Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Suction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

The Stocks suction bullet.

The Stocks suction bullet is a device allowing maintenance of positive pressure ventilation, continuous distending pressure and high inspired oxygen concentrations during tracheal toilet in intubated patients. The effectiveness of this device was studied using an experimental apparatus and a dummy lung to represent neonates being treated with either C.P.A.P. or I.P.P.V. and P.E.E.P. By using appropriate combinations of suction catheter type and size, bullet lumen size, ventilator settings and suction pressure limit, it was possible to maintain during suctioning ventilation peak pressures between 50% and 100% of presuction levels and continuous distending pressures (P.E.E.P. or C.P.A.P.) at or in excess of 80% of presuction levels.

Airway Obstruction↗

The more closed the bypass system the better: a pilot study on the effects of reduction of cardiotomy suction and passive venting on hemostatic activation during on-pump coronary artery bypass grafting.

Cardiac surgery with cardiopulmonary bypass (CPB) leads to a powerful activation of the hemostatic system. We assessed to what extent this activation can be attenuated by comparing three different perfusion regimens for on-pump coronary artery bypass grafting (CABG): 1) use of a closed CPB system with aspiration of blood from the operation field via the cardiotomy suction line and active venting of the heart via a roller pump; 2) use of a closed CPB system avoiding aspiration of blood from the operation field via the cardiotomy suction line, but with active venting of the heart; and 3) use of a closed system, avoidance of aspiration of blood from the operation field via the cardiotomy suction line and with passive venting of the heart into the collapsible venous reservoir. Our data show that avoidance of aspiration of blood via the cardiotomy suction line significantly reduces hemostatic activation during on-pump CABG. However, further attenuation of hemostatic activation can be achieved by further closing the system and minimizing the blood/air interface by passive venting of the heart.

Blood Coagulation↗

Quantitative bacteriology of closed-suction wound drainage in contaminated surgery.

This study was designed to evaluate the predictive value of quantitative bacteriology of closed-suction postoperative wound drainage in identifying the patient likely to develop wound infection as well as its subsequent flora. Forty-one patients undergoing major cancer surgery of the head and neck were studied. Postoperatively, closed-suction wound drainage was cultured, and anaerobic and aerobic bacterial isolates were quantitated. The wound infection rate was 20% (8/41). No trend toward increased rate of wound infection with increased numbers of bacteria colonizing the wound was observed. Additionally, there was no consistent correlation between species of bacteria isolated from closed-suction wound drainage and recovery from subsequent wound infection. Quantitative bacteriology of closed-suction wound drainage after contaminated head and neck cancer surgery does not accurately predict which patients were likely to become infected, or the probable bacteriology of subsequent wound infection.

Chi-Square Distribution↗

Selective left endobronchial suctioning in the intubated patient.

Suctioning of secretions from the left endobronchial tree is frequently necessary but often difficult in intubated patients. We examined the effectiveness of a catheter designed expressly for this purpose. Special curved tip (Bronchitrac-L) suction catheters were fitted with thin, radiopaque tubing to facilitate x-ray visualization. Eight-one attempts at left endobronchial placement were made on 74 stable adult intensive care unit patients. The suction catheter was inserted into the oral endotracheal tube or tracheostomy tube just prior to an x-ray filming of the chest. In 15 of 66 patients, the tip of the oral endotracheal tube was too distal (less than 2 cm above the carina) to allow proper functioning of the catheter. Patients with a properly positioned oral endotracheal tube were analyzed separately and showed 56 percent of the catheters went to the left bronchus. When the head was turned to the left prior to placement, successful left bronchus placement occurred in 65 percent. When the catheter was placed through a tracheostomy tube, 100 percent went into the left bronchus (n = 15). There were no catheter-induced complications in this study. The curved tip catheter is an effective means of suctioning the left bronchial tree in patients with tracheostomy tubes. Its reliability in patients with oral endotracheal tubes is reduced but more effective than current methods.

Bronchi↗

Oro-naso-pharyngeal suction at birth: effects on respiratory adaptation of normal term vaginally born infants.

The effect of oro-naso-pharyngeal suction at birth on pulmonary mechanics is described in a random assigned controlled study of 40 normal term vaginally born infants. Twenty cases had their oro-naso-pharynx suctioned immediately after birth (S Group), whereas 20 were not suctioned in the neonatal period (NS Group). A computerized pneumotachographic system (MECVENT) was used for the assessment of respiratory mechanics (Dynamic Compliance (C. Dyn.) and Total Pulmonary Resistance (R) in inspiration and expiration at 10, 30 and 120 minutes after birth. In both groups the C. Dyn increased during the study period whereas the R decreased, mainly in the initial 30 minutes. No significant differences were observed between S and NS groups for any of the parameters of respiratory mechanics. The results obtained in this study provide no physiological basis to recommend routine airway suction at birth in normal, term, vaginally born infants.

Adaptation, Physiological↗

[Suction-irrigator device for microsurgery: technical note].

A modification of the conventional suction device for microsurgery is described. It consists of a built-in tube in another tube, being the first connected to the suction device and the second to the irrigation. This suction-irrigator device allows to accomplish the suction and irrigation simultaneously and in a precise way.

Equipment Design↗

Underestimation of breast cancer with II-gauge vacuum suction biopsy.

OBJECTIVE: The purpose of this study was to determine the mammographic and histologic features of cancerous lesions underestimated using 11-gauge vacuum suction biopsy. MATERIALS AND METHODS: Retrospective review of 11-gauge vacuum suction biopsy was performed to identify lesions diagnosed as atypical ductal hyperplasia or carcinoma. The histology of the core and surgical specimens was compared. Of 158 cases of cancer, underestimation occurred in 15 (9.5%). The mammographic and histologic features were assessed. RESULTS: Of 15 underestimated cases, six were atypical ductal hyperplasia that proved to be cancer (5 ductal carcinoma in situ and 1 invasive) and nine were ductal carcinoma in situ that proved to have invasion. The underestimation rate for calcifications was 16.3% (14/86) and for masses was 1.6% (1/64) (p = 0.007). Most (5/6) underestimated atypical ductal hyperplasia cases were reported as "markedly atypical," and four of nine underestimated ductal carcinoma in situ cases were reported as "possible invasion." No significant difference was seen in the number of core specimens obtained or the sizes of the lesions for underestimated cases versus accurately diagnosed cases. The percentage of calcifications retrieved was significantly different (p = 0.017). No underestimations were found among cases in which the entire mammographic lesion was removed at vacuum suction biopsy. CONCLUSION: The cancer underestimation rate with vacuum suction biopsy was 9.5%. The underestimation rate for calcifications (16.3%) was significantly higher than that for masses (1.6%) (p = 0.007). The percentage of the lesion removed was an important factor in reducing underestimation, as reflected by the percentage of calcifications retrieved and the instances of complete resolution of the lesion seen on mammography.

Biopsy, Needle↗

T-tube suction drainage and/or prophylactic two-dose metronidazole in abdominal hysterectomy.

The efficacy of a two-dose perioperative course of rectally administered metronidazole and/or suction drainage of the vaginal vault in preventing febrile and infectious morbidity was evaluated in a randomized study of 198 patients undergoing abdominal hysterectomy. When compared with the control values, the incidence of febrile morbidity was significantly reduced (from 49% to 10%, 24.5%, and 10% respectively) in the groups treated with metronidazole, T-tube suction drainage, and a combination of the two prophylactic measures. The incidence of infectious morbidity was significantly reduced by using prophylactic metronidazole alone or in combination with suction drainage, but the reduction was most significant in the group treated with metronidazole alone. In the group managed with suction drainage alone, no reduction in infectious morbidity was found. The rate of postoperative urinary tract infection was significantly lower in the group treated with metronidazole alone as compared with the control group. No side effects of metronidazole were encountered.

Adult↗

Effect of microkeratome suction duration on corneal flap thickness and incision angle.

PURPOSE: To determine the effect of suction duration on corneal flap thickness and incision angle of the cut margin created by a microkeratome in a porcine eye. METHODS: Thirty porcine eyes were randomly assigned to three groups according to different suction duration: group 1 (10 sec), group 2 (35 sec), and group 3 (60 sec). The Hansatome microkeratome with a #160 plate and 8.5-mm-diameter suction ring was used to create a corneal flap with a diameter of 8.5 millimeters. Corneal flap thickness was measured by automated ultrasonic pachymetry, and the incision angle was assessed by measuring the angle of a sagittal section of the cornea using image analysis software. RESULTS: Mean corneal flap thickness in groups 1 (10 sec), 2 (35 sec), and 3 (60 sec) was 87.8 +/- 22.0 microm, 116.0 +/- 7.0 microm, and 127.2 +/- 16.8 microm, respectively. There was a statistically significant difference between groups 1 (10 sec) and 2 (35 sec) (P=.005) and groups 1 and 3 (P=.004). The mean incision angle in groups 1, 2, and 3 was 34.8 +/- 9.0 degrees, 44.4 +/- 16.1 degrees, and 48.24 +/- 15.3 degrees, respectively. A statistically significant difference was found between groups 1 (10 sec) and 2 (35 sec) (P=.044) and groups 1 (10 sec) and 3 (60 sec) (P<.001). CONCLUSION: In laser in situ keratomileusis in porcine eyes, an increase in suction duration resulted in a thicker flap and greater incision angle.

Animals↗

Infection control. Suction waste management in hospitals and nursing homes.

A survey of seven hospitals and 16 nursing homes was conducted to examine the equipment and procedures for handling and disposing of blood and body fluids accumulated by suctioning. In hospitals, it was found that the degree of caution used is greatest in surgery units and declines through OB surgery, recovery, ER, intensive care, cardiac care, nursing and oncology units. The degree of caution when disposing of suction waste is uniformly low in nursing homes. Several recommendations are offered to help prevent contamination from suction waste, and detailed infection control guidelines for safer suction waste disposal are provided.

Asepsis↗

Neonatal respirator allowing simultaneous ventilation and suction.

A new type of respirator for newborns allowing tracheal suction and ventilation simultaneously is presented. Additional characteristics are: a partly disposable air supply system, no apparatus deadspace and with one exception no moving parts. The performance of the respirator under varied conditions of lung mechanics was tested using a pneumatic lung thorax analogue. The procedure of tracheal suction was simulated and the effect on tidal volume and alveolar pressure investigated. Triggervolume and response time were also determined. Analysis shows that the respirator has qualities of flow- and pressure preset ventilators. Tracheal suction during ventilation does not impair the delivery of tidal volume. In mechanical ventilation with PEEP the alveolar pressure remains positive throughout the respiratory cycle despite suction.

Humans↗

[Evaluation of the usefulness of suction drainage in the treatment of nonspecific bone infections monitored with C-reactive protein].

INTRODUCTION: Irrigation suction drainage (ISD) is an additional method in treatment of infected bones. Two liters of saline solution daily with an antibiotic is usually recommended for ISD, although some authors suggest that more fluid should be used without antibiotics, stressing the importance of the mechanical effect. Although the method is nowadays accepted as a routine procedure, the reported results of ISD are based on treatment of a limited number of patients and the only criteria for assessment have been clinical and bacteriologic findings. The aim of this prospective study is to show the importance of the mechanical effect of an increased fluid run and the optimal time necessary for cleaning of the osteomyelitic cavity by follow-up the C-reactive protein (CRP) levels as an indicator of an acute inflammation of the affected bone. METHODS: The prospective study was an open, centralized and randomized clinical investigation including over 105 patients with bone infection treated in the period 1986-1996. Two parameters with possible influence on the CRP levels were determined during investigation: 1. patients were divided in three groups depending on the duration of the irrigation suction drainage (3-6 days, 7-10 days and over 10 days) and 2. quantity of the liquid used for the irrigation suction drainage (two groups: 2000 ml per day and 6000 ml per day). Groups were similar in regard to age, sex, bacteriologic agents, duration of infection, localization and previous operations. C-reactive protein (CRP) is a nonspecific, but extremely sensitive indicator of an acute inflammatory disease. The erythrocyte sedimentation rate is not always a reliable indicator of infection. CRP as a protein of an acute phase appears and disappears quickly. Decreased values are a sign of a healing process used in this study for the estimation of the efficacy of the ISD. The CRP level was controlled semiquantitatively before operation and every third day over three weeks. If the values were below 6 mg/l, the results were classified as negative. RESULTS: There were not significant statistical differences in different groups as far as a preoperative average CRP values were concerned neither in the quantity of employed liquid nor in the duration of the ISD and interaction between these two groups. It was the same on the third postoperative day. The differences appear in the significantly lower average values of the CRP in patients of the second group (6000 ml/day) where the ISD lasted for seven or more days. During further follow up, (6th to 21st day) one can observe a significant statistical difference in average CRP values between the first (2000 ml/day) and second group (6000 ml/day) but there is not difference when the duration and sort of employed liquid is concerned. There is not significant difference in average statistical values of the CRP in blood for interaction of fluid quantity and time of ISD as well. DISCUSSION: The main disadvantage in the function of ISD is nonuniform rinsing of the osteomyelitic cavity. Prolonged ISD has no influence on the clinical result as well as on the average values of the CRP. Starting from the third postoperative day results indicate that the quantity of employed liquid has an important influence on the average level of the CRP, while the duration of ISD is not important. Prolonged ISD can not compensate for an inappropriate surgical intervention because it is only an additional method in the treatment of an osteomyelitic process. CONCLUSION: By observing changes in CRP levels during treatment one can conclude that the efficacy of ISD is based mostly on mechanical rinsing and the removal of debris. This points to the importance of the quantity of fluid employed in irrigation suction drainage. Application of 6000 ml liquid per day without antibiotics during 5-7 days gives opportunity of better rinsing increasing the effect of ISD and reducing the incidence of complications.

Adult↗

Reducing the hypoxemia, bradycardia, and apnea associated with suctioning in low birthweight infants.

Hypoxemia and bradycardia are major complications associated with suctioning the neonate. Apnea has been reported following caregiving during peak hours of activity in a neonatal intensive care unit (NICU). This study determined the incidence of hypoxemia, bradycardia, and apnea associated with the standard suction protocol used in one NICU. None of the 17 low birthweight infants suctioned between the peak caregiving activity hours of 8 and 11 AM exhibited bradycardia or apnea. Eleven of the 17 infants experienced no hypoxemia. Six infants displayed hypoxemia that lasted for less than 3 minutes. None of the infants exhibited bradycardia or apnea in association with this suction protocol. Patterns of escalating blood pressure noted in this study are worrisome because of the increased risk of intraventricular hemorrhage.

Analysis of Variance↗

Effects of expiratory rib cage compression combined with endotracheal suctioning on gas exchange in mechanically ventilated rabbits with induced atelectasis.

INTRODUCTION: In Japan, expiratory rib cage compression (a chest physiotherapy technique) is frequently used with mechanically ventilated patients. It has not been determined whether rib cage compression combined with endotracheal suctioning improves oxygenation, ventilation, and mucus clearance. We evaluated the effects of rib cage compression with and without endotracheal suctioning on P(aO(2)), P(aCO(2)), dynamic compliance of the respiratory system (C(RS)), and mucus clearance in rabbits with induced atelectasis. METHODS: Anesthetized adult rabbits had an 18-gauge catheter placed into the airway, together with a tracheal tube via tracheostoma, and were mechanically ventilated. To create atelectasis, artificial mucus was infused into the airway via the catheter. Each rabbit was randomly assigned to one of 4 groups (= 7 in each): (1) control, (2) received endotracheal suctioning alone, (3) received rib cage compression alone, and (4) received both rib cage compression and endotracheal suctioning. After these interventions, for 30 min, each animal was placed supine without intervention for 120 min. RESULTS: In the groups that received rib cage compression, oxygenation, ventilation, and C.

Animals↗

[In vitro evaluation of lubrication properties of a suction catheter].

BACKGROUND: Lubrication is an important factor for passage of a suction catheter through a tracheal tube. This study was carried out to evaluate the effects of lubricants on resistance against removal of a suction catheter from a tracheal tube in an experimental setting. METHODS: A tracheal tube (I.D. of 7.5mm) was inserted into a mannequin, and the resistance against removal of a suction catheter from the tube was measured. RESULTS: Lubrication was improved by using a lubricant (lidocaine jelly or KY jelly), but there was no difference between the effects of the two lubricants. The use of water as lubricant markedly decreased lubrication. Differences in lubrication depending on the type of tracheal tube used, probably due to differences in coating, were also found. CONCLUSIONS: The use of water as a lubricant is not recommended for tracheal suction.

Catheterization↗

Cost-effectiveness and safety of reusable tracheal suction tubes.

OBJECTIVES: To evaluate whether the repetitive use of disposable tracheal suction tubes is cost-effective and safe over the single use. MATERIAL AND METHOD: The cost intrinsic to the washing, cleaning, re-sterilization by ethylene oxide gas, and processing was determined and compared to the cost generated by disposable tubes. The reused disposable suction tubes were also determined for their properties in physical characters and probable contamination and damages. RESULTS: The evaluation showed that cost from single-use disposable suction tubes (8.66 baht) was cheaper than expenses generated from processing steps for recycling of disposable tubes (9.92 baht). The use of a disposable tube only once should minimize the risks posed by the use of the potentially unsafe reused disposable tubes both to the patients and health care workers. CONCLUSION: Recycling of tracheal suction tubes was neither cost-effective nor safe.

Cost-Benefit Analysis↗

Oronasal communication caused by a denture with suction cup: a case report.

Suction cups, which provide high retention, are not being recommended anymore because of the destructive effect of the negative pressure on the palatal tissues. It is known that dentures with suction cups can cause perforations in the palate. In this case report, an oronasal communication caused by a denture with suction cup in a patient who had previously undergone pleomorphic adenoma excision of the palate is presented. Disadvantages of suction cups are emphasized.

Adenoma, Pleomorphic↗

The efficacy of suction drains after routine total joint arthroplasty.

A prospective study of thirty-eight patients (seventy-six knees) who had had a primary bilateral total knee replacement and twelve patients (twenty-four hips) who had had a primary bilateral total hip replacement was conducted to assess the effect of postoperative suction drainage on wound-healing. A suction drain was placed on each patient's right operative wound, while no drains were used on the left. Otherwise, the same operative technique and method of closure were used in all wounds. Statistical analysis of the results showed no difference between the two sides with regard to the incidences of swelling or persistent drainage. Return of active function of the quadriceps and of range of motion of the knee in patients who had had a total knee replacement was also unaffected by the use of suction drains. We concluded that the routine use of suction drains for wounds is unnecessary after uncomplicated total joint arthroplasty.

Follow-Up Studies↗