Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “atomic force microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Molecular weights of individual proteins correlate with molecular volumes measured by atomic force microscopy.

Proteins are usually identified by their molecular weights, and atomic force microscopy (AFM) produces images of single molecules in three dimensions. We have used AFM to measure the molecular volumes of a number of proteins and to determine any correlation with their known molecular weights. We used native proteins (the TATA-binding protein Tbp, a fusion protein of glutathione-S-transferase and the renal potassium channel protein ROMK1, the immunoglobulins IgG and IgM, and the vasodilator-stimulated phosphoprotein VASP) and also denatured proteins (the red blood cell proteins actin, Band 3 and spectrin separated by SDS-gel electrophoresis and isolated from nitrocellulose). Proteins studied had molecular weights between 38 and 900 kDa and were imaged attached to a mica substrate. We found that molecular weight increased with an increasing molecular volume (correlation coefficient = 0.994). Thus, the molecular volumes measured with AFM compare well with the calculated volumes of the individual proteins. The degree of resolution achieved (lateral 5 nm, vertical 0.2 nm) depended upon the firm attachment of the proteins to the mica. This was aided by coating the mica with suitable detergent and by imaging using the AFM tapping mode which minimizes any lateral force applied to the protein. We conclude that single (native and denatured) proteins can be imaged by AFM in three dimensions and identified by their specific molecular volumes. This new approach permits detection of the number of monomers of a homomultimeric protein and study of single proteins under physiological conditions at the molecular level.

Anion Exchange Protein 1, Erythrocyte↗

Polysaccharide properties probed with atomic force microscopy.

In recent years, polysaccharides have been extensively studied using atomic force microscopy (AFM). Owing to its high lateral and vertical resolutions and ability to measure interaction forces in liquids at pico- or nano-Newton level, the AFM is an excellent tool for characterizing biopolymers. The first imaging studies showed the morphology of polysaccharides, but gradually more quantitative image analysis techniques were developed as the AFM grew easier to use in aqueous liquids and in non-contact modes. Recently, AFM has been used to stretch polysaccharides and characterize their physicochemical properties by application of appropriate polymer stretching models, using a technique called single-molecule force spectroscopy. From application of such models as the wormlike chain, freely jointed chain, extensible-freely jointed chain, etc., properties such as the contour length, persistence length and segment elasticity or spring constant can be calculated for polysaccharides. The adhesion between polysaccharides and surfaces has been quantified with AFM, and this application is particularly useful for studying polysaccharides on microbial and other types of cells, because their adhesion is controlled by biopolymer characteristics. This review presents a synthesis of the theory and techniques currently in use to probe the physicochemical properties of polysaccharides with AFM.

Animals↗

[Application of atomic force microscopy in the study of morphology of double minute chromosomes].

Atomic force microscopy (AFM) has many advantages in the study of biological samples, such as the convenient specimen preparation and the high resolution. In the present study, AFM was used to observe the double minute chromosomes (DMs) in mouse methotrexate-resistant cell line 3T3R500. AFM images were obtained by tapping mode, contact mode and later force mode of AFM. DMs were composed of two compact spheres connected with fibers. The number of DMs in the 3T3R500 cells increased with increasing levels of methotrexate (MTX) resistance. The data of the height and the underside diameter of the DMs were also obtained. The details of specimen preparation and scan mode selection of AFM were discussed. Our results show that AFM is a powerful method in the study of DMs.

Animals↗

Imaging of the Early Events of Classical Complement Activation Using Antibodies and Atomic Force Microscopy

In the present report we use atomic force microscopy (AFM) combined with antibody techniques to study the lateral distribution of specific serum proteins adsorbed onto flat silicon surfaces precoated with immunoglobulin G (IgG). Null-ellipsometry was used as a complimentary technique to quantify the adsorbed protein layers. After 15 s of incubation in human blood serum a partial monolayer of randomly distributed serum proteins was observed. The following exposure to antibodies to complement factor 1q (anti-C1q) resulted in a development of enlarged protein aggregates and a significant increase in adsorbed mass. Conversely, exposure to antibodies to complement factor 3c (anti-C3c) resulted in only a few randomly distributed protein aggregates and a much smaller increase in adsorbed mass. After 60 s of serum incubation the entire surface was covered with a proteinaceous film with irregular topography. This layer bound large amounts of anti-C3c but showed significantly smaller affinity for anti-C1q. Prolonging the serum incubation to 30 min resulted in an increased thickness and roughness of the protein layer and caused a massive deposition of anti-C3c but no anti-C1q. The results suggests that the transient affinity of anti-C1q, seen on various classically complement activating surfaces, is due to a shielding of the initially adsorbed proteins by subsequently deposited layers of C3. The results also show that qualitative information of the lateral organisation of specific proteins in a heterogeneous mixture can be assessed using AFM in combination with immunological techniques.

Journal Article↗

Material anisotropy revealed by phase contrast in intermittent contact atomic force microscopy.

Phase contrast in intermittent-contact atomic force microscopy (AFM) reveals in-plane structural and mechanical properties of polymer monolayers. This is surprising, because measurements of nanoscale in-plane properties typically require contact mode microscopies. Our measurements are possible because the tip oscillates not just perpendicular but also parallel to the sample surface along the long axis of the cantilever. This lateral tip displacement is virtually universal in AFM, implying that any oscillating-tip AFM technique is sensitive to in-plane material properties.

Journal Article↗

Force and Compliance Measurements on Living Cells Using Atomic Force Microscopy (AFM).

We describe the use of atomic force microscopy (AFM) in studies of cell adhesion and cell compliance. Our studies use the interaction between leukocyte function associated antigen-1 (LFA-1)/intercellular adhesion molecule-1 (ICAM-1) as a model system. The forces required to unbind a single LFA-1/ICAM-1 bond were measured at different loading rates. This data was used to determine the dynamic strength of the LFA-1/ICAM-1 complex and characterize the activation potential that this complex overcomes during its breakage. Force measurements acquired at the multiple- bond level provided insight about the mechanism of cell adhesion. In addition, the AFM was used as a microindenter to determine the mechanical properties of cells. The applications of these methods are described using data from a previous study.

Journal Article↗

[The new measurement technics in biology and medicine--atomic force microscopy].

Scanning probe microscopy (SPM) has recently become the most dynamically developing technique employed in research investigations. Atomic force microscopy (AFM) that uses a digitally-controlled scanner and a cantilever system with a measurement tip shaped as a cone with the apex radius of 2-50 nm and the application force of 10(-10) N, as well as a system of recording detectors, has allowed for identification of numerous biological structures in a nanometer scale. The paper presents a review of measurement methods that employ the atomic force microscopy and are being used in medicine and biology, along with major achievements accomplished owing to this technique by various investigators, including the authors themselves.

Animals↗

A metal-chelating microscopy tip as a new toolbox for single-molecule experiments by atomic force microscopy.

In recent years, the atomic force microscope (AFM) has contributed much to our understanding of the molecular forces involved in various high-affinity receptor-ligand systems. However, a universal anchor system for such measurements is still required. This would open up new possibilities for the study of biological recognition processes and for the establishment of high-throughput screening applications. One such candidate is the N-nitrilo-triacetic acid (NTA)/His-tag system, which is widely used in molecular biology to isolate and purify histidine-tagged fusion proteins. Here the histidine tag acts as a high-affinity recognition site for the NTA chelator. Accordingly, we have investigated the possibility of using this approach in single-molecule force measurements. Using a histidine-peptide as a model system, we have determined the binding force for various metal ions. At a loading rate of 0.5 microm/s, the determined forces varied from 22 +/- 4 to 58 +/- 5 pN. Most importantly, no interaction was detected for Ca(2+) and Mg(2+) up to concentrations of 10 mM. Furthermore, EDTA and a metal ion reloading step demonstrated the reversibility of the approach. Here the molecular interactions were turned off (EDTA) and on (metal reloading) in a switch-like fashion. Our results show that the NTA/His-tag system will expand the "molecular toolboxes" with which receptor-ligand systems can be investigated at the single-molecule level.

Chelating Agents↗

Atomic force microscopy investigation of radiation-induced DNA double strand breaks.

We have used atomic force microscopy (AFM) to study radiation-induced DNA double strand breaks. Double-stranded plasmid DNA was irradiated with 18-MeV electrons in aqueous buffer, using a medical linear accelerator. Doses of 50, 100, 150, and 200 Gy were delivered to DNA samples, and atomic force microscopy was used to measure the length of each DNA fragment. From these measurements, we obtained the average length of the irradiated DNA for each sample and found a linear-quadratic relationship between the average length and radiation dose.

DNA↗

[Detection of immune complexes using atomic force microscopy].

Complex formation between immunoglobulins and ligands immobilized on mica was studied by atomic force microscopy in two different systems. In the first system, 60-kDa ligands possessing only one site for antibody recognition were used. In the other system, a more complex interaction of human immunoglobulin with immobilized polyclonal antibodies was studied. In both systems, specific complexes with proper ligand appeared, and unspecific interaction was not detected. The method of revealing immunocomplexes by image atomic force microscopy can be used in the development of modern diagnostic systems.

Aluminum Silicates↗

Atomic force microscopy imaging of fragments from the Martian meteorite ALH84001.

A combination of scanning electron microscopy (SEM) and environmental scanning electron microscopy (ESEM) techniques, as well as atomic force microscopy (AFM) methods has been used to study fragments of the Martian meteorite ALH84001. Images of the same areas on the meteorite were obtained prior to and following gold/palladium coating by mapping the surface of the fragment using ESEM coupled with energy-dispersive X-ray analysis. Viewing of the fragments demonstrated the presence of structures, previously described as nanofossils by McKay et al. (Search for past life on Mars--possible relic biogenic activity in martian meteorite ALH84001. Science, 1996, pp. 924-930) of NASA who used SEM imaging of gold-coated meteorite samples. Careful imaging of the fragments revealed that the observed structures were not an artefact introduced by the coating procedure.

Carbonates↗

Microstructure of Monoplacophora (Mollusca) shell examined by low-voltage field emission scanning electron and atomic force microscopy.

The shell of Micropilina arntzi (Mollusca: Monoplacophora), a primitive molluscan class, was examined by using field emission scanning electron microscopy (FESEM) at low voltage and atomic force microscopy (AFM). The use of these two techniques allowed the observation of fine details of Micropilina arntzi shell and contributed to bring new features concerning the study of molluscan shell microtexture. Imaging with low-voltage FESEM provided well-defined edge contours of shell structures, while analyzing the sample with AFM gave information about the step height of stacked internal structures as well as the dimension of the particles present in their surface at a nanometric level. The shell microstructure of Monoplacophora species presents different patterns and may be a taxonomic implication in the systematic studies of the group.

Animals↗

Effects of relative humidity and applied force on atomic force microscopy images of the filamentous phage fd.

The filamentous phage fd was studied by both contact- and tapping-mode atomic force microscopy under conditions of controlled variations in relative humidity and changes in the applied tip force. By spin-coating freshly cleaved mica with phage containing solutions having very low salt content followed by rapid humidity control, stable and reliable sample preparation was achieved. The apparent height of the phage varied by about 10-fold with a quadratic dependence on the stabilized relative humidity, extrapolating to 73% of the accepted X-ray diffraction-based height at 0% relative humidity. The variation in measured height with relative humidity largely reconciles previous widely varying atomic force microscopy estimates of this dimension for the filamentous phage. Our finding that contact-mode images of phage are more difficult to analyze than those acquired in tapping mode are consistent with previously published results on other biological specimens such as DNA.

Humidity↗

Structures of large T antigen at the origin of SV40 DNA replication by atomic force microscopy.

For inorganic crystals such as calcite (CaCO3), Atomic Force Microscopy (AFM) has provided surface structure at atomic resolution (Ohnesorge and Binnig, 1993). As part of a broad effort to obtain high resolution for an individual protein or protein assembly (Binnig et al., 1986; Rugar and Hansma, 1990; Radmacher et al., 1992), we applied AFM to study the ATP-dependent double hexamer of SV40 large T antigen, which assembles around the viral origin of DNA replication. Multimeric mass has been determined in two-dimensional projected images by Scanning Transmission Electron Microscopy (STEM) (Mastrangelo et al., 1989). By AFM, if the DNA-protein preparation has been stained positively by uranyl acetate, the contour at the junction between hexamers is visible as a cleft, 2-4 nm deep. The cleft, whether determined as a fraction of height by AFM or as a fraction of mass thickness by STEM, is of comparable magnitude. On either side of the cleft, hexamers attain a maximum height of 13-16 nm. Monomers found in the absence of ATP show heights of 5-7 nm. Taken together, the z coordinates provide a surface profile of complete and partial replication assemblies consistent with the spatial distribution of recognition pentanucleotides on the DNA, and they contribute direct geometrical evidence for a ring-like hexamer structure.

Antigens, Viral, Tumor↗

The effect of deformation on the lateral resolution of atomic force microscopy.

A computer model based on the elastic properties of rubber is introduced for the evaluation of the lateral resolution in atomic force microscopy of deformable specimens. The computational results show that, if the full width at half-height can be defined as the lateral resolution, it is continuously improved at greater probe forces, at the expense of a reduced molecular height, In fact, even for a probe that is bigger than the molecule, the real size of the molecule can be 'recovered' at about 25% compression. This result demonstrates that for a better lateral resolution, a greater probe force can be beneficial, provided that the molecule is not moved or damaged and the response remains elastic. Measurements on isolated low-density lipoproteins (LDL) show that with 26% vertical compression, the lateral size measured in atomic force microscopy is only 72% of the value predicted by a simple convolution, and is only slightly larger (approximately 13%) than the known size of LDL. Therefore, the results on LDL provide a direct support for the conclusions of the computational model.

Computer Simulation↗

Atomic force microscopy study of human amylin (20-29) fibrils.

Here we present atomic force microscopy images of the fibrils formed by human amylin(20-29). This peptide is a fragment of the polypeptide amylin, the major proteinaceous component of amyloid deposits found in cases of type-II diabetes mellitus. Our results demonstrate that the amylin(20-29) peptide fragment forms amyloid-like fibrils that display polymorphic structures. Twisting along the axis of fibrils was often observed in fibrils aged for 6 hours but disappeared in mature fibrils aged for longer time periods.

Amino Acid Sequence↗

Interactions of human von Willebrand factor with a hydrophobic self-assembled monolayer studied by atomic force microscopy.

Human von Willebrand Factor (vWF) was studied by atomic force microscopy under physiologic buffer on a hydrophobic octadecyltrichlorosilane self-assembled monolayer. The self-assembled monolayer deposited on glass was sufficiently smooth (root mean square roughness = 0.25 +/- 0.12 nm) to permit identification of adsorbed vWF. Adhesion of the protein to the hydrophobic substrate was sufficient to allow repeated scanning by the atomic force microscope probe, and images of vWF on a submolecular scale were obtained. The frictional force between the surface and the protein was sufficient to withstand an applied lateral force of 19 nN. This result shows that vWF experiences strong interaction with a hydrophobic surface in aqueous media. Statistical analysis of adsorbed vWF shows that the protein is composed of large globular domains with elliptical cross sections of average dimensions 56 +/- 24 nm (major axis) 26 +/- 19 nm (minor axis), and 2.8 +/- 1.0 nm (height). Further analysis of the major axis dimension shows that the molecular chain of vWF contains two statistically different populations of domain size. However, no sequence order of the different domains within the individual molecule was found. On the basis of our analysis of the globular domains, we present a model describing the three-dimensional structure of vWF protomer adsorbed on a hydrophobic surface in a physiologic solution.

Adsorption↗