Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

A multiresidue analytical method using solid-phase extraction and high-pressure liquid chromatography tandem mass spectrometry to measure pharmaceuticals of different therapeutic classes in urban wastewaters.

An analytical method with two extraction steps has been developed and validated for the simultaneous determination of 30 pharmaceuticals belonging to various therapeutic categories in urban wastewater. The aim was to boost the little available information on drugs' fates in sewage treatment plants (STPs) and in the receiving surface water. Aqueous samples were divided into two aliquots, each extracted by a different solid-phase extraction (SPE) method and analysed by reversed-phase liquid chromatography tandem mass spectrometry (HPLC-MS-MS). Recoveries of the pharmaceuticals were mostly greater than 70% and the overall variability of the method was below 8%. The instrumental quantification limit (IQL) varied between 30 and 400 pg injected, and the limits of quantification (LOQ) were in the low ng/L range. Nineteen pharmaceuticals were detected in concentrations between 0.5 and 2000 ng/L in effluents collected from several STPs in Italy. Atenolol, ciprofloxacin, furosemide, hydrochlorothiazide, ofloxacin, ranitidine and sulphamethoxazole were the most abundant compounds. The present analytical method was useful to check for pharmaceuticals in various Italian STPs and to identify the most abundant compounds.

Chromatography, High Pressure Liquid↗

Determination of low levels of poly(ethylene glycol) 400 in plasma and urine by capillary gas chromatography-selected ion-monitoring mass spectrometry after solid-phase extraction.

A convenient and sensitive method for the quantitative determination of poly(ethylene glycol) 400 in plasma and urine with capillary gas chromatography-mass spectrometry has been developed. The sample preparation involves solid-phase extraction with subsequent derivatization with heptafluorobutyric anhydride, which proved to give the most stable derivative. The derivatization procedure was optimized using experimental design, and different solid-phase extraction columns were evaluated. The limit of quantitation was 1 micromol/l (0.4 microg/ml) for both plasma and urine.

Blood Chemical Analysis↗

Determination of chlorobenzenes in water by solid-phase extraction and gas chromatography-mass spectrometry.

A method is described which permits the trace analysis of 10 chlorobenzenes in aqueous samples. Chlorobenzenes were extracted from water samples by solid-phase extraction with a C18 cartridge and analysis was carried out by gas chromatography-mass spectrometry in the selected-ion monitoring mode. The recovery and precision of the method were evaluated by extraction of spiked reagent-grade water at concentration levels of 0.1, 1.0 and 10.0 micrograms/l. This method was applied to the determination of chlorobenzenes in tap, ground and river water. By preparing 200 ml of environmental water samples, the detection limits of the compounds studied were in the range of 0.010-0.042 microgram/l.

Chlorobenzenes↗

Determination of pharmaceutical residues in waters by solid-phase extraction and large-volume on-line derivatization with gas chromatography-mass spectrometry.

This work presents a modified method to analyze selected pharmaceutical residues (clofibric acid, ibuprofen, carbamazepine, naproxen, ketoprofen and diclofenac) in water samples. Various solid-phase extraction cartridges were investigated. The newly developed Oasis HLB (polystyrene-divinylbenzene-N-vinyl pyrrolidone terpolymer) solid-phase extraction (SPE) cartridge provides the optimal sample extraction results. The analytes were then identified and quantitatively determined by gas chromatography-mass spectrometry (GC-MS) via on-line derivatization in the injection-port using a large-volume (10 microl) sample injection with tetrabutylammonium (TBA) salts. This injection-port derivatization technique provides sensitivity, fast and reproducible results for pharmaceutical residues analysis. Mass spectra of butylated derivatives and tentative fragmentation profiles are proposed. Molecular ions and some characteristic ions were used as the quantitation ions to obtain maximum detection sensitivity and specificity. The quantitation limits of these compounds ranged from 1.0 to 8.0 ng/l in 500 ml tap water samples. Recovery of these residues in spiked various water samples ranged from 50 to 108% while RSD ranged from 1 to 10%. The selected analytes were detected in concentrations of 30 to 420 ng/l in wastewater treatment plant effluent and river water samples.

Drug Residues↗

Multiresidue analysis of cotton defoliant, herbicide, and insecticide residues in water by solid-phase extraction and GC-NPD, GC-MS, and HPLC-diode array detection.

A multiresidue procedure was developed for analysis of cotton pesticide and harvest-aid chemicals in water using solid-phase extraction and analysis by GC-NPD, GC-MS, and HPLC-DAD. Target compounds included the defoliants tribufos, dimethipin, thidiazuron; the herbicide diuron; and the insecticide methyl parathion. Three solid-phase extraction (SPE) media, octadecylsilyl (ODS), graphitized carbon black (GCB), and a divinylbenzene-N-vinyl pyrollidine copolymer (DVBVP), were evaluated. On GCB and ODS, recoveries varied depending on compound type. Recoveries were quantitative for all compounds on DVBVP, ranging from 87 to 115% in spiked deionized water and surface runoff. The method detection limit was less than 0.1 microg L(-)(1). SPE with DVBVP was applied to post-defoliation samples of surface runoff and tile drainage from a cotton research plot and surface runoff from a commercial field. The research plot was defoliated with a tank mixture of dimethipin and thidiazuron, and the commercial field, with tribufos. Dimethipin was detected (1.9-9.6 microg L(-)(1)) in all research plot samples. In the commercial field samples, tribufos concentration ranged from 0.1 to 135 microg L(-)(1). An exponentially decreasing concentration trend was observed with each successive storm event.

Chromatography, Gas↗

Multiresidue pesticide analysis in wines by solid-phase extraction and capillary gas chromatography-mass spectrometric detection with selective ion monitoring.

A method was developed to determine pesticides in wines. The pesticides were extracted from the wine using solid-phase extraction on a polymeric cartridge, and the coextractives were removed with an aminopropyl-MgSO(4) cartridge. Analysis was performed using capillary gas chromatography with electron impact mass spectrometric detection in selective ion monitoring mode (GC-MSD/SIM). Three injections are required to analyze all 153 organohalogen, organonitrogen, organophosphate, and organosulfur pesticides and residues. Pesticides were confirmed by retention times of the target ions and three qualifier-to-target ion ratios. Detection limits for most of the pesticides were less than 0.005 mg/L, and quantitation was determined from approximately 0.01 to 5 mg/L. Spike recoveries were performed by fortifying red and white wines at 0.01 and 0.10 mg/L. At the 0.01 ppm level, the spike recoveries were greater than 70% for 116 and 124 pesticides (out of 153) in red and white wines, respectively, whereas at the higher spike concentration of 0.10 mg/L, the recoveries were greater than 70% for 123 and 128 pesticides in red and white wines, respectively. The recoveries of less than 70% were most likely from pesticide polarity or lability, resulting in the inefficient adsorption of the pesticide to the polymeric sorbent, ineffective elution of the pesticide from the sorbent, or thermal degradation of the pesticide under GC-MSD conditions.

Alanine↗

Determination of minor and trace volatile compounds in wine by solid-phase extraction and gas chromatography with mass spectrometric detection.

A new method for the quantitative determination of important wine odorants has been developed. The wine (50 ml) is extracted in a 200 mg solid-phase extraction (SPE) cartridge filled with Lichrolut-EN resins from Merck. The elution is carried out with 1.3 ml of dichloromethane. These extracts are directly analyzed by GC-Ion Trap-MS without further concentration. Twenty-seven important wine odorants, such as volatile phenols, vanillin derivatives, aliphatic lactones, nor-isoprenoids, minor esters and terpenols, can be quantitatively determined in a single gas chromatography-mass spectrometry (GC-MS) run. The recoveries in the SPE isolation are in good agreement with those expected from the calculation of breakthrough volumes from solid-liquid distribution coefficients and are higher than 90%, except for guaiacol, vanillin, 2,6-dimethoxyphenol and 4-vinylphenol. In most cases, precision is below 10%. Method linearity is satisfactory, with r2 higher than 0.99 in all cases. The analysis of spiked samples has shown that there is good agreement between the real mass of compound added to the wine and that determined by analysis. In all cases detection limits are below the odor detection threshold of the compounds, and the calibrated interval covers the natural range of occurrence of the compounds in wine.

Gas Chromatography-Mass Spectrometry↗

Selective solid-phase extraction of bio- and environmental samples using molecularly imprinted polymers.

Of the many applications of molecular imprinting in analytical separation science, the one with highest potential of soon being used in routine analysis is that of solid-phase extraction. Already several examples of selective pre-concentration of biological and environmental samples have been reported. The interest in imprinted extraction sorbents originates from the high selectivities and affinities obtainable, properties which can be qualitatively and quantitatively pre-determined for a particular analyte and separation by the imprinting process. This review summarises work published on molecular imprinted solid-phase extraction and discusses some imprinted-sorbent specific method development issues.

Chromatography, Gas↗

Solid phase extraction and spectrophotometric determination of trace amounts of thiocyanate in real samples.

A simple, selective and rapid method for solid phase extraction and spectrophotometric determination of thiocyanate using a manganese (III) tetrakis (p-sulfonatophenyl) porphyrin, [Mn (TPPS) OAC] bound to Amberlite IR-400 has been developed. The influence of pH, amount of solid phase, sample matrix, type and amount of eluting agent and flow rates i.e. variables affecting the efficiency of the extraction system were evaluated and conditions of the sample, eluting solution and active phase were optimized. The maximal capacity was found to be as 1.16 microg mL(-1) for 1200 mL. Thiocyanate ions can be eluted quantitatively with 8 mL 0.3 M ferric chloride. The enrichment factor was 150. The linear range of the determination is between 0.4-2.0 microg mL(-1) for preconcentration method with a limit of detection of 2.8 ng mL(-1). The method has been successfully applied for determination of trace amounts of thiocyanate in tap water, saliva sample and a synthetic mixture.

Humans↗

[A double column double pH solid phase extraction and capillary GC/FID method for rapid simultaneous determination of acidic and basic drugs in human plasma].

A capillary gas chromatographic method for the rapid simultaneous identification and quantitation of acidic and basic drugs in human plasma is presented. A special double column solid phase extraction device was designed, in which two X-5 resin columns can extract drugs at different pH. The detection limits for acidic and basic drugs can reach 0.5 microgram.ml-1, while the time needed is only half of that when using commercial solid phase extraction cartridges.

Anesthetics, Local↗

[Solid phase extraction and room temperature phosphorimetry coupling technique and its application].

The principle and application in the environmental analysis of Solid Phase Extraction (SPE) combined with Room Temperature Phosphorescence (RTP) analysis were reviewed. The principle, device, separation modes, operation procedures and application of SPE were commented. The merits and shortages in the operation procedure and quantitative analysis of classic RTP were also summarized. The potential application in the trace sample analysis and the advantage of coupling technique of SPE and RTP were indicated. The sensitivity and selectivity of the coupling technique could be greatly increased because of the strong enrichment ability of the SPE materials and the high selectivity of RTP. So far the technique has been successfully used in the analysis of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzofurans (PClDBFs) in the environmental samples according to their phosphorescence emission after preconcentration on the Whatman 1PS filter paper and C18 or C8 SPE membranes.

Adsorption↗

Liquid chromatographic determination of the macrolide antibiotics roxithromycin and clarithromycin in plasma by automated solid-phase extraction and electrochemical detection.

A liquid chromatographic method for the determination of the macrolide antibiotics, roxithromycin and clarithromycin, in plasma is described. The method is fully automated, employing on-line solid-phase extraction for sample clean-up, using the Prospekt unit. Plasma samples, mixed with internal standard, were injected onto exchangeable CN cartridges. After washing, the compounds were eluted and transferred to a C18 analytical column for separation and electrochemical detection. Clarithromycin was used as internal standard when assaying roxithromycin and vice versa. The recovery of the solid-phase extraction method was 90% and higher, and the relative standard deviation was about 3%. The limit of quantitation was 0.5 mumol/l when 25 microliters of plasma was injected. Comparison with a liquid-liquid extraction method for sample clean-up showed good agreement.

Chromatography, High Pressure Liquid↗

Automated extraction of 11-nor-delta9-tetrahydrocannabinol carboxylic acid from urine samples using the ASPEC XL solid-phase extraction system.

The analysis of 11-nor-delta9-tetrahydrocannabinol-carboxylic acid (THCCOOH, the major metabolite of cannabis) in urine with gas chromatography and mass spectrometry (GC-MS) and solid-phase extraction (SPE) sample preparation is well documented. Automated SPE sample preparation of THCCOOH in urine, although potentially advantageous, is to our knowledge poorly investigated. The objective of the present study was to develop and validate an automated SPE sample-preparation step using ASPEC XL suited for GC-MS confirmation analysis of THCCOOH in urine drug control. The recoveries showed that it was not possible to transfer the protocol for the manual SPE procedure with the vacuum manifold to the ASPEC XL without loss of recovery. Making the sample more lipophilic by adding 1 mL 2-propanol after hydrolysis to the urine sample in order to overcome the problem of surface adsorption of THCCOOH led to an extraction efficiency (77%) comparable to that reached with the vacuum manifold (84%). The reproducibility of the automated SPE procedure was better (coefficient of variation 5%) than that of the manual procedure (coefficient of variation 12%). The limit of detection was 1 ng/mL, and the limit of quantitation was 4 ng/mL. Precision at the 12.5-ng/mL level was as follows: mean, 12.4 and coefficient of variation, 3.0%. Potential carryover was evaluated, but a carryover effect could not be detected. It was concluded that the proposed method is suited for GC-MS confirmation urinalysis of THCCOOH for prisons and detoxification centers.

Dronabinol↗

monitoring activity-dependent peptide release from the CNS using single-bead solid-phase extraction and MALDI TOF MS detection.

To investigate dynamic peptidergic cell-cell communication, single micrometer-sized solid-phase extraction (SPE) beads were used to collect peptides from specific locations of well-characterized neurosecretory structures and even individual neuronal processes for off-line MALDI MS analyses. Peptide binding parameters of single SPE beads, including limits of collection, detection, and saturation capacity, were tested with 14C-labeled cytochrome c as well as with mixtures of multiple neuropeptides (bradykinin, Aplysia acidic peptide 1-20, and insulin). MALDI MS detection of secreted peptides was demonstrated in two well-characterized neurosecretory structures, the rat pituitary gland and single cultured Aplysia bag cell neurons. With cultured cells, precise placement of SPE beads allowed peptide collection from distinct neurites with spatial localization on the order of 200 microm, and SPE beads could be replaced within time frames that allowed analyte collection before and after cell stimulation paradigms. Comparison between pre- and poststimulation peptide profiles in both model systems allowed a directed strategy to determine which compounds were released with neuronal activity. Single SPE bead MALDI MS offers a novel approach to investigate peptide signaling that allows the detection and discovery of unknown intercellular signals secreted from a large variety of biological tissues.

Animals↗

Automated solid-phase extraction method for the determination of atovaquone in plasma and whole blood by rapid high-performance liquid chromatography.

A bioanalytical method for the determination of atovaquone in plasma and whole blood by solid-phase extraction and high-performance liquid chromatography has been developed and validated. A structurally similar internal standard was added and protein was precipitated from plasma and whole blood with acetonitrile before being loaded on to a C8 solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J'Sphere ODS-M80 (150x4.0 mm) column with mobile phase acetonitrile-phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precisions for plasma and whole blood were 2.2% and 1.9% respectively at 12 microM and 6.0% and 5.6% respectively at 0.75 microM. The inter-assay precisions for plasma and whole blood were 1.4% and 2.1% respectively at 12 microM and 4.9% and 3.4% respectively at 0.75 microM. The lower limit of quantification in plasma and whole blood were 150 nM. The limit of detection in plasma and whole blood were 30 nM.

Antiprotozoal Agents↗

Determination of lopinavir and nevirapine by high-performance liquid chromatography after solid-phase extraction: application for the assessment of their transplacental passage at delivery.

An adaptation of the HPLC method previously described for the simultaneous assay of amprenavir, ritonavir, indinavir, saquinavir, nelfinavir and efavirenz after solid-phase extraction is proposed here for the separate analysis of the newer PI lopinavir (LPV) and the NNRTI nevirapine (NVP). After viral inactivation by heat (60 degrees C for 60 min), plasma (600 microl), with clozapine added as internal standard, is diluted 1+1 with phosphate buffer pH 7 and subjected to a solid-phase extraction on a C(18) cartridge. Matrix components are eliminated with 2 x 500 microl of a solution of 0.1% H(3)PO(4) neutralised with NaOH to pH 7. LPV and NVP are eluted with 3 x 500 microl MeOH. The resulting eluate is evaporated under nitrogen at room temperature and is reconstituted in 100 microl MeOH 50%. A 40-microl volume is injected onto a Nucleosil 100, 5 microm C(18) AB column. LPV and NVP are analysed separately using a gradient elution program with solvents constituted of MeCN and phosphate buffer adjusted to pH 5.07 and containing 0.02% sodium heptanesulfonate. LPV and NVP are detected by UV at 201 and 282 nm, respectively. The calibration curves are linear up to 10 microg/ml. The mean absolute recovery of LPV and NVP is 91% and 88%, respectively. The method is precise with mean inter-day C.V.s within 2.1-6.6% and 0.9-1.7% for LPV and NVP, and accurate (range of inter-day deviations -1.1 to +2.4%, and -1.9 to +0.8%, for LPV and NVP, respectively). The method has been validated and is currently applied to the monitoring of LPV and NVP in HIV patients, and has been notably applied in a study aimed at assessing the extent of transplacental passage of nevirapine and PIs, notably lopinavir, at the time of delivery in pregnant HIV-infected women.

Calibration↗

Rapid determination of methotrexate in plasma by high-performance liquid chromatography with on-line solid-phase extraction and automated precolumn derivatization.

A high-performance liquid chromatographic system, combining solid-phase extraction and automated precolumn derivatization is described for the routine determination of methotrexate in human plasma. The sample extraction and elution onto the analytical column were performed automatically and concomitantly using the column-switching technique and a protein-coated precolumn. Cerium (IV) trihydroxyhydroperoxide (CTH) was introduced as a packed oxidant before the analytical column for the conversion of methotrexate into highly fluorescent products. The oxidative-cleavage of methotrexate occurs during the flow of 0.04 M phosphate buffer (pH 3.5) containing plasma sample through CTH column with a flow rate of 0.5 mL/min at 40 degrees C. The fluorescent products were transferred to the protein-coated precolumn, which was then flushed with the same buffer for clean-up and enrichment from plasma sample. The trapped substances were desorbed from the precolumn and eluted onto the ODS/TM analytical column by isocratical elution with a mobile phase containing 0.05 M phosphate buffer, pH 6.6 and acetonitrile (90-10, v/v) for subsequent separation. The fluorescent products were detected fluorimetrically at excitation and emission wavelengths of 367 and 463 nm, respectively. The complete analysis was achieved within 15 min per sample. The calibration graph was linear in the range of 50-500 ng/mL of methotrexate and there was no interference from endogenous components.

Antimetabolites, Antineoplastic↗

Automated solid-phase extraction with high-performance liquid chromatography analysis of pyridinium crosslinks.

An automated solid-phase extraction procedure for free and total pyridinium crosslinks in urine, with on-line HPLC analysis, is described. The pyridinium crosslinks either following hydrolysis in 3 M HCl or free in urine were extracted using a Gilson Aspec system onto extraction cartridges containing an octasilane/cation-exchanger sorbent. After washing, the crosslinks were eluted with 400 microl 100 mM sodium formate, pH 5, and 50 microl was automatically injected onto the analytical HPLC column. Detection was by fluorescence (Ex 295 nm, Em 400 nm). Recoveries were 95-100% with a limit of quantitation (s/n = 5) of 1.97 nmol/liter (nM) for pyridinoline and 2.79 nM for deoxypyridinoline. The interassay coefficient of variation was 6.5% for pyridinoline and 8.2% for deoxypyridinoline. The throughput of the system was up to 70 samples per day. The method correlated well with the established manual cellulose extraction but was substantially simpler and more reliable. A good correlation with an immunoassay for deoxypyridinoline was also obtained.

Amino Acids↗