Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “high throughput”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Microfluidic systems for high-throughput and combinatorial chemistry.

Demands on modern combinatorial chemistry have necessitated massive investment in new synthetic technologies that will allow the production of highly pure drug candidates on short timescales. The advent of microfluidic reactor technologies has recently provided a new tool for the combinatorial chemist, offering the promise of ultra-high-throughput solution-phase chemistries. This review describes why such microscale systems provide unique environments for performing high-efficiency molecular synthesis, details some of the most important recent developments in the field and assesses the true applicability of micro-engineered reactors in high-throughput compound synthesis.

Combinatorial Chemistry Techniques↗

Routine use of a simple low-cost genotypic assay for the identification of mycobacteria in a high throughput laboratory.

A novel polymerase chain reaction (PCR)-restriction fragment length polymorphism analysis (PRA) of the hsp65 gene was used for the routine identification of mycobacteria in a high throughput clinical laboratory. A total of 2036 clinical isolates were tested by PRA in conjunction with other methods. The PRA identification of M. tuberculosis complex was 100% sensitive and specific, and 74.5% of nontuberculous mycobacteria (NTM) were correctly identified. It gave highly consistent results for Mycobacterium avium complex (MAC) species and for most isolates of M. fortuitum, M. chelonae, and M. kansasii. It had proven to be highly robust and stable despite usage on such a large-scale and is thus particularly suitable for use in high throughput laboratories in areas with a high incidence of tuberculosis.

Algorithms↗

Determination of monomethylhydrazine with a high-throughput, all-fiber near-infrared spectrometer based on an integrated acoustooptic tunable filter and an erbium-doped fiber amplifier.

A novel integrated acoustooptic tunable filter (IAOTF) has been developed. This tunable filter is based on the Bragg interactions between waveguide and surface acoustic waves. Compared to (bulk) AOTF, its advantage include all-fiber construction, smaller size, narrower spectral resolution (1.7 nm), higher diffraction efficiency (37%), and lower rf power requirement (150 mW). A relatively narrow spectral tuning range (about 80 nm) is the only drawback for this integrated tunable filter. However, this disadvantage was overcome by judiciously using the filter for measurements in which its tuning range is coincident with the light source and also with absorption bands of analytes. In fact, an all-fiber, compact, high-throughput near-infrared spectrophotometer has been successfully constructed by synergistic use of this integrated AOTF and the erbium-doped fiber amplifier (EDFA), which has been shown to provide high intensity and wide spectral band-width in the near-infrared region from 1500 to 1600 nm. This spectral region is particularly useful for the determination of samples which have O-H and/or N-H groups. The all-fiber nature, compactness, high throughput, and high sensitivity of this spectrophotometer make it particularly suitable for on-line and real-time detection of trace gases in hostile environments, including leak detection of monomethylhydrazine (at a limit of detection of 191 ppm), which is often used as the hypergolic propellant for the space shuttle thruster systems.

Acoustics↗

Toward high-throughput synthesis of complex natural product-like compounds in the genomics and proteomics age.

In the age of high-throughput biology, novel genes and proteins are emerging quickly. The need for developing organic synthesis-derived methods that allow rapid access to polyfunctional, complex natural product-like compounds is growing constantly, largely because these small-molecule-based compounds serve as smart, powerful tools both in understanding the roles and functions of emerging biological targets and in validating their biological responses. Developing asymmetric synthesis-derived organic reactions on solid phase allows the synthesis of complex natural product-like compounds in a high-throughput manner. Solid phase organic synthesis is now commonly utilized in the library synthesis of rather simple compounds (i.e., compounds with no multiple stereogenic centers). With few exceptions, the synthesis of complex natural product-like derivatives is still in its infancy. Some recent efforts made in this area indicate opportunities yet to be explored.

Biological Factors↗

ClearDepthIAS enables automated high-throughput quantification of roots in soil-grown taproot crops.

Understanding root system architecture is critical for improving crop productivity and resilience, yet phenotyping root traits such as root growth angle and rooting depth remains technically challenging, especially at high throughput. Here, we present ClearDepthIAS, a high-throughput imaging and analysis platform that enables nondestructive, automated quantification of root architecture traits in taproot system crops. By capturing and stitching 360° images of roots growing along the transparent walls of pots and applying deep learning-based segmentation (ClearDepth-WRT), we measured wall root shallowness (WRS)-a proxy for root growth angle-with high precision. We demonstrated for the tap root systems of soybean and canola that the system accurately detects root tips, quantifies their vertical distribution, and extracts biologically meaningful traits such as root area, distribution indices, and growth angles. Validation experiments in canola and soybean demonstrated that WRS can correlate with root crown architecture in mature plants, both in greenhouse and field settings. Furthermore, WRS and root distribution indices derived from ClearDepthIAS are predictors of early root architecture and can be correlated with root biomass distribution across soil depths under field conditions; however, environmental interactions may influence these relationships and weaken or even negate such correlations, as observed when comparing field to field variation in root system architecture. Our system enables efficient phenotyping of genetically diverse populations, with medium to high trait heritability, supporting its utility for genome-wide association studies and breeding. ClearDepthIAS accelerates the development of root ideotypes for improved resource acquisition and carbon sequestration, offering a scalable tool for supporting climate-resilient agriculture.

Plant Roots↗

A yellow fluorescent protein-based assay for high-throughput screening of glycine and GABAA receptor chloride channels.

There is a significant clinical need to identify novel ligands with high selectivity and potency for GABA(A), GABA(C) and glycine receptor Cl- channels. Two recently developed, yellow fluorescent protein variants (YFP-I152L and YFP-V163S) are highly sensitive to quench by small anions and are thus suited to reporting anionic influx into cells. The aim of this study was to establish the optimal conditions for using these constructs for high-throughput screening of GABA(A), GABA(C) and glycine receptors transiently expressed in HEK293 cells. We found that a 70% fluorescence reduction was achieved by quenching YFP-I152L with a 10 s influx of I- ions, driven by an external I- concentration of at least 50 mM. The fluorescence quench was rapid, with a mean time constant of 3 s. These responses were similar for all anion receptor types studied. We also show the assay is sufficiently sensitive to measure agonist and antagonist concentration-responses using either imaging- or photomultiplier-based detection systems. The robustness, sensitivity and low cost of this assay render it suited for high-throughput screening of transiently expressed anionic ligand-gated channels.

Bacterial Proteins↗

High-throughput mass-spectrometry monitoring for multisubstrate enzymes: determining the kinetic parameters and catalytic activities of glycosyltransferases.

A novel high-throughput screening (HTS) method with electrospray time-of-flight (ESI-TOF) mass spectrometry allows i) rapid and broad screening of multisubstrate enzyme catalytic activity towards a range of donor and acceptor substrates; ii) determination of full multisubstrate kinetic parameters and the binding order of substrates. Two representative glycosyltransferases (GTs, one common, one recently isolated, one O-glycosyltransferase (O-GT), one N-glycosyltransferase (N-GT)) have been used to validate this system: the widely used bovine beta-1,4-galactosyltransferase (EC 2.4.1.22), and the recently isolated Arabidopsis thaliana GT UGT72B1 (EC 2.4.1.-). The GAR (green/amber/red) broad-substrate-specificity screen, which is based on the mass ion abundance of product, provides a fast, high-throughput method for finding potential donors and acceptors from substrate libraries. This was evaluated by using six natural and non-natural donors (alpha-UDP-D-Glucose (UDPGlc), alpha-UDP-N-Acetyl-D-glucosamine (UDPGlcNAc), alpha-UDP-D-5-thioglucose (UDP5SGlc), alpha-GDP-L-fucose (GDPFuc), alpha-GDP-D-mannose (GDPMan), alpha,beta-UDP-D-mannose (UDPMan)) and 32 broad-ranging acceptors (sugars, plant hormones, antibiotics, flavonoids, coumarins, phenylpropanoids and benzoic acids). By using the fast-equilibrium assumption, KM, kcat and KIA were determined for representative substrates, and these values were used to determine substrate binding orders. These screening methods applied to the two very different enzymes revealed some unusual substrate specificities, thus highlighting the utility of broad-ranging substrate screening. For UGT72B1, it was shown that the donor specificity is determined largely by the nucleotide moiety. The method is therefore capable of identifying GT enzymes with usefully broad carbohydrate-transfer ability.

Animals↗

High-throughput characterization and quality control of small-molecule combinatorial libraries.

To fully realize the potential of combinatorial synthesis and high-throughput screening for increasing the efficiency of the drug discovery and development process, issues related to compound purity must be addressed. Impurities, often present after synthesis, can lead to ambiguous screening results and inhibit the development of quality structure-activity relationships. The demand for high-throughput analytical characterization of combinatorial libraries has prompted the development of more rapid methods to keep pace with compound production. Recent progress has focused upon the development of parallel separation methods, multiplexed detector interfaces, and synergistic combinations of different detectors possessing complementary selectivities.

Combinatorial Chemistry Techniques↗

Simple and inexpensive fluorescence-based technique for high-throughput antimalarial drug screening.

Radioisotopic assays involve expense, multistep protocols, equipment, and radioactivity safety requirements which are problematic in high-throughput drug testing. This study reports an alternative, simple, robust, inexpensive, one-step fluorescence assay for use in antimalarial drug screening. Parasite growth is determined by using SYBR Green I, a dye with marked fluorescence enhancement upon contact with Plasmodium DNA. A side-by-side comparison of this fluorescence assay and a standard radioisotopic method was performed by testing known antimalarial agents against Plasmodium falciparum strain D6. Both assay methods were used to determine the effective concentration of drug that resulted in a 50% reduction in the observed counts (EC(50)) after 48 h of parasite growth in the presence of each drug. The EC(50)s of chloroquine, quinine, mefloquine, artemisinin, and 3,6-bis-epsilon-(N,N-diethylamino)-amyloxyxanthone were similar or identical by both techniques. The results obtained with this new fluorescence assay suggest that it may be an ideal method for high-throughput antimalarial drug screening.

Animals↗

Pharmacology of muscarinic acetylcholine receptor subtypes (m1-m5): high throughput assays in mammalian cells.

Based on the ability of many receptors to amplify NIH 3T3 cells, we developed a high throughput assay of cloned receptor pharmacology. In this assay, receptors are transiently co-expressed with the marker enzyme beta-galactosidase. Receptors that induce cellular proliferation select and amplify the cells that also express the marker, thus the ability of ligands to alter receptor activity are reported as changes in enzyme activity. We used this assay to evaluate the pharmacology of agonist and antagonist ligands for five cloned human muscarinic receptor subtypes (m1-m5). When cells were transfected with subtypes that prefer the G-protein Gq (m1, m3, m5) robust increases in enzyme activity were observed. The subtypes that prefer Gi (m2 and m4) only induced beta-galactosidase when co-expressed with a chimera between the G-proteins Gq and Gi (Gq-i5). Overall, the rank-order of potency and intrinsic activity of most of the tested ligands were in remarkably good agreement with earlier results using cloned cell lines and isolated tissues. These data demonstrate that a high throughput colorimetric assay performed in 96-well plates can be used to evaluate subtle differences the pharmacology of ligands for cloned muscarinic receptor subtypes.

Binding, Competitive↗

A high-throughput screen for identifying transmembrane pore-forming peptides.

We have developed a visual microwell plate assay for rapid, high-throughput screening for membrane-disrupting molecules such as de novo designed pore formers, antibiotic peptides, bacterial toxins, and lipases. The detectability is based on the strong fluorescence emission of the lanthanide metal terbium(III) (Tb(3+)) when it interacts with the aromatic chelator dipicolinic acid (DPA). While Tb(3+) is not strongly fluorescent alone, the binary complex emits bright green fluorescence when irradiated with uv light. For the microwell plate assay, we prepared unilamellar phospholipid vesicles that had either Tb(3+) or DPA entrapped and the opposite molecule in the external solution. Disruption of the membranes allows the Tb(3+)/DPA complex to form, giving rise to a visibly fluorescent solution. In plates with 20-microl wells, the lower limit of visual detectability of the Tb(3+)/DPA complex in solution was about 2.5 microM. The lower limit of detectability using vesicles with entrapped Tb(3+) or DPA was about 50 microM phospholipid. We show that the membrane-disrupting effect of as little as 0.25 microM or 5 pmol of the pore-forming, antibiotic peptide alamethicin can be detected visually with this system. This sensitive, high-throughput assay is readily automatable and makes possible the visual screening of combinatorial peptide libraries for members that permeabilize lipid bilayer membranes.

Alamethicin↗

Multiplexed, high-throughput genotyping by single-base extension and end-labeled free-solution electrophoresis.

Technologies that allow for high-throughput, economical, and accurate single nucleotide polymorphism (SNP) genotyping are becoming crucial for modern genomic efforts. Here, we present a method for multiplexed single-base extension (SBE) genotyping that takes advantage of the unique separation modalities made possible via end-labeled free-solution electrophoresis (ELFSE). Three unique SBE oligonucleotide primers, which probe for mutations of clinical importance in the human p53 gene, were covalently conjugated to three unique polypeptoid frictional end labels and mixed together. This primer-polypeptoid conjugate cocktail was then used in a multiplexed SBE reaction followed by free-solution separation in a 96-capillary array electrophoresis (CAE) instrument. The study was designed to demonstrate multiplexed SNP genotyping of several loci in a single reaction and a single subsequent analysis. Further, the electrophoretic analysis was conducted without any viscous polymeric separation media, was complete in less than 10 min, and can be implemented in any capillary or microfluidic electrophoretic system with four-color fluorescent detection capabilities. Multiplexed SBE-ELFSE genotyping analysis resulted in the simultaneous and accurate genotyping of three p53 loci on five different DNA templates in a single reaction set and single CAE analysis. With the implementation of this method in 96 or more capillaries in parallel, high-throughput screening of SNPs will be accessible to a large number of laboratories.

DNA Primers↗

A set of canine interrepeat sequence PCR markers for high-throughput genotyping.

One hundred and sixteen interspersed repetitive DNA sequence (IRS)-PCR markers have been developed and characterized from Canis familiaris for high-throughput filter-based genotyping. We present a detailed analysis of markers produced by amplification using primers directed to the conserved regions of the C. familiaris short interspersed nuclear element (Can-SINE). The majority of IRS-PCR markers developed were moderately to highly polymorphic with mean heterozygosity (HET) and polymorphism information content (PIC) values of approximately 0.6. The HET value for 22.3% of the markers exceeded 0.7. We also demonstrate that sequence variation of Can-SINEs between breeds is significant and also represents a rich source of polymorphisms. Mapping of 73 of the markers to the existing integrated linkage-radiation hybrid map enriches the map as well as establishes the utility of the markers. The significance and utility of this new class of IRS-PCR Can-SINE-based markers for high-throughput genotyping is discussed. This method can also be extended to other species that are currently map-poor but have a sufficiently high density of SINEs to allow IRS-PCR.

Animals↗

Conversion of AFLP bands into high-throughput DNA markers.

The conversion of AFLP bands into polymorphic sequence-tagged-site (STS) markers is necessary for high-throughput genotype scoring. Technical hurdles that must be overcome arise from genome complexity (particularly sequence duplication), from the low-molecular-weight nature of the AFLP bands and from the location of the polymorphism within the AFLP band. We generated six STS markers from ten AFLP bands (four AFLPs were from co-dominant pairs of bands) in soybean (Glycine max). The markers were all linked to one of two loci, rhg1 on linkage group G and Rhg4 on linkage group A2, that confer resistance to the soybean cyst nematode (Heterodera glycines I.). When the polymorphic AFLP band sequence contained a duplicated sequence or could not be converted to a locus-specific STS marker, direct sequencing of BAC clones anchored to a physical map generated locus-specific flanking sequences at the polymorphic locus. When the polymorphism was adjacent to the restriction site used in the AFLP analysis, single primer extension was performed to reconstruct the polymorphism. The six converted AFLP markers represented 996 bp of sequence from alleles of each of two cultivars and identified eight insertions or deletions, two microsatellites and eight single-nucleotide polymorphisms (SNPs). The polymorphic sequences were used to design a non-electrophoretic, fluorometric assay (based on the TaqMan technology) and/or develop electrophoretic STS markers for high-throughput genotype determination during marker-assisted breeding for resistance to cyst nematode. We conclude that the converted AFLP markers contained polymorphism at a 10- to 20-fold higher frequency than expected for adapted soybean cultivars and that the efficiency of AFLP band conversion to STS can be improved using BAC libraries and physical maps. The method provides an efficient tool for SNP and STS discovery suitable for marker-assisted breeding and genomics.

Alleles↗

High-throughput simultaneous determination of plasma water deuterium and 18-oxygen enrichment using a high-temperature conversion elemental analyzer with isotope ratio mass spectrometry.

This paper presents a high-throughput method for the simultaneous determination of deuterium and oxygen-18 (18O) enrichment of water samples isolated from blood. This analytical method enables rapid and simple determination of these enrichments of microgram quantities of water. Water is converted into hydrogen and carbon monoxide gases by the use of a high-temperature conversion elemental analyzer (TC-EA), that are then transferred on-line into the isotope ratio mass spectrometer. Accuracy determined with the standard light Antartic precipitation (SLAP) and Greenland ice sheet precipitation (GISP) is reliable for deuterium and 18O enrichments. The range of linearity is from 0 up to 0.09 atom percent excess (APE, i.e. -78 up to 5725 delta per mil (dpm)) for deuterium enrichment and from 0 up to 0.17 APE (-11 up to 890 dpm) for 18O enrichment. Memory effects do exist but can be avoided by analyzing the biological samples in quintuplet. This method allows the determination of 1440 samples per week, i.e. 288 biological samples per week.

Administration, Oral↗

Rapid, high-throughput extraction of bacterial genomic DNA from selective-enrichment culture media.

AIMS: To create a fast, sensitive and inexpensive high-throughput method for the extraction of bacterial genomic DNA from selective-enrichment culture media. METHODS AND RESULTS: Lysis of bacteria was achieved using guanidinium isothiocyanate, and DNA was extracted using 96-well glass microfibre filtration plates. Extraction-PCR detected the presence of 1 cfu Yersinia ruckeri and 16 cfu Lactococcus garvieae 200 microl(-1) sample of selective-enrichment medium. CONCLUSION: An efficient method for high-throughput extraction of bacterial genomic DNA from selective-enrichment culture media was achieved. SIGNIFICANCE AND IMPACT OF THE STUDY: This method enables detection of covert bacterial infections in fish. The simultaneous extraction of large numbers of samples allows for its use in bacterial monitoring programmes and quarantine.

Bacteria↗

A cell-based cGMP assay useful for ultra-high-throughput screening and identification of modulators of the nitric oxide/cGMP pathway.

We have established a rapid, homogeneous, cell-based, and highly sensitive assay for guanosine 3'-5'-cyclic monophosphate (cGMP) that is suitable for fully automated ultra-high-throughput screening. In this assay system, cGMP production is monitored in living cells via Ca2+ influx through the olfactory cyclic nucleotide-gated cation channel CNGA2, acting as the intracellular cGMP sensor. A stably transfected Chinese hamster ovary (CHO) cell line was generated recombinantly expressing soluble guanylate cyclase, CNGA2, and aequorin as a luminescence indicator for the intracellular calcium concentration. This cell line was used to screen more than 900,000 compounds in an automated ultra-high-throughput screening assay using 1536-well microtiter plates. In this way, we have been able to identify BAY 58-2667, a member of a new class of amino dicarboxylic acids that directly activate soluble guanylate cyclase. The assay system allows the real-time cGMP detection within living cells and makes it possible to screen for activators and inhibitors of enzymes involved in the nitric oxide/cGMP pathway.

Animals↗

High-throughput microarray-based enzyme-linked immunosorbent assay (ELISA).

A new generation biochip is described as capable of supporting high-throughput (HT), multiplexed enzyme-linked immunosorbent assays (ELISAs). These biochips consist of an optically flat, glass plate containing 96 wells formed by an enclosing hydrophobic Teflon mask. The footprint dimensions of each well and the plate precisely match those of a standard microplate. Each well contains four identical 36-element arrays (144 elements per well) comprising 8 different antigens and a marker protein. Arrays are formed by a custom, continuous flow, capillary-based print head attached to a precise, high-speed, X-Y-Z robot. The array printing capacity of a single robot exceeds 20,000 arrays per day. Arrays are quantitatively imaged using a custom, high-resolution, scanning charge-coupled device (CCD) detector with an imaging throughout of 96 arrays every 30 s. Using this new process, arrayed antigens were individually and collectively detected using standard ELISA techniques. Experiments demonstrate that specific multiplex detection of protein antigens arrayed on a glass substrate is feasible. Because of the open microarray architecture, the 96-well microarray format is compatible with automated robotic systems and supports a low-cost, highly parallel assay format. Future applications of this new high-throughput screening (HTS) format include direct cellular protein expression profiling, multiplexed assays for detection of infectious agents and cancer diagnostics.

Adsorption↗