Flow-injection enzymatic analysis for glycerol and triacylglycerol.

A flow-injection enzymatic analytical system was developed for determination of glycerol and triacylglycerol based on enzymatic reactions in capillary followed by electrochemical detection. The hydrogen peroxide produced from the enzyme reaction was monitored by a platinum-based electrochemical probe. Different immobilization strategies on silica support were studied. The best and most effective configuration found for the measurement of glycerol and triacylglycerols in this system was the tandem connection of a lipase column and a silica-fused capillary column coimmobilized with glycerokinase (GK) and glycerol-3-phosphate oxidase (GPO). Lipase helps the breakdown of triacylglycerol to yield free fatty acids and glycerol, while glycerokinase catalyzes the adenosine-5-triphosphate-dependent phosphorylation of glycerol to yield alpha-glycerol phosphate, which can subsequently be oxidized by 3-glycerol phosphate oxidase to produce hydrogen peroxide. Response-surface methodology (RSM) was applied to optimize the proposed system for glycerol. Experiment settings were designed by central composite design to investigate the combined effects of pH, flow rate, reaction temperature, and ATP concentration on collected signals. The fitted model, per RSM, showed that the optimum conditions of the system are 2 mM ATP in 0.1 M carbonate buffer (pH 11.0), flow rate of 0.18 mL/min, temperature of 35 degrees C, 20 microL of sample injection, and applied voltage of 0.650 V. The proposed biosensing system using lipase, GK, and GPO exhibited a flow-injection analysis peak response of 2.5 min and a detection limit of 5 x 10(-5) M glycerol (S/N = 3) with acceptable reproducibility (CV < 4.30%). It also had linear working ranges from 10(-4) to 10(-2) M for glycerol and from 10(-3) to 10(-2) M for triacylglycerol. The capillary enzyme reactor was stable up to 2 months in continuous operation, and it was possible to analyze up to 15 samples per hour. The present biosensing system holds promise for on-line detection of triacylglycerol in serum and glycerol content in fermented products.

Biosensing Techniques↗

Sensitive assay for catecholamines in pharmaceutical samples and blood plasma using flow injection chemiluminescence analysis.

A rapid and sensitive chemiluminescence (CL) method using flow injection analysis was described for the determination of three catecholamines: dopamine, adrenaline and dobutamine, based on their greatly enhancing effects on the CL reaction of luminol-potassium periodate in basic solutions. Under the optimized conditions, the calibration graphs relating the increase of CL intensity to the concentration of the analytes were linear. The present method allows for the determination of dopamine, adrenaline, and dobutamine over the range of 1.0 x 10(-10) - 1.0 x 10(-7) g/ml. The relative standard deviations for measurements (n=11) of dopamine, adrenaline and dobutamine were 2.9, 2.3 and 1.8% when the concentrations of three catecholamines were at 1.0 x 10(-9) g/ml, respectively. The detection limits of the method were 2.0 x 10(-11) g/ml dopamine, 1.0 x 10(-11) g/ml adrenaline and 4.0 x 10(-11) g/ml dobutamine. The method was successfully applied to the determination of three catecholamines in pharmaceutical samples and blood plasma.

Catecholamines↗

Fast simultaneous determination of niobium and tantalum by Kalman Filter analysis with flow injection chemiluminescence method.

A fast and highly efficient Kalman Filter analysis-flow injection chemiluminescence (FI-CL) method was developed to simultaneously determine trace amounts of niobium and tantalum in geological samples. The method, without the boring process of separation and dear instruments, is suitable for field scene analysis. The mixed chemiluminescence kinetic curve was analyzed by a Kalman Filter (KF) in this method to realize the simultaneous determination of niobium and tantalum. Possible interference elements in the determination were investigated. Under the selected conditions, the detection limits (3sigma, n = 11) of niobium(V) and tantalum(V) were 2.1 x 10(-3) microg g(-1) and 4.0 x 10(-3) microg g(-1), respectively, and the relative standard deviations were 4.9% and 3.3% (n = 9). The method was applied to the determination of niobium and tantalum in geological samples with satisfactory results.

Flow Injection Analysis↗

High-throughput screening of protein surface activity via flow injection analysis-pH gradient-dynamic surface tension detection.

Using flow injection analysis (FIA), a pH gradient is blended in real time with a protein sample as the pH-dependent protein surface activity is measured by a dynamic surface tension detector (FIA-pH-DSTD). This instrumental system was developed as a high-throughput method for the screening of protein surface activity at the air/liquid interface as a function of pH. This method utilizes the continuous flow, drop-based dynamic surface tension detector in combination with flow injection sample introduction and blending of a steady-state concentration of protein sample with a pH gradient ranging from pH 2.0 to pH 11.5. Dynamic surface tension is measured through the differential pressure across the air/liquid interface of repeatedly growing and detaching drops. Continuous surface tension measurement is achieved for each eluting drop of 2-s length (2 muL), providing insight into both the kinetic and thermodynamic behaviors of molecular orientation processes at the liquid/air interface. Three-dimensional data are obtained, with surface tension first converted to surface pressure, which is collected as a function of elution time versus drop time. In FIA-pH-DSTD, a commercial pH probe is used to measure pH during elution time, enabling surface pressure throughout drop time to be subsequently plotted as a function of eluting pH. An automated DSTD calibration procedure and data analysis method is applied, which allows simultaneous use of two different solvents, permitting real-time dynamic surface tension data to be obtained. The method was applied to the analysis of 14 commercial purified proteins, yielding characteristic features of surface activity as a function of pH. The reproducibility of the measurement and selectivity advantage of the DSTD was shown for the analysis of serum albumins from various mammalian sources. Several applications were also suggested and discussed in order to show the potential of the method for protein and food chemistry studies and in the study of protein-polymer interactions.

Journal Article↗

Evaluation of the antioxidant effect of melatonin by flow injection analysis-luminol chemiluminescence.

The antioxidant effect of melatonin was evaluated by using a flow injection analysis chemiluminescence (FIA-CL) method to measure alone its direct antioxidant behaviour in aqueous solutions. Inhibition by melatonin, DL-tryptophan or serotonin (5-hydroxytryptamine, 5-HT) of the steady CL emissions of various oxidants with luminol was measured. LogIC(50) values of melatonin were calculated: -2.6+/-0.1M for superoxide (O(2) radical(-)), -3.0+/-0.02 M, for hydrogen peroxide (H(2)O(2)), -4.7+/-0.04 M, for hypochlorous anion ((-)OCl), -2.8+/-0.1M, for hydoxyl (radical OH) and -2.0+/-0.03 M, for peroxynitrite (ONOO(-)). Thus melatonin exerted a limited direct antioxidant activity towards reactive oxygen species (ROS) in aqueous solutions, broadly comparable to that of tryptophan, but less than that of serotonin and of major antioxidants such as ascorbic acid. This suggests that where the benefits of melatonin are correctly attributed to antioxidant behaviour, this is mediated largely through antioxidant enzymes. The pharmacological implications are discussed.

Antioxidants↗

Flow injection analysis-atomic absorption determination of serum zinc.

Flow injection analysis-atomic absorption (FIA-AA) determination of zinc in human serum samples is demonstrated. The same samples were analyzed for zinc by conventional atomic absorption spectrometry and no significant difference was found between the two methods. Proteins were precipitated from samples by adding equal volumes of 25% (w/v) trichloroacetic acid and 100-microliter aliquots of the protein-free-filtrate were injected. Precision was +/-3.47% relative standard deviation. The frequency of measurements can be as high as 180 per hour. No pump was used, only the negative pressure from the nebulizer was utilized to aspirate the carrier stream. Simple 1:5 dilution of sample with water, followed by FIA-AA measurements, gave higher zinc levels. The effect of sample volume and the length of dispersion coil on the FIA signal was studied.

Humans↗

Solid-phase reactors as high stability reagent sources in flow analysis: selective flow injection spectrophotometric determination of cysteine in pharmaceutical formulations.

The flow injection spectrophotometric determination of cysteine was carried out by reaction with cobalt(II) ions entrapped in a polymeric material and filling a packed-bed reactor; the released cobalt(II) complexed with the amino acid was monitored at 360 nm. The method worked with a high repeatability, even with independent reactors, days and solutions. Selectivity of the procedure was tested with twenty different foreign compounds found in pharmaceutical formulations containing cysteine, parent amino acids included; no serious interferences were observed. The calibration graph for cysteine was linear over the range 1-90 micrograms ml-1 with a relative standard deviation of 0.8% at 60 micrograms ml-1 (n = 158). The calculated sample throughput was 90 h-1. The method was applied to determine the content of cysteine in pharmaceutical formulations.

Cobalt↗

Flow injection analysis-Rayleigh light scattering detection for online determination of protein in human serum sample.

A flow injection analysis (FIA) system combined with Rayleigh light scattering (RLS) detection is developed for the sensitive and rapid determination of protein concentration in human serum sample. This method is based on the weak intensity of RLS of Eriochrome Black T (EBT, 2-hydroxy-1-(1-hydroxy-2-naphthylazo)-6-nitronaphthalene-4-sulfonic acid sodium salt), which can be enhanced by the addition of protein in weakly acidic solution. The effects of pH and interfering species on the determination of protein were examined. Calibrations for protein, based on RLS intensity, were linear in the concentration ranges of 7-36 microg/ml for human serum album (HSA) and 8-44 microg/ml for bovine serum album (BSA). The detection limits of the method were found to be 0.882 and 2.507 microg/ml for HSA and BSA, respectively. A relative standard deviation of 0.76% (n=5) was obtained with 20 microg/ml HSA standard solution. The FIA-RLS method was more stable than the general RLS method, and the average RSD value of FIA-RLS was less than that of the general RLS. The sample rate was determined to be 90 samples per hour.

Animals↗

Disposable biosensor based on enzyme immobilized on Au-chitosan-modified indium tin oxide electrode with flow injection amperometric analysis.

Indium tin oxide (ITO) electrode is used to fabricate a novel disposable biosensor combined with flow injection analysis for the rapid determination of H2O2. The biosensor is prepared by entrapping horseradish peroxidase (HRP) enzyme in colloidal gold nanoparticle-modified chitosan membrane (Au-chitosan) to modify the ITO electrode. The biosensor is characterized by scanning electron microscope, atomic force microscope, and electrochemical methods. Parameters affecting the performance of the biosensor, including concentrations of o-phenylenediamine (OPD) and pH of substrate solution, were optimized. Under the optimal experimental conditions, H2O2 could be determined in the linear calibration range from 0.01 to 0.5 mM with a correlation coefficient of 0.997 (n=8). The amperometric response of the biosensor did not show an obvious decrease after the substrates were injected continuously 34 times into the flow cell. The prepared biosensor not only is economic and disposable, due to the low-cost ITO film electrode obtained from industrial mass production, but also is capable with good detection precision, acceptable accuracy, and storage stability for the fabrication in batch.

Biosensing Techniques↗

A comparative study of methods for determining selenium in biological materials.

A comparative study of the analytical performance of fluorimetric spectrophotometric, atomic absorption spectrometric, flow injection analysis with atomic absorption spectrometric, flow injection analysis with atomic absorption spectrometric detection, hydride generation with atomic absorption spectrometric detection and hydride generation with molecular emission cavity analysis detection methods has been carried out for the determination of selenium in biological materials. Based on results concerning detection limit, linearity and sensitivity, only the fluorimetric and hydride generation with atomic absorption spectrometric detection methods were suitable for the determination of selenium in biological materials. Whereas, the spectrophotometric, flame absorption spectrometric flow injection-atomic absorption spectrometric and hydride generation with molecular emission cavity detection, due to its worse detection limits and poorer sensitivities, were found to be unsuitable for the determination of selenium in such matrices. The accuracy of the fluorimetric and hydride generation with atomic absorption spectrometric detection methods were tested by using NBS standard reference materials.

Biological Products↗

[Recent progress in flow-injection chemiluminescence for pharmaceutical analysis].

Flow-injection chemiluminescence(FI-CL) analysis has made great progress in analytical chemistry for its high sensitivity with a wide linear range, simple instruments, rapidity and reproducibility in signal detection, and being appropriate for on-line analysis. A review with 74 references dating from 2002-early 2004 is given of the application of FI-CL method in the determination of drugs.

Animals↗

An oxidative column for the flow injection analysis-spectrophotometric determination of paracetamol.

A flow injection-spectrophotometric determination of paracetamol is reported. The procedure is based on the oxidation of the analyte with potassium hexacyanoferrate(III) previously retained in an anionic exchange column and the reaction of the N-(hydroxyphenyl)-p-benzoquinonimine so produced with phenol. The oxidation is carried out at room temperature and in aqueous ammoniacal solution. Concentrations of paracetamol in the 0.20-20 ppm range are determined with relative standard deviations (RSD) of 0.6% (n = 40) at an injection rate of 42 samples h-1. The influence of foreign species on the assay and its application to the determination of paracetamol in several pharmaceutical formulations are reported.

Acetaminophen↗

Pneumatic flow injection analysis-tandem spectrometer system for iron speciation.

A pneumatic flow injection-tandem spectrometer system, without a delivery pump was used for the speciation of iron. In this system, the suction force of a pneumatic nebulizer of a flame absorption spectrometer was used for solution delivery through the manifold. The Fe(III) and total Fe concentrations were determined using thiocyanate ion in a UV-Vis spectrometer and a FAAS, respectively. The Fe(II) was determined by the difference. The calibration curves were linear up to 18 microg mL(-1) and 25 microg mL(-1) with detection limits of 0.09 microg mL(-1) and 0.07 microg mL(-1) for Fe(III) and Fe(II), respectively. The mid-range precision and accuracy were <2.5% and +/-3% for the two species, respectively, at a sampling rate of 120 h(-1). This system was applied for the determination of Fe(III) and Fe(II) in industrial water, natural water and spiked samples.

Calibration↗

Development of a D-alanine sensor for the monitoring of a fermentation using the improved selectivity by the combination of D-amino acid oxidase and pyruvate oxidase.

A D-alanine (D-Ala) sensor for the monitoring of a fermentation process was developed using flow injection analysis (FIA). The FIA system consisted of a D-amino acid oxidase (D-AAOx) reactor, a Pyruvate oxidase (PyOx) electrode and a contrast electrode in the flow cell, and through the oxidation of D-amino acids in the D-AAOx reactor, pyruvic acid was formed only from D-Ala. The pyruvic acid was further oxidized with PyOx via the D-AAOx reaction. The amount of oxygen consumed in the PyOx reaction was proportional to the amount of D-Ala. It was possible to continuously repeat the assay up to 60 times at pH 6.8 and a flow rate of 0.18-ml min(-1). A linear relationship was obtained in the range of 0.1-1 mM D-Ala with a correlation coefficient of 0.987 and the detection limit was 0.05 mM. The relative standard deviation (R.S.D.) was 4.9% (n=5) for 0.5 mM D-Ala. The D-Ala content in some fish sauces was also determined using the proposed sensor system. The results obtained indicated a linear relationship between the amounts of D-Ala determined by the proposed sensor system and the conventional method. From the results, even if the substrate specificity of the enzyme (D-AAOx) was low, it was evident that the concentration of the original material (D-Ala) could be determined specifically when the first reaction product was changed by the second reaction (PyOx).

Alanine↗

Flow injection spectroscopic analysis of model drugs using on-line UV-diode array, FT-infrared and 1H-nuclear magnetic resonance spectroscopy and time-of-flight mass spectrometry.

A prototype flow injection analysis (FIA) system for the characterisation of compounds via a combination of diode array UV, 1H NMR, FT-IR spectroscopy and time-of-flight (TOF) mass spectrometry has been investigated using a number of pharmaceuticals and related compounds as model compounds. This combination of spectrometers allowed the on-flow collection of UV, 1H NMR, IR and mass spectra together with atomic composition data, enabling almost complete structural characterisation to be performed. Practical detection limits with the current system were in the region of 50 micrograms, however, the use of state of the art spectrometers would result in a significant reduction in the amount of material required.

Flow Injection Analysis↗

On-line flow sample stacking in a flow injection analysis-capillary electrophoresis system: 2000-fold enhancement of detection sensitivity for priority phenol pollutants.

A flow injection analysis-capillary electrophoresis system has been used for on-line flow stacking of 11 US Environmental Protection Agency priority phenol pollutants. Samples containing low concentrations of phenols dissolved in deionised water are continuously delivered to the capillary opening by means of a peristaltic pump. The sample components stack at the boundary between the highly conductive separation electrolyte and the introduced sample. By selecting an appropriate electrolyte and stacking conditions the movement of the electrolyte solution inside the capillary can be reduced, thereby improving the stacking efficiency. The electrolyte used here contained 20 mM phosphate, 8% 2-butanol, and 0.001% hexamethonium bromide at pH 11.95, and the stacking was carried out at 2 kV for 240 s. These conditions allowed up to 2000-fold preconcentration of the selected phenols. No matrix removal was necessary.

Electrophoresis, Capillary↗

Flow injection chemiluminescence analysis of phenolic compounds using the NCS-luminol system.

A flow injection system coupled with two simple and sensitive chemiluminescence (CL) methods is described for the determination of some phenolic compounds. The methods are based on the inhibition effects of the investigated phenols on the CL signal intensities of N-chlorosuccinimide-KI-luminol (NCS-KI-luminol) and NCS-luminol systems. The influences of the chemical and hydrodynamic parameters on the decrease in CL signal intensities of NCS-KI-luminol and NCS-luminol systems for hydroquinone, catechol, and resorcinol, serving as the model compounds of analyte, were studied in the flow injection mode of analysis. Under the selected conditions, the proposed CL systems were used for the determination of some phenolic compound and analytical characteristics of the systems including calibration equation, correlation coefficient, linear dynamic range, limit of detection, and sample throughput. The limits of detection for hydroquinone, catechol, and resorcinol were 0.002, 0.01, and 0.3 microM using the NCS-KI-luminol system; for the NCS-luminol system these were 0.01, 0.17, and 1.6 microM, respectively. The relative standard deviation for 10 repeated measurements of 0.04, 0.06, and 1 microM of hydroquinone, catechol, and resorcinol were 1.9, 1.4, and 2.0%, respectively, with the NCS-KI-luminol system; for 0.2, 0.5, and 4 microM of hydroquinone, catechol, and resorcinol these were 2.6, 2.2, and 3.7%, respectively, using the NCS-luminol system. The method was applied to the determination of catechol in known environmental water samples with a relative error of less than 6%. A possible reaction mechanism of the proposed CL system is discussed briefly.

Catechols↗

Epinephrine quantification in pharmaceutical formulations utilizing plant tissue biosensors.

A plant tissue biosensor associated with flow injection analysis is proposed to determine epinephrine in pharmaceutical samples. The polyphenol oxidase enzymes present in the fibers of a palm tree fruits (Livistona chinensis), catalyses the oxidation of epinephrine to epinephrinequinone as a primary product. This product is then electrochemically reduced (at -0.10 V versus Ag/AgClsat) on the biosensor surface and the resulting current is used for the quantification of epinephrine. The biosensor provides a linear response for epinephrine in the concentration range from 5.0 x 10(-5) to 3.5 x 10(-4) mol l(-1). The limit of detection estimated for this interval was 1.5 x 10(-5) mol l(-1) and the correlation coefficient of 0.998, working under a flow rate of 2.0 ml min(-1) and using a sample loop of 100 microl. The repeatability (R.S.D. for 10 consecutive determinations of a 3.0 x 10(-4) mol l(-1) epinephrine solution) was 3.1%. The results obtained by the method here proposed were compared with the official UV spectrophotometric procedure and also using a plant tissue reactor. The responses obtained with the proposed strategies were in good agreement with both ways of analyses, whereas the values obtained by the official spectrophotometric method was strongly affected by benzoic acid, present in the formulation of pharmaceutical product utilized for inhalation. Such favorable results obtained with the carbon paste biosensor or utilizing the bioreactor, joined with the simplicity of its preparation turns these procedures very attractive for epinephrine quantification in pharmaceutical products.

Arecaceae↗