Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sample pretreatment”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Determination of Cr3+, CrO42-, and Cr2O72- in environmental matrixes by high-performance liquid chromatography with diode-array detection (HPLC-DAD).

A high-performance liquid chromatographic method with diode array detection (HPLC-DAD), based on chelation with ammonium pyrrolidinedithiocarbamate (APDC), has been developed for the determination of chromium species. Determination of Cr3+, CrO42-, and Cr2O72- was performed for standards and synthetic environmental matrixes. This method is robust, rugged, and can be used for rapid routine determination of chromium species with high precision and reliability. Sample pretreatment is simple. The method is capable of discriminating not only between Cr(III) and Cr(VI) but also between the chemical forms of Cr(VI) - CrO42- and Cr2O72-. By analysis of numerous samples the method has been shown to be selective, sensitive, and free from matrix interference, which is crucial for the determination of chromium species in difficult-to-analyze environmental matrixes. This method has been validated by means of an interlaboratory study. Although different speciation techniques were used during this study, there was good agreement between results from the two laboratories. The method detection limits were 7 and 4 mg L(-1) for Cr3+ and Cr2O72-, respectively. Recoveries of the analytes from spiked samples were 98% and 100% for Cr3+ and Cr2O72-, respectively. Both were based on a 10-mL sample volume spiked with 0.4 mg L(-1) chromium.

Chromates↗

The routine profiling of forensic heroin samples.

A method for the routine profiling of illicit heroin samples received in casework has been developed which depends on simple and straightforward sample pretreatment, followed by gas chromatography on a capillary column using flame-ionization detection. The factors affecting the choice of each aspect of the procedure are discussed, as are the statistical data for sampling and the chromatography. Components of illicit heroin derived from opium and other adulterants have been identified. The significance of data from samples examined in 1986 is discussed.

Chromatography, Gas↗

Single-step enantioselective amino acid flux analysis by capillary electrophoresis using on-line sample preconcentration with chemical derivatization.

Capillary electrophoresis (CE) represents a versatile platform for integrating sample pretreatment with chemical analysis because of its ability to tune analyte electromigration and band dispersion properties in discontinuous electrolyte systems. In this article, a single-step method that combines on-line sample preconcentration with in-capillary chemical derivatization is developed for rapid, sensitive, and enantioselective analysis of micromolar levels of amino acids that lack intrinsic chromophores by CE with UV detection. Time-resolved electrophoretic studies revealed two distinct stages of amino acid band narrowing within the original long sample injection plug occurring both prior to and after in-capillary labeling via zone passing by ortho-phthalaldehyde/N-acetyl l-cysteine (OPA/NAC). This technique enabled direct analysis of d-amino acids in a 95% enantiomeric excess mixture with sub-micromolar detection limits and minimal sample handling, where the capillary functions as a preconcentrator, microreactor, and chiral selector. On-line sample preconcentration with chemical derivatization CE (SPCD-CE) was applied to study the enantioselective amino acid flux in Escherichia coli bacteria cultures, which demonstrated a unique l-Ala efflux into the extracellular medium. New strategies for high-throughput analyses of low-abundance metabolites are important for understanding fundamental physiological processes in bacteria required for screening the efficacy of new classes of antibiotics as well as altered metabolism in genetically modified mutant strains.

Acetylcysteine↗

Automatic screening in postmortem toxicology.

The systematic analysis of postmortem samples is one of the most challenging tasks in forensic toxicology. For determining cause of death, analysis of different tissues can be indispensable. Automation of these analyses would increase reproducibility and therefore lead to more reliable and comparable results. Recent developments in analytical toxicology and the availability of automation devices for various analytical stages, such as sampling, preliminary testing, sample extraction, chromatographic separation, identification, and data processing are examined and discussed. At present only parts of the analytical procedure have been automated-however, the goal should be the integration of these parts into a single, continuous process. Currently, only one "fully-automated" procedure for the comprehensive screening of blood and urine (excluding sample pretreatment, which remains separate) has been published. But it can be expected that automation of analytical procedures in forensic toxicology will indeed progress, even with regard to the very complex screening of postmortem samples.

Chromatography, Liquid↗

Monitoring of ampicillin and its related substances by NMR.

A 1H NMR procedure for the monitoring of ampicillin (Amp) and its main related substance in different media, has been developed. The characteristics peak of Amp, 6-aminopenicillanic acid (6-APA), phenylglycine (PhG), and penicilloic acid in the range of 0.5-0.9 and 3.0-4.5 ppm were used for their identification in drugs and serum samples. The quantitative works were performed based on the intensity of protons of the methyl group link to the beta-lactam cyclic of Amp and 6-APA and the aromatic protons of PhG relative to the protons of methylene group of maleic acid, as internal standard, at constant temperature. The resulting data are compared with those obtained with an HPLC method proposed by British Pharmacopoeia. Statistical studies show that, at a confidence limit of %95, there is no significant difference between the two methods. In comparison with the HPLC method, the proposed NMR method does not require any sample pretreatment, standard solution preparation, long analysis time and use of any carcinogenic solvent. The method was applied to the determination of Amp and its related substances in synthetic mixtures, drug powders and serum samples.

Ampicillin↗

Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique.

A robust and simple approach for microfluidic liquid-liquid (L-L) extraction at the subnanoliter-scale was developed for on-chip sample pretreatment. Organic solvent droplets of a few hundred pL were trapped within micro recesses fabricated in the channel walls of a microfabricated glass chip. L-L extraction was performed by delivering aqueous samples through the channel, with the sample stream continuously flowing adjacent to the droplets. The analytes in aqueous streams were enriched within the droplet with high preconcentration factors owing to both phase transfer and dissolution of organic solvent into the bypassing aqueous sample. An aqueous solution of butyl rhodamine B (BRB) and 1-hexanol were used, respectively, as sample and extractant to demonstrate the performance of the system. The fluorescence intensity of the dye extracted into the droplet was monitored in situ by LIF. The system proved to be an efficient means for achieving high enrichment factors of over 1000, with sample consumption of a few microL. Quantitative measurement of the extracted analyte was achieved with a linear response in the range 1 x 10(-9)-8 x 10(-7) M BRB. The precision of the measured fluorescence values for a 10(-7) M BRB standard with a 12.5 min preconcentration period was 6.6% RSD (n = 5).

Journal Article↗

Selective protein removal and desalting using microchip CE.

This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100 mM NaCl. However, ITP-CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE-CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.

Animals↗

Dialysis-solid-phase extraction combined on-line with non-aqueous capillary electrophoresis for improved detectability of tricyclic antidepressants in biological samples.

Dialysis-solid-phase extraction (SPE) sample pretreatment is combined on-line with non-aqueous capillary electrophoresis for the determination of tricyclic antidepressants in urine and serum. After clean-up and enrichment, the water is removed from the sample matrix and the analytes are eluted from the cartridge by means of an organic solvent. Next, the eluate is transported to the capillary and the injection is performed electrokinetically. This injection, which does not suffer from an adverse sample matrix effect because of the SPE step, results in further analyte concentration. The detection limits are in the 0.02-0.1 microg/ml range and the day-to-day repeatabilities are between 2.5 and 9.5%, which is quite satisfactory.

Antidepressive Agents, Tricyclic↗

Determination of the enantiomeric composition of gamma-lactones in edible oils by on-line coupled high performance liquid chromatography and gas chromatography.

A new method is proposed for the determination of the enantiomeric composition of gamma-lactones in different vegetable edible oils (i. e., olive oil, almond oil, hazelnut oil, peanut oil, and walnut oil), and its potential for authenticity control is underlined for a limited number of samples. The method is based on the direct injection (i.e., without requiring a sample pretreatment step) in on-line coupled reversed phase liquid chromatography to gas chromatography (RPLC-GC) using a chiral stationary phase in the GC-step. Different experimental values for both speed of sample introduction into GC and volume of the transferred fraction are considered to improve the recoveries obtained. Relative standard deviations lower than 10% and detection limits ranging from 0.06 to 0.22 mg/L were achieved for the investigated gamma-lactones.

Chromatography, High Pressure Liquid↗

On-line pretreatment and determination of Pb, Cu and Cd at the microgram l-1 level in drinking water by chelation ion chromatography.

A novel, highly sensitive method for the simultaneous separation and determination of lead, copper, cadmium and other transition metals in drinking water was achieved by on-line sample pretreatment of chelation ion chromatography. Manganese, which coeluted with cadmium, was oxidized to permanganate by ammonium persulfate before injection. Permanganate, with bulk quantity of alkali, alkaline earth metals, iron and aluminum, was eliminated by pyrophosphoric acid-ammonium acetate buffer solution (pH 5.5), while retaining heavy and transition metals on a selective chelating resin (MetPac CC-1 column). Then, they were disabsorbed and transferred to a sulfonated cation exchanger (TMC-1 column). Finally, the concentrated trace metals were separated on a bifunctional ion-exchange column (CS5A) by a concentration gradient of oxalic acid and sodium nitrate eluents, coupled with post-column spectrophotometric detection with 2-[(5-bromo-2-pyridyl)azo]-5-diethylaminophenol (5-Br-PADAP) at 560 nm. The separation and color-development conditions were optimized. The detection limits for the method (signal-to-noise ratio = 3:1) were at or below the microgram l-1 level. The results of drinking water analyses were satisfactory.

Cadmium↗

Determination of trace level bromate in drinking water by direct injection ion chromatography.

Disinfection byproduct anions such as bromate, chlorite and chlorate pose significant health risks, even at low microgram/l levels in drinking water. A direct injection, ion chromatographic method was developed using a Dionex AS9-HC anion-exchange column with a carbonate eluent and suppressed conductivity detection for the determination of these disinfection byproduct anions, and bromide, at low microgram/l levels in drinking water. No additional sample pretreatment, other than filtration, is required. The method is linear for the oxyhalides and bromide over the typical concentration range expected for these analytes in drinking water; and quantitative recoveries were obtained for drinking water samples spiked at 10 micrograms/l. This ion chromatographic method, based on the recently developed AS9-HC column, is applicable for the quantitation of bromate in finished drinking water at the 10 micrograms/l maximum contaminant level currently being proposed by the US EPA.

Bromates↗

Determination of methamphetamine and its metabolites incorporated in hair by column-switching liquid chromatography-mass spectrometry.

An automated column-switching liquid chromatographic-electrospray ionization-mass spectrometric (LC-ESI-MS) method has been established for the determination of methamphetamine (MA) and its metabolites, amphetamine (AP), and p-hydroxymethamphetamine (p-OH-MA) in hair. The combination of an N-vinylacetamide-containing hydrophilic polymer online extraction column, an SCX semi-micro LC column, and an electrospray ionization interface provided the successful concentration, separations, and highly sensitive MS determinations of these analytes in a hair extract without tedious sample pretreatments. The limits of detection of these analytes were 0.02 ng/mg and 0.1-0.2 ng/mg in the selected-ion monitoring (SIM) and full-scan modes, respectively, when using a 100-microL hair extract sample that corresponds to a 2.5-mg sample of hair. The calibration curves using dibenzylamine as an internal standard were linear up to 30 ng/mg hair equivalents for all these analytes in the SIM mode. p-OH-MA, the detection of which in MA users' hair had not been previously reported, was detectable in all 22 hair specimens/sections from which 1 ng or more of MA was detected per milligram hair. The amount of p-OH-MA detected per milligram of hair is presented with those of MA and AP among the MA users population. The detection of AP and p-OH-MA, in addition to the parent drug MA with reasonable ratios, was found to be a useful indicator for distinguishing internal MA incorporation from external contamination.

Amphetamine↗

Capillary electrophoresis for rapid profiling of organic acidurias.

Organic acids analysis is a powerful technique in the diagnosis of inborn errors of metabolism. Clinically, patients present with severe symptoms, and early detection and appropriate treatment are often lifesaving. Most of the existing methods are based on gas chromatography in combination with mass spectrometry and require sophisticated equipment and complex sample pretreatment and derivatization. We propose a rapid, simple, and automated capillary electrophoretic method for routine analysis of urine to detect 27 organic acids related to metabolic diseases. With this method, direct measurements are performed on samples after initial centrifugation and dilution, if needed. Separation is performed in pH 6.0 phosphate buffer with methanol added as an organic modifier, -10 kV applied potential, and ultraviolet detection at 200 nm. The assay is completed in <15 min, and alternative separation conditions are proposed in case of overlapping peaks. The developed method allows the identification and quantitation of methylmalonic, pyroglutamic, and glutaric acids in samples of patients with diseases related to these acids.

Carboxylic Acids↗

Determination of the metabolites of mexiletine in human plasma.

A liquid chromatographic method for the determination of mexiletine and unconjugated metabolites in plasma has been developed. A reversed-phase C18 column is used with isocratic elution and either UV or amperometric detection. Sample pretreatment involves double extraction of the metabolites. The method enables the measurement of four mexiletine metabolites at levels as low as 10 ng ml(-1), with both precision and accuracy of about 6%. Forty-nine samples from patients receiving mexiletine were analysed. Metabolite VII was found to be the major metabolite (mean concentration 225 ng ml(-1)), metabolites IX and VI were also found at mean concentrations of 95 and 10 ng ml(-1), respectively, whilst metabolite VIII was not detected.

Journal Article↗

At-line solid-phase extraction for capillary electrophoresis: application to negatively charged solutes.

The analysis of complex biological samples with capillary electrophoresis (CE) requires proper sample pretreatment. In this paper the applicability of solid-phase extraction (SPE) coupled at-line with CE is studied, by using a laboratory-made interface. A fresh (disposable) SPE cartridge is used for each sample to prevent carry-over effects. The sample handling procedure is performed parallel with the analysis of the previous sample, to improve sample throughput. Using this set-up, negatively charged test compounds (some non-steroid anti-inflammatory drugs) can be determined in serum and urine. The method is linear over at least two decades and detection limits are around 40 microg/l. A single capillary, flushed only once a week with a sodium hydroxide solution, was used without problems for the analysis of ca. 900 samples during 1 year. The robustness of the system was very good: no blocking of loop, interface or capillary was found during this period. Furthermore, the system was successfully used for overnight runs.

Anti-Inflammatory Agents, Non-Steroidal↗

Rapid and sensitive method for prenatal diagnosis of propionic acidemia using stable isotope dilution gas chromatography-mass spectrometry and urease pretreatment.

Propionic acidemia is one of the most frequent inborn errors of metabolism caused by a deficiency of propionyl-CoA carboxylase. Methylcitric acid, a key indicator of this disorder, is increased in amniotic fluid when a fetus is affected. Therefore, the direct chemical analysis of cell-free amniotic fluid for methylcitric acid, using stable isotope dilution gas chromatography-mass spectrometry, was carried out for the prenatal diagnosis of propionic acidemia. We developed a simple, highly sensitive, and accurate method for quantitation of this polar methylcitric acid in amniotic fluids by applying a simplified urease pretreatment which we devised earlier for urine. As the recovery of methylcitric acid from amniotic fluid was as high as 91% with a coefficient of variation lower than 3% in this procedure, only 0.02 ml of sample was required for the analysis of the affected fetus. This new procedure takes 1 h for sample pretreatment, including derivatization, and 15 min for GC-MS measurement and provides final results within 1.5 h.

Amniotic Fluid↗

[Determination of trace Rh in organic residue by flame atomic absorption spectrophotometry].

The catalytic organic residue contained Rh was digested with HNO3 at 130 degrees C for 12 h. Trace noble metal Rh in catalytic organic residue was determined by flame atomic absorption spectrophotometry. Rh was atomized by air-acetylene flame at lamp Current of 7 mA. The methods of sample pretreatment for Rh in residue were compared in this paper. The recovery rates of this method were 95.3%-105.5% and the relative standard derivation was 0.9%. The method was applied to the analysis of some practical samples and the results obtained were satisfactory.

Acetylene↗

Concentration determination of a recombinant vaccine antigen adsorbed onto an alum adjuvant by chemiluminescent nitrogen detection.

PURPOSE: A chemiluminescent nitrogen detector (CLND) has been evaluated for determining the concentration of an aluminum-adsorbed recombinant vaccine antigen. METHODS: Quantification of the antigen was based upon several nitrogen-containing compounds used to calibrate the CLND. All calibrants (6.75-400 microg/ml) generated linear standard curves, with slopes being directly proportional to the % nitrogen. The limit of quantification (LOQ) was determined to be 6.75 microg/ml based on the performance of the antigen standard curve, and the limit of detection (LOD) was defined by setting the CLND minimum peak area to 40,000 U. The CLND was capable of analyzing antigen-adjuvant suspensions (adsorbed + unbound antigen) without any sample pretreatment. To measure unbound antigen, the suspension was centrifuged and an aliquot of supernatant removed for analysis; the difference between these two measurements was the amount of adsorbed antigen. RESULTS: The adjuvant exhibited no significant matrix effect. Samples were analyzed in triplicate with observed relative standard deviation values ranging from 0.065% to 10.0%. The most accurate concentrations of the antigen were recovered relative to the antigen itself and to glycine as standards. CONCLUSION: This methodology provides a direct measurement of the concentration of a vaccine antigen adsorbed onto an aluminum adjuvant.

Adjuvants, Pharmaceutic↗