Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “atomic force microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Atomic force microscopy observations of acyl chains in phospholipids.

The potential use of atomic force microscopy (AFM) to image the mode of assembly and to measure the corresponding lattice parameters of model systems consisting of ordered aggregates of cardiolipin molecules has been investigated. An unprecedented resolution of about 0.2 nm has been achieved on suitably prepared specimens. This enables the orientational order and the positional correlations of the individual molecules in the lattice to be defined, and submolecular details, such as the acyl chains and the polar groups, to be imaged. The structural parameters derived from AFM have been compared with those obtained by transmission electron diffraction of the same specimen and found to be in excellent agreement. AFM turns out to be a powerful and probably a unique tool to reveal local phase variations in systems, such as biological membranes, that have non-homogeneous composition and organization.

Aluminum Silicates↗

Direct visualization of phosphorylase-phosphorylase kinase complexes by scanning tunneling and atomic force microscopy.

In skeletal muscle the activation of phosphorylase b is catalyzed by phosphorylase kinase. Both enzymes occur in vivo as part of a multienzyme complex. The two enzymes have been imaged by atomic force microscopy and the results compared to those previously found by scanning tunneling microscopy. Scanning tunneling microscopy and atomic force microscopy have been used to view complexes between the activating enzyme phosphorylase kinase and its substrate phosphorylase b. Changes in the size and shape of phosphorylase kinase were observed when it bound phosphorylase b.

Animals↗

Analysis of the healthy rabbit lens surface using MAC Mode atomic force microscopy.

In this investigation healthy rabbit crystalline lenses were characterized by atomic force microscopy (AFM). The lenses were cut in slices with thickness with 1mm and thus, put after cortex distinct regions of nucleus and cortex for AFM examination. AFM analysis were carried out using a PicoSPM I operating in Mac Mode. We obtained topographic images of rabbit lenses and a quantitative analysis of the width and height of fibers for nucleus and cortex regions. The longitudinal section analysis of fibers in the nucleus region indicated structures with an average width of 200nm and average height of 200nm. The intershells distance was determined as 4microm. Fiber cell cross-section dimensions, longitudinal and transverse widths, could be estimated in these regions from the AFM images. Structures with average widths as small as 1.0microm are observed in the nucleus; the intershell distance is 4.0microm. In cortical regions, hexagonal structures with average longitudinal and transverse widths of 5.0mum and 3.0mum, respectively, were identified. Three-dimensional images of tissue sections with resolution on a nanometer scale were obtained. The potential of AFM analysis for characterizing healthy and pathologic lens tissues is discussed.

Animals↗

Atomic force microscopy study of stainless-steel and nickel-titanium files.

Atomic force microscopy (AFM) is a well established and documented tool for materials investigation. The aim of this study was to evaluate the topography of conventional stainless-steel files and both hand and rotary nickel-titanium (NiTi) files by using AFM. One endodontic file of each of the following was selected: stainless-steel K-file Dentsply, stainless-steel K-file Moyco, hand NiTi K-file Nitiflex, hand NiTi Greater Taper, rotary NiTi Greater Taper, and rotary NiTi Quantec. The analyses were performed on twenty different points located along a 3-mm section starting at the tip of each file. Root mean square (RMS) parameters for contact mode imaging microscopy variations were measured. The differences between RMS values were tested by ANOVA with Fisher's protected LSD test for multiple comparisons (p < 0.05). RMS of depth profile data was used to determine any statistically significant difference in vertical amplitude. According to results, all instruments showed topographic irregularities distributed on surface. Endodontic files manufactured by the same method and alloy demonstrated significant differences, whereas no significant differences were found for instruments produced by different alloys and methods (p < 0.05). The hand NiTi Greater Taper, rotary NiTi Greater Taper, and rotary NiTi Quantec showed greater values of vertical amplitude topography compared to K-Dentsply and Nitiflex files (p < 0.05). The AFM technique proved to be a valuable research tool in the investigation of endodontic files topography.

Dental Alloys↗

Extended, relaxed, and condensed conformations of hyaluronan observed by atomic force microscopy.

The conformation of the polysaccharide hyaluronan (HA) has been investigated by tapping mode atomic force microscopy in air. HA deposited on a prehydrated mica surface favored an extended conformation, attributed to molecular combing and inhibition of subsequent chain recoil by adhesion to the structured water layer covering the surface. HA deposited on freshly cleaved mica served as a defect in a partially structured water layer, and favored relaxed, weakly helical, coiled conformations. Intramolecularly condensed forms of HA were also observed, ranging from pearl necklace forms to thick rods. The condensation is attributed to weak adhesion to the mica surface, counterion-mediated attractive electrostatic interactions between polyelectrolytes, and hydration effects. Intermolecular association of both extended and condensed forms of HA was observed to result in the formation of networks and twisted fibers, in which the chain direction is not necessarily parallel to the fiber direction. Whereas the relaxed coil and partially condensed conformations of HA are relevant to the native structure of liquid connective tissues, fully condensed rods may be more relevant for HA tethered to a cell surface or intracellular HA, and fibrous forms may be relevant for HA subjected to shear flow in tight intercellular spaces or in protein-HA complexes.

Aluminum Silicates↗

Effect of toluene extraction on Biomer surface: II. An atomic force microscopy study.

The surface characterization of Biomer and extracted Biomer has been investigated using atomic force microscopy (AFM) in order to show the influence of extraction process on the morphology and local interactions which monitor surface properties at a molecular scale. The high viscoelasticity of these polymers provided by the soft segments makes AFM imaging in contact mode quite difficult, the scanning of the tip inducing artifacts on the surface. The rate, direction, and number of scans strongly influence this friction effect. The recording of force curves has shown that the extraction and conditions of drying can modify the interaction forces present at the polymer surface. Imaging of the extracted Biomer obtained with AFM in non-contact mode has revealed inclusion nodules embedded in an amorphous phase. This may be attributed to the migration at the surface of the non-eliminated poly(aminomethacrylate) additive.

Biocompatible Materials↗

Assessing micromechanical properties of cells with atomic force microscopy: importance of the contact point.

Mechanical properties are obtainable from atomic force microscopy (AFM) indentation force-depth curves, which are calculated from relationships between tip deflection and cantilever position, i.e. deflection curves. Indentation depth is the difference between tip deflections on a rigid and a soft material for the same amount of cantilever advancement, after contact is made. Since the contact point cannot be unequivocally identified from experimental data, there is some uncertainty in estimating material properties. Using simulations, this study examines some important issues related to the influence of contact point identification on estimated material properties. Simulations for linear materials using a typical stiffness for an AFM cantilever demonstrate that certain portions of the post-contact region of deflection curves for soft and very stiff materials can be approximated by quadratic and linear functions, respectively. Based on these findings, we first develop and verify an objective, automatic method to identify the contact point for materials with linear properties. We then assess the effect of misidentifying the contact point, with and without noise. If the contact point is missed by <50 nm, material properties for small indentations are erroneous but the error decreases asymptotically beyond 200 nm of indentation and the correct estimate of material stiffness is obtained. If the contact point is missed by >100 nm, however, the true material properties cannot be estimated accurately. Noise adds to uncertainty in material properties at small indentations but the combined effect of missing the contact point and noise is dominated by the former. Even though the algorithm was developed for linear materials, it is also suitable for certain nonlinear materials making it more generally applicable.

Algorithms↗

Optical characteristics of atomic force microscopy tips for single-molecule fluorescence applications.

Knowledge of the optical properties of atomic force microscopy (AFM) tips is relevant for the combination of optical and force spectroscopy. The luminescence properties of five commercial AFM tips were characterized using a combination of multiparameter fluorescence detection (MFD) and scanning confocal techniques. These include three Si3N4 tips, one silicon tip, and one high-density carbon (HDC) tip grown on top of a silicon tip. Time-decay histograms of the signal were analyzed to determine the strength of scatter, constant background, and fluorescence in the observed signal. Intensity and anisotropy images with optical resolution down to the diffraction limit were generated. The optical signal recorded from the apex of the Si3N4 tips ranged from 0.7 to 1.9 times the count rates from single Rhodamine 110 molecules under similar illumination conditions. The signal is predominantly composed of scatter and background (>85%), plus a small fluorescence component with lifetimes between 1 and 3 ns. The intensity of the recorded signal fell with increasing distance from the apex, and by 300 nm the signals fell below single-molecule levels for all Si3N4 cantilevers. Silicon cantilevers demonstrated very low count rates relative to single-molecule measurements under all conditions, and virtually no fluorescence. The high-density carbon tips also demonstrated low count rates, but the signal contained a short lifetime fluorescence component (0.7 ns). The intensity of the signals from each of the tips was geometry dependent, demonstrating the highest intensities at the edges and corners. Likewise, the anisotropy of all tip signals was observed to be geometry dependent, with the dependence varying on a case-by-case basis. The implications for using confocal illumination instead of total internal reflection are discussed.

Anisotropy↗

Mechanical stimulation of individual stereocilia of living cochlear hair cells by atomic force microscopy.

This paper describes the investigation of elastical properties and imaging of living cochlear hair bundles of inner (IHC) and outer hair cells (OHC) on the level of individual stereocilia. A custom-made AFM-setup was used, allowing to scan the mechano-sensitive structures of the inner ear under direct control of an upright differential interference contrast (DIC) microscope with a water-immersion objective. Scanning electron microscopy (SEM) images of the identical hair bundles obtained after AFM investigation demonstrated that forces up to 1.5 nanonewton (nN) did not cause obvious damage of the surface morphology of the stereocilia. These are the first images of hair bundles of living sensory cells of the organ of Corti by AFM. They display the tips of individual stereocilia and the typical V-shape of ciliary bundles. Since line scans clearly show that slope and force interaction depend on the elastical properties of stereocilia, quantitative stiffness measurements and stimulation of single transduction channels are suggested.

Animals↗

Atomic force microscopy and cytochemistry of chromatin from marsupial spermatozoa with special reference to Sminthopsis crassicaudata.

Atomic force microscopy (AFM) of the nuclear topology of spermatozoa from two marsupial species, Smithopsis crassicaudata and Trichosurus vulpecula was investigated to determine the structural organisation of the chromatin subunits. That of the former species is of special interest as it has a peripheral nucleohistone region (C2) as well as a nuclease-resistant, nucleoprotamine core region (C1). Atomic force microscopy showed that the C2 region contained clusters of 120-160 nm nodules, whereas the C1 region exhibited smaller 50-80 nm nodules. The spermatozoa nuclei of Trichosurus, which has mainly nucleoprotamines, contained higher order chromatin structures of similar size to those from the C1 region of Sminthopsis. This study shows that nucleohistones and nucleoprotamines of marsupial sperm form distinct higher order conformations. For the second part of this work, the chromatin density and affinity for cationic stains of Sminthopsis spermatozoa were determined. Spermatozoa were observed with the transmission electron microscopy (TEM) either unstained or stained with metal salts. In the unstained specimens, the C2 nucleohistone region appeared more electron-lucent than the C1 region. When large cations such as uranyl were used, the reverse situation was observed. Therefore, the electron-dense appearance of the C2 chromatin in conventionally stained material may be due to the presence of net negative DNA charges that attract the cations used for EM staining, whereas the C1 chromatin may lack excess DNA negative charges that attract these stains and thus appears less electron-dense.

Animals↗

Actin microridges characterized by laser scanning confocal and atomic force microscopy.

We have characterized the cell surface of zebrafish stratified epithelium using a combined approach of light and atomic force microscopy under conditions which simulate wound healing. Microridges rise on average 100 nm above the surface of living epithelial cells, which correlate to bundles of cytochalasin B-insensitive actin filaments. Time-lapse microscopy revealed the bundles to form a highly dynamic network on the cell surface, in which bundles and junctions were severed and annealed on a time scale of minutes. Atomic force microscopy topographs further indicated that actin bundle junctions identified were of two types: overlaps and integrated end to side T- and Y-junctions. The surface bundle network is found only on the topmost cell layer of the explant, and never on individual locomoting cells. Possible functions of these actin bundles include cell compartmentalization of the cell surface, resistance to mechanical stress, and F-actin storage.

Actin Cytoskeleton↗

Relationship between interfacial forces measured by colloid-probe atomic force microscopy and protein resistance of poly(ethylene glycol)-grafted poly(L-lysine) adlayers on niobia surfaces.

Adsorbed layers of "comb-type" copolymers consisting of PEG chains grafted onto a poly(l-lysine) (PLL) backbone on niobium oxide substrates were studied by colloid-probe AFM in order to characterize the interfacial forces associated with coatings of varying architectures (PEG/PLL ratios and PEG chain lengths) and their relevance to protein resistance. The steric and electrostatic forces measured varied substantially with the architecture of the PLL-g-PEG copolymers. Varying the ionic strength of the buffer solutions enabled discrimination between electrostatic and steric-entropic contributions to the net interfacial force. For high PEG grafting densities the steric component was most prominent, but at low ionic strengths and high grafting densities, a repulsive electrostatic surface force was also observed; its origin was assigned to the niobia charges beneath the copolymer, as insufficient protonated amine groups in the PLL backbone were available for compensation of the oxide surface charges. For lower grafting densities and lower ionic strengths there was a substantial attractive electrostatic contribution arising from interaction of the electrical double layer arising from the protonated amine groups, with that of the silica probe surface (as under low ionic strength conditions, the electrical double layer was thicker than the PEG layer). For these PLL-g-PEG coatings the net interfacial force can thus be a markedly varying superposition of electrostatic and steric-entropic contributions, depending on various factors. The force curves correlate with protein adsorption data, demonstrating the utility of AFM colloid-probe force measurements for quantitative analysis of surface forces and how they determine interfacial interactions with proteins. Such characterization of the net interfacial forces is essential to elucidate the multiple types of interfacial forces relevant to the interactions between PLL-g-PEG coatings and proteins and to advance interpretation of protein adsorption or repellence beyond the oversimplified steric barrier model; in particular, our data demonstrate the importance of an ionic-strength-dependent minimum PEG layer thickness to screen the electrostatic interactions of charged interfaces.

Adsorption↗

Detection and localization of single molecular recognition events using atomic force microscopy.

Because of its piconewton force sensitivity and nanometer positional accuracy, the atomic force microscope (AFM) has emerged as a powerful tool for exploring the forces and the dynamics of the interaction between individual ligands and receptors, either on isolated molecules or on cellular surfaces. These studies require attaching specific biomolecules or cells on AFM tips and on solid supports and measuring the unbinding forces between the modified surfaces using AFM force spectroscopy. In this review, we describe the current methodology for molecular recognition studies using the AFM, with an emphasis on strategies available for preparing AFM tips and samples, and on procedures for detecting and localizing single molecular recognition events.

Animals↗

Atomic force microscopy and confocal laser scanning microscopy on the cytoskeleton of permeabilised and embedded cells.

We describe a technical method of cell permeabilisation and embedding to study the organisation and distribution of intracellular proteins with aid of atomic force microscopy and confocal laser scanning microscopy in identical areas. While confocal laser scanning microscopy is useful for the identification of certain proteins subsequent labelling with markers or antibodies, atomic force microscopy allows the observation of macromolecular structures in fixed and living cells. To demonstrate the field of application of this preparatory technique, cells were permeabilised, fixed, and the actin cytoskeleton was stained with phalloidin-rhodamine. Confocal laser scanning microscopy was used to show the organisation of these microfilaments, e.g. geodesic dome structures. Thereafter, cells were embedded in Durcupan water-soluble resin, followed by UV-polymerisation of resin at 4 degrees C. This procedure allowed intracellular visualisation of the cell nucleus or cytoskeletal elements by atomic force microscopy, for instance to analyse the globular organisation of actin filaments. Therefore, this method offers a great potential to combine both microscopy techniques in order to understand and interpret intracellular protein relations, for example, the biochemical and morphological interaction of the cytoskeleton.

Actins↗

Self assembly of epicuticular waxes on living plant surfaces imaged by atomic force microscopy (AFM).

The cuticle of terrestrial vascular plants and some bryophytes is covered with a complex mixture of lipids, usually called epicuticular waxes. Self-assembly processes of wax molecules lead to crystalline three-dimensional micro- and nanostructures that emerge from an underlying wax film. This paper presents the first AFM study on wax regeneration on the surfaces of living plants and the very early stages of wax crystal formation at the molecular level. Wax formation was analysed on the leaves of Euphorbia lathyris, Galanthus nivalis, and Ipheion uniflorum. Immediately after wax removal, regeneration of a wax film began, consisting of individual layers of, typically, 3-5 nm thickness. Subsequently, several different stages of crystal growth could be distinguished, and different patterns of wax regeneration as well as considerable variation in regeneration speed were found.

Euphorbia↗

Electropolishing of stainless steels in a choline chloride based ionic liquid: an electrochemical study with surface characterisation using SEM and atomic force microscopy.

We have studied the anodic dissolution (electropolishing) of various stainless steel alloys in an ionic liquid comprising a 2 : 1 stoichiometric mix of ethylene glycol (EG) and choline chloride. We have used a combination of electrochemical and spectroscopic methods together with in situ liquid probe microscopy. We discuss the role and influence of the surface oxide passivation layer, characterized here by X-ray photoelectron spectroscopy (XPS) and linear sweep voltammetry, on the polishing process. We address the question of dealloying during the polish in order to contribute to our understanding of the viability of the ionic liquid as a replacement industrial electropolishing medium; the current commercial process uses a corrosive mixture of phosphoric and sulfuric acids. Also, we present data from ex situ and in situ liquid AFM studies giving both a qualitative and quantitative insight into the nature and scale of morphological changes at the steel surface during the polishing process.

Choline↗

Electron and atomic force microscopy of membrane proteins.

Electron crystallography is becoming a powerful tool for the resolution of membrane protein structures. The past year has seen the production of a bacteriorhodopsin model at 3.5 A and the structure of aquaporin 1 approaching atomic resolution. Determination of surface topographies of 2D crystals using the atomic force microscope is similarly advancing to a level that reveals submolecular details. As the latter is operated in solution, membrane proteins can be observed at work.

Aquaporin 1↗