Intrusion and reversal of a free-standing natural tooth bounded by two implant-supported prostheses: a clinical report.

Although intrusion of natural tooth abutments in tooth-implant connected fixed prostheses has been reported, it can also occur to a free-standing natural tooth bounded by implant prostheses. For the patient described in this article, intrusion was noted with a natural tooth bounded by 2 implant-supported prostheses 5 months after insertion of the prostheses. The intrusion was reversed completely after 5 months with appropriate management. The course of treatment and possible mechanisms of intrusion are provided.

Bicuspid↗

Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses: comparison at long-term follow-up.

BACKGROUND: Small-sized prostheses for aortic valve replacement may result in residual left ventricular outflow tract obstruction. Aim of the study was to verify whether implantation of 19-mm versus 21-mm St. Jude Medical standard prostheses (St. Jude Medical, Inc, St. Paul, MN) influences long-term clinical outcome. METHODS: Two hundred twenty-nine patients who underwent aortic valve replacement with 19 mm (group 1, 53 patients) or 21-mm St. Jude Medical standard prostheses (group 2, 176 patients) were included in the study. Mean follow-up of current survivors was 10+/-4 years. RESULTS: Operative mortality was 7.5% in group 1 and 8.5% in group 2. At discharge, an important patient-prosthesis mismatch (effective orifice area index < or = 0.60 cm2/m2) was present in 18% of group 1 versus 5% in group 2 (p = 0.004). Among patients with body surface area less than 1.70 m2, such mismatch was present in 15% of group 1 versus 2% of group 2 (p = 0.008). At last follow-up New York Heart Association (NYHA) functional class (p < 0.001), left ventricular mass reduction (p = 0.02), mean (p = 0.002) and peak transprosthetic gradients (p < 0.001), and effective orifice area index (p = 0.005) were significantly better in group 2. Freedom from sudden death (92%+/-5% vs 99%+/-1%, p = 0.01), valve-related death (84%+/-6% vs 90%+/-5%, p = 0.02), and cardiac events (56%+/-13% vs 86%+/-4%, p = 0.008), were significantly lower in group 1. Effective orifice area index was an independent predictor of late cardiac events. CONCLUSIONS: Although long-term results after aortic valve replacement with small-sized St. Jude Medical standard prostheses are satisfactory, 19-mm valve recipients show a high prevalence of important patient-prosthesis mismatch with less evident functional improvement and higher rate of cardiac events, suggesting a very cautious use of this prosthesis.

Aged↗

Treatment outcomes of fixed or removable implant-supported prostheses in the edentulous maxilla. Part II: clinical findings.

STATEMENT OF PROBLEM: There is a widespread belief that maxillary overdenture prostheses are associated with a higher frequency of complications and require more maintenance than fixed implant prostheses. PURPOSE: This prospective clinical study compared the treatment outcomes of fixed and removable implant-supported restorations in the edentulous maxilla with the main emphasis on the clinician's point of view. MATERIAL AND METHODS: Ten patients were treated with fixed screw-retained implant prostheses (group 1), and 10 patients were treated with removable implant-supported overdentures (group 2) in the edentulous maxilla. Recall was scheduled at 6-month intervals to investigate the prosthodontic treatment outcomes, including implant survival, prosthesis time until retreatment, and maintenance issues. Clinical parameters gingival index (GI), plaque index (PI), the clinical attachment level, and radiographic marginal bone levels measured, along with any biologic and mechanical complications were recorded. RESULTS: Patients were followed over a mean period of 39 months (SD=7; group 1) and 27 months (SD=10; group 2) after implant placement. Cumulative implant survival was 97.6% for group 1 and 94.4% for group 2 after an 18-month observation period. The mean time until retreatment after prostheses insertion was 23.4 months for group 1 and 19.8 months for group 2 (n.s.). In both groups, the increase over time in the radiographically investigated bone level was found to be significant. The indices given for the mucosal health and oral hygiene status (GI and PI) were highly correlated in both groups at each recall appointment, but no significant differences were found between groups 1 and 2. CONCLUSION: In groups 1 and 2, comparable prosthodontic treatment outcomes were achieved. The majority of mechanical complications could be managed chairside during recall visits and did not require additional appointments, so that the time and costs involved in providing maintenance were kept down.

Alveolar Process↗

Clinical complications with implants and implant prostheses.

The purpose of this article is to identify the types of complications that have been reported in conjunction with endosseous root form implants and associated implant prostheses. A Medline and an extensive hand search were performed on English-language publications beginning in 1981. The searches focused on publications that contained clinical data regarding success/failure/complications. The complications were divided into the following 6 categories: surgical, implant loss, bone loss, peri-implant soft tissue, mechanical, and esthetic/phonetic. The raw data were combined from multiple studies and means calculated to identify trends noted in the incidences of complications. The most common implant complications (those with a greater than a 15% incidence) were loosening of the overdenture retentive mechanism (33%), implant loss in irradiated maxillae (25%), hemorrhage-related complications (24%), resin veneer fracture with fixed partial dentures (22%), implant loss with maxillary overdentures (21%), overdentures needing to be relined (19%), implant loss in type IV bone (16%), and overdenture clip/attachment fracture (16%). It was not possible to calculate an overall complications incidence for implant prostheses because there were not multiple clinical studies that simultaneously evaluated all or most of the categories of complications. Although the implant data had to be obtained from different studies, they do indicate a trend toward a greater incidence of complications with implant prostheses than single crowns, fixed partial dentures, all-ceramic crowns, resin-bonded prostheses, and posts and cores.

Alveolar Bone Loss↗

The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit.

Implant failure as a consequence of prosthetic loading following clinical determination of successful stage I healing is poorly understood. A basic premise of accepted prosthetic protocol is passive connection of multiunit prostheses to the implant support. To better understand mechanical factors related to implant failure, this basic passivity premise was experimentally tested prior to study of functional loading research. The purpose of this preliminary study was to measure the bone response around implants placed in the mandible of baboons that supported prostheses exhibiting two levels of fit and not loaded occlusally. Screw-retained prostheses that exhibited a mean linear distortion of 38 microns and 345 microns made up the fit and misfit groups respectively. The results failed to distinguish a difference in bone response between the two levels of prosthetic fit. Although the finding can be argued as a sample size limitation, the data strongly suggest an opposite response than is clinically expected and, consequently, does not warrant the use of additional animals in this initial study. Because the design of this study does not mimic the clinical application of misfitting prostheses (where dynamic functional loads are superimposed with misfit loads), it cannot be inferred that, in clinical application, fit does not alter the osseointegrated interface. Ongoing investigation of failure due to nonpassive connections under dynamic loading conditions of mastication will help clarify the clinical significance of passivity.

Analysis of Variance↗

Influence of the size of aortic valve prostheses on hemodynamics and change in left ventricular mass: implications for the surgical management of aortic stenosis.

UNLABELLED: Discussion of aortic valve replacement has primarily concerned the choice between tissue and mechanical prostheses. Less emphasis has been placed on prosthesis size. Despite technical advances increasing prosthesis orifice area, small valves implanted in the unenlarged aortic root may not be significantly less obstructive than the stenotic native valves they replace. METHODS: In this work we studied 52 patients (31 women, 21 men; mean age 59.2 years) in whom valve prostheses sized 19, 21, 23, or 25 mm (30 bioprostheses and 22 tilting disc valves) had been implanted to replace stenotic aortic valves. Most patients with 19 or 21 mm prostheses were women. Doppler and conventional echocardiographic studies were performed in the 10 days preceding the operation and between 10 and 40 months (mean 18 months) after the operation. The patients receiving larger valve sizes had significantly larger body surface areas than those receiving smaller valve sizes (mainly women). RESULTS: No significant differences were observed between preoperative and postoperative diameters or left ventricular systolic function parameters, but left ventricular mass and mass index decreased in all four groups (albeit nonsignificantly in the 19 mm group, and with less statistical significance in the 21 mm group than in the 23 and 25 mm groups). Postoperative peak and mean transvalvular pressure drops were significantly greater in the 19 mm group than in the other groups, and the 21 mm group had significantly greater transvalvular pressure drops than the 25 mm group. Postoperative effective valve area was significantly smaller in the 19 mm group than in the 21 mm group, and significantly smaller in the 21 mm group than in the 23 and 25 mm groups. CONCLUSION: We conclude that despite undeniable recent improvements in the design of artificial heart valves, 19 mm aortic prostheses continue to create significant obstruction of the left ventricular outflow tract and, possibly as a consequence of this, fail to bring about significant reduction in left ventricular hypertrophy.

Aged↗

Comparison of hemodynamic performances of St. Jude Medical and CarboMedics 21 mm aortic prostheses by means of dobutamine stress echocardiography.

Dobutamine stress Doppler echocardiography was used to compare the hemodynamic performance of two small aortic bileaflet prostheses. Nineteen patients (14 female, mean age 64 years) who had undergone aortic valve replacement with 21 mm bileaflet valve prostheses (St. Jude Medical valve, n = 9, or CarboMedics valve, n = 10) were studied. Dobutamine infusion was started at a rate of 5 micrograms.kg-1.min-1 and increased to 10 and 20 micrograms.kg-1.min-1 at 15-minute intervals. Under maximum stress, heart rate and cardiac output increased by 70% and 120%, respectively, and mean arterial blood pressure decreased by 9%. Pulsed-wave and continuous-wave Doppler studies were performed at rest and at the end of each stage. Velocity ratio, effective orifice area, performance index, and discharge coefficient of the valve were calculated, and peak and mean velocities and pressure drops across the prostheses were measured. Dobutamine infusion produced similar increases in cardiac output in all patients. Effective orifice areas, discharge coefficients, and performance indexes were comparable for the two valve groups both at rest and maximum stress. Transvalvular velocities and pressure drops were also similar in the two valve groups. Transvalvular pressure drops were also comparable in patients with large body surface area. Dobutamine stress echocardiography is useful in the evaluation of the hemodynamic performance of prosthetic heart valves. St. Jude Medical and CarboMedics 21 mm prostheses have equally favorable hemodynamic performances in most patients under conditions of high cardiac output.

Aged↗

[Mechanisms of damage to metal-on-polyethylene articulating surfaces of total hip prostheses: influence of intra-articulate migration of metallic debris].

PURPOSE OF THE STUDY: The objective of this work was to identify the mechanisms leading to deterioration of the polyethylene acetabular surface in total hip prostheses. MATERIAL AND METHODS: We conducted an in vivo analysis of damage caused to articulating surfaces of metal-on-polyethylene total hip prostheses. This analysis was performed on three of the 45 explants of Harris-Galante prostheses available to use from our series of 1480 implantations performed between 1985 and 1996. These three pieces were selected because large-sized fibers of metallic debris were identified on the polyethylene surface and because the explants had been performed for reasons other than loosening in aseptic patients. Macroscopic examination was combined with scan electron microscopy to analyze morphological changes. RESULTS: We found that identical damage could be observed on the polyethylene explants despite the different sizes of the metallic heads and different metal-on-polyethylene combinations. Our analysis confirmed the deleterious effect of metallic foreign bodies trapped in contact with the articulate surfaces. These foreign bodies resulted in one case from rupture of a multifilament wire used for the trochanteric fixation and in two cases from the surfacing of the non-cemented Harris-Galante cups. The microscopic analysis demonstrated several successive localizations of the foreign bodies on the polyethylene surface before becoming deeply encrusted in the polyethylene where they deteriorated the femoral head surface (rough) and wore the polyethylene surface (abrasion). When the fibers came from the surfacing of the Harris-Galante cups, the metallic debris remained unrecognized during the revision procedure and were only identified later during the systematic examination of prosthetic explants. DISCUSSION AND CONCLUSION: These findings emphasize the importance of quality surface treatments for non-cemented prostheses and argue in favor of particular precautions during operative manipulation of these components. A systematic analysis of the prosthetic explants is advisable, particularly for components explanted because of wear or unexplained osteolysis. Use of multifilament trochanteric wires should be avoided because rupture raises the risk of intra-articulate migration of metallic debris. If the prosthesis involves a polyethylene acetabular surface, ceramic heads should be preferred to improve resistance to abrasion, particularly to limit the deleterious effect of a third body.

Adult↗

Endurance testing of hip prostheses: a comparison between the load fixed in ISO 7206 standard and the physiological loads.

BACKGROUND: Pre-clinical endurance validation of innovative hip prostheses femoral components are carried out following the ISO 7206 standard. The in vitro fatigue test must simulate accurately the physiological load to correctly define the section of the stem. OBJECTIVE: This study investigates if the loads defined in the ISO 7206 standard simulate correctly the physiological load that occur in vivo. DESIGN: Simulation of the damage induced by in vitro test and in vivo loads is performed. Different designs of the stem are examined. Materials with different fatigue limit are considered. For the in vivo loads, different body weights are modelled. METHODS: The minimal stem dimensions required to stand 20years of patient use and to pass the fatigue test are calculated based on linear damage accumulation. RESULTS: The results show that the ISO load simulates reasonably well the physiological load that is likely to occur in active patients with a low or normal body weight. Conversely, the ISO test underestimates the physiological load that heavy and active patients are likely to apply to the implant. CONCLUSIONS: Different minimum requirements for endurance strength should be fixed for hip prostheses designed for patients of different weight. This solution would reduce the risk of undersizing or oversizing the stem. RELEVANCE: The introduction of a classification of the hip prostheses, fixing different minimum requirements for endurance strength, will lead to correctly size stems made of new materials or coated using new surface treatments, reducing the risk of implant failure of innovative prostheses.

Hip Prosthesis↗

Qualitative evaluation of elderly home residents' fixed and removable prostheses in relation to the ADL index.

UNLABELLED: Functional diversity and biopsychosocial state is a significant issue, which greatly influences elderly oral health and state of fixed and removable prostheses. OBJECTIVES: The goal of the investigation was to evaluate the quality of fixed and removable prostheses in a group of elderly home residents in relation to the ADL index. METHODS: The group consisted of 175 institutionalised elderly, mean age 76.8 years. Special care need was assessed on ADL scale. To evaluate the quality and need for replacement of fixed and removable prostheses Karlsson's and modified Nevalainen et al. indices were used. RESULTS: Spearman's correlation analysis showed significant correlation of ADL index scores and both Karlsson's index values (rho=-0.468, p<0.01) as well as for modified Nevalainen's indices (rho=-0.572, p<0.01). Lower ADL score was correlated with poorer oral hygiene and condition of fixed or removable dentures. It was determined that 87% of the examined patients were in objective need of fixed, removable or combined prosthodontic treatment. CONCLUSIONS: The study showed that lower ADL index scores of functionally dependent elderly patients correlate with poorer condition of fixed and removable prostheses and greater need of fixed, removable or combined prosthodontic treatment.

Activities of Daily Living↗

[Biomechanic considerations in wrist prostheses].

At the present time, in disorders of the wrist, avulsion of the first carpal row is the most commonly used technique as a last resort. However, there are many wrist prostheses, which are reviewed here. Roughly, they belong to two families: the three axis prostheses (spherical) that cannot transmit to the hand the pronation supination torque, because of their geometrical characteristics, and the two axis prostheses (universal joint) that are able to transmit this movement. The characteristics of future prostheses must include: based on the "universal joint" principle, occupy minimum space, isometric, maintain tendon tension, an axis identical to the true axis of the wrist, to maintain the hand in line with the forearm, fixed without cement but, not shortened with time, possibilities of mechanical flexibility immediately and lastingly stable, to be easily replaced modularly. This ideal prosthesis will certainly exist one day and will take the place of the first carpal row avulsion. In the meantime, this technique will still have a long use.

Biomechanical Phenomena↗

Evaluation of acetabular stability in uncemented prostheses.

The stability of two commonly used uncemented acetabular prostheses fixed with either pegs or screws has been established by evaluating the torque strengths in ten cadaveric acetabulae. The initial stability of implants to simulated frictional loads was satisfactory compared to previous estimations of the frictional torques in polyethylene-on-metal and metal-on-metal articulations. Testing of the torque required to produce 2 degrees of rotation at the bone-implant interface showed that the peg fixation required significantly greater loads than did the screw fixation (P less than .03). Testing the prostheses to failure gave good results, although lower than previous cemented arthroplasty estimations. The margin of stability over the frictional torques that can be generated is such that it may affect the bony ingrowth into these prostheses. This may account for the common finding of fibrous ingrowth in these prostheses.

Acetabulum↗

Rheumatoid arthritis and hydroxyapatite-coated hip prostheses: five-year results. International ABG Study Group.

Medium- and long-term results from cemented total hip arthroplasty (THA) in patients with rheumatoid arthritis (RA) show a higher incidence of infection and aseptic loosening when compared to other diagnoses. Early results using uncemented prostheses are variable. Hydroxyapatite (HA) coatings are thought to improve early osseointegration in uncemented THA. In a prospective, international, multicenter clinical study, 32 RA patients who received 33 uncemented HA-coated prostheses were followed up for a minimum of 5 years. Medium-term clinical results are excellent. No infection or aseptic loosening has been recorded. Excellent osseointegration was observed radiographically. Bone remodeling was consistent with mainly proximal to midstem stress transfer. We conclude that uncemented, proximally HA-coated prostheses are a promising alternative to cemented prostheses for RA patients.

Adult↗

CAD by processing of computed tomography data and CAM of individually designed prostheses.

In the past an economic fabrication of individual prostheses used in reconstructive cranio-maxillo-facial surgery was not possible due to technical deficiencies. Now, through the consistent use of the most modern computer-based techniques developed in the field of industrial engineering, these costs can be reduced to an economic level. Mathematical freeform surfaces models are first created from helical computed tomography data. These serve as the basis for an efficient and idealized construction of prostheses geometries, and provide control-data for a computerized numerical control-fabrication. In 4 clinical cases this new processing technique has successfully been utilized in the fabrication of individually designed prostheses for the reconstruction of skull defects. The range of opportunities offered is reflected not only in the great variety of possible geometric details, but also in the fact that the prostheses may be manufactured--partly using indirect impression-taking techniques--from 3 different biocompatible materials so far and other applications are likely to turn up.

Computer Simulation↗

Radiographic assessment of structural defects in Björk-Shiley convexo-concave prostheses.

Following the implantation of Björk Shiley 60 degrees convexo-concave (BS-CC) prostheses, outlet strut fracture rates up to 2.5% per year have been reported. According to experimental results and clinical observations, single leg separations are regarded as the primary mechanisms leading to complete outlet strut fracture after a certain interval. In an experimental study the question was addressed, whether single leg separation can be identified by especially developed radiographic means, before outlet strut fracture occurs. Five BS-CC mitral prostheses (29-31 mm) with intentionally made single leg separations of defined gas sizes (0-75 microns) and one intact mitral prostheses were implanted in sheep in a double-blind study design. Repeat non-invasive investigations were then performed applying a recently developed fluoroscopy imaging technique with direct radiographic magnification (DIMA COR C22). Single leg separations with gap sizes of more than 25 microns were properly detected using DIMA COR C22. Separations 25 microns or less could not be detected with certainty but were evaluated as probable or possible as a result of multiple investigations. The intact prosthesis was correctly identified, but was investigated on only one occasion. Non-invasive control of Björk-Shiley CC mitral prostheses applying especially developed direct radiographic magnification may allow for a reliable assessment of single leg separation with gap sizes of more than 25 microns in sheep. Using this technique of non-invasive serial investigations on particular patients with high probability of outlet strut fracture appears feasible, anticipating single leg separation detectability in humans. This has to be assessed in a second step.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Bileaflet mechanical prostheses performance in mitral position.

OBJECTIVE: The experience with the Carbomedics (CM) and the St. Jude Medical (SJM) bileaflet mechanical prostheses was evaluated to determine thromboembolic and hemorrhagic complications and predictive risk factors. METHODS: From 1989 to 1994, a total of 625 patients had mitral valve replacement (CM, 240; SJM, 385); 32.5% (203), concomitant procedures and 32.8% (205), previous cardiac surgery, primarily valve replacement procedures. RESULTS: The pre-operative variables did not distinguish the populations, except for previous surgery CM 37.9% and SJM 29.6% (P < 0.05). The pre-operative variables (type of prostheses, cardiac rhythm, coronary artery bypass, NYHA III/IV, advancing age, gender, urgency status and previous surgery) were not predictive of overall thromboembolism (TE), major TE, minor TE, prosthesis thrombosis and hemorrhage (P not significant; P = NS). The linearized rate of total TE events for overall MVR was 5.0%/patient-year (CM 4.4; SJM 5.4). The < or = 30 day major crude rate was 0.44%, while the > 30 day late major event rate was 2.0%/patient-year. Of the total TE events 91% of < or = 30 days and 75%, > 30 days had an INR < 2.5 at or immediately prior to the event. The thrombosis rate (included in TE events) was 0.63%/patient-year (ten events, four managed successfully with thrombolysis, five successfully with reoperation, and one fatality identified at autopsy). The freedom, at 5 years, from major/fatal TE, thrombosis and hemorrhage from anticoagulation was 88.2%, and 89.5% exclusive of early events. CONCLUSIONS: This non-randomized prospective observational evaluation of the CarboMedics and St. Jude Medical prostheses has not revealed any differentiation in performance of the prostheses. The study serves as a single institution experience with the potential for future comparative evaluation.

Adult↗

Mechanical heart valve prostheses: identification and evaluation (erratum).

Mechanical heart value prostheses have been in use since the 1950s. Many prostheses have been used for a while and then discontinued. Today, there are a large number and variety of prostheses in use and an even larger variety that are in place in patients. These may be explanted at any time for a number of reasons. It is essential for the practicing pathologist to be able to identify the prosthesis and be aware of some of its reported complications and modes of failure. This article, and a second one on bioprosthetic heart valves, is designed as a ready reference guide to heart valve prostheses, their important identifying features, their common complications, and modes of failure. It should help in the accurate identification of explanted prosthetic valves and more definitive reports. This accuracy of identification as well as tracking of abnormalities noted will, we hope, permit the identification of new failure modes and the recording of causes of failure of new (or even modified) prosthetic heart valves.

Heart Valve Prosthesis↗

Speech assessment of patients using three types of indwelling tracheo-oesophageal voice prostheses.

A multidisciplinary prospective study compared speech acceptability between three types of indwelling tracheo-oesophageal voice prostheses. Twenty male laryngectomees took part over five years, using 42 prostheses. Speech was assessed on a discrete scale by trained and untrained personnel. The majority scored in the mid-range for each assessor. The kappa coefficient was used to test similarity between assessors, and for all pairings agreement was significant (p < 0.05). The speech and language therapist tended to give higher scores and the patient lower. A relationship was found between patients' ages categorized by decade and the surgeon's score alone. This relationship held for Groningen high resistance and Provox prostheses individually too (p < 0.05). The untrained assessed similarly to the professionals--humans are all voice listeners. The analysis suggests surgeons find tracheo-oesophageal speech in older patients better than in younger ones; or make more allowances for the elderly. There was a trend for Provox prostheses to produce the best scores.

Age Factors↗