Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Failure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Surgical considerations for endosseous implants in the craniofacial region: a 3-year report.

From 1987 to 1990, 28 patients were treated with titanium implants (Brånemark flange fixtures) in the craniofacial area for the support of craniofacial prosthesis or anchorage of bone-conduction hearing aids in the Orofacial Implant Center at the University of California, Los Angeles (UCLA). A total of 88 implants were placed, of which 22 were placed in previously irradiated areas. Twenty-three of the implants were placed in the orbital area, 37 in the mastoid area, 20 in the nasal area, and eight in various other craniofacial regions. Seven implants were lost in four different patients. The proper location and positioning of implants in specific areas of the craniofacial regions, as well as soft-tissue complications and management, are discussed.

Adolescent↗

The Ilizarov method for failed knee arthrodesis following septic TKR.

Knee arthrodesis is a well-recognized salvage procedure in patients with infected total knee arthroplasties. If a fusion is achieved, it offers the opportunity for a stable lower limb and eradication of infection, but at the expense of knee motion. However, knee arthrodesis in this setting may be difficult to achieve because of poor bone stock, persistent infection, soft tissue compromise, and often the poor general health of the patient. We report two cases of failed knee arthrodesis following periprosthetic infection where a fusion was successfully achieved with open debridement and a hybrid advanced Ilizarov fixator.

Aged↗

Clinical outcome and patient satisfaction in aseptic and septic revision total knee arthroplasty.

This study compares clinical outcome and patient satisfaction in 33 aseptic and 15 septic revision total knee arthroplasties across a 30-130-month follow-up. Aseptic revisions included only knees in which the femoral, tibial and patellar components had been exchanged, and excluded knees in which only isolated patellar components had been revised or only the tibial insert exchanged. Septic revisions included only knees in which there had been successful revision for chronic infection without recurrence of infection for at least 2 years from the index revision. The evaluation included pain scores, knee scores, functional scores, SF-12 functional surveys and radiographs of the knee. The results for the aseptic group were excellent in 26 (78.8%), good in 3 (9.0%), fair in 2 (6.1%) and poor in 2 (6.1%); those for the septic group were excellent in 5 (33.3%), good in 7 (46.7%), fair in 2 (13.3%) and poor in 1 (6.7%). The overall results of septic revision were less satisfactory than for aseptic revision. Aseptic revisions achieved significantly better knee scores and ranges of motion than septic revisions, but their pain and functional scores were similar. Despite the difference in knee scores, 85% of the patients from both groups were equally satisfied with the results of treatment. There was no discernible radiographic difference between the two groups, including radiolucency.

Aged↗

Randomised, prospective evaluation of a new pericardial heart valve: outcome after seven years.

Between 2 February 1987 and 20 March 1990, 170 patients were randomly allocated to receive a new pericardial heart valve (the Bioflo) or the Carpentier-Edwards supra-annular porcine bioprosthesis. Eighty-five patients (mean age 61 years, range 38-77) received 93 Bioflo valves, 46 having aortic valve replacement (AVR), 31 mitral valve replacement (MVR) and 8 aortic and mitral valve replacement (A+MVR); 85 patients (mean age 62.1 years, range 41-77) received 99 Carpentier-Edwards porcine valves (48 AVR, 23 MVR and 14 A+MVR). Cumulative follow-up totals 926 patient-years (mean 5.45 +/- 1.93, median 6.03, maximum 7.47 years). The overall operative mortality rate for the Bioflo group was 2.4%, and 5.9% for the Carpentier-Edwards group. At 7 years, there was no statistically significant difference in survival or in any prosthesis-related complication between the pericardial and porcine valve recipients overall, or when the data were analysed according to valve implant position. The actuarial survival rate at 7 years for the Bioflo group was 80.1 +/- 5.1% and 72.3 +/- 5.9% for the Carpentier-Edwards group. Freedom from structural valve deterioration (SVD) at 7 years for Bioflo patients was 98.5 +/- 1.5% and for Carpentier-Edwards patients 91.2 +/- 4.1%. No patient in the Bioflo group has required reoperation for SVD. The randomised prospective trial has proven practical and effective and has shown the pericardial valve to perform at least as well as the porcine valve up to 7 years when all of the standard outcome measures of valve performance are assessed.

Actuarial Analysis↗

Video-assisted tricuspid valve surgery: a new surgical option in endocarditis on pacemaker.

A patient presenting with a pacemaker lead infection and tricuspid regurgitation underwent a minimally invasive video-assisted tricuspid valve replacement. The valve was approached through a right anterior mini thoracotomy. Under thoracoscopic vision and peripheral cardiopulmonary bypass, a catheter was placed on the ascending aorta for antegrade cardioplegia delivery. A transthoracic aortic cross-clamp was introduced through the third right intercostal space. Tricuspid valve replacement added to the pacemaker leads ablation was exclusively performed under thoracoscopic vision, providing an excellent video-image in this reduced operative field. After 22 months of follow up, the patient is asymptomatic, the echocardiography showing a normally functioning valve.

Cardiopulmonary Bypass↗

Lower intestinal bleeding due to aorto-enteric fistula.

The case is described of a man who complained of intermittent fever and fatigue. After three digestive endoscopies and computed tomography, a 99m technetium-HM-PAO-labelled white cell scan was usefully employed to establish diagnosis. Anaerobic aortic Graft infection and anaemia due to lower intermittent occult intestinal bleeding were found. The intestinal bleeding was caused by secondary aorto-jejunal fistula. This condition is rare, but should be suspected whenever a patient with aortic prosthesis presents with occult digestive bleeding and unexplained fever.

Aged↗

Profound deafness treated by the Ineraid multichannel intracochlear implant.

Twelve deaf adults and two deaf children were treated with the Ineraid (formerly Symbion) four channel intracochlear implant between September 1989 and October 1991 at Addenbrooke's Hospital in Cambridge. All were post-lingually totally deaf and had found themselves beyond the reach of hearing aids. The effect of the implant upon the patients ability to lip-read was tested with the speech tracking test, BKB sentences (comparable to CID sentences) and Boothroyd word lists (comparable to NU6 word lists). All patients showed an improvement in their ability to understand speech with the help of the implant. Discrimination of speech without lip-reading was tested with Boothroyd word lists and BKB sentences, eight patients (57 per cent) demonstrated some 'open set' speech discrimination. The acceptability of the carbon percutaneous pedestal is discussed from the patient's, audiologist's and surgeon's points of view.

Adolescent↗

Analysis of failure of voice production by a sound-producing voice prosthesis.

OBJECTIVE: To analyse the cause of failing voice production by a sound-producing voice prosthesis (SPVP). METHODS: The functioning of a prototype SPVP is described in a female laryngectomee before and after its sound-producing mechanism was impeded by tracheal phlegm. This assessment included: perceptual voice evaluation of read-aloud prose by an expert listener; inspection of the malfunctioning SPVP; and aero-acoustical in vivo registrations using a computer-based data acquisition system. RESULTS: Sound-producing voice prosthesis speech is higher pitched, stronger, contains less aperiodic noise and requires a lower airflow rate than the patient's regular tracheoesophageal (TE) shunt speech. Tracheal phlegm caused malfunction of the vibrating silicone lip of the SPVP by causing it to stick to its stainless steel container in an opened position, thereby reducing the SPVP to no more than a regular TE shunt valve from a functional point of view. Tracheal phonatory pressure and dynamic vocal intensity range were not affected by the functional status of the SPVP. CONCLUSIONS: To exploit the advantages an SPVP could offer female laryngectomees with an atonic or severely hypotonic pharyngoesophageal segment, the sound-producing mechanism of the SPVP needs to be less vulnerable to tracheal phlegm.

Aged, 80 and over↗

Antimicrobial treatment of peri-implant infections.

The purpose of this study was to investigate the possibility of antimicrobial treatment of peri-implant infections associated with a periodontitis-like subgingival microbiota. Nine partially or fully edentulous patients with titanium hollow cylinder implants were selected which showed loss of bone and probing depths > or = 5 mm on one or several implants after at least 6 months following installation. They also yielded subgingival microbial samples with > or = 10(6) CFU/ml, including > or = 20% gram-negative anaerobic bacteria. The treatment included mechanical cleaning, irrigation of all peri-implant pockets > 3 mm with 0.5% chlorhexidine and systemic antimicrobial therapy (1000 mg ornidazole for 10 consecutive days). After therapy, bleeding scores decreased immediately and, over a one-year observation period, remained significantly lower than before treatment. A significant gradual reduction in mean probing depths was detected over this one-year period; only one case showed no improvement of local probing depth. Microbiological parameters indicated an instantaneous quantitative and qualitative change following treatment. Subsequently, several of these parameters tended to shift back towards pretreatment values. In the second half of the observation period, however, this tendency was reversed, and levels significantly different from baseline were eventually established. This study demonstrated that treatment aiming at reducing the subgingival bacterial mass and suppressing the anaerobic segment had a beneficial effect in patients suffering from peri-implantitis.

Bacteria, Anaerobic↗

Low sensitivity of histology to predict the presence of microorganisms in suspected aseptic loosening of a joint prosthesis.

Intraoperative histology has a high specificity and sensitivity when a septic prosthesis loosening is suspected. However, its usefulness to predict the presence of microorganisms when aseptic loosening is suspected is not well defined. Intraoperative histology and cultures from periprosthetic tissue of 61 revision arthroplasties performed owing to suspected aseptic loosening were retrospectively reviewed. Frozen sections were evaluated following Mirra's criteria (adapted by Feldman). Culture was considered positive when the same microorganism was isolated in at least two samples. The cultures were positive in 12 cases and coagulase-negative staphylococci were the most common microorganisms (11 cases). In six out of 12 cases (50%), the histology revealed more than five polymorphonuclear leukocytes per high-power field. The sensitivity, specificity, positive and negative predictive value of histology to detect the presence of microorganisms was 50, 81, 40 and 86%, respectively. In conclusion, intraoperative histology using Mirra's criteria had a low sensitivity to predict the presence of microorganisms in samples from suspected aseptic prosthetic loosening.

Aged↗

Penile prostheses for the management of the neuropathic bladder and sexual dysfunction in spinal cord injury patients: long term follow up.

During the last 10 years, 90 penile prostheses were implanted in 82 patients with spinal cord injury. Surgery was done 1 month to 25 years (average 4.8 years) after the injury. The follow up period ranged from 1 to 10 years (average 4 years). A prosthesis was implanted for urinary management in 51 patients (62%), for sexual dysfunction in 10 patients (12%) and for both purposes in 21 patients (26%). Ninety-three per cent of the patients who used the implant for urinary management and 64% of the patients who used it for sexual dysfunction were satisfactory. We experienced three extrusions and nine surgical removals due to pain, difficulty of catheterisation and infection (the complication rate was 13.3%). Generally speaking, a penile prosthesis improves the quality of life of patients with spinal cord injury significantly; however, extrusion and infection are still significant problems.

Adolescent↗

Transesophageal color Doppler three-dimensional echocardiographic detection of prosthetic aortic valve dehiscence: correlation with surgical findings.

Three-dimensional echocardiography is being used with increasing frequency to evaluate cardiac function and structure. We present two cases of prosthetic aortic valve endocarditis where three-dimensional transesophageal echocardiography correlated with the intraoperative surgical findings of prosthetic dehiscence and communication with an abscess cavity. When compared with two-dimensional transesophageal echocardiography, three-dimensional echocardiography was more accurate in defining the exact site of dehiscence and communication with an abscess cavity. The echocardiographic images were oriented as a clockface watch to conform to the surgeon's visualization of the aortic root as viewed from the right side of the patient.

Abscess↗

The swing procedure for pelvic ring reconstruction following tumour excision.

AIM: High grade periacetabular osteosarcomas extending to the sacro-iliac region present a difficult management problem. We describe our experience of the swing procedure as a method of limb salvage. METHOD: The procedure was performed on three patients with stage II B osteosarcoma. RESULTS: Functional outcome was poor in all three with a mean Musculoskeletal Tumor Society score of 29% (27-30) at last review. All three developed local recurrence and one developed pulmonary metastases. The mean disease free interval post-operatively was 4.7 months (4-6) and they died of their disease at a mean of 10 months (5-16). CONCLUSIONS: This form of limb salvage is technically demanding and carries a high morbidity. Functional outcome is poor and the prognosis for this group of patients is not improved by surgery. Alternative treatment options are discussed.

Adolescent↗

Prosthetic vascular infection complicated or not by aortoenteric fistula: comparison of treatment with and without cryopreserved allograft (homograft).

OBJECTIVES: in patients with vascular prosthesis infection, to compare surgical outcome and long-term results of cryopreserved allograft implantations to conventional surgery. DESIGN: retrospective study. MATERIAL AND METHODS: two asynchronous series of 44 [series I: 1980-1994; 8 patients with aortoenteric fistula (AEF)] and 22 (series II: 1994-1997; 4 patients with AEF) patients were treated for prosthesis infection. All patients had prosthesis excision. In series I, there were 4 in situ reparations, 26 extra-anatomic bypass, 13 excision only, and one death at laparotomy. In series II, in situ cryopreserved allografts were implanted in all patients. RESULTS: operative mortality was 16% in series I and 13.6% in series II. For AEF patients, mortality was 37% in series I and 50% in series II. Among hospital survivors, infection-related late mortality was 13.5% in series I and 5% in series II. For AEF patients, late mortality was 20% in series I and 50% in series II. Incidence of reoperations was 54% in series I and 10.5% in series II (p<0.01). Hospital stay was 47.2+/-26.4 days in series I and 16.6+/-11.5 days in series II (p<0.001). CONCLUSIONS: compared to conventional treatment, incidence of reoperations and length of hospital stay are significantly decreased after cryopreserved allograft implantation. However, closure of aortic stump and extra-anatomic bypass gives better results for patients with AEF.

Aged↗