Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “BLOOD”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Influence of aortic blood flow velocity on changes of middle cerebral artery blood flow velocity during isoflurane and sevoflurane anaesthesia.

BACKGROUND AND OBJECTIVE: We studied the influence of systemic (aortic) blood flow velocity on changes of cerebral blood flow velocity under isoflurane or sevoflurane anaesthesia. METHODS: Forty patients (age: isoflurane 24-62 years; sevoflurane 24-61 years; ASA I-III) requiring general anaesthesia undergoing routine spinal surgery were randomly assigned to either group. Cerebral blood flow velocity was measured in the middle cerebral artery by transcranial Doppler sonography (depth: 50-60 mm). Systemic blood flow velocity was determined by transthoracic Doppler sonography at the aortic valve. Heart rate, arterial pressure, arterial oxygen saturation and body temperature were monitored. After standardized anaesthesia induction (propofol, remifentanil, vecuronium) sevoflurane or isoflurane were used as single agent anaesthetics. Cerebral blood flow velocity and systemic blood flow velocity were measured in the awake patient (baseline) and repeated 5 min after reaching a steady state of inspiratory and end-expiratory concentrations of 0.75, 1.00, and 1.25 mean alveolar concentrations of either anaesthetic. To calculate the influence of systemic blood flow velocity on cerebral blood flow velocity, we defined the cerebral-systemic blood flow velocity index (CSvI). CSvI of 100% indicates a 1:1 relationship of changes of cerebral blood flow velocity and systemic blood flow velocity. RESULTS: Isoflurane and sevoflurane reduced both cerebral blood flow velocity and systemic blood flow velocity. The CSvI decreased significantly at all three concentrations vs. 100% (isoflurane/sevoflurane: 0.75 MAC: 85 +/- 25%/81 +/- 23%, 1.0 MAC: 79 +/- 19%/74 +/- 16%, 1.25 MAC: 71 +/- 16%/79 +/- 21%; [mean +/- SD] P = 0.0001). CONCLUSIONS: The reduction of the CSvI vs. 100% indicates a direct reduction of cerebral blood flow velocity caused by isoflurane/sevoflurane, independently of systemic blood flow velocity.

Adult↗

[Changes in intraoperative and postoperative colloid oncotic pressure after open heart surgery especially in relation to non-blood priming or blood priming].

In order to evaluate the colloid oncotic pressure (COP) is useful index of hemodynamics and respiratory recovery after open heart surgery, cardiac index (CI), pulmonary capillary wedge pressure (PCWP), (A-a) Do2 and COP were measured in 34 patients during 48 hours after the cardiopulmonary bypass (CPB). The patients were divided into non-blood priming group: 11 patients and blood priming group (23 patients). In addition, blood priming group divided into two groups, one with dopamine (more than 15 micrograms/kg/min), epinephrine or intraaortic balloon pumping (severe blood subgroup, n = 6) and the other without these treatments after open heart surgery (slight blood subgroup n = 17). The COP levels in the non-blood priming group were significantly higher than those in the blood priming group from aortic cross-clamp to 10 minutes after aortic declamping (p < 0.01). From 1 to 48 hours after CPB, COP in the non-blood priming group and slight blood subgroups was significantly higher than severe blood subgroups (p < 0.05). CI and COP-PCWP levels were significantly higher in the non-blood priming group and slight blood subgroups than those in the severe blood group (p < 0.05). It is concluded that COP is useful index of hemodynamics and respiratory recovery after open heart surgery and our priming system without blood is effective in order to eliminate the blood transfusion.

Aged↗

Loss of shear stress induces leukocyte-mediated cytokine release and blood-brain barrier failure in dynamic in vitro blood-brain barrier model.

Brain ischemia is associated with an acute release of pro-inflammatory cytokines, notably TNF-alpha and IL-6 and failure of the blood-brain barrier. Shear stress, hypoxia-hypoglycemia, and blood leukocytes play a significant role in blood-brain barrier failure during transient or permanent ischemia. However, these mechanisms have not been studied as independent variables for in vitro ischemia. The present study, using a dynamic in vitro blood-brain barrier model, showed that flow cessation/reperfusion under normoxia-normoglycemia or hypoxia-hypoglycemia without blood leukocytes in the luminal perfusate had a modest, transient effect on cytokine release and blood-brain barrier permeability. By contrast, exposure to normoxic-normoglycemic flow cessation/reperfusion with blood leukocytes in the luminal perfusate led to a significant increase in TNF-alpha and IL-6, accompanied by biphasic blood-brain barrier opening. Enhanced permeability was partially prevented with an anti-TNF-alpha antibody. In leukocyte-free cartridges, the same levels of IL-6 had no effect, while TNF-alpha caused a moderate increase in blood-brain barrier permeability, suggesting that blood leukocytes are the prerequisite for cytokine release and blood-brain barrier failure during reduction or cessation of flow. These cells induce release of TNF-alpha early after ischemia/reperfusion; TNF-alpha triggers release of IL-6, since blockade of TNF-alpha prevents IL-6 release, whereas blockade of IL-6 induces TNF-alpha release. Pre-treatment of blood leukocytes with the cyclooxygenase (COX) inhibitor, ibuprofen, inhibited cytokine release and completely preserved blood-brain barrier permeability during the reperfusion period. In conclusion, loss of flow (flow cessation/reperfusion) independent of hypoxia-hypoglycemia plays a significant role in blood-brain barrier failure by stimulating leukocyte-mediated inflammatory mechanisms.

Animals↗

In vivo effects of snake venoms on passive and facilitated glucose transport across blood-ocular and blood-CSF barriers of the rat.

The transport of (3H)-3-0-methyl-D-glucose (mD-glu) and (14C)-L-glucose (L-glu) across blood-ocular and blood-CNS barriers was studied in rats with previously introduced (i.v.) lethal doses of lyophilized venom from one of three venomous snakes; mojave rattlesnake, Crotalus scutulatus; cottonmouth mocassin, Agkistrodon piscivorus; yellow cobra, Naja nivea. Transport rate constants calculated for mD-glu are taken as an indication of carrier-mediated transport, whereas L-glu constants are considered a measure of passive barrier permeability. C. scutulatus venom increased L-glu transport (+121%) across the blood-vitreous barrier. A passive increase in blood-vitreous permeability was also observed with mD-glu. This venom also increased passive L-glu entry rate into CSF (+160%). A. piscivorus venom also increased passive L-glucose entry into vitreous. However, whereas rattlesnake venom had little effect on blood-aqueous transport, cottonmouth venom may have also decreased carrier transport across this barrier. In addition, mD-glu transport from blood into CSF is decreased, suggesting a loss of carrier function across this barrier. N. nivea venom decreased the transport of both L-glu and mD-glu across the blood-aqueous, blood-vitreous and blood-CSF barriers, suggesting a possible decrease in cerebral blood flow as causative. There is also a possible increase in passive transport across the vitreous barriers, which may be in part countered by the decreased blood flow. Transport from aqueous into lens and cornea remained unchanged by the three venoms tested. It is suggested that components of rattlesnake and cottonmouth venoms alter transport barrier properties, with the blood-vitreous barrier being most susceptible to damage, whereas cobra venom likely decreases the supply of blood-borne substances to brain and ocular fluids and tissues by decreasing cerebral blood supply.

3-O-Methylglucose↗

Comparison of the efficacy of blood and polyethylene glycol-hemoglobin in recovery of newborn piglets from hemorrhagic hypotension: effect on blood pressure, cortical oxygen, and extracellular dopamine in the brain.

BACKGROUND: Successful blood substitutes, when infused in place of an equal volume of whole blood, provide similar delivery of oxygen to the tissues without introducing abnormalities in cellular metabolism. STUDY DESIGN AND METHODS: Equal volumes of whole blood (control), polyethylene glycol-hemoglobin solution at 6 g per dL, dextran solution, and physiologic saline were compared for their ability to reverse the effects of hemorrhagic hypotension on oxygenation and dopamine metabolism in the brain of newborn piglets. The decrease in mean arterial blood pressure was used as a measure of the hemorrhagic insult. Cerebral oxygen pressure was determined optically by the oxygen-dependent quenching of phosphorescence, and the extracellular level of dopamine in the corpus striatum was determined by in vivo microdialysis. RESULTS: Following a 2-hour stabilization after implantation of the microdialysis probe in the corpus striatum, the mean arterial blood pressure was decreased from 88 +/- 7 torr (control) to 42 +/- 5 torr by the removal of blood in a stepwise manner, over a period of 60 minutes. Decrease in mean arterial blood pressure caused a progressive stepwise decrease in cortical oxygen pressure from 48 +/- 5 torr to 16 +/- 4 torr at the end of bleeding. As a consequence of the decrease in oxygen pressure, extracellular dopamine increased progressively to about 2300 percent of the control value. When a volume of blood equal to that removed was returned and bicarbonate was injected to help correct arterial pH, blood pressure, cortical oxygen pressure, and extracellular dopamine all returned within the 20- to 30-minute recovery period to values not significantly different from control values. An equal volume of polyethylene glycol-hemoglobin solution, even with significantly lower hemoglobin content than whole blood, gave results comparable to those with whole blood. CONCLUSION: Polyethylene glycol-hemoglobin solution, like whole blood but in contrast to physiologic saline or dextran solution, was capable of returning the mean arterial blood pressure, cortical oxygen pressures, and extracellular dopamine nearly to control levels after acute blood loss in newborn piglets.

Animals↗

Is nurse-measured blood pressure a valid substitute for ambulatory blood pressure monitoring?

BACKGROUND: Because ambulatory blood pressure monitoring (ABPM) is not available everywhere, the objective of the study was to determine whether nurse-measured blood pressure could be an acceptable substitute to ABPM. METHODS: We analyzed the data of 2385 consecutive patients referred to our hypertension clinic for the performance of ABPM. Before ambulatory monitoring was performed, a nurse-measured BP was obtained three times using a Y-tube connecting the sphygmomanometer and the recorder. We compared the mean value of the three nurse-measured blood pressures with that of the 12h daytime ambulatory monitoring, considered as the reference. RESULTS: The difference between the nurse-measured and the ambulatory blood pressure was small but statistically significant, indicating that nurse-measured blood pressure tends to overestimate both diastolic and systolic blood pressure. The difference between the nurse blood pressure and ABPM was greater among treated hypertensive patients than untreated patients. To diagnose hypertension, defined as a blood pressure of over 140/90mmHg by ABPM, the positive predictive value of the nurse blood pressure was 0.81 and the negative predictive value 0.63. However, these predictive values could be improved with less stringent cut-off values of blood pressure. Thus, for a diastolic blood pressure above 100mmHg, the positive predictive value of nurse blood pressure was 0.55 and the negative predictive value 0.91. These figures were relatively similar for previously treated and untreated patients. CONCLUSION: Nurse blood pressure is less accurate than ABPM in diagnosing hypertension, defined as a blood pressure of over 140/90mmHg. It could, however, be an acceptable substitute, especially to exclude people who do not need to be treated, in situations where lower resources require a less rigorous definition of hypertension.

Adult↗

Determination of ambulatory blood pressure control in treated patients with controlled office blood pressures.

Office blood pressure measurement is the standard for assessing blood pressure control. Many patients, however, take their antihypertensive medication in the morning, so they are likely to have their office blood pressure measured during the maximal antihypertensive effect. It is therefore unknown whether patients deemed by office blood pressure to be controlled do in fact have 24h blood pressure control. The objectives of this study were to determine blood pressure control, including blood pressure control while the patients were awake and during the first 6 hours after awakening, by ambulatory blood pressure monitoring (ABPM) in treated hypertensive patients deemed by office blood pressure measurements to be controlled. A total of 103 patients on a stable antihypertensive regimen and deemed to be controlled in terms of office blood pressure values (mean office blood pressure <140/90mmHg) were enrolled. Patients were stratified by cardiovascular risk status and the number of antihypertensive medications that they were taking. Seventy-eight out of 103 participants successfully completed ABPM. The mean ambulatory blood pressure was greater than 135/85mmHg and 140/90mmHg while awake for 37% (95% confidence interval [CI] 26-48%) and 23% (95% CI 14-32%) of all patients respectively. Forty-eight per cent (95% CI 33-63%) of patients taking monotherapy versus 25% (95% CI 11-39%) of patients on multiple antihypertensive medications were uncontrolled (P=0.039) using 135/85mmHg as the reference value. Thirty-one per cent (95% CI, 17-44%) of patients on monotherapy versus 14% (95% CI 3-25%) of patients on multiple antihypertensive medication were uncontrolled (P=0.064) using 140/90mmHg instead. These results demonstrate that a high number of patients deemed by office blood pressure to be under control do not have adequate blood pressure control based on ABPM.

Adult↗

Introversion associated with large differences between screening blood pressure and home blood pressure measurement: The Ohasama study.

OBJECTIVE: To explore the effect of personality on screening blood pressures measured in clinical settings and home blood pressure measurements. METHODS: From 1997 to 1999, 699 participants underwent screening and home blood pressure measurements and completed the Japanese version of the short-form Eysenck personality questionnaire. An increased screening blood pressure was defined as screening blood pressure > or = 140/90 mmHg and an increased home blood pressure was defined as home blood pressure > or = 135/85 mmHg. RESULTS: Participants with lower extroversion scores (i.e., introversion) showed a greater difference between screening and home systolic blood pressure. The association between introversion and differences was statistically significant, even after adjustment for other possible factors (younger age, female, wide screening pulse pressure, never smoked, and no antihypertensive medication). The adjusted means of SBP differences were 7.3 and 4.4 mmHg among the lowest and highest extroversion quartiles, respectively (P for trend = 0.02). Other personality scores (psychoticism or neuroticism) were not associated with screening and home blood pressure differences. The incorporation of an extroversion score in the basic model consisting of the above factors that affected the difference between screening and home blood pressure slightly improved the prediction of a high home blood pressure. The area under the receiver operating characteristic curve increased by 0.037 among participants with high screening blood pressure and 0.006 for those with normal screening blood pressure compared with the basic model. CONCLUSION: Physicians may need to be aware of 'introverted' patients who have high blood pressure in clinic settings, because they have the potential for 'white-coat' hypertension.

Aged↗

Clinic blood pressure measurements and blood pressure load in the diagnosis of hypertension.

We have retrospectively compared the blood pressure load derived from 24 hour ambulatory blood pressure monitoring in patients with all clinic blood pressure readings elevated with those with only some elevated pressures to establish whether clinic readings alone are good predictors of blood pressure status. Fifty-seven patients attending a district general hospital hypertension clinic who were not on anti-hypertensive treatment were selected. Between two and six clinic readings were taken over a period of 1-6 months. Forty out of 57 patients had at least one clinic diastolic blood pressure reading of < 90 mmHg and, of these, 14 (35%) had a high blood pressure load and 26 (65%) had a normal blood pressure load. Patients with all diastolic blood pressure readings > 90 mmHg totalled 17 and of these 11 (65%) had high load and six (35%) had normal load. Patients with clinic diastolic blood pressure > 90 mmHg were significantly more likely to be truly hypertensive on the basis of blood pressure load than if one or more clinic readings was below 90 mmHg (P < 0.05). Diastolic pressures have some predictive power as to the blood pressure status defined by blood pressure load, but even consistently raised diastolic pressures do not necessarily indicate hypertension. Likewise one or more clinic diastolic blood pressure < 90 mmHg does not assuredly indicate normotension. Twenty-four hour ambulatory blood pressure monitoring may have an increasingly important role in the assessment of hypertension.

Adolescent↗

Increase in hepatic blood flow during early sepsis is due to increased portal blood flow.

Although hepatic blood flow increases significantly during early sepsis [as produced by cecal ligation and puncture (CLP)], it is not known whether this is due to the increase in portal or hepatic arterial blood flows. To study this, rats were subjected to CLP, after which they and sham-operated rats received either 3 or 6 ml normal saline/100 g body wt subcutaneously (i.e., all rats received crystalloid therapy). Blood flow in various organs was determined by using a radioactive microsphere technique at 5 and 20 h after CLP or sham operation. Portal blood flow was calculated as the sum of blood flows to the spleen, pancreas, gastrointestinal tract, and mesentery. Total hepatic blood flow was the sum of portal blood flow and hepatic arterial blood flow. A significant increase in portal blood flow and in total hepatic blood flow was observed at 5 h after CLP (i.e., early sepsis), and this was not altered by doubling the volume of crystalloid resuscitation after the induction of sepsis. In contrast, hepatic arterial blood flow during early sepsis was found to be similar to control; however, it was significantly reduced in late sepsis (i.e., 20 h after CLP). Cardiac output was significantly higher than the control in early sepsis. However, even in late sepsis, cardiac output and total hepatic blood flow were not significantly different from controls. These results indicate that the increased total hepatic blood flow during early hyperdynamic sepsis is solely due to the increased portal blood flow.

Animals↗

Lower blood pressure values in blood donors?

594 blood donors were studied to define the influence of regular blood donation on blood pressure. Blood pressures were compared at the first phlebotomy performed at the Padova Blood Unit, the 13-year phlebotomy, and the median between the two. As a control population, a cohort of 594 non-donors from the same general population similar to the blood donors was studied twice at a 15-year interval. Subjects had made on average 7.3 +/- 0.4 donations at the first step, 23 +/- 0.6 at the second, and 30.9 +/- 0.7 at the last step. Unadjusted systolic blood pressure regularly and significantly increased by 1.6% from the first phlebotomy to the second one and by 2.3% from the first to third. Adjusted systolic blood pressure, on the contrary, significantly decreased by 2.1% and by 2.7% respectively. Diastolic blood pressure tended to increase insignificantly, while the adjusted one did not change at all. The increase of systolic blood pressure from the first to second step directly correlated with the number of donations, and this also applied to differences between the first and the third. When the increase in age was introduced in the multiple regression analysis, systolic blood pressure rise from the first to third step showed an inverse correlation with the number of phlebotomies. Our data render suspect the results of epidemiological investigations which took into consideration cohorts of blood donors; although these cohorts may be anagraphically representative of a general population, repeated phlebotomies introduce a bias leading to the detection of misleadingly low blood pressure values in regular blood donors.

Adult↗

Circadian blood pressure rhythm and atrial natriuretic peptide in prednisolone-induced blood pressure elevation.

The effect of prednisolone, given as a 4-day oral treatment, on 24-h ambulatory blood pressure rhythm, vasoactive hormones and correlation between blood pressure and vasoactive hormones were studied in 11 healthy men. Blood pressure was monitored at intervals of 15 min during the day and of 30 min during the night. Plasma concentrations of angiotensin II, aldosterone, atrial natriuretic peptide (ANP) and arginine vasopressin and serum concentration of insulin were measured in the morning during basal conditions. The 24-h systolic, diastolic and mean blood pressures were significantly higher after prednisolone treatment. Waking blood pressure was not significantly changed, but sleeping systolic and mean blood pressures were significantly elevated after treatment. The nocturnal systolic blood pressure fall was less pronounced after treatment (before 22%, and after 16%, p<0.01), whereas the nocturnal, mean and diastolic dips were preserved. ANP was significantly increased by prednisolone treatment, from 10.1 to 14.6 pmol l-1, p<0.005. The changes in concentration of ANP were significantly correlated to the changes in 24-h diastolic blood pressure (r = -0.63, p<0.05), 24-h mean blood pressure (r = -0.68, p<0.05), waking diastolic blood pressure (r = 0.83, p<0.01) and waking mean blood pressure (r = -0.67, p<0.01). We found that short-term prednisolone treatment elevated the overall 24-h blood pressure, reduced systolic blood pressure fall during sleep, and increased plasma concentration of ANP, and that the increase in ANP was inversely correlated to the increase in blood pressure. We suggest that the increase in ANP is a secondary and compensatory phenomenon which at least to some extent counteracts the hypertensive and sodium retaining effect of prednisolone.

Adult↗

Blood loss and use of blood in internal mammary artery and saphenous vein bypass grafting with and without adding a single, low-dose of aprotinin (2 million units) to the pump prime.

In comparison with saphenous vein bypass grafting (SVG) without a pleurotomy, internal mammary artery (IMA) bypass surgery might enhance more blood loss by the intrathoracic wound and a wide opened pleura. Low-dose aprotinin (Trasylol) reduces blood loss and consequently, the use of homologous blood. We studied the blood loss and blood requirements peri-operatively in 70 patients, who underwent either SVG-(n = 35) or IMA-surgery (n = 35) without aprotinin and another 70 patients who underwent SVG- (n = 35) or IMA-surgery (n = 35) with a single dose of aprotinin, added to the pump prime. We also determined the hemoglobin and total protein content of the shed blood. Without aprotinin administration, the mean intra-operative and post-operative blood loss was significantly less (p < 0.01) in SVG-patients, than in IMA-patients. We observed no statistical differences in the mean blood requirements between SVG- and IMA-surgery (1.2 units and 1.6 units). The use of any homologous blood product was similarly averted in 39% of the SVG-patients, and in 48% of the IMA-patients. Treatment with aprotinin significantly lessened (p < 0.01) the mean intra-operative blood loss only in IMA-patients. Post-operative blood loss was diminished with 45% in IMA-patients and 33% in SVG-patients, being significantly less (p < 0.01) after SVG, than after IMA-surgery. Blood requirements were significantly lowered (p < 0.01): a total mean of 0.2 units in SVG- and 0.6 units in IMA-patients (NS). Any homologous blood product was prevented in 78% of the IMA-patients and in 87% of the SVG-patients (NS). The mean loss of hemoglobin and total protein per 100 ml of shed blood was similar in IMA-, and SVG-patients with or without aprotinin, although aprotinin diminished the total amounts in both groups with 50% (p < 0.01).

Adult↗

[Ambulatory blood pressure monitoring: significance of blood pressure variability for progression of heart hypertrophy].

It is known that ambulatory blood-pressure monitoring gives a better prediction of target organ damage and prognosis than clinical blood pressure. Many studies have found a closer correlation for ambulatory blood pressure with left ventricular hypertrophy than clinical blood pressure. One question that is discussed controversely is whether the variability of blood pressure is also a determinant of target organ damage independent of the average level. In 52 patients with elevated casual blood pressure a 24-h ambulatory blood-pressure measurement (Space Labs 90202) was performed and left ventricular hypertrophy was evaluated by M-mode echocardiography. The following parameters of blood pressure variability were calculated from the profiles: the standard deviation of the mean value, the variation coefficient and the parameter of variability as proposed by Schächinger et al. Furthermore a Fourier analysis of the blood pressure data was performed to quantify blood pressure variability. We found no statistically significant correlation between blood pressure variability and left ventricular mass. However, systolic and diastolic blood pressure level showed a significant correlation with left ventricular hypertrophy (r = 0.45 and r = 0.49, p < 0.05). Thus, blood pressure variability as calculated from the ambulatory, non-invasive blood pressure monitoring is a poor predictor for secondary damage of the heart.

Adult↗

[Are home blood pressure measurements and 24-hour ambulatory recordings superior to office measurements? Comparison of 3 blood pressure recording methods in a study of cilazapril versus atenolol].

Self-assessment of blood pressure and ambulatory blood pressure monitoring (ABPM) are being more widely used in the diagnosis and therapy of hypertension, in addition to office blood pressure measurement. The present multicenter double-blind study compared cilazapril 2.5 to 5 mg (n = 26) to atenolol 50 to 100 mg (n = 27) over a period course of eight weeks. Office blood pressures in the morning before medication, ABPM over 24 h and self assessment of the blood pressure in the morning and evening were taken. The aim of the study was to find out if the results of ABPM and self assessment of blood pressure are similar when compared to office blood pressure measurement. After four weeks of therapy both cilazapril and atenolol achieved a significant and comparable reduction of blood pressure, which did not change significantly afterwards. Both medications showed a comparable blood pressure control over 24 h. with a once-a-day regimen. The comparison of the three techniques of blood pressure measurement demonstrates that ABPM results in significantly lower average daily values than office blood pressure measurement and that the self-assessed blood pressure values in most cases lie in-between. Although the diastolic ambulatory daily values were on the average 9 mmHg lower than the corresponding office values, it was not possible for an individual patient to accurately predict the ambulatory value obtained by to his office blood pressure value. Similar results were found for the values according to self assessment of blood pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Effect of nocturnal blood pressure measurement on sleep and blood pressure during sleep.

Nocturnal hypertension is of diagnostic interest and has important prognostic and therapeutic implications. Nighttime blood pressure can easily be measured using ambulatory blood pressure monitoring (ABPM). However, during nocturnal ambulatory blood pressure measurement pump noise, tactile stimuli and pressure produced by cuff inflation may alter the quality of sleep and subsequently influence the physiological fall of night time blood pressure. Eight studies were performed to determine whether non-invasive automated blood pressure monitoring during day and/or night provokes alert reaction, arousal, sleep disturbances and changes in blood pressure and/or heart rate. From these studies it can be concluded: 1) Nighttime blood pressure can be evaluated properly using ABPM. 2) Nocturnal blood pressure is not overestimated by ABPM. 3) ABPM does not induce an alarm reaction and a blood pressure rise when monitored with a silently operating recorder. 4) Sleep is often disturbed by blood pressure measurement without provoking a blood pressure increase. 5) In older patients blood pressure measurement and age-related alterations in sleep quality may influence each other. A patient's protocol has to be carried out and sleep quality should be recorded to provide a proper interpretation of nocturnal blood pressure behavior. ABPM is an important and valuable method to record nocturnal blood pressure for diagnostic and therapeutic purposes.

Arousal↗

Relationship of office, home, and ambulatory blood pressure to blood glucose and lipid variables in the PAMELA population.

Alterations in blood glucose and cholesterol are more frequently detectable in hypertensive than in normotensive conditions. However, no information exists as to whether this phenomenon involves only office or also home and 24-hour ambulatory blood pressure (ie, when values are representative of daily life). In 2045 subjects enrolled in the Pressioni Arteriose Monitorate E Loro Associazioni (PAMELA) study, we measured home, 24-hour, and office blood pressure. Measurements also included fasting blood glucose and serum total and HDL cholesterol values. Prevalence of diabetes (> or =126 mg/dL or use of antidiabetic drugs), impaired fasting blood glucose (> or =110 to <126 mg/dL), and hypercholesterolemia (serum total cholesterol > or =240 mg/dL or 200 mg/dL) increased progressively from "optimal" to "normal," "high-normal," and "elevated" office systolic or diastolic blood pressure. Fasting blood glucose and total serum cholesterol also increased progressively from the first to the fourth group, with HDL cholesterol values showing a concomitant progressive decrease. This was also the case for quartiles of office, home, and 24-hour blood pressure. In the whole population, there was a positive correlation between serum cholesterol or blood glucose and all blood pressure values (P always <0.0001), with a much smaller and less consistent relationship with heart rate. In a multivariate analysis that included gender, body mass index, age, and antihypertensive treatment, all blood pressure values remained highly significantly related to values of either metabolic variables. Thus, in the PAMELA population, glucose and lipid values are independently related to blood pressure. This is also the case when daily life blood pressure values are considered.

Adult↗

Rethinking blood shield statutes in view of the hepatitis C pandemic and other emerging threats to the blood supply.

Researchers have identified at least twenty-five pathogens that can be transmitted through blood transfusions. Four percent of patients who receive the average amount of blood during a transfusion are at risk of being infected with a contaminated unit, and exposed to the danger of serious adverse reactions, including future debilitating conditions. Victims of transfusion-related diseases, however, generally have been unsuccessful when making claims against the purveyors of blood products because of blood shield statutes that were initially enacted in response to unknown pathogens that made the blood an "unavoidably unsafe" product. Today, blood purveyors are aware of the possibility of epidemics from unsafe blood and have continued to research and supervise the blood supply to create mechanisms that detect and inactivate various blood-borne pathogens. In response to the current and advancing methods of blood purification, this Article suggests that a hybrid strict liability/negligence standard be implemented to ensure advancements in safety of blood transfusions. A strict liability standard should attach for infections that can be detected and eliminated through current testing and inactivation methods. A negligence standard should govern infections for which no current test or inactivating method is available. Under this approach, blood purveyors would be compelled to take account of the risks of any manufacturing decisions that they make, and they would not enjoy the freedom from liability that the blood shield statutes now provide. The costs necessary to ensure compliance with this hybrid structure are small in comparison to the social and economic costs exacted by thousands of transfusion-related diseases.

Blood Banks↗