Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SYRINGES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Subcutaneous morphine infusion by syringe driver for terminally ill patients.

The study aimed to find whether subcutaneous morphine administration by syringe driver for terminally ill patients in a Dutch nursing home led to higher morphine doses and earlier death than routine morphine administration. The data comprised the files of all patients dying over a 2 year period in a 355-bed nursing home in Delft in the Netherlands. Thirty-eight per cent of the patients had been given morphine, 29% by continuous subcutaneous syringe driver. In comparing the patients given morphine with and without a syringe driver no differences emerged in mean age, sex, length of admission, type of ward, diagnosis, duration of morphine administration and mean dose. The data indicate that subcutaneous morphine administration by syringe driver decreases dose frequency problems and improves the control of pain and other symptoms in the last week before death. There was no evidence that administration of morphine in this way shortens survival.

Cause of Death↗

Stability of thiopental sodium and propofol in polypropylene syringes at 23 and 4 degrees C.

The stability of thiopental sodium and propofol in an admixture stored in polypropylene syringes at room temperature and under refrigeration was studied. Propofol injection 10 mg/ mL and thiopental sodium 25 mg/mL were mixed to final concentrations of 5 and 12.5 mg/mL, respectively. The admixture was put into 60-mL polypropylene syringes, and two syringes were stored at 23 degrees C and two at 4 degrees C. For solutions stored at 23 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, 240, and 264 hours, and for samples stored at 4 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, and 312 hours. Drug concentrations were determined by high-performance liquid chromatography. Thiopental sodium and propofol retained > 90% of their initial concentrations for up to 312 hours at 4 degrees C. At 23 degrees C, > 90% of the initial concentration was retained by propofol for up to 120 hours and by thiopental sodium for up to 240 hours. No visual changes or significant change in pH occurred in any sample. When mixed and stored in polypropylene syringes, propofol 5 mg/mL and thiopental sodium 12.5 mg/mL were stable for up to 312 hours at 4 degrees C and for up to 120 hours at 23 degrees C.

Anesthetics, Intravenous↗

Stability of ondansetron hydrochloride and 12 medications in plastic syringes.

The stability and compatibility of ondansetron hydrochloride with neostigmine methylsulfate, naloxone hydrochloride, midazolam hydrochloride, fentanyl citrate, alfentanil hydrochloride, atropine sulfate, morphine sulfate, meperidine hydrochloride, propofol, droperidol, metoclopramide monohydrochloride, and glycopyrrolate were studied. Ondansetron 1.33 or 1.0 mg/mL was combined with 0.9% sodium chloride injection and each of the 12 drugs in duplicate in plastic syringes (or glass for propofol). The syringes were stored at 21.8-23.4 or 4 degrees C in the dark, except for those containing propofol, which were stored at ambient temperature. Samples were removed at 0, 4, 8, and 24 hours for analysis by high-performance liquid chromatography and pH measurement; the propofol-containing samples were removed at 0, 1, 2, and 4 hours. Syringes were visually assessed for color and clarity, and particulate content was measured with a particle counter at the end of the study period. All solutions containing ondansetron retained more than 90% of their initial ondansetron concentration. Solutions containing each of the other drugs except droperidol retained more than 90% of their initial concentration of these drugs. The solutions containing droperidol retained more than 90% of their initial droperidol concentration for up to eight hours at ambient temperature but precipitated quickly at 4 degrees C. In combinations of ondansetron 1.33 or 1.0 mg/mL and 10 of 12 drugs, all drugs were stable for 24 hours in plastic syringes at 23 and 4 degrees C; ondansetron hydrochloride 1.0 mg/mL and propofol 1.0 and 5.0 mg/mL in admixtures were stable for 4 hours, and droperidol on its own and combined with ondansetron 1.0 mg/mL was stable for no more than 8 hours at ambient temperature.

Chromatography, High Pressure Liquid↗

What do pharmacists think about New York state's new nonprescription syringe sale program? Results of a survey.

Access to sterile syringes can prevent transmission of blood-borne diseases such as human immunodeficiency virus (HIV) and hepatitis B and C. We conducted survey of attitudes of pharmacists to aid in development of the Expanded Syringe Access Demonstration Program (ESAP) in New York State. ESAP is an HIV prevention initiative that authorizes nonprescription sale of hypodermic needles and syringes by registered pharmacies in New York State beginning January 1, 2001. As part of planning for program implementation, the New York State Department of Health (NYSDOH), in collaboration with the New York State Education Department, conducted mailed survey of all 4, 392 licensed pharmacies in New York State during the summer of 2000. Some surveys (171) were returned as undeliverable. Of the 4,221 eligible respondents, 874 (20.7%) completed surveys were received, of which 574 (65.7%) indicated that their pharmacy would likely participate in ESAP. An additional 11.0% were not sure. Only 139 (15.9%) indicated that they would definitely not participate; 7.4% left this question blank. There were 608 responses to questions on safe disposal practices. Of these, 315 (51.8%) respondents indicated that their pharmacy sold sharps containers, and an additional 29 made them available at no cost. Only 133 (21.9%) respondents to this question did not offer sharps containers and were not interested in doing so. In all, 54 responses indicated that they accepted used hypodermic needles and syringes for disposal. Some (170, 28%) that did not accept sharps for disposal were interested in doing so. More than half (382, 63.0%) did not wish to do so. NYSDOH considered respondent suggestions and minimized ESAP requirements. By March 31, 2001, only 3 months after ESAP became effective, more than half of all licensed pharmacies in New York State were registered for ESAP. Survey results provided useful information to NYSDOH and good indication of likelihood of registration. The high level of pharmacy participation in ESAP may be reflective of NYSDOH attention to issues raised by pharmacists, as well as the direct effects of outreach to pharmacy chains regarding ESAP.

Attitude of Health Personnel↗

Neighborhood differences in patterns of syringe access, use, and discard among injection drug users: implications for HIV outreach and prevention education.

The article presents results from the Syringe Access, Use, and Discard: Context in AIDS Risk research project comparing two neighborhoods by (1) socioeconomic and demographic characteristics; (2) patterns of syringe access, use, and discard; and (3) encounters with a local human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) outreach project targeted to injection drug users (IDUs). The results show that IDUs in more economically advantaged neighborhoods were more likely to acquire syringes from a single source (rather than multiple sources), more likely to inject alone in their own residence (rather than public injection locales), and more likely to dispose of syringes in private garbage cans rather alleys or dumpsters. These results are further associated with the likelihood of encountering street outreach workers, with IDUs in more affluent neighborhoods much less likely to have any such contacts. Based on the different patterns of access, use, and discard evident in each neighborhood, the results indicate that different and more carefully tailored local outreach and prevention strategies are urgently needed.

Adolescent↗

HIV DNA and antibodies in syringes from injecting drug users: a comparison of detection techniques.

OBJECTIVE: Direct HIV testing of individual injecting drug users is not always feasible. As an alternative, we have evaluated the sensitivity and specificity of several techniques for detecting HIV-1-specific products in used syringes. DESIGN: Polymerase chain reaction (PCR) and antibody-capture assays were compared using syringes prepared with blood from HIV-1-positive and -negative individuals. METHODS: PCR sensitivity was maximized, enabling detection of single copies of HIV-1-specific proviral DNA. The limits of detection from used syringes were determined for PCR by diluting extracts and correlated to CD4+ cell counts. Similarly, limits of detection were determined for enzyme immunoassays (EIA) and Western blot. RESULTS: All techniques were highly specific, although with PCR false-positives were detected occasionally. EIA proved more sensitive than Western blot in detecting needles containing HIV-1-infected individuals' blood. Even after prolonged storage of syringes at room temperature, EIA was equal to or better than PCR as an HIV-1 detection technique. The most sensitive method for detecting HIV-1 was the viral-based EIA when the recommended predilution step was omitted. CONCLUSIONS: EIA proved preferable to PCR because of their higher sensitivity, absence of false-positives and easier sample preparation and analysis.

Blotting, Western↗

Syringe-mediated drug-sharing (backloading): a new risk factor for HIV among injecting drug users.

BACKGROUND: In syringe-mediated drug-sharing (backloading), injecting drug users (IDU) use their syringes to mix drugs and to give measured shares to other IDU by squirting drug solution into the syringes of other IDU. Backloading has been discussed as a potential HIV risk factor, but its role as an HIV transmission route has not been established empirically. METHODS: Six hundred and sixty IDU who had injected drugs in the previous 2 years were street-recruited from Bushwick, New York City through chain referral, tested for HIV antibody and interviewed about sexual and drug-risk behaviors. RESULTS: Receiving drugs via backloading in the previous 2 years was reported by 24.5% of the subjects. These subjects had significantly higher HIV seroprevalence than those who did not receive drugs by backloading (odds ratio, 2.2; 95% confidence interval, 1.5-3.1). Backloading remained positively and significantly associated with HIV seropositivity in stepwise logistic regression, and in a series of simultaneous logistic models controlling for sociodemographic variables and for sexual and drug risk variables. CONCLUSIONS: Backloading can be a route of HIV transmission among IDU and should be incorporated into risk-factor studies and HIV transmission modeling. Many IDU who avoid other high-risk drug-injection practices may overlook the risk of backloading. HIV prevention programs should warn IDU against syringe-mediated drug-sharing and work together to develop ways to avoid it.

Adult↗

Anticoagulant effects of nonionic versus ionic contrast media in angiography syringes.

To determine whether nonionic contrast media present a clotting hazard when plastic or glass injection syringes are contaminated with aspirated blood, we evaluated two nonionic (iohexol and iopamidol) and two ionic (ioxaglate and diatrizoate) contrast agents. We used a blood:contrast media ratio of 2 mL:5 mL and ten normal donors, each studied at 10, 20, 30, and 60 minutes, a parallel study of clotting and fibrinopeptide A (FPA) generation in plastic tubes, and life table analysis to estimate more accurately donor-based early clotting probabilities. While ionic contrast media are stronger anticoagulants, both nonionic and ionic media retard clotting in plastic tubes, and clotting in plastic and glass angiography syringes in comparison to saline controls. A clotting probability of 1% for nonionic agents in plastic syringes was not reached until a time (mean +/- SD) of 21.5 +/- 3.2 minutes. This contrasts with a time of 8.7 +/- 2.5 minutes for saline control. With plastic syringes, no clotting at all was observed at 10 and 20 minutes with either class of agents. Neither class of agents hastened the generation of FPA. We found no evidence, therefore, that nonionic agents either cause clots or are procoagulant.

Angiography↗

New syringes for arterial blood sampling.

Two new syringes for arterial blood sampling were compared. Fifty syringes of each type were randomly tested in awake patients and no significant differences were found regarding time taken to collect samples, or the pain experienced by the patient. Air bubbles were found in, and blood leaked, from the Pulsator syringes significantly more often than from the Radiometer B 129 syringes (p less than 0.005).

Arteries↗

The effectiveness of syringe irrigation and ultrasonics to remove debris from simulated irregularities within prepared root canal walls.

AIM: To compare the ability of syringe irrigation and ultrasonic irrigation to remove artificially placed dentine debris from simulated canal irregularities within prepared root canals. METHODOLOGY: After canal enlargement, twelve canines were split longitudinally into two halves. On the wall of one half of each root canal a standard groove of 4 mm in length, 0.2 mm in width and 0.5 mm in depth was cut, 2-6 mm from the apex, to simulate uninstrumented canal extensions. On the wall of the other half, three standard saucer-shaped depressions of 0.3 mm in diameter and 0.5 mm in depth were cut at 2, 4 and 6 mm from the apex to simulate uninstrumented canal irregularities. Each groove and depression were filled with dentine debris mixed with 2% NaOCl to simulate a situation when dentine debris accumulates in uninstrumented canal extensions and irregularities during canal preparation. Each tooth was re-assembled by reconnecting the two halves, using wire and an impression putty material. Two per cent NaOCl was then delivered into each canal either using syringe irrigation (n = 8) or using ultrasonic irrigation (n = 8). Before and after irrigation, images of the two halves of the canal wall were taken, using a microscope and a digital camera, after which they were scanned into a PC as TIFF images. The amount of remaining dentine debris in the grooves and depressions was evaluated by using a scoring system between 0-3: the higher the score, the more the debris. The data were analysed by means of the Mann-Whitney U-test. RESULTS: Both forms of irrigation reduced the debris score significantly. The debris score was statistically significantly lower after ultrasonic irrigation than after syringe irrigation (P = 0.002 for grooves, P = 0.047 for depressions). CONCLUSION: Ultrasonic irrigation ex vivo is more effective than syringe irrigation in removing artificially created dentine debris placed in simulated uninstrumented extensions and irregularities in straight, wide root canals.

Cuspid↗

Stabilities of dobutamine, dopamine, nitroglycerin and sodium nitroprusside in disposable plastic syringes.

The solutions of dobutamine hydrochloride (5 mg/ml), dopamine hydrochloride (4 mg/ml), nitroglycerin (1 mg/ml) and sodium nitroprusside (1 mg/ml) in dextrose 5% injection were stable for 24 h when stored at 25 degrees C in 60-ml plastic syringes. For sodium nitroprusside, the syringes must be wrapped with aluminium foil (provided by the manufacturer), otherwise the loss in potency is very high (22%). There was no change in the pH values of dobutamine and dopamine solutions as well as sodium nitroprusside solutions in the prewrapped syringes. However, the pH value of nitroglycerin solutions decreased to 4.3 from 4.6 and that of sodium nitroprusside solutions in unwrapped syringes from 4.2 to 3.5; these solutions had discoloured. The chromatogram also showed new peaks from the products of decomposition. The physical appearances of the other solutions did not change.

Chromatography, High Pressure Liquid↗

Insulin syringe disposal practices of pediatric patients with insulin-dependent diabetes mellitus.

Pediatric patients with insulin-dependent diabetes mellitus were surveyed over a 5-month period to determine disposal practices of insulin syringes. Eighty-nine (79.5%) of 112 patients surveyed responded. Thirty-three percent of the responders disposed of syringes in accordance with recommendations of the local health department and the American Diabetes Association, while the remaining patients did not. Fifty-two percent of the patients rendered the syringes useless before disposal. The study revealed a need to educate and inform patients on the proper procedures that should be followed when disposing of syringes in the home.

Adolescent↗

Drugs given by a syringe driver: a prospective multicentre survey of palliative care services in the UK.

The use of a syringe driver to administer drugs by continuous subcutaneous infusion is common practice in the UK. Over time, drug combinations used in a syringe driver are likely to change and the aim of this survey was to obtain a more recent snapshot of practice. On four separate days, at two-week intervals, a questionnaire was completed for every syringe driver in use by 15 palliative care services. Of 336 syringe drivers, the majority contained either two or three drugs, but one-fifth contained only one drug. The median (range) volume of the infusions was 15 (9.5-48) mL, and duration of infusion was generally 24 hours. Only one combination was reported as visually incompatible, and there were 13 site reactions (4% of total). Laboratory physical and chemical compatibility data are available for less than half of the most frequently used combinations.

Drug Therapy↗

Stability of ondansetron stored in polypropylene syringes.

OBJECTIVE: To evaluate the stability of ondansetron hydrochloride undiluted and mixed in dextrose 5% injection or NaCl 0.9% injection during storage in polypropylene syringes when frozen, refrigerated, or at room temperature. DESIGN: Batch quantities of ondansetron 0.25, 0.5, 1.0, and 2.0 mg/mL were prepared and individual doses of 10.5 mg were drawn into polypropylene syringes that were stored at -20 degrees C for up to 3 months, at 4 degrees C for up to two weeks, or at 22-25 degrees C for two days, and various combinations of these conditions. At defined sampling times aliquots were withdrawn from syringes, the solution visually inspected, pH measured, and ondansetron concentration determined by HPLC. Drug loss of > or = 10 percent of the original content of the solution was considered clinically significant. RESULTS: The ondansetron concentration in each solution, regardless of storage conditions, remained above 90 percent of the original concentration at each observation time (range 92-107 percent). No changes in color or clarity of any of the solutions were observed, and only slight fluctuations in pH (< or = 0.05) were noted. CONCLUSIONS: Ondansetron 2 mg/mL undiluted, or at concentrations of 0.25, 0.5, or 1 mg/mL, mixed in dextrose 5% injection or NaCl 0.9% injection was determined to be stable when stored in polypropylene syringes for each storage condition at all time points studied, including the maximum for each: three months at -20 degrees C, followed by 14 days at 4 degrees C, and by 48 hours at 22-25 degrees C.

Drug Stability↗

Use of a screw-syringe injector for cement delivery during kyphoplasty: technical report.

OBJECTIVE: Percutaneous kyphoplasty is postulated to have several advantages over percutaneous vertebroplasty for the treatment of vertebral compression fractures and is gaining increased popularity. However, cement delivery with the KyphX kit (Kyphon, Inc., Santa Clara, CA), the only commercially available device for percutaneous kyphoplasty, is relatively problematic. This kit uses a series of "bone filler device" (BFD) tubes. Each BFD must be loaded manually with cement, which is then injected into the kyphoplasty cavity by manually depressing an inner stylet. The high profile of the BFD cannulas and their stylets requires frequent repositioning of the image intensifier tube and table. Because each accommodates only a small volume, the BFDs must be exchanged frequently. This delivery method also places the operator's hands directly in the field of radiation. We sought to overcome these limitations. METHODS: Dissatisfied with the shortcomings of the BFDs, we substituted the EZflow screw-syringe injector (Parallax Medical, Mountain View, CA) we use to deliver cement during conventional percutaneous vertebroplasty. This amalgam of the KyphX kit and the screw-syringe injector has been used for kyphoplasty treatment of 26 thoracolumbar compression fractures in 17 patients. RESULTS: The screw-syringe injector allows controlled volumetric delivery of large boluses of high-viscosity cement without having to refill the reservoir. It minimizes radiation exposure and does not require repositioning of the x-ray tubes. It may theoretically allow decompression should cement extrusion occur. Also, it delivers cement to the interstices of bony trabeculae outside the kyphoplasty cavity, thus combining the mechanical benefits of percutaneous kyphoplasty and percutaneous vertebroplasty. CONCLUSION: The use of a screw-syringe injector has several merits over the customary means of cement delivery during kyphoplasty.

Bone Cements↗

Estimating the prevalence of syringe-borne and sexually transmitted diseases among injection drug users in St Petersburg, Russia.

Injection drug users (IDUs) are the vanguard of the human immunodeficiency virus (HIV) epidemic in Russia. We sought a non-invasive method to estimate a point prevalence of HIV, hepatitis B virus (HBV), hepatitis C virus (HCV), syphilis and risk behaviours in IDUs attending the syringe exchange programme (SEP) in St Petersburg, Russia. One hundred and one IDUs returning syringes to the St Petersburg SEP were invited to complete a questionnaire requesting demographic, knowledge, and behavioural information, and to provide their syringes for antibody testing. The median age of IDUs was 23 years. Syringe prevalences were: 10.9% for HIV, 78.2% for HCV, 15.8% for HBV, and 6.9% for syphilis. All respondents recognized drug-related risk factors for getting AIDS. Only two-thirds of subjects recognized condoms to prevent sexually transmitted infections and half knew that oil-based lubricants are not appropriate for condoms. The IDU population studied was young and requires additional interventions to encourage safer sexual behaviours.

Adolescent↗

The Tacoma Syringe Exchange.

For over a year, the Tacoma Syringe Exchange has been operating in spite of existing drug paraphernalia laws. One hundred fifty-four subjects have been interviewed regarding drug injection practices for the month prior to first use of the exchange and for the most recent month since using the exchange. Statistically significant reductions in mean frequency of obtaining used syringes, and in mean rate of passing on used syringes, have been reported. Mean number of times bleach was used to disinfect contaminated syringes has risen. The exchange continues to attract mainly men, median age 35, with a long history of injection. No differences have been observed in mean number of injections per month. In order to increase utilization, new sites are planned, but expansion has been hampered by a series of legal problems. Since the exchange draws many difficult to reach individuals, it is an important location for STD screening and drug treatment recruitment. Documentation of participation patterns and barriers to exchange use, and effects upon HIV serological status are recommended.

Acquired Immunodeficiency Syndrome↗

The syringe shield rule: model for practitioner-initiated regulatory reform.

OBJECTIVE: To implement a performance-based method for maintaining radiation exposures to extremities as low as reasonably achievable while handling syringes containing radioactive materials. SETTING: University hospital nuclear medicine clinic. PRACTICE DESCRIPTION: Nuclear pharmacy and nuclear medicine. PRACTICE INNOVATION: The author petitioned the Iowa Department of Public Health to revise its prescriptive syringe shield rule to allow for the development of a performance-based method while handling syringes containing radioactive material. MAIN OUTCOME MEASURES: Following enactment of the revised rule, a new performance-based policy and guidelines for the use of syringe shields were developed and implemented. Extremity exposures for nuclear medicine personnel were monitored in the nuclear medicine clinic and evaluated for 6-month periods immediately before and after implementation of the new policy and guidelines. RESULTS: The Iowa Department of Public Health responded favorably to the author's petition and revised its rule to allow performance-based methods. Implementation of the performance-based method did not significantly affect extremity exposures. CONCLUSION: Practitioner-initiated regulatory reform for revision of a prescriptive rule to a performance-based rule can be feasible and practicable.

Extremities↗