Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ASD”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26Linked to original sources

Affect regulation and temperament in children with Autism Spectrum Disorder.

Affect regulation (AR) and temperament were examined in children with Autism Spectrum Disorder (ASD). To determine AR, children were exposed to a mildly frustrating situation. Temperament was assessed by the Children's Behavior Questionnaire (CBQ). Children with ASD showed greater variability in AR and used less effective AR strategies compared to controls. Lower academic ability was associated with less effective AR strategies for the ASD while for the controls older age predicted more effective AR strategies. Those with ASD were lower than controls in Attention Focusing, Inhibitory Control, and Soothability. Of the three overarching temperament factors of the CBQ, only Effortful Control but not Negative Affectivity and Surgency/Extraversion distinguished those with ASD from controls. For the ASD group, higher academic ability predicted higher Negative Affectivity. Fewer symptoms and older chronological age predicted higher Effortful Control.

Achievement↗

Right-to-left shunt across atrial septal defect related to tricuspid regurgitation: assessment by transesophageal Doppler echocardiography.

The purpose of this study was to assess the factors involved in the development of the right-to-left (R-L) shunt in patients with atrial septal defect (ASD), especially the role of tricuspid regurgitation (TR). Thirty-one consecutive patients with ASD underwent transesophageal Doppler echocardiography to determine the size of ASD, the shunt flow, and the TR flow, and they were compared with hemodynamics examined by cardiac catheterization. Sixteen patients with the R-L shunt were older (53 +/- 11 vs 34 +/- 9 years; p < 0.001) and had higher pulmonary arterial pressure (36 +/- 17 vs 25 +/- 5 mmHg; p < 0.05) and a greater Qp/Qs (3.6 +/- 1.2 vs 2.4 +/- 0.9 L/min; p < 0.01) as compared with 15 patients with the pure left-to-right shunt. In six of 21 patients with TR, the regurgitant flow oriented toward ASD and blew into the left atrium through the defect. Besides the deviation of TR flow, the prevalences of the maximum diameter of ASD > 2.5 cm and the maximal TR flow area > 4 cm2 were significantly higher in the six patients as compared with patients with TR not related to the R-L shunt (p < 0.05 and p < 0.05), despite the pulmonary arterial pressure being similar in the two groups. Reversal of pressure gradient between the left and right atrium was not observed during the cardiac cycle in all patients. In conclusion, TR is a determinant of the R-L shunt in patients with ASD even in the absence of the reversal of pressure gradient between the left and right atrium.

Adolescent↗

Intracardiac ultrasonographic assessment of atrial septal defect area: in vitro validation and technical considerations.

Assessment of atrial septal defect (ASD) size and shape is important for planning and guiding its transcatheter occlusion and can potentially be achieved by intracardiac ultrasonography (ICUS). ICUS accuracy, however, must first be established against stable standards and technical imaging requirements defined. We therefore used 10, 20, and 30 MHz ICUS catheters to examine 17 ASDs that were 0.16 to 6.7 cm2 in area and were surgically created in excised ovine hearts with 10, 20, and 30 MHz ICUS catheters. ASD shape and area by ICUS were compared with direct video images of the actual ASD. In all instances minimal area by ICUS pullback agreed well with actual values (y = 1.04x + 0.2, SEE = 0.23 cm2, r = 0.99) and corresponded well with defect shapes. The maximum angle between ultrasonography beam and septal plane allowing for complete ASD visualization was 20 degrees. The angle depended on transducer frequency and septal thickness. This new technique has potential value for the accurate assessment of ASD shape and size and may be especially useful in the setting of transcatheter occlusion.

Animals↗

Detection of atrial septal defect by right sternal border echocardiography.

The atrial septum can be visualized by right sternal border 2-dimensional echocardiography (2-D echo). To evaluate the usefulness of this approach in the evaluation of atrial septal defect (ASD), 50 patients who underwent cardiac catheterization were studied by 2-D echo. Twenty-one patients (Group A) had ASD (3 ostium primum, 18 ostium secundum) and 29 (Group B) had mitral valve disease and an intact atrial septum. Subcostal and right sternal border approaches were used to visualize the atrial septum. Both approaches identified the 3 cases of ostium primum ASD; secundum ASD was identified using the subcostal approach in 11 patients and using the right sternal border approach in 13. In 15 patients the ASD was imaged at least by 1 of the 2 approaches. Two-dimensional contrast echocardiography showed a positive or negative contrast effect in 13 of 18 cases (12 with standard approaches, 11 with right sternal border approach). In all patients in Group B, the right sternal border approach showed an intact atrial septum. Thus, the right sternal border approach is a useful approach that increases the sensitivity of 2-D echo in the diagnosis of ASD.

Adolescent↗

Diagnosis and quantitative evaluation of secundum-type atrial septal defect by transesophageal Doppler echocardiography.

Transesophageal echocardiography (horizontal sector scan) was performed in 11 patients with secundum atrial septal defect (ASD). In all 11 patients, transesophageal echocardiography presented the definite visualization of the defect and a clear laminar shunt flow that showed its 2 peaks in late systole and late diastole. We estimated the size of ASD and a shunt volume across the defect by using transesophageal echocardiography. The defect size determined by transesophageal echocardiography was correlated with the surgical measurement (horizontal width, r = 0.92, p less than 0.001; vertical length, r = 0.85, p less than 0.01). A significant high correlation was shown between the shunt volume measured by transesophageal echocardiography and that by Fick's method (r = 0.87, p less than 0.01). There was no significant correlation between the pulmonary to systemic flow volume (ratio) and the mean shunt flow velocity across ASD, although a high linear correlation was observed between the pulmonary to systemic flow ratio and the defect size in horizontal direction (r = 0.82, p less than 0.01). Transesophageal echocardiography used for diagnosis and quantitative evaluation of ASD could be performed easily and satisfactorily within 10 minutes. Thus, transesophageal echocardiography is a useful method in evaluation of the defect size and the shunt flow volume of ASD. The mean shunt flow velocity was not a reliable index for estimating the shunt flow volume. The defect size might be a valuable determinant of left-to-right shunt volume in ASD.

Adolescent↗

Associated atrial septal defects increase perioperative morbidity after ventricular septal defect repair in infancy.

Although closure of ventricular septal defects (VSDs) is currently associated with a relatively low risk, infants with associated atrial septal defects (ASDs) seem to have a higher perioperative morbidity. To clarify this impression, we reviewed our entire experience (since 1977) with closure of simple VSDs in 163 infants (age, < or = 12 months). Of these, 57 had significant ASDs (ASD-VSD subgroup). Hospital mortality was 3.7% (6/163) overall and 1.4% (2/145) since 1980. Actuarial survival at 10 years was 92% +/- 5%. Significant morbidity occurred in 15.5% (16/103) of the VSD subgroup versus 48.1% (26/54) of the ASD-VSD subgroup (p < or = 0.001). Multivariate analysis identified the presence of multiple VSDs and early date of operation as risk factors for hospital death, and younger age, an associated ASD, the size of the VSD, and use of hypothermic circulatory arrest as risk factors for significant perioperative morbidity. Compared with the VSD subgroup, the ASD-VSD subgroup had a higher hospital mortality (5.3% [3/57] versus 2.8% [3/106]), were younger (5.1 +/- 2.9 versus 7.2 +/- 2.9 months; p = 0.001), had a higher preoperative pulmonary artery pressure (70.2 +/- 19.0 versus 62.7 +/- 21.8 mm Hg; p = 0.08), needed more inotropic support (12.3% versus 3.7%; p = 0.07), needed more prolonged ventilation (3.3 versus 1.8 days; p = 0.02), and had longer postoperative hospital stays (11 versus 8 days; p = 0.005).(ABSTRACT TRUNCATED AT 250 WORDS)

Age Factors↗

Short- and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer Septal Occluder.

BACKGROUND: The Amplatzer Septal Occluder (ASO) (AGA Medical Corp, Golden Valley, Minn) has gained wide acceptance for transcatheter closure of atrial septal defect (ASD). We conducted this study to evaluate the short-and intermediate-term results of ASD closure with the ASO and to determine the impact of deficient rim on the results. METHODS: Between March 1999 and February 2003, 197 patients underwent attempted transcatheter closure of ASD with the ASO. The size of the selected device either equaled or was 1 to 2 mm larger than the stretched diameter of the defect. Transesophageal echocardiography was used to monitor the implantation procedure. One hundred and fourteen patients (58%) with a deficiency in 1 rim (<5 mm) were included as group I, and the remaining 83 patients with adequate rims comprised group II. RESULTS: The mean stretched diameter measured with the balloon catheter was 18.6 +/- 6.7 mm (range 7.1-37.2 mm). Deployment of the ASO was successful in 191 (97%) patients and failed in 6. There was no significant difference between the 2 groups in the success rate for ASD closure (110/114 vs 81/83). Repositioning of the device was required in 28 patients: 21 in group I and 7 in group II (21/114 vs 7/83, P >.05) The mean stretched diameter of the defect in these 28 patients was significantly larger than that in those who did not require repositioning of the device (27.3 +/- 5.7 vs 17.1 +/- 5.5 mm, P <.01). Three patients experienced severe complications: 1 had transient complete atrioventricular block, 1 had tamponade requiring drainage, and 1 had dislodgement of the device requiring emergent operation. One had a distal embolism to a fingertip. Echocardiography at 1 day, 3 months, 6 months, 12 months, and 24 months after the procedure showed residual shunts in 37/191 (19%), 15/189 (8%), 11/176 (6%), 7/131 (5%), and 3/72 (4%) patients, respectively. CONCLUSIONS: The ASO is a safe and effective device for the transcatheter closure of ASD. Deficiency in 1 rim, particularly the superior anterior rim, does not influence the success rate of ASD closure.

Adolescent↗

CardioSEAL/STARflex versus Amplatzer devices for percutaneous closure of small to moderate (up to 18 mm) atrial septal defects.

BACKGROUND: The Amplatzer septal occluder (ASO) allows the percutaneous closure of small to very large atrial septal defects (ASDs). The CardioSEAL/STARflex (CS/SF) can be used only for closure of small to moderate ASDs (stretch size up to 18 mm). These 2 devices are widely used in clinical practice. Therefore, a comparison of their use in the closure of small to moderate ASDs is needed. METHODS: From December 1996 to September 2002, 274 consecutive patients (mean age 20.3 +/- 17 years) underwent percutaneous closure of small to moderate ostium secundum ASDs. The CS/SF device was used in 121 patients, and the ASO was used in 153. RESULTS: There were no differences in age, sex ratio, or pulmonary/systemic flow ratio. Stretch size of the defect was higher in the ASO group (13.6 +/- 3.5 mm vs 15.5 +/- 3.2 mm, P <.001). Procedure time and fluoroscopy time were shorter in patients treated with the ASO (61 +/- 21 vs 75 +/- 32 min, P <.0003, and 11.6 +/- 9 vs 23.8 +/- 17.4 min, P <.0001, respectively). Residual shunt at procedure and discharge was significantly more frequent in the CS/SF group (P <.0001). There were no differences in the complication rate for the 2 groups (CS/SF 4/121 vs ASO 6/153). Length of follow-up was longer in the CS/SF group (24 +/- 14 vs 16 +/- 9 months, P =.0001). Residual shunting was significantly more frequent in the CS/SF group during follow-up, while closure rate reached 100% after 1 month in ASO group. CONCLUSIONS: The 2 devices are clinically safe and effective in ASD closure. However, percutaneous closure of small to moderate ASDs with ASO is quicker and provides an higher rate of complete occlusion.

Adolescent↗

Reduced plasma apelin levels in patients with autistic spectrum disorder.

BACKGROUND: Dysregulation of the vasopressin (AVP) system has been implicated in the pathogenesis of autistic spectrum disorder (ASD). Apelin is a recently discovered neuropeptide that could counteract AVP actions and whose receptors are colocalized with vasopressin in hypothalamic magnocellular neurons. Aims of the present study were to investigate circulating levels of apelin in patients with ASD and to assess their correlation with plasma AVP concentrations. METHODS: Plasma levels of apelin and AVP were measured in a total of 18 patients with ASD and 21 age- and gender-matched healthy comparison subjects. The Childhood Autism Rating Scale (CARS) was used to assess the severity of autistic symptoms. RESULTS: Significantly reduced levels of apelin (p < 0.001) and elevated concentrations of AVP (p = 0.02) were found in ASD patients as compared to controls. Additionally, a significant inverse correlation between apelin and AVP levels was found within the ASD group (r = -0.61; p = 0.007), but not in healthy participants (r = -0.26; p = 0.25). Multivariate linear regression analysis showed that only AVP concentrations independently predicted apelin values in ASD individuals (beta = -0.42, t = 2.63, p = 0.014). No correlation was seen between apelin levels and CARS scores (r = -0.10; p = 0.68). CONCLUSIONS: Our findings of a significantly reduced peripheral level of apelin coupled with elevated AVP point to a subtle but definite vasopressinergic dysfunction in autism that could play a role in the etiopathophysiology of this disorder in humans.

Adolescent↗

Combined atrial septal defect surgical closure and irrigated radiofrequency ablation in adult patients.

BACKGROUND: Atrial arrhythmias are relatively common among patients over 40 years old with atrial septal defect (ASD) and are a precipitating cause of heart failure. Surgical closure of the ASD in these patients is feasible and is associated with a low mortality rate and a beneficial effect on the clinical status; however the occurrence of atrial arrhythmia does not decrease after surgery. We present the results of our preliminary experience with surgical ASD closure combined with intraoperative irrigated radiofrequency (IRF) ablation in adult patients. METHODS: During a 26-month period between September 2002 and December 2004, 15 patients more than 40 years old with ASD and atrial arrhythmia underwent elective surgical closure of the defect and intraoperative IRF ablation. All patients had supraventricular arrhythmias: 8 had permanent atrial fibrillation, whereas 7 had previous episodes of atrial flutter or intra-atrial reentry tachycardia. The biatrial approach (Cox-Maze III procedure) was used in 7 patients and a right-sided Maze procedure (ablation lines on the right atrium only) was carried out in the remaining 8 patients. RESULTS: All patients survived the procedure. Fourteen patients left the operating room in sinus rhythm and 1 had a pacemaker implanted. There were no complications resulting from the IRF ablation. All 15 patients survived over the average follow-up period of 24 months. Thirteen patients were still in sinus rhythm, 1 had pacemaker rhythm, and only 1 (1 of 15; 6.5%) suffered a recurrence of atrial fibrillation 3 months after the procedure. CONCLUSIONS: We suggest adding intraoperative IRF ablation during surgical closure of an ASD in all adult ASD patients with arrhythmias. The IRF ablation is easy to perform, safe, and effective.

Adult↗

Placental trophoblast inclusions in autism spectrum disorder.

BACKGROUND: Microscopic examination of placental tissue may provide a route to assessing risk and understanding underlying biology of autism. METHODS: Occurrence of a distinctive microscopic placental morphological abnormality, the trophoblast inclusion, was assessed using archived placental tissue. The rate of occurrence of trophoblast inclusion-positive slides observed for 13 individuals with autism spectrum disorder (ASD) was compared to the rate in an anonymous consecutive birth cohort. RESULTS: The occurrence of inclusion positive slides was significantly greater in the ASD group compared to the control group (6/27 slides, 22.2% vs. 12/154, 7.8%; Fisher Exact Test, two-tailed p = .033; relative risk 2.85). The proportion of positive cases was also greater in the ASD group (5/13 cases, 38.5% vs. 8/61, 13.1%; Fisher Exact, two-tailed p = .044; relative risk 2.93). Behavioral severity scores did not differ across groups of inclusion positive (N = 4) and negative (N = 8) ASD individuals. CONCLUSIONS: Although probably not functionally detrimental or causative, the greater occurrence of placental trophoblast inclusions observed in ASD individuals may reflect altered early developmental processes. Further research is required to replicate the basic finding, to understand the basis for the trophoblastic abnormality, and to determine the utility of the measure in early detection of ASD.

Adolescent↗

Caudate nucleus volume and cognitive performance: Are they related in childhood psychopathology?

BACKGROUND: Impaired neuropsychological test performance, especially on tests of executive function and attention, is often seen in children diagnosed with autism spectrum disorders (ASD). Structures involved in fronto-striatal circuitry, such as the caudate nucleus, may support these cognitive abilities. However, few studies have examined caudate volumes specifically in children with ASD, or correlated caudate volumes to cognitive ability. METHODS: Neuropsychological test scores and caudate volumes of children with ASD were compared to those of children with bipolar disorder (BD) and of typically developing (TD) children. The relationship between test performance and caudate volumes was analyzed. RESULTS: The ASD group displayed larger right and left caudate volumes, and modest executive deficits, compared to TD controls. While caudate volume inversely predicted performance on the Wisconsin Card Sorting Test in all participants, it differentially predicted performance on measures of attention across the ASD, BD and TD groups. CONCLUSIONS: Larger caudate volumes were related to impaired problem solving. On a test of attention, larger left caudate volumes predicted increased impulsivity and more omission errors in the ASD group as compared to the TD group, however smaller volume predicted poorer discriminant responding as compared to the BD group.

Adolescent↗

En2 knockout mice display neurobehavioral and neurochemical alterations relevant to autism spectrum disorder.

Autism spectrum disorder (ASD) is a prevalent and inheritable neurodevelopmental disorder. Recent human genetic studies are consistent with the homeobox transcription factor, ENGRAILED 2 (EN2), being an ASD susceptibility gene. En2 knockout mice (En2(-/-)) display subtle cerebellar neuropathological changes similar to what has been observed in the ASD brain. To investigate whether En2(-/-) mice displayed abnormal behavior relevant to ASD, they were monitored in tasks designed to assess social maturation as well as learning and memory. Deficits in social behavior were detected in En2(-/-) mice across maturation that included decreased play, reduced social sniffing and allogrooming, and less aggressive behavior. Deficits in two spatial learning and memory tasks were also observed. Because locomotor activity was a component of many of the behavioral tasks, this was measured at various stages of development. Locomotor activity was not compromised in the knockout. However, a more thorough analysis of motor behavior in En2(-/-) mice revealed deficits in specific motor tasks. To determine whether neurochemical changes were associated with these behavioral phenotypes, monoamine levels in specific brain regions were assessed. A cerebellar-specific increase in serotonin and its metabolite was observed. Interestingly, several reports have suggested that the serotonin pathway is affected in ASD. We conclude that En2(-/-) mice display behavioral and neurochemical changes, in addition to genetic and neuropathological changes, relevant to ASD. Therefore, these mice may be useful as an animal model of autism.

Aggression↗

Adult Still's disease reflects a Th2 rather than a Th1 cytokine profile.

Adult Still's disease (ASD) is a chronic multisystemic disease. Extraordinarily high serum levels of IL-18 in ASD patients have been described, whereas the mechanism remains to be clarified. This study aimed to evaluate proinflammatory cytokines and to consider their pathological roles. In patients with rheumatic diseases (n = 151), blood samples were taken at the active phase and the serum levels of IL-18 and other proinflammatory cytokines were measured by ELISA. The extra-high levels of IL-18 were confirmed selectively in ASD patients (n = 10). In the active phase of ASD patients, the levels of IL-6 were elevated accordingly, but IL-1beta and TNF-alpha were undetectable. As to Th1-Th2 cytokines, the levels of IL-4 and IL-13, but not INF-gamma, IL-12, or IL-2, were elevated in all ASD patients examined. Moreover, the serum levels of IL-18 showed a good correlation with those of IL-4, suggesting that ASD reflects a Th2 rather than a Th1 cytokine profile.

Adolescent↗

EEG evidence for mirror neuron dysfunction in autism spectrum disorders.

Autism spectrum disorders (ASD) are largely characterized by deficits in imitation, pragmatic language, theory of mind, and empathy. Previous research has suggested that a dysfunctional mirror neuron system may explain the pathology observed in ASD. Because EEG oscillations in the mu frequency (8-13 Hz) over sensorimotor cortex are thought to reflect mirror neuron activity, one method for testing the integrity of this system is to measure mu responsiveness to actual and observed movement. It has been established that mu power is reduced (mu suppression) in typically developing individuals both when they perform actions and when they observe others performing actions, reflecting an observation/execution system which may play a critical role in the ability to understand and imitate others' behaviors. This study investigated whether individuals with ASD show a dysfunction in this system, given their behavioral impairments in understanding and responding appropriately to others' behaviors. Mu wave suppression was measured in ten high-functioning individuals with ASD and ten age- and gender-matched control subjects while watching videos of (1) a moving hand, (2) a bouncing ball, and (3) visual noise, or (4) moving their own hand. Control subjects showed significant mu suppression to both self and observed hand movement. The ASD group showed significant mu suppression to self-performed hand movements but not to observed hand movements. These results support the hypothesis of a dysfunctional mirror neuron system in high-functioning individuals with ASD.

Adolescent↗

Characterization of atrial septal defect assessed by real-time 3-dimensional echocardiography.

OBJECTIVE: The aim of this study was to describe a quantitative evaluation by real-time 3-dimensional (3D) echocardiography (RT-3DE) of atrial septal defect (ASD) and atrial septum that is important for patient selection for transcatheter closure, and to assess the reliability of RT-3DE findings compared with operation. METHODS: Forty-five patients, who were scheduled for surgical or transcatheter closure of an ASD, were included in the study. RESULTS: In 43 patients (96%), 3D reconstructions allowed optimal imaging of the ASD. The correlations between the ASD maximal diameter by RT-3DE and operation or balloon sizing were excellent (r > 0.95). All surrounding rims of the atrial septum could be assessed on 3D reconstruction; except for the aortic rim, a cross-sectional reconstruction was created mimicking the transesophageal echocardiographic cross section (r > 0.92). CONCLUSION: RT-3DE allows accurate determination of ASD location, ASD size, and surrounding tissue of the atrial septum, and might replace transesophageal echocardiography for patient selection for surgical or transcatheter closure.

Child, Preschool↗

Determinants of cardiopulmonary functional improvement after transcatheter atrial septal defect closure in asymptomatic adults.

OBJECTIVES: We sought to evaluate the course of cardiopulmonary function after transcatheter atrial septal defect (ASD) closure and to identify the physiopathologic mechanisms leading to this change. BACKGROUND: Conflicting reports exist on cardiopulmonary functional improvement in asymptomatic adults after transcatheter closure of a secundum ASD. METHODS: Thirty-two consecutive adults (13 males; age 42.6 +/- 16.7 years) underwent maximal cardiopulmonary exercise testing and transthoracic echocardiography both on the day before and six months after transcatheter ASD closure. Mean pulmonary artery pressure, pulmonary to systemic flow ratio (Qp/Qs), and ASD diameter were measured before closure. RESULTS: Peak oxygen uptake (Vo(2)) (p < 0.001), peak oxygen pulse (p = 0.0027), and vital capacity (p = 0.0086) improved after ASD closure, although peak heart rate did not. A significant correlation was found between peak Vo(2) improvements and Qp/Qs (p = 0.0013). Left ventricular ejection fraction (LVEF) (p < 0.0001) and left ventricular end-diastolic diameter (LVEDD) (p < 0.0001) significantly increased after six months, although left ventricular end-systolic diameter did not. Right ventricular long- and short-axis dimensions decreased (both p < 0.0001). Peak Vo(2) and of peak oxygen pulse improvements correlated to both LVEF (p = 0.0009 and 0.0019, respectively) and LVEDD (p < 0.0001 and 0.032, respectively) increments. The decrease of both long- and short-axis right ventricular dimensions positively correlated to both LVEF and LVEDD improvements. The improvement in LVEF correlated to Qp/Qs (p = 0.0026). CONCLUSIONS: Transcatheter ASD closure leads to a significant improvement in cardiopulmonary function within six months, via an increase in peak oxygen pulse. An increase in both left ventricular stroke volume and cardiac output due to a positive ventricular interaction is the mechanism leading to improved peak Vo(2).

Adolescent↗

Association of interatrial shunts and migraine headaches: impact of transcatheter closure.

OBJECTIVES: To examine the relationship between patent foramen ovale (PFO) or atrial septal defect (ASD) with the incidence of migraine headache (MHA) and assess whether closure of the interatrial shunt in patients with MHA would result in improvement of MHA. BACKGROUND: Migraine headache is present in 12% of adults and has been associated with interatrial communications. This study examined the relationship between PFO or ASD with the incidence of MHA and assessed whether closure of the interatrial shunt in patients with MHA would result in improvement of MHA. METHODS: A sample of 89 (66 PFO/23 ASD) adult patients underwent transcatheter closure of an interatrial communication using the CardioSEAL (n = 22), Amplatzer PFO (n = 43), or the Amplatzer ASD (n = 24) device. RESULTS: Before the procedure, MHA was present in 42% of patients (45% of patients with PFO and 30% of patients with ASD). At three months after the procedure, MHA disappeared completely in 75% of patients with MHA and aura and in 31% of patients with MHA without aura. Of the remaining patients, 40% had significant improvement (>or=2 grades by the Migraine Disability Assessment Questionnaire) of MHA. CONCLUSIONS: Transcatheter closure of PFO or ASD results in complete resolution of MHA in 60% of patients (75% of patients with migraine and aura) and improvement in symptoms in 40% of the remaining patients. Interatrial communications may play a role in the etiology of MHA either through paradoxic embolism or humoral factors that escape degradation in bypassing the pulmonary circulation. A randomized trial is needed to determine whether transcatheter closure of interatrial shunts is an effective treatment for MHA.

Adolescent↗