[value of bone densitometry in pediatric renal transplantation].

OBJECTIVE: Renal transplantation improves many bone abnormalities inherent to chronic renal insufficiency, but also introduces new deleterious factors, especially those related to immunosuppressive drugs. We have studied the bone mineral content of 40 pediatric renal transplant recipients; moreover, we have analyzed its possible relationships with phosphorous-calcium metabolism, graft function and duration, steroid treatment and growth. PATIENTS AND METHODS: Bone mineral content was measured by dual energy X-ray absorptiometry (DEXA). The results were expressed as a z score in relation to age and sex. Immunosuppression was achieved by using triple therapy: azathioprine, cyclosporine A and prednisolone. At the time of the DEXA, 59% of the patients were on daily steroid treatment and 41% on alternate-day treatment. RESULTS: All patients presented bone mass losses with a maximal decrease between 5 and 21 months post-transplantation and a posterior tendency to recovery. Fifty percent of the children had severe osteopenia (bone mineral density < -1 SD). There was no statistically significant association between the severity of bone loss and values of ionized calcium, phosphorus, intact PTH, or calcitriol received. However, a linear correlation was found between cumulative steroid dose and osteopenia (r = -0.35, p < 0.05). Height and growth velocity were more affected in the severe osteopenia group. In this group, the proportion of children on daily steroid treatment was statistically higher (72% vs 45%, p < 0.05). CONCLUSIONS: Bone densitometry is an accurate, rapid and noninvasive method to measure renal transplant impact on the growing skeleton and it must be done in a periodic and standardized way.

Adolescent↗

[In vitro study of ultrasonic bone densitometry using dissected calcaneus].

Quantitative ultrasound (QUS) of the calcaneus is a widely utilized method for bone densitometry. However, the meaning of measured parameters, such as speed of sound (SOS) and broadband attenuation (BUA), is not well established. We performed in vitro measurement of dissected human calcaneus (n = 60; male 29, female 31; mean age 81 years) using two QUS machines and also measured bone densities using SXA, DXA and pQCT. Finally, we investigated breaking strength of the calcaneus and studied the correlation with QUS parameters and other assessed parameters. The two QUS measurements were in good agreement in most experiments. SOS correlated most closely with bone mineral densities assessed by pQCT and did not correlate with factors related to bone size, while BUA showed the highest correlation with BMC and association with parameters related with bone size such as bone area and bone width. With maximal breaking stress of the calcaneus, correlations were almost equal among QUS parameters and bone mineral density. We conclude that SOS is the parameter most closely associated with true bone mineral density (g/cm3), whereas BUA represents both bone mineral density and bone size, mimicing BMD assessed by DXA or SXA.

Aged↗

[Ultrasound bone densitometry of os calsis].

In the last couple of years, Ultrasound bone densitometry (QUS: Quantitative ultrasound) have been developed which allow the assessment of fracture risk caused by osteoporosis. QUS are particularly promising since they are simple, inexpensive, portable, non-invasive and they do not subject the patient to any ionising radiation. Additional investigations that assess innovative QUS techniques in well defined research settings are important to determine and utilize the full potential of this technology for the benefit of early detection and monitoring of osteoporosis.

Adult↗

A comparison of the optical Stiles-Crawford effect and retinal densitometry in a clinical setting.

PURPOSE: To compare the measurement of the optical Stiles-Crawford effect (SCE) to the densitometry of cone visual pigments in a clinical setting. Both tests provide information on outer retinal integrity, but the optical SCE can be performed in far less time. METHODS: Images acquired with a custom-built scanning laser ophthalmoscope were used to assess visual pigment density and optical SCE. Visual pigment density was regarded as the "gold standard." More than 100 patients with suspected, and some with known, outer retinal pathology were tested. The group included cases of central serous detachment, cone dystrophy, Stargardt's disease, Best's disease, and retinitis pigmentosa. RESULTS: Parameters of the optical SCE of 25 healthy subjects and 106 patients were taken through a stepwise linear regression to predict density. The correlation between predicted density from the optical SCE and the measured density was 0.82. The sensitivity of the optical SCE to detect decreased density was 96%. When only the foveal reflectance was considered, sensitivity was still 84% CONCLUSIONS: The optical SCE is a sensitive and fast method for detecting cone photoreceptor disturbances.

Adult↗

Determination of the subunit composition of haptoglobin 2-1 polymers using quantitative densitometry of polyacrylamide gels.

Human haptoglobin (Hp), a hemoglobin-binding glycoprotein containing two types of polypeptide chains, alpha and beta, in equimolar amounts linked by disulfide bonds, exists in three major phenotypes determined by the properties of the alpha chain: Hp 1-1 (alpha1), Hp 2-2 (alpha2), and Hp 2-1 (alpha1 and alpha2). Hp 2-2 and Hp 2-1 form a series of alpha-disulfide-linked polymers. The subunit composition of the Hp 2-1 series was studied by isolation of single Hp 2-1 polymers by polyacrylamide gel electrophoresis. After reductive disulfide cleavage and alkylation the relative content of alpha2 and alpha1 polypeptide chains was determined by quantitative densitometry of acid/urea polyacrylamide gels stained with Coomassie brilliant blue R250. The molar ratios alpha2/alpha1 for the Hp 2-1 polymers. P1 through P5 (in order of decreasing electrophoretic mobility), were found to be: P1, 0.0 (alpha1 only); P2, 0.48; P3, 0.97; P4, 1.6; P5, 2.0. Since one alphabeta-Hb half-molecule is known to bind to each Hp beta chain, the beta polypeptide chain content of each of the Hp 2-1 polymers could be estimated by by counting the number of Coomassie blue bands formed after electrophoresis of isolated Hp 2-1 polymers fractionally saturated with cyanmethemoglobin (Hb). The number of beta chains present in Hp 2-1 polymers P1 through P4 was determined to be: P1, 2; P2, 3; P3, 4 and P4, 5. Molecular weights of the Hp 2-1 polymers were determined by sodium dodecyl sulfate-polyacrylamide gel electrophoresus using as standards the almost homologous Hp 2-2 polymer series whose molecular weights are known from ultracentrifugation studies. Molecular weights for the first five Hp 2-1 polymers were estimated to be 107,000; 162,000; 217,000, 274,000; and 331,000, respectively. These data are consistent with the previously proposed model for the subunit composition of the Hp 2-1 polymer series when P1 = (alpha1 beta)2 and the subsequent polymers in order are represented as (alpha1 beta)2(alpha2 beta)n where n = 1,2,3,4...

Densitometry↗

[Verification and determination of opiates in the urine and blood with thin-layer chromatography followed by densitometry in fatal cases of drug abuse].

Urine and blood concentrations of free and total morphin or 6-monoacetylmorphin were presented in fatal cases of morphin type opiates abuse. A solid phase extraction method was developed for isolation of drugs and their metabolities from biological material which used Separcol small columns with non-polar contents SI C 18T. Thin layer chromatography with densitometry anabled screening for quality evaluations. Resultes were compared with those obtained by fluoropolarizing immunodetection on Abbotts TDxFLx device. Possibility and cause of false positive results were discussed when using initial, screening, commercially available immunotests.

Adolescent↗

Evaluation of decision rules for referring women for bone densitometry by dual-energy x-ray absorptiometry.

CONTEXT: Identification of women with low bone mineral density (BMD) is an important strategy in reducing the incidence of osteoporotic fractures. However, screening all women is not recommended. OBJECTIVES: To assess the diagnostic properties of 4 decision rules--Simple Calculated Osteoporosis Risk Estimation (SCORE), Osteoporosis Risk Assessment Instrument (ORAI), Age, Body Size, No Estrogen (ABONE), and body weight less than 70 kg (weight criterion)--for selecting women for dual-energy x-ray absorptiometry (DXA) testing and to compare results with recommendations made in the National Osteoporosis Foundation (NOF) practice guidelines. DESIGN AND SETTING: Analysis of data from the Canadian Multicentre Osteoporosis Study, a population-based community sample, collected from 9 study centers across Canada between February 1996 and September 1997. PARTICIPANTS: Postmenopausal women aged 45 years or older (N = 2365) without bone disease who had DXA data for the femoral neck, data to apply selection criteria, and who were not currently taking estrogens or who had been taking hormone replacement therapy for 5 or more years. MAIN OUTCOME MEASURES: Sensitivity, specificity, and area under the receiver operating characteristic (AUROC) curve of each of the 4 decision rules and the NOF guidelines for identifying women with a BMD T score of less than -1.0 SD, less than -2.0 SD, and no more than -2.5 SD at the femoral neck, and percentages of women recommended for testing, stratified by BMD level and age. RESULTS: The percent of women with a BMD T score less than -1, less than -2, and no more than -2.5 were 68.3%, 25.4%, and 10.0%, respectively. The AUROC curves were greatest using SCORE and ORAI. The sensitivity for identifying women with a BMD T score of less than -2.0 was 93.7% (95% confidence interval [CI], 91.8%-95.6%) using the NOF guidelines and was 97.5% (95% CI, 96.3%-98.8%), 94.2% (95% CI, 92.3%-96.1%), 79.1% (95% CI, 75.9%-82.3%), and 79.6% (95% CI, 76.4%-82.8%), respectively, using the SCORE, ORAI, ABONE, and weight criterion. However, the NOF guidelines also resulted in 74.4% (95% CI, 71.3%-77.6%) of women with a normal BMD (T score of -1.0 or higher) being tested compared with 69.2% (95% CI, 65.9%-72.5%), 56.3% (95% CI, 52.7%-59.8%), 35.8% (95% CI, 32.4%-39.2%), and 38.1% (95% CI, 34.6%-41.6%), respectively, using the 4 decision rules. Assessments suggest that ABONE and weight criterion are not useful case-finding approaches. CONCLUSION: The SCORE and ORAI decision rules are better than the NOF guidelines at targeting BMD testing in high-risk patients. The acceptability of these rules in clinical practice merits further investigation given their potential effect on the use of densitometry services.

Absorptiometry, Photon↗

Clinical use of bone densitometry: clinical applications.

Osteoporosis represents a difficult problem for physicians because, although many diagnostic tests are available, interpreting their results is not straightforward. As a result, many patients, even those with clear indications such as long-term steroid therapy or vertebral fractures on radiography, do not get screened or treated. Current evidence-based guidelines recommend screening for all white women older than 65 years and not already receiving an osteoporosis treatment and for many nonwhite women. For postmenopausal women who are younger than 65 years and have strong risk factors for osteoporosis, screening may also be beneficial. The optimal testing strategy depends on what is available locally. The best role for follow-up testing is still being defined, and interpretation of such testing is tricky. Reports of results can be hard to understand; a randomized controlled trial of clearer reports increased testing and decreased confusion about the meaning of test results. Densitometry might be more effectively used in practice if strategies such as having patients fill out a short questionnaire to assess for risk factors or creating a nurse-based system were used to identify patients. Clinicians need better approaches for identifying patients most likely to benefit from screening, systems that facilitate their application, and test results that are easy to interpret.

Absorptiometry, Photon↗

Evolution of bone densitometry in patients with myeloma treated with conventional or intensive therapy.

BACKGROUND: Demineralization is a common hallmark of multiple myeloma (MM) that can be evaluated by dual-energy X-ray absorptiometry (DEXA). The evolution of lumbar and whole body bone density were investigated by DEXA in patients with MM treated by conventional or intensive therapy supported by autologous blood stem cell transplantation. METHODS: Sixty six patients younger than 66 years with MM were randomly assigned to either conventional (30 patients, Group A) or intensive therapy supported by autologous blood stem cell transplantation (36 patients, Group B). For all patients, lumbar bone mineral density (BMD) was measured by DEXA at diagnosis and 13.2 +/- 4.2 months after the initiation of treatment. Whole body examinations were performed in 45 patients; in addition to whole body BMD, independent BMD values were recorded for various skeletal sites. RESULTS: At diagnosis, mean lumbar Z score (lumbar mean BMD value) was low (-1.24 +/- 1.45) without any significant difference between the 2 groups. Under treatment, lumbar BMD increased 0.7% in Group A and 4.6% in Group B (P = 0.02). This difference was mainly related to nonresponders in group A who featured a lumbar BMD change of -3.9%, whereas patients in remission in both groups displayed a 4.1% increase (P < 0.001). There was a correlation between the variation of lumbar BMD and the decrease of the serum or urinary monoclonal component (r = 0.34, P = 0.006). After intensive therapy, increase of lumbar BMD was higher in men than in women (7.2% vs. 1%, P = 0.005) perhaps because of variations in hormonal status in women. Unexpectedly, whole body BMD decreased in responders (-3%) because of a decrease in appendicular BMD outweighing the increase in axial BMD. This suggests a redistribution from cortical to cancellous bone in patients with MM responsive to chemotherapy. CONCLUSION: Bone densitometry is a marker of treatment response that may be particularly useful in nonsecretory and light chain MM. Moreover, it provides new information on bone remodeling in patients treated for MM, which may have therapeutic consequences.

Absorptiometry, Photon↗

New approaches for interpreting projected bone densitometry data.

Bone densitometry using dual-photon absorptiometry (DPA) or dual-energy x-ray absorptiometry (DXA) has become a standard method for assessing bone mineral content in the spine and other skeletal regions. A projected areal density, referred to as bone mineral density (BMD,g/cm2), is normally calculated to assess regional bone density and strength. We demonstrate that this measure can be misleading when used to compare bones of different sizes due to inherent biases caused by bone thickness differences. For example, assuming that volumetric bone density remains constant and bony linear dimensions are proportional to height, a 20% increase in height would result in a 20% increase in both the thickness and the BMD of any bone. We describe new analysis methods to reduce the confounding effect of bone size, and we introduce a parameter, bone mineral apparent density (BMAD, g/cm3), that better reflects bone apparent density. Using this parameter, we calculate a quantity that serves as an index of bone strength (IBS, g2/cm4) for whole vertebral bodies. These analyses were applied to lumbar spine (L2-4) DXA measurements in a population of women 17-40 years old and appear to offer advantages to conventional techniques.

Absorptiometry, Photon↗

Normalization of spine densitometry.

We investigated several transformations of bone mineral content (BMC) and area density (BMD), in particular volumetric density (BMAD), to ascertain the influence on (1) body size dependence, (2) diagnostic sensitivity, and (3) precision. These transformations were examined in a group of 657 normal postmenopausal women and 327 women with osteoporotic fracture. First, expression of results as BMAD removed some of the slight dependence on body size; 21% of the variation in BMC and 15% of the variation i BMD were associated with body weight, but only 8% with BMAD. Second, the Z scores compared with those for age-matched controls for BMD and BMC were -1.85 and -1.71, respectively; the Z score for BMAD was -1.64. Third, the precision error for BMC was reduced by expressing results as BMD (1.1 versus 0.5%); BMAD degraded precision slightly (0.7%). BMD appeared to be the optimal expression for bone densitometry because it provided the best diagnostic sensitivity and lowest precision error; there was a minimal influence of body size on BMD results. This study also showed that osteoporotic women, even in the first postmenopausal decade, had low spine BMD, small vertebral area, and low body weight. Such women may be particularly at risk of crush fracture.

Absorptiometry, Photon↗

Osteoporosis: diagnosis by plain chest film versus dual photon bone densitometry.

Readers of chest radiographs often comment on the presence of osteoporosis. We have hypothesized that diagnoses of osteoporosis from chest films are not reliable even when made by experienced radiologists. To test this hypothesis, we had nine radiologists estimate the degree of bone density seen on 45 lateral chest films. We compared their estimates of bone density to the results of dual photon bone densitometry of the lumbar spine. We found that there was little ability to accurately diagnose osteoporosis by chest film since the group of nine readers achieved accuracies ranging from 0.59 to 0.64. Therefore, we feel it is unjustified to comment upon the presence or absence of osteoporosis on the basis of chest films.

Absorptiometry, Photon↗

Ultrasound and densitometry of the calcaneus correlate with the failure loads of cadaveric femurs.

We assessed the bone mineral density (BMD) of 16 matched sets of cadaveric proximal femurs and feet using dual-energy x-ray absorptiometry (DXA). We also estimated the femoral neck length from the DXA scans. Quantitative ultrasound densitometry was used to measure the velocity of sound and broadband ultrasound attenuation (BUA) in the calcaneus of each foot. The proximal femurs were then tested to failure in a loading configuration designed to simulate a fall with impact to the greater trochanter. Femoral neck BMD and trochanteric BMD were strongly associated with the femoral failure load (r2 = 0.79 and 0.81, respectively; P < 0.001), whereas femoral neck length was modestly correlated with femoral failure load (r2 = 0.27, P = 0.04). Calcaneal BMD (r2 = 0.63, P < 0.001) and BUA (r2 = 0.51, P = 0.002) were also significantly associated with femoral failure load. Given the small sample size, we were unable to detect differences in the strength of the correlations between the independent parameters and femoral failure load. Using linear multiple regression analyses, the strongest predictor of femoral failure load was a combination of femoral neck BMD and femoral neck length (R2 = 0.85, P < 0.001). Thus, it appears that both femoral and calcaneal bone mineral properties may be useful for identifying those persons at greatest risk for hip fracture.

Absorptiometry, Photon↗

Metacarpal bone mass in normal and osteoporotic Japanese women using computed X-ray densitometry.

The metacarpal bone mineral density (BMD) and metacarpal index (MCI) of the second metacarpal bone were measured by computed X-ray densitometry (CXD) (Teijin Ltd., Tokyo), which we have established with the development of microdensitometry of radiographs. In this study, we evaluated the basic attributes of this CXD method and determined the age-related changes in both metacarpal measurements in normal Japanese women. The precision in vivo was measured in eight subjects. The precision errors [coefficient of variation (CV)] were 0.2-1.2% CV for metacarpal BMD and 0.4-2.0% CV for MCI, respectively. We have obtained low precision error and more rapid analysis, within 3 minutes respectively, compared with the previous methods. Age-related changes in the metacarpal measurements were evaluated in 1438 normal women. Both measurements showed the most significant decrease in the sixth decade of life. The rate of decrease in the sixth decade was 1.6%/year for metacarpal BMD and 1.5%/year for MCI. On comparison between metacarpal BMD by CXD and spine BMD using dual energy X-ray absorptiometry (DXA) in 248 normal women with and without menstruation, the two measurements were found to be similarly decreased in the subjects within 5 years after menopause. There was also no significant difference in the Z-score between metacarpal BMD and spine BMD within 5 years after menopause. These results indicate that early postmenopausal bone loss occurs not only in the spine but also in the metacarpal bone.(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon↗

Initiation of hormone replacement therapy after diagnosis of osteoporosis by bone densitometry.

The effect of osteoporosis, as diagnosed by bone densitometry, on general practitioners' decisions to initiate hormone replacement therapy (HRT) was assessed. Data for the study were collected by questionnaire from 147 women (> 40 years), previously referred for measurement of bone mineral density (BMD) at the proximal forearm. Among the women, at the time of BMD measurement, current and ever use of HRT was 35% and 50% respectively, and 25.2% were osteoporotic on the basis of their BMD level. HRT was more likely to be initiated by women who were told that their BMD was low (ODR 3.4; 95% CI 1.2-9.7); 37% of all women with osteoporosis were using HRT compared with 78% who were taking calcium supplements. Potential reasons for the low HRT prescription may include the nature of the BMD report, patient aversion to HRT and doctors' concern with the long-term side-effects of HRT.

Absorptiometry, Photon↗

Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques.

Assessment of precision errors in bone mineral densitometry is important for characterization of a technique's ability to detect longitudinal skeletal changes. Short-term and long-term precision errors should be calculated as root-mean-square (RMS) averages of standard deviations of repeated measurements (SD) and standard errors of the estimate of changes in bone density with time (SEE), respectively. Inadequate adjustment for degrees of freedom and use of arithmetic means instead of RMS averages may cause underestimation of true imprecision by up to 41% and 25% (for duplicate measurements), respectively. Calculation of confidence intervals of precision errors based on the number of repeated measurements and the number of subjects assessed serves to characterize limitations of precision error assessments. Provided that precision error are comparable across subjects, examinations with a total of 27 degrees of freedom result in an upper 90% confidence limit of +30% of the mean precision error, a level considered sufficient for characterizing technique imprecision. We recommend three (or four) repeated measurements per individual in a subject group of at least 14 individuals to characterize short-term (or long-term) precision of a technique.

Absorptiometry, Photon↗

Determination of cardiac ejection and valvular regurgitant fraction by on-line digital densitometry--methodology, validation, and application.

Videodensitometry allows to obtain both left and right ventricular ejection fraction (EF) and aortic or pulmonary regurgitant fraction (RGF) from the wash-out curve of contrast medium. We developed this technique to digital densitometry and integrated it in the standard digital image acquisition system 'Digitron' using Siemens user's library. Sources of error like scatter radiation, veiling glare, accumulation of iodine in tissue, and inhomogeneous contrast mixing were considered by using ECG gated image subtraction, background reference regions, data fit to ideal wash-out curves and calculation of EF and RGF exclusively from density differences. The method was validated by phantom studies in which simulated angiocardiograms were generated with given values of EF (50 to 70%) and RGF (0 to 45%). The results tended to overestimate RGF by up to 10 percent points, when image contrast was high and the ventricle was masked poorly by the lead shutters. In the clinical setting, the reliability of the results can be judged from the fit of the wash-out curve presented automatically on the screen on a semi-logarithmic scale. The technique is available to the physician in the catheterization laboratory on-line during or immediately after the examination, which facilitates routine use.

Absorptiometry, Photon↗

Improving the applicability of myocardial densitometry and parametric imaging by extended automated densogram analysis.

In clinical applications the analysis of X-ray contrast densograms acquired in regions of interest (ROI's) over the myocardium is disturbed by many complex factors. For this reason we acquire redundant densogram information for quality control before extracting densitometric parameters. In our approach, initially some stable measures of quality for densograms are used to lower the influence of poor quality densograms by a quality weighted averaging. For example a shape quality measure, Q1, is calculated using regions of optimal and minimal acceptable quality defined with respect to a prototype densogram. Not a few myocardial ROI's yield densograms that differ from single-source densograms (SSD's) due to e.g. superposition of different perfusion beds or the position of the ROI relative to the coronary sinus or stenoses. This might result in a densogram shape with oscillating or plateau behavior. For densograms of a such general shape many parameters defined in the usual way do not depend smoothly on the densogram values. The conventional definitions of some parameters (appearance time, rise time) are therefore extended for application to multi-maxima densograms as well as to SSD's. These new methods are evaluated using digitized clinical angiocardiograms and are applied to parametric imaging (pixeldensograms) in a slightly modified way. Taking into account the densogram quality, its shape and its origin results in a considerable improvement both for densitometry and parametric imaging of myocardial perfusion.

Absorptiometry, Photon↗