Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CYCLOPLEGICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

[Diode laser in "Malignant Glaucoma" treatment].

UNLABELLED: Malignant glaucoma remains one of the most dramatic complications of ocular surgery. It can occur after glaucoma surgery but also after iridotomy, capsulotomy, or cataract extraction. However, the mechanisms remain unclear. PURPOSE: to evaluate diode laser cyclodestruction as a complementary treatment in refractory malignant glaucoma. PATIENTS: Seven women with malignant glaucoma with onset several months before (mean, 43 months; range, 12-96 months), in whom shallow anterior chamber and high IOP (25 mmHg +/- 5.5 treated with 2.86 +/- 0.9 topical and systemic medications) persisted despite prior surgical treatment (mean, 2; range, 1-5). Controlateral eyes had hyperopia (mean, +3.7 D, range, +1 to +6), five had shallow anterior chamber and high IOP. UBM detected plateau iris in four women. METHODS: Seven eyes with malignant glaucoma and three controlateral eyes underwent cyclodestruction with diode laser (Viridis Twin Quantel Medical, laser, 810 nm), 22 burns around 270 degrees , 2 mm from the limbus for glaucomatous eyes and 15 inferior burns for controlateral eyes. RESULTS: Resolution of malignant glaucoma, with lower pressure (mean, 35%; range, 10%-70%), lower levels of medications (64%), final IOP at 13.2 mmHg (+/- 4.7), and deepening anterior chamber was achieved in all cases (mean follow-up, 18 months; range, 12-22). Cycloplegic topical treatment was stopped in 70% of cases. CONCLUSION: Diode laser cyclodestruction can help to resolve refractory malignant glaucoma. Larger UBM studies could help us to better understand the mechanisms of malignant glaucoma.

Adult↗

Solubilization of tropicamide by hydroxypropyl-beta-cyclodextrin and water-soluble polymers: in vitro/in vivo studies.

1% (w/v) aqueous solutions of tropicamide (TR), a poorly water-soluble mydriatic-cycloplegic drug, are usually obtained by adjusting the pH to approximately 5.0, at the expense, however, of ocular tolerance and bioavailability. The capacity of hydroxypropyl-beta-cyclodextrin (HP-beta-CD) to solubilize TR in pH 7.4 0.02 M phosphate buffer was investigated in the absence and presence of hydrophilic polymers (PVP, CMC and HPMC). Approximately 3.5% (w/v) HP-beta-CD was required to solubilize 1% (w/v) TR in pH 7.4 buffer at room temperature. The required amount was reduced to 0.9% (w/v) by heating at 120 degrees C in the presence of 0.1% (w/v) HPMC. Mydriatic activity tests in rabbits showed an improved bioavailability and maximal mydriatic response for two CD formulations, with and without HPMC, when compared to standard 1% (w/v) TR eyedrops, buffered at pH 5.0. The improved in vivo behaviour of the CD formulations are likely due to their physiological pH, resulting in a reduced irritant effect, although an effect of HP-beta-CD on corneal permeability cannot be dismissed a priori.

2-Hydroxypropyl-beta-cyclodextrin↗

Preparation and evaluation of liposomal formulations of tropicamide for ocular delivery.

Tropicamide, a mydriatic, cycloplegic drug was entrapped in liposomes. Liposomes were investigated by laser counting studies, transmission electron microscopy and differential scanning calorimetry for characterization. The precorneal clearance of liposomes was compared with solution by gamma-scintigraphy in the rabbit. The neutral liposomes failed to demonstrate significant enhancement in precorneal retention in comparison with aqueous solution. The potential of liposomes as an ophthalmic drug delivery system was investigated by comparing pupil dilatory effect of tropicamide by topical instillation, in the rabbit eye, of the solution and various drug-loaded liposomal forms, i.e. neutral liposomes, positively charged liposomes and neutral liposomes dispersed in 0.25% (w/v) polycarbophil gel. The positively charged liposomal formulation and liposomes dispersed in polycarbophil gel were found to be more effective than neutral liposomal dispersion when data were statistically treated at the 5% level of significance.

Animals↗

Laser in situ keratomileusis to correct residual myopia and astigmatism after radial keratotomy.

PURPOSE: To evaluate the safety and efficacy of laser in situ keratomileusis (LASIK) in selected post-radial-keratotomy (RK) eyes with residual myopia and astigmatism. SETTING: TLC-The Brea Laser Eye Center, Brea, California, USA. METHODS: Nine eyes of 6 patients who had had RK but had residual myopia and/or astigmatism had LASIK. All RK eyes had 8 radial incisions, were more than 1 year post-RK, had no epithelial inclusion cysts or corneal disease, and had had no subsequent ocular surgery. Follow-up was a minimum of 13 months, at which time uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), manifest refraction, cycloplegic refraction, keratometry, central and peripheral pachymetries, intraocular pressure, and a subjective assessment of visual function were obtained. RESULTS: At the last follow-up, the mean spherical equivalent (SE) was -0.156 diopter (D) +/- 0.174 (SD). All eyes treated for distance vision had a UCVA of 20/25 or better. No patient lost BCVA. No intraoperative or postoperative complications occurred. Seven eyes had morning and evening measurements. The mean change in manifest SE from morning to evening was -0.143 D. Six of the 7 eyes (86%) had 0 to 1 Snellen line change in UCVA from morning to evening. The subjective questionnaire revealed a high degree of satisfaction with overall vision, minimal glare, and less fluctuation in daily vision than before LASIK. CONCLUSION: Laser in situ keratomileusis is safe and efficacious for reducing residual myopia and astigmatism in properly selected RK patients.

Astigmatism↗

Limbal relaxing incisions in congenital astigmatism: 6 month follow-up.

PURPOSE: To evaluate the effectiveness of limbal relaxing incisions (LRIs) for correcting naturally occurring astigmatism. SETTING: Ankara Hospital, Ankara, Turkey. METHODS: This prospective analysis of the results of the first LRIs in 22 eyes of 13 patients with congenital astigmatism was done using a modified Gills nomogram and was based on preoperative refractive astigmatism determined by manifest and cycloplegic refractions. There were no adjustments based on sex or age. RESULTS: An absolute decrease of 0.91 diopter (D) (44%) in mean astigmatism was achieved after 6 months in 22 eyes. The mean uncorrected visual acuity (logMAR) increased from 0.42 to 0.26 from preoperatively to 6 months postoperatively. No patient lost best corrected visual acuity. Most regression occurred in eyes with more than 3.50 D of astigmatism and between the first and third postoperative months. CONCLUSION: Limbal relaxing incisions are a practical, simple, and forgiving approach for the correction of lower degrees of astigmatism.

Adolescent↗

One year results of European Multicenter Study of intrastromal corneal ring segments. Part 1: refractive outcomes.

PURPOSE: To assess the efficacy, predictability, stability, and safety of correcting myopia with intrastromal corneal ring segments (ICRS, KeraVision, Inc.). SETTING: Twelve European investigational sites. METHODS: Patients with myopia of -1.0 to -6.0 diopters (D) and best spectacle-corrected visual acuity (BSCVA) of 20/20 or better (except in 3 eyes) were assigned to receive 1 of 5 ICRS thicknesses (0.25, 0.30, 0.35, 0.40, or 0.45 mm). Efficacy was assessed by postoperative uncorrected visual acuity (UCVA), predictability of refractive outcome (deviation from predicted cycloplegic refraction spherical equivalent), and stability of refractive effect (manifest refraction spherical equivalent [MRSE]). Safety was assessed by maintenance or loss of preoperative BSCVA and induced manifest refraction cylinder. Measurements were made preoperatively and 1 and 7 days and 1, 2, 3, 6, and 12 months postoperatively. RESULTS: One hundred fifty-nine ICRSs were implanted in the eyes of 107 patients (52 patients had bilateral implantation). Preoperatively, UCVA was worse than 20/40 in 98% of eyes (155/159); 12 months postoperatively, it was 20/20 or better in 63% of eyes (83/132) and 20/40 or better in 96% (127/132). Predicted refractive corrections for each ICRS thickness generally correlated with achieved corrections. At 12 months postoperatively, 90% of eyes (124/138) were within +/-1.00 D of plano (MRSE). Two or more lines of BSCVA were lost in 6% of eyes (8/135); all 8 eyes had BSCVAs of 20/25 or better. CONCLUSION: The ICRS safely, effectively, and predictably reduced or eliminated low to moderate myopia. Refractive correction was stable through the 12 month follow-up.

Adult↗

Anterior chamber intraocular lens for high myopia: five year results.

PURPOSE: To evaluate the effectiveness of the surgical correction of high myopia 5 years after anterior chamber intraocular lens (IOL) implantation and to analyze the lens position and related complications. SETTING: Federal University of São Paulo-Escola Paulista de Medicina, São Paulo, Brazil. METHODS: This prospective study comprised 26 eyes that were implanted with an anterior chamber IOL (model ZB5M) and had a minimum follow-up of 5 years. Before and after surgery, manifest and cycloplegic refractions were done; slitlamp examination was performed; anterior chamber depth was measured; and keratometry, ophthalmoscopy, and central corneal endothelial cell count were performed. At the last follow-up, computerized biomicroscopy of the anterior segment was also done. RESULTS: The spherical equivalent decreased from -16.5 diopters (D) +/- 4.1 (SD) preoperatively to -0.9 +/- 0.9 D postoperatively. At the last examination, 57.7% of eyes had a spherical equivalent refraction within +/-1.0 D of emmetropia. Of eyes with a preoperative best spectacle-corrected visual acuity of 20/40 or better, 73.3% had an uncorrected visual acuity of 20/40 or better postoperatively. The mean tilt caused by the IOL was 4.4 +/- 2.7 degrees (range 0.5 to 12.2 degrees) and the mean IOL decentration, 0.3 +/- 0.2 mm (range 0.02 to 0.8 mm). The mean decrease in the endothelial cell count was 1.5%, with a mean cell density of 2808 +/- 305 cells/mm2 preoperatively and 2765 +/- 242 cells/mm2 postoperatively. Pupillary ovalization was observed in 12 eyes (46.1%). CONCLUSIONS: The anterior chamber IOL safely and effectively corrected high myopia.

Adult↗

Long-term follow-up of Intacs from a single center.

PURPOSE: To evaluate the long-term visual results in patients having Intacs placement for the correction of mild myopia. SETTING: Department of Ophthalmology, Mount Sinai School of Medicine and the Mount Sinai Hospital of Mount Sinai NYU Health, New York, New York, USA. METHODS: Patients with mild myopia (spherical equivalent between -0.75 and -4.50 diopters [D]) were enrolled to have Intacs placement between May 1995 and March 1999 under United States Food and Drug Administration Phase II and Phase III clinical trials for intrastromal corneal ring segments (ICRS). Six insert thicknesses were evaluated: 0.21, 0.25, 0.30, 0.35, 0.40, and 0.45 mm. The long-term results evaluated were uncorrected visual acuity (UCVA), maintenance of best spectacle-corrected visual acuity (BSCVA), predictability and stability of the refractive effect, induced manifest refraction cylinder, slitlamp findings, self-reported visual symptoms, and maintenance of mesopic contrast sensitivity. RESULTS: One hundred fourteen eyes of 73 patients were enrolled; 113 eyes of 72 patients received Intacs. There were no serious intraoperative or postoperative complications. The mean follow-up was 17.5 months +/- 8.9 (SD). At the end of this period (number of eyes evaluated = 100), the UCVA was 20/40 or better in 95 eyes (95.0%), 20/20 or better in 72 (72%), and 20/16 or better in 41 (41%). None of the 113 eyes lost 10 or more letters or 2 or more lines of preoperative BSCVA. The mean change in the cycloplegic refraction spherical equivalent for the 6 insert thicknesses was as follows: -0.75 +/- 0.00 D for 0.21 mm; -1.17 +/- 0.42 D for 0.25 mm; -2.00 +/- 0.54 D for 0.30 mm; -2.59 +/- 0.53 D for 0.35 mm; -3.09 +/- 0.54 D for 0.40 mm; and -3.82+/-0.80 D for 0.45 mm. The refractive correction was within +/-1.0 D of the predicted outcome in 103 eyes (92.0%) and within +/-0.5 D in 72 eyes (63.7%). Intacs were removed from 6 eyes (5.3%). All 4 eyes for which data were available 3 months after removal returned to within +/-0.5 D of their preoperative manifest refraction spherical equivalent. Intacs were exchanged because of undercorrection in 2 eyes (1.8%). These eyes gained 3 and 5 lines of UCVA 12 months and 18 months, respectively, after the exchange procedure. Overall, 85.7% (36/42) of the patients were satisfied with the results of the Intacs procedure. CONCLUSION: Intacs safely and effectively corrected mild myopia. Placement is a brief, easy outpatient procedure. The refractive effect was predictable and stable over long-term follow-up. Results from a limited number of removal and exchange procedures indicate that Intacs are removable and adjustable.

Adult↗

Anterior uveitis after laser in situ keratomileusis.

PURPOSE: To report a case series of anterior uveitis after laser in situ keratomileusis (LASIK) and the incidence of anterior uveitis at a mean of 3 years. SETTING: Centro Medico Docente La Trinidad and Clinica Oftalmologica Centro Caracas, Caracas, Venezuela. METHODS: Five refractive surgeons and 18488 eyes that had surgical correction of a mean ametropia of -2.23 diopters (D) (range -10.25 to +4.25 D) participated in the study; 74.3% of the eyes were myopic. Laser in situ keratomileusis was performed in all eyes. Patients were followed for a mean of 36 months (range 6 to 48 months) after LASIK. The clinical charts of patients who developed uveitis after LASIK were reviewed. The mean preoperative intraocular pressure (IOP) was 15.2 mm Hg (range 12 to 19 mm Hg). The mean corneal ablation depth was 37.47 micro m (range 12 to 98 micro m). In the immediate postoperative period, all patients received a combination of topical dexamethasone and tobramycin. RESULTS: Thirty-five eyes (18 patients) developed anterior uveitis after LASIK. Signs and symptoms appeared a mean of 20.7 days (range 17 to 28 days) postoperatively and 5.08 days (range 2 to 8 days) after withdrawal of topical steroid and antibiotic agents. Eyes that developed LASIK-related uveitis had a mean preoperative spherical equivalent of -2.32 D (range -7.00 to +4.25 D). Intraocular pressure dropped to a mean of 8.0 mm Hg (range 4 to 12 mm Hg) at the onset of uveitis (P <.0001). The LASIK-related anterior uveitis resolved and IOP returned to baseline after a mean of 3 days on topical steroid and cycloplegic agents. Laboratory and immunology (including human leukocyte antigen-B27) tests were negative in 15 of 18 patients (83.33%). The incidence of uveitis after LASIK was 0.18%. CONCLUSIONS: Anterior uveitis after LASIK is infrequent. It may be due to uveal trauma during surgery with disruption of normal anterior-chamber-associated immune deviation, decreased antiinflammatory cytokines, and increased proinflammatory cytokines. Further studies are needed to investigate the mechanisms of this association.

Adult↗

Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients.

PURPOSE: To determine the accuracy of measurement by the SureSight autorefractor (software version 2.0) and the influence of accommodation. SETTING: Pediatric Section, Department of Ophthalmology, University of Hamburg, Hamburg, Germany. METHODS: In a series of comparative measurements, autorefractor readings were compared with cycloplegic retinoscopy in 195 eyes of 108 patients (1 to 81 years) measured under cycloplegia. Ninety-six eyes were also measured without cycloplegia. RESULTS: The wavefront autorefractor was able to refract human eyes from a distance of 0.35 m. The accuracy was lower than that with conventional tabletop autorefractors. A difference of less than 0.51 diopter (D) was found in 68% of the spherical equivalents under cycloplegia. Many emmetropic and hyperopic children accommodated during the noncycloplegic measurements and were minus-overcorrected up to -6.13 D. In our group of young patients (2 to 17 years), 47% were minus-overcorrected by more than -2.00 D. CONCLUSIONS: The wavefront autorefractor uses a new method to determine the refractive state of the eye from a distance. It was less accurate than other conventional autorefractors. A benefit is its application in infants and disabled and uncooperative subjects. Cycloplegia is necessary in young hyperopic patients.

Accommodation, Ocular↗

Possible adverse effects of drugs used in refractive surgery.

Adverse drug reaction reports were compiled from the National Registry of Drug-Induced Ocular Side Effects, Casey Eye Institute, Portland, Oregon, USA; the United States Food and Drug Administration, Rockville, Maryland; the World Health Organization, Uppsala, Sweden; and a Medline literature review of the past 50 years. The reported side effects of mydriatics, cycloplegics, benzodiazepines, tetracyclines, iodine, topical anesthetics, medications used for hemostasis, nonsteroidal antiinflammatory drugs, steroids, antibiotics, and artificial tears are described. Physicians should be aware of the side-effect profile and current industry standards for medications used in corneal refractive surgery, including off-label uses. Guidelines are provided for some classes of medications.

Anesthetics, Local↗

Clinical results of excimer laser photorefractive keratectomy for high myopic anisometropia in children: four-year follow-up.

PURPOSE: To evaluate the visual and refractive results of multizonal photorefractive keratectomy (PRK) for high myopic anisometropia and contact-lens intolerance in children. SETTING: Department of Ophthalmology, Masaryk University Hospital, Brno, Czech Republic. METHODS: Twenty-one patients aged 7 to 15 years with high myopic anisometropia had multizonal PRK in the more myopic eye and were retrospectively analyzed. The scanning-slit Nidek EC-5000 excimer laser was used. Postoperatively, patients were reviewed at 1 and 3 days, 1 week, and 1, 3, 6, 12, 18, 24, 36, and 48 months. The examination included cycloplegic refraction, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), biomicroscopy, grading of postoperative haze, corneal topography, pachymetry, intraocular pressure, biometry, orthoptic status, binocular vision (BV), and fundus evaluation. The safety, efficacy, predictability, and stability of the procedure were evaluated. Long-term binocular vision outcome was analyzed. All patients completed a 4-year follow-up. RESULTS: The mean preoperative spherical equivalent (SE) refraction was 8.93 diopters (D) +/- 1.39 (SD) (range -6.75 to -11.75 D) and the mean postoperative SE, -1.66 +/- 0.68 D (range -0.50 to -2.75 D) (P <.05). The mean preoperative UCVA of 0.034 +/- 0.016 increased to 0.35 +/- 0.15 (P <.05) postoperatively. The mean preoperative BSCVA was 0.53 +/- 0.19 and changed to 0.64 +/- 0.16 postoperatively. The safety index was 1.21. No eye lost a line of BSCVA; 9 eyes gained 1 line, and 5 eyes gained 2 lines. The efficacy index was 0.66. The postoperative uncorrected and best spectacle-corrected BV were the same or improved. No eye had +3 haze. There were no significant complications. CONCLUSIONS: Photorefractive keratectomy was safe and effective in correcting high myopic anisometropia in children who were contact-lens intolerant. It provided good visual results and preserved or improved BV over the 4-year follow-up.

Adolescent↗

Transscleral fixation of a foldable intraocular lens in aphakic vitrectomized eyes.

PURPOSE: To evaluate the clinical outcomes of transscleral fixation of a foldable intraocular lens (IOL) in eyes that had pars plana lensectomy combined with pars plana vitrectomy for severe vitreoretinal disease. SETTING: Seoul National University Hospital, Seoul, Korea. METHODS: The medical records of 21 patients who had a transscleral fixation of a foldable IOL after previous vitrectomy combined with lensectomy for severe posterior segment pathology were reviewed. The underlying vitreoretinal diseases were complicated proliferative diabetic retinopathy (n = 9), proliferative vitreoretinopathy (n = 5), traumatic retinal detachment (n = 3), intraocular foreign body (n = 2), and uveitic retinal detachment (n = 2). The postoperative best corrected visual acuity (BCVA) was compared with the preoperative BCVA. Autorefractometry and keratometry measurements and central endothelial cell counts were evaluated 1 day preoperatively and 6 months postoperatively. RESULTS: The mean age of the patients was 54.5 years. The preoperative aphakic period ranged from 2 to 22 months. The visual acuity reached the preoperative BCVA by 2 months after surgery and was better than the preoperative BCVA at 6 months (P =.006) and at the final visit (P =.003). Six months postoperatively, the mean myopic shift by cycloplegic autorefractometry was -1.0 diopter (D) and the mean scalar shift in surgically induced keratometric cylinder, 1.0 D. The mean central corneal endothelial loss at 6 months was 6.7% (range 2.4% to 22.2%). The only vitreoretinal complications were a transient vitreous hemorrhage and a reopened macular hole that was reattached after fluid-gas exchange. CONCLUSION: Transscleral fixation of a foldable IOL was safe and led to favorable visual outcomes in aphakic vitrectomized eyes with previous severe vitreoretinal disease.

Adult↗

Myopic keratomileusis in situ: a preliminary report.

We describe a technique and report a retrospective evaluation of myopic keratomileusis in situ. Surgery was performed on 32 eyes, with a mean follow-up time of 128.7 days (range 90 to 194 days). The average reduction of myopia was 8.48 diopters (D) when measured by refraction and 3.96 D by keratometry (minor axis). A statistically significant Pearson correlation coefficient of 0.49 (P = .01) was found between these two variables. Postoperative mean manifest spherical equivalent was -1.70 D (standard deviation 2.54 D). Mean cylinder correction increased -0.48 D (range -2.25 to 2.00 D). Uncorrected visual acuity improved after surgery in all eyes, but in 14 eyes the best corrected visual acuity diminished. Multiple regression model disclosed a limited predictability of the technique. Complications included diminution of best corrected visual acuity, under- and overcorrections, increase in keratometric astigmatism and cylinder correction, keratitis, delayed corneal epithelialization, interface amorphous deposits, monocular diplopia, interface epithelialization, and opacification. The most frustrating was an elusive postoperative cycloplegic refraction. In our hands, myopic keratomileusis in situ was not a technically safe, precise, and predictable technique for correction of myopia. Further improvement in the technique and equipment may provide better results.

Adult↗

Three year results of refractive keratotomy using the Casebeer System.

PURPOSE: To analyze the results of one surgeon's first refractive keratotomy surgeries. SETTING: The Werblin Center, Princeton, West Virginia. METHODS: The three year results of 241 consecutive surgical procedures (128 patients) using Casebeer nomograms were examined. The average preoperative myopia was -4.07 +/- 1.89 diopters.(D). Two hundred twenty-two eyes were corrected with a goal of emmetropia. Two hundred of 241 eyes (83%) were followed for 3 years; 35 eyes (15%) were followed for fewer than 3 years after the last enhancement procedure, and 6 eyes (2%) were lost to follow-up. RESULTS: At 3 years postoperatively (range 30 to 44 months), excluding postoperative suture and ALK procedures, mean residual manifest refractive error (spherical equivalent) was -0.04 +/- 0.67 D (-2.25 to + 3.13 D). Mean residual cycloplegic error was + 0.45 +/- 0.76 D (-1.00 to + 4.13 D). Eighty-seven eyes (36%) required between one and six enhancement procedures. One hundred fifteen eyes (52%) had 20/20 or better visual acuity and 214 eyes (96%), 20/40 or better. One hundred fifty-two eyes (84%) were within +/- 1.0 D and 120 eyes (66%) were within +/- 0.5 D. Ten eyes (4%) lost one or more lines of best corrected acuity. CONCLUSION: Using the Casebeer system for refractive keratotomy, we obtained 20/40 or better uncorrected visual acuity in 96% of eyes with low to moderate levels of myopia. However, a significant number of enhancement procedures, 36% overall, were required to achieve this level of success. Hyperopic shift remains a significant concern following radial keratotomy procedures.

Adult↗

Recurrent severe hypotony after cataract surgery in an eye with previous trabeculectomy.

This report describes a patient who developed severe recurrent hypotony after uneventful phacoemulsification and intraocular lens (IOL) implantation 4 years after trabeculectomy. Hypotony was first noticed 1 month postoperatively and treated successfully with topical steroids. However, it reappeared 2 months later and slowly subsided only with steroid and cycloplegic treatment. There was no anterior chamber shallowing, leakage, or signs of inflammation. The cause of hypotony in this patient remains unknown. One possible explanation is subclinical postoperative inflammation as a foreign-body reaction to the IOL.

Atropine↗

Laser in situ keratomileus using the LaserSight 200 laser: results of 950 consecutive cases.

PURPOSE: To examine the refractive outcome in 950 consecutive eyes having laser in situ keratomileusis (LASIK) by 1 surgeon with experience in keratomileusis. SETTING: Outpatient excimer laser surgical facility. METHODS: This study comprised 950 consecutive eyes of 475 patients having LASIK as a primary procedure with a LaserSight 200 excimer laser (8.51 software). A nasal hinged flap and a Chiron microkeratome were used. Preoperative cycloplegic refraction was done only in patients younger than 25 years and in all hyperopic cases. Subjective preoperative and postoperative manifest refractions were done after autorefractometry in all cases. In cases of hyperopia, the software was modified by adding 30% to the refractive error. Enhancement results are not included. RESULTS: Of the 950 eyes, 893 (94.00%) were myopic and 57 (6.00%), hyperopic. In the low myopia group (1.00 to 3.99 D) of 223 eyes (24.97%), mean spherical equivalents (SEs) were -2.90 D +/- 0.56 (SD) preoperatively, -0.46 +/- 0.6 D 3 months postoperatively, and -0.41 +/- 0.5 D 6 months postoperatively. In the moderate myopia group (4.00 to 5.99 D) of 205 eyes (22.96%), respective mean SEs were -4.90 +/- 0.7 D, -0.90 D +/- 0.9 D, and -0.67 +/- 0.7 D. In the high myopia group (6.00 to 9.99) of 266 eyes (25.30%), the respective means were -7.70 +/- 1.3 D, -0.76 +/- 0.99 D, and -0.60 +/- 0.8 D. In the extreme myopia group (10.21 to 30.00) of 199 eyes (22.28%), the respective means were -13.30 +/- 2.9 D, -1.30 +/- 1.4 D, and -1.13 +/- 1.3 D. For the entire myopic group, the mean astigmatism was +1.55 +/- 1.38 D, +1.09 +/- 0.92 D, and +0.87 +/- 0.77 D, respectively. The low hyperopia group (1.00 to 2.99 D) of 39 eyes (68.42%) had a mean preoperative SE of +1.80 +/- 0.59 D and mean postoperative SEs of +1.00 +/- 0.76 D at 3 months and +1.16 +/- 0.52 D at 6 months. The respective means in the moderate hyperopia group (3.00 to 6.00) of 18 eyes (31.57%) were +4.62 +/- 1.19 D, +3.71 +/- 1.12 D, and +4.00 +/- 1.07 D. CONCLUSIONS: Laser in situ keratomileus for myopia using the LaserSight 200 excimer laser was stable with time and safe for the correction of different degrees of myopia. In the hyperopic group, marked regression occurred in a large percentage of patients. Thus, we will not perform LASIK for hyperopia until the software improves.

Adult↗

Initial results of photorefractive keratectomy and laser in situ keratomileusis performed by a single surgeon.

PURPOSE: To determine the safety and efficacy of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) early in a surgeon's experience. SETTING: Ophthalmology Department, John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: Between October 1995 and April 1997, a retrospective analysis was performed of 200 eyes in 128 patients who had PRK or LASIK with a follow-up of at least 3 months. The mean age was 38.1 years +/- 10.4 (SD) in the PRK group and 42.3 +/- 10.1 years in the LASIK group. There were 36 women and 30 men in the former and 32 women and 30 men in the latter. Photorefractive keratectomy, PRK/astigmatic keratotomy (AK), LASIK, or LASIK/AK was performed with the Summit Omnimed excimer laser. Preoperative evaluation included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), cycloplegic refraction, tonometry, and computerized videokeratography. At 1, 3, and 6 months, UCVA, BSCVA, mean spherical equivalent (SE), astigmatism, corneal haze, subjective vision (day, night, glare, and halo), and complications were measured. RESULTS: Mean SE was 0.16 +/- 0.82 diopter (D) in the PRK group and -0.09 +/- 0.63 D in the LASIK group at 1 month (P < .05), -0.18 +/- 0.66 D and -0.16 +/- 0.58 D, respectively, at 3 months, and -0.33 +/- 0.73 D and -0.09 +/- 0.62 D, respectively, at 6 months. Achieved correction was similar in the 2 groups. Mean BSCVA was 22.8 +/- 6.0 in the PRK group and 22.2 +/- 5.3 in the LASIK group at 1 month, 21.1 +/- 6.0 and 21.1 +/- 3.1, respectively, at 3 months, and 19.8 +/- 3.5 and 22.9 +/- 5.2, respectively, at 6 months (P < .005). Mean surface regularity index was 0.68 +/- 0.40 in the PRK group and 0.86 +/- 0.41 in the LASIK group at 1 month, 0.54 +/- 0.26 and 0.72 +/- 0.37, respectively, at 3 months (P < .05), and 0.49 +/- 0.27 and 0.84 +/- 0.42, respectively, at 6 months. Mean surface asymmetry index was 0.71 +/- 0.43 in the PRK group and 0.55 +/- 0.21 in the LASIK group at 1 month (P < .05), 0.53 +/- 0.24 and 0.51 +/- 0.23, respectively, at 3 months, and 0.46 +/- 0.19 and 0.64 +/- 0.54, respectively, at 6 months. The subjective parameters between the groups were significantly different only at 6 months; patients in the PRK group reported better day and night vision. CONCLUSION: With careful preparation and proper training, PRK and LASIK appear to be safe and efficacious even during the surgeon's early learning phases.

Adolescent↗