative to both surgical diskectomies and chymopapain injection in the treatment of herniated disk disease of the lumbar spine.

Adult↗

Results of cadaver kidney transplantation with right renal vein extension.

INTRODUCTION: Several methods to lengthen the renal vein of the allografts have been proposed in order to secure the surgeon's field of vision and to allow appropriate positioning of the graft. However, its safety and complications have not been clarified. Furthermore, its long- and short-term results have not been investigated. Therefore, we studied the results of this operative procedure to confirm the safety of the technique. METHODS: The right renal vein extension was utilized when the donated right kidney from a cadaver donor had sufficient length of the inferior vena cava wall. The results of 10 patients who received kidney transplantation with renal vein extension were examined. RESULTS: None of the patients had vascular complications. The transplanted kidney functioned in all patients; 3- and 5-year graft survival was 100 and 75.0%, respectively. CONCLUSIONS: The results confirmed that this technique was safe and without complications and did not affect the long- and short- term results of patients who received cadaver kidneys. Therefore, we conclude that it is appropriate to adapt this technique when the physician judges the long renal vein suitable for the procedure.

Adult↗

Arteriographic study of the arterial supply of the foot in one hundred cadaver feet.

The arterial supply of 100 human cadaver feet (87 cadavers) was investigated by stereoscopic arteriography and was compared phylogenetically to that of the macaque foot. The deep plantar arch was always well developed and complete, whereas the superficial plantar arch was usually slender and incomplete. The first proximal perforating artery arising from the dorsalis pedis artery formed the main component of the deep plantar arch in 82% of the feet. The second proximal perforating artery arising from the dorsal rete contributed to the deep plantar arch in 43% of the feet, and formed most of the arch in one foot. The dorsal rete was classified into four groups of variants based on the arterial source of the second dorsal metatarsal artery. These were the arcuate artery (25%), distal lateral tarsal artery (12%), proximal lateral tarsal artery (6%), and nondorsal rete (57%) variants. In the first intermetatarsal space, the dorsal and plantar metatarsal arteries shared a common trunk in 54% of the feet, but this did not occur in the other intermetatarsal spaces. The second dorsal metatarsal artery arose from the dorsal rete in 43% of the feet, and this artery was quite large, sometimes being the largest of all the dorsal and plantar metatarsal arteries. Variations of the arterial supply found in humans sometimes resembled the typical pattern found in the macaque.

Adult↗

A preclinical cadaver fitting study of implantable biventricular assist device-- AnyHeart.

A multifunctional, Korean-made artificial heart (AnyHeart) was developed, and prior to its clinical application, a cadaver-fitting study was performed. The study proposed to determine the optimal cannulation approach, implantation technique and route of the cannula to minimize the organ compression of AnyHeart. The anatomical feasibility and a variety of surgical techniques were evaluated using ten preserved, human cadavers. Implanting AnyHeart with ease is possible using various approaches, including a median sternotomy, and a right or left lateral thoracotomy. The lateral thoracotomy approach is shown to be safe and reproducible, especially in patients who have already undergone an operation that used a median sternotomy. The results of this study will guide improvements in the designs of cannulae and AnyHeart for future clinical applications.

Adolescent↗

Suture-endobutton fixation of ankle tibio-fibular diastasis: a cadaver study.

Suture-Endobutton fixation is proposed as a minimally invasive, flexible fixation of ankle tibio-fibular diastasis, which would not require routine removal. This study tested the Suture-Endobutton construct in a cadaver syndesmosis injury model and compared this against A.O. syndesmosis screw fixation. Sixteen embalmed cadaver legs were used. Phase one consisted of placing the leg in a jig, generating an external rotation torque and measuring diastasis with increasing intraosseous membrane division. Phase two then compared the Suture-Endobutton construct vs. single four-cortex 4.5 mm A.O. screw fixation. Diastasis increased significantly with increasing intraosseous membrane division (p<0.001). No significant differences were seen in the mean rate of failure between the Suture-Endobutton and A.O. screw fixation. However, the Suture-Endobutton did give a significantly more consistent performance; the distribution of standard deviations for A.O. screw fixation was 0.64 mm higher than that for the Endobutton (95% C.I. 0.46 to 0.84). These results show that Suture-Endobutton fixation at least equals the performance of screw fixation and encourages clinical trials in ankle injuries with a syndesmosis diastasis.

Ankle Injuries↗

Endoscopic gastrocnemius recession: evaluation in a cadaver model.

The purpose of this study was to describe a new method of gastrocnemius recession using an endoscopic approach and to determine the accuracy of incision placement during gastrocnemius recession. Fifteen fresh-frozen cadaveric limbs underwent an endoscopic gastrocnemius recession utilizing a two-portal technique. All limbs were anatomically dissected after the procedure and each was examined for injury to the sural nerve. The ability to visualize the sural nerve intraoperatively, improvement in ankle dorsiflexion, time requirement for the procedure, incision size, and appropriateness of placement to facilitate recession were recorded for each specimen. An average of 83% of the gastrocnemius aponeurosis was transected in all 15 cadavers. After modifications of the technique, the final eight cadavers were noted to have had the entire (100%) gastrocnemius aponeurosis transected. Sural nerve injury occurred in one specimen (7%) in which the aponeurosis and the sural nerve were not well visualized. The sural nerve was definitively visualized during the procedure in 5 of 15 specimens (33%). No Achilles tendon injury was noted in any specimen. There was a mean improvement in ankle dorsiflexion of 20 degrees (range, 10 degrees-30 degrees) during full knee extension. The average length of time to perform the procedure was 20 minutes (range, 10-35 minutes). The average medial and lateral incision lengths used in the two-portal technique were 18 mm (range, 14-22 mm) and 17 mm (range, 12-19 mm), respectively, and the average distance from the midpoint of the medial incision to the level of the gastrocnemius-soleus junction was 26 mm (range, 5-60 mm). These results indicate that a complete gastrocnemius aponeurosis transection may be obtained utilizing a modified endoscopic gastrocnemius recession, but visualization of the sural nerve is poor with possible risk of iatrogenic nerve injury.

Cadaver↗

Plantar pressure and load in cadaver feet after a Weil or chevron osteotomy.

BACKGROUND: Since metatarsal osteotomy was first used to treat metatarsalgia in the early twentieth century, many techniques have been described to accomplish the basic aim of reduction of load transmission through the operated metatarsal and reduction of localized high pressure on the plantar surface of the metatarsal. Our study examined two popular distal metatarsal neck osteotomies used for the relief of central metatarsalgia and the biomechanical changes that result from their use in a cadaver forefoot model. METHODS: After applying 445 N (100 lbs) of axially directed force, we measured plantar pressure using the TekScan HR Mat (TekScan, Inc., South Boston, MA) in twelve paired, thawed, fresh-frozen intact cadaver legs, then after either a Weil or chevron osteotomy of the second metatarsal and finally after the addition of the same osteotomy of the third metatarsal. RESULTS: Load in the forefoot was not significantly affected by the Weil osteotomy. A significant increase in load was produced in the first metatarsal region, and significant decreases in load were produced beneath the operated metatarsal heads after the chevron osteotomy. Average pressure in the contact area of the forefoot showed similar trends; however, load and pressure changes occurred independently, owing to the changes in contact area produced by the osteotomies. No significant changes were observed in the nonoperated metatarsal regions. CONCLUSIONS: In this model, the chevron osteotomy more effectively reduced load and plantar pressure in the operated metatarsal regions; however, increases in load and pressure were observed in the first metatarsal region. The increase in pressure without a change in load in region 3 (third metatarsal) after a Weil osteotomy of the third metatarsal was attributed to the creation of a plantar prominence. This study did not show a reduction in load transmission as a result of the Weil osteotomy, which contradicts the proposed mechanism of clinical benefit. An intact first ray likely prevents transfer of load or pressure to adjacent lesser metatarsals with chevron osteotomy.

Biomechanical Phenomena↗

Calcaneal lengthening: investigation of deformity correction in a cadaver flatfoot model.

BACKGROUND: Evans showed that lengthening the lateral column by inserting structural bone graft into the anterior calcaneus could correct abduction and valgus deformity in flatfoot. To better understand the mechanism of correction and the three-dimensional effect of this procedure a cadaver study was done. METHODS: Three cadaver flatfoot models were used. Computed tomographic (CT) scans were made of each specimen before and after lengthening. Data from these scans were used to determine the center of volume of the talus, navicular, cuboid, and calcaneus. The angular and translational motions for each bone were determined. RESULTS: On average, relative to the talus, the navicular moved 18.6 degrees of rotation in adduction, 2.6 degrees of rotation in pronation, and 3.4 degrees in plantarflexion. The average translation was 5.6 mm medial, 0.4 mm posterior, and 1.8 mm plantar. The cuboid moved an average of 24.2 degrees of rotation in adduction and lengthening, 13.9 degrees in pronation, and 1.9 degrees in plantarflexion. The average translation was 9.4 mm medial, 2.6 mm distal, and 1.5 mm plantar. The calcaneus moved an average of 4.4 degrees of rotation in adduction, 0.1 degrees of rotation in eversion, and 1.3 degrees of plantarflexion. The average translation was 3 mm medial and 0.7 mm posterior with no plantar translation. CONCLUSIONS: The mechanism of Evans calcaneal lengthening involves adduction and plantarflexion of the midfoot relative to the hindfoot. The cuboid and navicular appear to move as a unit. The shape of the talar head, axis of the subtalar joint, degree of initial deformity, competence of plantar soft tissues, such as the long plantar ligament, and adequate length of the Achilles tendon are important. Knowing what qualitative three-dimensional changes take place allows a better understanding of the mechanics of the procedure and its possible applications.

Cadaver↗

First metatarsophalangeal joint motion after hallux valgus correction: a cadaver study.

BACKGROUND: Surgical correction of hallux valgus deformities often results in decreased first metatarsophalangeal joint (MTPJ) range of motion. Loss of motion has been shown to affect patient satisfaction. The purpose of this study was to evaluate the immediate change in MTPJ range of motion that occurs after a distal soft-tissue reconstruction (DSTR) and proximal metatarsal osteotomy (PMO). METHODS: DSTR and PMO were done on 16 below-knee cadaver specimens with clinically apparent hallux valgus deformities. Two examiners assessed preoperative and postoperative dorsiflexion (DF), plantarflexion (PF), and the total range of motion of the first MTPJ. The hallux valgus angle (HVA) and 1-2 intermetatarsal angle (1-2 IMA) were measured on simulated weightbearing radiographs before and after operative correction. Changes in motion were analyzed and correlated with the angular measurements. RESULTS: The mean total range of motion preoperatively was 85.4 degrees (DF 70.5 degrees, PF 14.9 degrees) and significantly decreased (p < 0.005) 23.2 degrees to a postoperative value of 62.2 degrees (DF 47.9 degrees, PF 14.3 degrees). There was a significant (p < 0.005) decrease in DF (22.6 degrees) with the operative correction, but the loss of PF (0.6 degrees) was not significant (p = 0.7). There was no correlation between the magnitude of correction (HVA, 1-2 IMA) and the change in PF, DF, or total motion. CONCLUSIONS: Correction of a hallux valgus deformity with a DSTR and PMO is associated with an immediate loss of range of motion that primarily affects the DF arc of the first MTPJ. The selective loss of DF may be related to a nonisometric capsular repair or tight intrinsic musculature, although there was no correlation with the magnitude of angular correction. The immediate decrease in motion observed in this cadaver study underscores the importance of early postoperative joint mobilization to prevent long-term stiffness after bunion surgery.

Aged↗

Effect of first metatarsal shortening and dorsiflexion osteotomies on forefoot plantar pressure in a cadaver model.

BACKGROUND: Metatarsalgia of the second ray is a common problem associated with disorders of the first metatarsal. It also occurs after the operative treatment of those disorders. Plantar pressure changes from alteration of the static and dynamic structure of the forefoot may be associated with this condition. This study evaluated changes in plantar forefoot pressure especially under the second metatarsal head after three operative procedures on the first ray. METHODS: Each of 12 cadaver foot specimens was cyclically loaded on the servohydraulic MTS Mini Bionix test frame (MTS Systems Corp., Eden Prairie, MN) with traction on the Achilles tendon. Plantar forefoot pressure was measured by the F-scan system (Tekscan, Inc., S. Boston, MA) with the foot intact, after a first metatarsal base dorsal closing-wedge osteotomy with 5-mm base length to simulate dorsal malunion, and after 5-mm and 10-mm metatarsal shortening procedures. Paired Student t-test analysis was used to compare data for the intact foot with data after each intervention. One form of Bonferroni's correction was done to establish a new alpha level to tighten the analysis and to compensate for multiple paired Student t-tests. The significance level was calculated to be 0.016 based on an original alpha level of 0.05. RESULTS: As compared with the intact foot, all three procedures on the first metatarsal resulted in significant decreases in plantar pressure under the first metatarsal head (p < 0.016). Plantar pressure under the second metatarsal head increased significantly as compared with the intact foot (p < 0.016) after all three procedures. Pressures under the third-fourth metatarsal heads increased significantly compared with the intact foot after the 5-mm and 10-mm shortenings (p < 0.016). Plantar pressure under the fifth metatarsal did not change significantly after any of the three procedures. CONCLUSIONS: Dorsiflexion osteotomy and shortening of the first metatarsal are associated with significant forefoot plantar pressure changes in a cadaver model.

Cadaver↗

The effect of achilles tendon lengthening on ankle dorsiflexion: a cadaver study.

BACKGROUND: Tendon lengthening is an important cause of morbidity after Achilles tendon rupture. However, direct measurement of the tendon length is difficult. Ankle dorsiflexion has, therefore, been used as a surrogate measure on the assumption that it is the Achilles tendon that limits this movement. The aim of this investigation was to assess the relationship between Achilles tendon length and ankle dorsiflexion. The primary question was whether or not the Achilles tendon is the structure that limits ankle dorsiflexion. The secondary purpose was to quantify the relationship between Achilles tendon lengthening and dorsiflexion at the ankle joint. METHODS: Five cadaver specimens were dissected to expose the tendons and capsular tissue of the leg and hindfoot. Fixed bony reference points were used as markers for the measurements. In the first specimen, the Achilles tendon was intact and the other structures that may limit ankle dorsiflexion were sequentially divided. In the other specimens the Achilles tendon was lengthened by 1 cm intervals and the effect upon ankle dorsiflexion movement was recorded. RESULTS: Division of the other tendons and the capsular tissue around the ankle joint did not affect the range of ankle dorsiflexion. When the Achilles was divided the foot could be dorsiflexed until the talar neck impinged upon the anterior aspect of the distal tibia. There was a mean increase of 12 degrees of dorsiflexion for each centimeter increase in tendon length. CONCLUSION: The Achilles tendon is the anatomical structure that limits ankle dorsiflexion, even when the tendon is lengthened. There was a linear relationship between the length of the Achilles tendon and the range of ankle dorsiflexion in this cadaver model. Ankle dorsiflexion would appear to be a clinically useful indicator of tendon length.

Achilles Tendon↗

The effect of fixation and location on the stability of the markers in navigated total hip arthroplasty: a cadaver study.

In navigated total hip arthroplasty, the pelvis and the femur are tracked by means of rigid bodies fixed directly to the bones. Exact tracking throughout the procedure requires that the connection between the marker and bone remains stable in terms of translation and rotation. We carried out a cadaver study to compare the intra-operative stability of markers consisting of an anchoring screw with a rotational stabiliser and of pairs of pins and wires of different diameters connected with clamps. These devices were tested at different locations in the femur. Three human cadavers were placed supine on an operating table, with a reference marker positioned in the area of the greater trochanter. K-wires (3.2 mm), Steinman pins (3 and 4 mm), Apex pins (3 and 4 mm), and a standard screw were used as fixation devices. They were positioned medially in the proximal third of the femur, ventrally in the middle third and laterally in the distal portion. In six different positions of the leg, the spatial positions were recorded with a navigation system. Compared with the standard single screw, with the exception of the 3 mm Apex pins, the two-pin systems were associated with less movement of the marker and could be inserted less invasively. With the knee flexed to 90 degrees and the dislocated hip rotated externally until the lower leg was parallel to the table (figure-four position), all the anchoring devices showed substantial deflection of 1.5 degrees to 2.5 degrees . The most secure area for anchoring markers was the lateral aspect of the femur.

Arthroplasty, Replacement, Hip↗

Uncompromised quality of the cement mantle in Exeter femoral components implanted through a minimally-invasive direct anterior approach. A prospective, randomised cadaver study.

A complete cement mantle is important for the longevity of a total hip replacement. In the minimally-invasive direct anterior approach used at the Innsbruck University hospital, the femoral component has to be inserted into the femoral canal by an angulated movement. In a cadaver study, the quality and the extent of the cement mantle surrounding 13 Exeter femoral components implanted straight through a standard anterolateral transgluteal approach were compared with those of 13 similar femoral components implanted in an angulated fashion through a direct anterior approach. A third-generation cementing technique was used. The inner and outer contours of the cement mantles was traced from CT scans and the thickness and cross-sectional area determined. In no case was the cement mantle incomplete. The total mean thickness of the cement mantle was 3.62 mm (95% confidence interval 3.59 to 3.65). The mean thickness in the group using the minimally-invasive approach was 0.16 mm less than that in the anterolateral group. The distribution of the thickness was similar in the two groups. The mean thickness was less on the anteromedial and anterolateral aspect than on the posterior aspect of the femur. There is no evidence that the angulated introduction of Exeter femoral components in the direct anterior approach in cadavers compromises the quality, extent or thickness of the cement mantle.

Arthroplasty, Replacement, Hip↗

Procuring organs from a non-heart-beating cadaver: a case report.

Organ transplantation is an accepted therapy for major organ failure, but it depends on the availability of viable organs. Most organs transplanted in the U.S. come from either "brain-dead" or living related donors. Recently organ procurement from patients pronounced dead using cardiopulmonary criteria, so-called "non-heart-beating cadaver donors" (NHBCDs), has been reconsidered. In May 1992, the University of Pittsburgh Medical Center (UPMC) enacted a new, complicated policy for procuring organs from NHBCDs after the elective removal of life support. Seventeen months later only one patient has become a NHBCD. This article describes her case and the results of interviews with the health care team and the patient's family. The case and interviews are discussed in relation to several of the ethical concerns previously raised about the policy, including potential conflicts of interest, the definition of cardiopulmonary death, and a possible net decrease in organ donation. The conclusion is reached that organ procurement from non-heart-beating cadavers is feasible and may be desirable both for the patient's family and the health care providers.

Academic Medical Centers↗

Procuring organs from a non-heart-beating cadaver: commentary on a case report.

Procurement of organs from non-heart-beating cadaver donors raises concerns. Standards for optimal patient care during withdrawal of life-sustaining therapy are evolving and continue to be debated and studied. Consensus on specific procedures and methods has not been attained, however, and protocols for the procurement of organs from patients following the withdrawal of life-sustaining therapies may compromise the evolving standards and harm the patient and the attendant family. In addition, there is little evidence to suggest that such protocols will significantly increase the number of organs procured. "Non-heart-beating cadaver" protocols that do not give comprehensive attention to optimal patient/family care at the time of withdrawal of life-sustaining therapy ought not to be endorsed.

Cadaver↗

Fertility of mouse spermatozoa retrieved from cadavers and maintained at 4 degrees C.

After male animals die, the spermatozoa within the testis and epididymis eventually disintegrate. In this study, the motility, viability and fertility of mouse spermatozoa were examined after retrieval from the epididymis at various days after death. Cadavers were maintained in a refrigerator at 4 degrees C. About 30% of the spermatozoa collected 10 days after death were viable, but they had limited ability to fertilize oocytes in vitro. However, when the spermatozoa were injected into oocytes, the fertilization rate was over 80%. Normal live fetuses were even obtained using immotile spermatozoa retrieved 20 days after death. Therefore, when valuable male animals die unexpectedly and sperm cryopreservation is not possible immediately, temporal storage of cadavers (or epididymis and vas deferens) at 4 degrees C in a regular refrigerator followed by intracytoplasmic sperm injection may help to preserve the genome of individuals. This procedure could be particularly important in endangered species.

Animals↗

Cadaver-donor renal transplantation of children in Israel (1990-2001): racial disparities in health care delivery?

OBJECTIVE: To evaluate the allocation and outcome of cadaver-donor renal transplantation (CDRTx) among Jewish and Arab children in Israel. METHODS: Data on CDRTxs in patients who had end-stage renal failure (ESRF), were younger than 18 years, and were on dialysis treatment were obtained for the 11-year period of January 1990 to December 2000 from the Israeli Dialysis and Transplant Registry, supplemented by 10 years of follow-up (January 1991-December 2000) from our own center. RESULTS: The Israeli Dialysis and Transplant Registry data show that 64 of 130 available cadaver-donor kidneys (CDKs) were allocated to Jewish patients (49.2%) and 66 of 130 were allocated to Arab children (50.8%): Moslem, Druze, or Christian. The Jew/Arab patient ratio for a waiting time of <1 year was 0.97 and for 1 to 2 years was 1.45, whereas that ratio was 0.6 for 2 to 4 years and 2.0 for >4 years. The mean renal transplant score (RTx score), reflecting the urgency of the need for RTx of an ESRF patient, was identical for Jew and Arab: 4.93 and 4.96. Our own center data refer to 69 dialysis (47 Arabs and 22 Jews) and 4 predialysis patients younger than 18 years who underwent 78 RTxs. Eighteen Arab and 14 Jewish children from our center received 20 and 15 CDRTxs in Israel, with a mean waiting time of 29.6 and 25.4 months for Jew and Arab, respectively (ratio: 1.16). In our center, the outcome (after 7 years) of graft survival and function was not different between Jewish and Arab RTx recipients. CONCLUSIONS: Allocation of CDRTxs between young Jewish and Arab ESRF patients on dialysis did not differ and was associated with comparable waiting times, identical RTx scores, and similar long-term outcome. This is a remarkable finding, certainly in the face of the unequal race allocation of RTxs in the United States as well as the long unstable local (Middle East) political situation.

Adolescent↗