Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Ultrasound versus radiography in the detection of soft-tissue foreign bodies.

STUDY OBJECTIVE: To determine the usefulness of ultrasound and radiography in detecting foreign bodies in soft-tissue models closely duplicating puncture-wound trauma and hand anatomy. METHODS: In this randomized, blinded descriptive study, two radiologists independently evaluated 120 chicken thighs for foreign bodies with the use of standard two-view radiography and 7.5-MHz transducer ultrasonography. All chicken thighs were manipulated with hemostats to ensure uniform tissue damage. In 60 thighs, one foreign body had been inserted (10 each: gravel, metal, glass, cactus spine, wood, and plastic). RESULTS: The sensitivity of ultrasound in detecting gravel was 40%, that for metal was 45%, that for glass was 50%, that for cactus spine was 30%, that for wood was 50%, and that for plastic was 40%. The overall sensitivity, specificity, and false-negative and false-positive rates for ultrasound were 43%, 70%, 50%, and 30%, respectively. No individual foreign body had an ultrasound detection rate of 50%. Radiography detected foreign bodies generally considered radiopaque (gravel, glass, metal) 98% of the time, but it never detected bodies considered radiolucent (wood, plastic, cactus spine). The false-negative and false-positive rates for radiography were 50% and 1.6%, respectively. CONCLUSION: Ultrasound detection of foreign bodies by skilled operators in this animal model revealed poor sensitivity and specificity. Radiographic detection was highly sensitive for foreign bodies considered radiopaque. Our data suggest that ultrasound should not be relied on to rule out the possibility of a retained foreign body in the distal extremities.

Animals↗

Chest radiography and thoracic computed tomography findings in children who have family members with active pulmonary tuberculosis.

OBJECTIVE: The chest radiography and TCT findings in children who had contacted with adult family members with active pulmonary tuberculosis were compared. The contributions of thoracic computed tomography to the diagnosis of tuberculosis were investigated. METHODS AND MATERIAL: The children who were 0-16 years old (n=173) and children of families with an adult member which was diagnosed as pulmonary tuberculosis were evaluated. The children were considered in two groups based on the absence (n=125) or presence (n=48) of complaints and/or ambiguous symptoms such as lack of appetite, mild cough, sweating, history of lung infection, low body weight and those with suspicious chest radiography findings (12 cases) were included in this study. Asymptomatic patients (n=125) did not undergo TCT. Patients who had positive PPD skin tests only received isoniazid. If the TCT demonstrated enlarged lymph nodes or parenchymal lesions, minimally active pulmonary tuberculosis was diagnosed and antituberculous treatment was given. RESULTS AND DISCUSSIONS: TCT revealed lymph node enlargement or parenchymal lesions in 39 children (81.2%). Of the 12 children whose CXRs revealed suspicious lymph node enlargement and/or infiltration, five had normal findings in TCT whereas the initial findings were confirmed in the remaining seven. These data suggest that there is a correlation between the presence of ambiguous symptoms in exposed children and TCT findings; chest radiography and TCT findings do not yield parallel findings. All the patients who received anti-TB treatment were resolved in the control examinations. CONCLUSION: In this study there is a correlation between presence of ambiguous symptoms and TCT findings, but the chest radiography and TCT findings do not yield harmony in exposed children with ambiguous symptoms (suspicious tuberculosis cases). These observations should be considered in children with symptoms similar to those of exposed children, but with no definite history of exposure. If similar TCT findings observed in such patients, treatment for tuberculosis should be considered.

Adolescent↗

Clinical applications of radiography and ancillary imaging.

Radiography will remain the most popular imaging modality in the near future for many reasons. It is economical, portable, and familiar to large animal practitioners. Contrast radiography allows evaluation of vascular and tract lesions. Other modalities may offer various advantages. Diagnostic sonography has the advantage of being able to evaluate soft tissue structure damage, fluid pockets, and lucent foreign bodies. Xeroradiography and CR use conventional, high-powered x-ray units for the production of images on nontraditional ionized film plate-cassette systems. Both systems provide superior bone-soft tissue contrast, by virtue of edge enhancement, than does conventional radiography. CT and MR imaging provide cross-sectional imaging of bones and adjacent structures, avoiding structures that may be superimposed on the area of interest with conventional radiography. The major limitation is the demand for a custom-engineered couch able to withstand the weight of an adult bovine. Scintigraphy provides important functional information for the clinical evaluation of orthopedic disease. It may be the most useful imaging tool to localize the cause of lameness.

Animals↗

Observer differentiation of proximal enamel mechanical defects versus natural proximal dental caries with computed dental radiography.

OBJECTIVES: Various models have been used to study the accuracy of imaging systems for detection of dental caries. This study compares the ability of dentists to detect mechanically created defects versus natural dental caries cavitations on the proximal surfaces of extracted teeth with Computed Dental Radiography (Schick Industries, Long Island City, N.Y.). Detection rates are investigated according to lesion depth to permit comparisons to be made between studies in the literature with other mechanical defects or natural caries models. Discrimination of natural caries versus artificial defects with Computed Dental Radiography is also compared with a previous report that used standard dental film. STUDY DESIGN: Fifty-two extracted molar and premolar teeth were mounted into representative sets of maxillary and mandibular posterior arches for bite-wing radiography. There were 16 proximal surfaces with natural caries and 28 proximal surfaces with mechanical defects. An optical bench was used to ensure constant beam geometry. A 1.8 cm acrylic soft tissue equivalent attenuator was placed in front of the receptor. Thirty dentists acted independently as observers to differentiate between sound proximal tooth surfaces, natural dental caries, and mechanical defects. Evaluation of intra- and interobserver variability was made with use of the kappa statistic. The Zelen test of odds ratios was used to test for homogeneity, and the Mantel-Haenszel analysis plus stratified logistic regression were used for inference about the common odds ratio. Significance was set at p < 0.05. RESULTS AND CONCLUSIONS: Ignoring stipulation of cavity type, detection was 74% for mechanical defects and 67% for natural caries. The odds of detecting a mechanical defect were 1.40 times the odds of finding natural dental caries cavitation of the same depth. Lesion depth did influence the probability of correctly identifying the presence of a lesion; the odds of identifying cavitation increased 1.41 times with every 0.1 mm increase in lesion depth. Correct designation of lesion type was 1.42 times more likely with mechanical defects than with natural caries (p = 0.003). Intraobserver (kappa = 0.65) and interobserver (kappa = 0.43) agreements were fair to good. Discrimination between natural and artificial lesions was less with the Computed Dental Radiography than that found in our previous study with standard direct emulsion x-ray film.

Bicuspid↗

Diagnosis of frontal sinusitis: one-dimensional ultrasonography versus radiography.

In a series of 407 patients suffering from acute frontal sinusitis, 159 sinuses of 134 patients were trephined. Initial radiography of the operated sinuses pointed out a slight tendency to overdiagnosis; 19 (12 per cent) of the 157 sinuses with positive radiographic signs did not yield secretion. Radiography missed only two true cases of fluid retention. Accuracy of diagnosis by radiography was 87 per cent. Initial ultrasonography gave a sign of retained secretion in 127 cases, of which 122 (96 per cent) were true positive. However, 18 (13 per cent) tracings of the 140 sinuses with secretion gave wrong negative findings. Accuracy of diagnosis by ultrasonography was 86 per cent. It seems evident, that ultrasonography measures better retained secretion (excluding very small amounts) and radiography shows better mucosal swellings.

Adult↗

An evaluation of periapical radiography with a charge-coupled device.

OBJECTIVES: To compare the standards of periapical radiography with a CCD-image receptor with film. METHODS: Three radiography technicians exposed a total of fifty teeth from all areas of the jaws using either size 1 or size 2 film and the Sidexis (Siemens, Bensheim, Germany) direct digital dental radiography system with the appropriate film holders. Image quality was assessed by two dental radiologists for nine individual criteria and overall, on a three-point scale. RESULTS: There was a significant difference between film and sensor exposures (P < 0.014). Six per cent of dental films required retakes compared with 28% with the sensor. CONCLUSION: Periapical radiography with a CCD sensor leads to more errors and thus more retakes than conventional film.

Evaluation Studies as Topic↗

Evaluation of the effectiveness of digital radiography in emergency situations.

The time differences between digital and conventional radiography for emergency patients were investigated, and clinician satisfaction with the two modalities was compared. Time-motion data was collected daily over 5 weeks for a digital group and a conventional X-ray group. For standardization purposes, only emergency patients requiring chest X-rays were selected for the study. Data were collected from 30 patients in each of the two groups in the time-motion study, and 31 out of 50 Emergency and Intensive Care clinicians responded to the questionnaire. Results were analysed by percentage, and chi2 analysis was used where appropriate. The time for availability of images to requesting clinicians was 70% less for digital images compared to conventional radiography. The overall satisfaction between digital and conventional radiography was very similar, but most clinicians expressed an opinion that digital radiography offered significant image modification advantages.

Emergency Medical Services↗

[Orthorad--the online reference database of skeletal plain film radiography].

PURPOSE: It is evident that there is a growing need for Internet-based reference databases for reasons of practicability and due to the increasing use of reporting on digital workstations. The main advantages of online databases are expected with respect to plain film radiography and cross-sectional imaging. A reference database of skeletal plain film radiography was to be created using the Orthorad program. MATERIALS AND METHODS: The most important standard settings and special images of young and healthy adults in plain film radiography were collected over one year. All samples were approved for the Orthorad database by a board qualified radiologist. Based on the workflows of radiographers and radiologists, the records were organized by body part ( http://www.idr.med.uni-erlangen.de/orthorad/orthorad.htm ). This logical data structure will ensure that the tool serves as a source of information in two ways: On the one hand, the radiographer can access information on positioning, tube voltage and cassette format. On the other hand, the radiologist receives important knowledge regarding X-ray anatomy, reference data regarding the human skeleton, and information about the correct reporting for an image. RESULTS AND CONCLUSION: Orthorad is used as an online reference database for traumatologic plain film radiography to support radiographers and radiologists in their daily working routines. To date, user feedback has been positive.

Adult↗

Gastro-oesophageal reflux demonstrated by radiography. A supplement to 24-h pH monitoring.

PURPOSE: Gastro-oesophageal reflux (GOR) is demonstrated by radiography as a supplement to 24-h pH monitoring. MATERIAL AND METHODS: Forty-two patients (mean age 44 years) with suspicion of GOR disease were assessed according to a standard questionnaire. GOR was investigated by 24-h pH-monitoring and by radiography. Oesophageal emptying and the presence of rings or strictures were registered as well. Mucosal biopsies, classified as normal, light oesophagitis, severe oesophagitis, or Barrett's oesophagus, were correlated to age, gender, symptomatology, pH monitoring, and oesophageal emptying. GOR and morphological changes demonstrated by radiography were correlated to pH monitoring and mucosa biopsies. RESULTS: Based on pH monitoring, patients with severe oesophagitis and Barrett's oesophagus had a significantly higher acid exposure compared to patients with normal mucosa and light oesophagitis, with no difference concerning age, gender, and symptoms. Severe oesophagitis, including Barrett's oesophagus, was found only in patients with a positive test for radiologic GOR. Eleven patients had rings or strictures independent of oesophageal mucosal changes. CONCLUSION: GOR demonstrated by radiography identified patients where complications could be expected, which was not possible by pH monitoring alone.

Adolescent↗

A method for evaluating the entrance surface dose from the measurement of exposure and half value layer in intraoral radiography using a radiophotoluminescent dosemeter.

A method for measuring entrance surface dose in intraoral radiography for nationwide survey for the determination of guidance levels was developed using a commercially available radiophotoluminescent dosemeter (RPLD) system. From the ratio of the readings of the RPLD detectors. with and without a 1 mm thick aluminium filter, half value layer (HVL) and the energy dependency correction factor were derived. HVL and exposure for intraoral radiography were obtained with uncertainties of +/- 0.11 mmAl (SD) and +/- 2.1% (CV), respectively. This has been achieved by calibration at various beam qualities used in intraoral radiography. The HVLs and outputs of intraoral radiography units were measured by means of the mailed RPLD holders and also by ionisation chambers in 19 dental schools in Japan. Results obtained from the two methods of measurement agreed well for both HVLs and outputs.

Air↗

Bedside chest radiography as part of a postcardiac surgery critical care pathway: a means of decreasing utilization without adverse clinical impact.

OBJECTIVE: To evaluate the use of bedside chest radiography and patient outcome before and after implementation of a cardiac surgery critical care pathway that included guidelines for bedside radiography. DESIGN: A cohort observational study. SETTING: A university hospital in the midwest. PATIENTS: Three groups, of 100 patients each, undergoing cardiac surgery in 1990, 1991, and 1995. INTERVENTION: Introduction of a critical care pathway. MEASUREMENTS: Medical records were retrospectively reviewed in three groups of 100 patients each: before the introduction of the critical care pathway; 2 months after introduction of the pathway in 1991; and 4 yrs after introduction in 1995. Data were analyzed to determine operative risk for each group. Subsequent analyses determined bedside radiography use, total length of hospital stay, and patient outcome (mortality rate, complications requiring intervention, and reoperation) during hospitalization and at outpatient follow-up 15-30 days postdischarge. RESULTS: Total length of hospital stay was shorter for the 1995 group (7.6+/-6.6 days) compared with other groups (prepathway, 11.1+/-10.3 days; 1991 postpathway, 10.2+/-9.6 days; p<.05). The mean numbers of radiographs per patient were as follows: prepathway, 5.1; 1991 postpathway, 5.2; and 1995 postpathway, 3.3. The mean number of radiographs in the 1995 group was significantly lower (p = .02). More patients had the proposed number of two bedside radiographs described in the pathway in the 1995 group compared with the other groups (prepathway, p<.0001; the two-month postpathway group, p = .01). Twenty-three malpositioned catheters/tubes were found in the prepathway and 1991 groups compared with 11 in the 1995 group (p = .02). No statistically significant difference was found in inpatient complications (mediastinal bleeding, pneumothoraces, and pleural effusions), postdischarge complications, reoperations, or mortality rate. CONCLUSION: Introduction of a critical care pathway can decrease the use of bedside radiography without adversely affecting near-term patient outcomes.

Adult↗

Lung cancer after head and neck cancer: role of chest radiography.

OBJECTIVE: To examine whether screening chest radiographs lead to significantly longer life span in patients found to have pulmonary lesions than in those in whom lung cancer was detected after symptoms developed. STUDY DESIGN: A retrospective study. MATERIAL AND METHODS: Charts of 1,086 patients with squamous cell cancer of the head and neck treated for cure from January 1, 1974, to December 31, 1998, were analyzed. RESULTS: Pulmonary cancer developed in 62 patients. In 41 patients pulmonary malignancy was found because of patient symptoms. In 21 patients lung cancer was detected by routine annual chest radiography. Seventy-five percent of lung cancers were detected within 3 years of initial treatment of the head and neck cancer. CONCLUSION: Chest radiography is a poor screening tool, because it failed to find pulmonary lesions in more than 65% (41/62) of patients who were later found to have pulmonary cancer. Survival rate did not differ between patients in whom pulmonary cancer was found by screening chest radiography and those in whom symptoms prompted evaluation (P = .48). Using current treatment protocols, routine yearly chest radiography did not improve survival in patients with head and neck cancer. However, there maybe new therapeutic regimens under investigation that would benefit these patients if their lung cancers were found in early stages of disease. Future directives must include the establishment of an effective follow-up protocol for the early detection of lung malignancies in these patients.

Adult↗

Computed and conventional chest radiography: a comparison of image quality and radiation dose.

The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P > 0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (chi(2) tests).

Humans↗

Common errors in panoramic radiography of edentulous patients.

PURPOSE: Instructions for patient positioning during panoramic radiography usually describe positioning dentate patients, and errors in patient positioning are commonly identified by distortion of the dentition. The purposes of this study were to identify common errors in panoramic radiography of edentulous patients, describe the image distortions that can be expected with positioning errors in edentulous patients, and review quality assurance methods that improve the diagnostic value of panoramic films. MATERIALS AND METHODS: Panoramic films were randomly selected from the inactive files of 75 edentulous patients seen at the dental school for complete denture construction. The radiographs were numbered and reviewed by a board-certified oral and maxillofacial radiologist trained to identify errors in panoramic radiography. RESULTS: Of the 75 panoramic radiographs examined, only 6 films (8.0%) were free of errors, and 67 films (89.3%) had one or more errors in patient positioning and 33 films (44.0%) had one or more technical errors. The most common positioning errors were positioning the chin too high (32 films, 41.3%) and positioning the patient too far forward (26 films, 34.7%). CONCLUSIONS: Without modification, manufacturer's instructions for positioning dentate patients during panoramic radiography may result in positioning errors on the panoramic radiographs of edentulous patients. Proper training and appropriate attention to detail while exposing and developing panoramic films are required to ensure maximum diagnostic benefits for edentulous patients.

Chin↗

Evaluation of a quality control phantom for digital chest radiography.

RATIONALE AND OBJECTIVES: To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS: The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects placed in the "heart," "lung," and "subdiaphragm" areas of the phantom. In addition, the signal levels from these areas were compared to similar areas from clinical chest radiographs. RESULTS: The test objects included within the phantom were effective in assessing image quality except within the subdiaphragm area, where most of the low contrast disks were visible. Spatial resolution for the DR systems evaluated with the phantom ranged from 2.6 lp/mm to 4 lp/mm, falling within the middle of the line pair range provided. The signal levels of the heart and diaphragm regions relative to the lung region of the phantom were significantly higher than in clinical chest radiographs (0.67 versus 0.21 and 0.28 versus 0.10 for the heart and diaphragm regions, respectively). The heart-to-diaphragm signal level ratio, however, was comparable to those in clinical radiographs. CONCLUSION: The findings suggest that the attenuation characteristics of the phantom are somewhat different from actual chests, but this did not appear to affect the post-processing used by the imaging systems and usefulness for QC of these systems. The qualitative and quantitative measurements on the phantom for different systems were similar, suggesting that a single phantom can be used to evaluate system performance in a routine QC program for a wide range of digital radiography systems. This makes the implementation of a uniform QC program easier for institutions with a mixture of different digital radiography systems.

Humans↗

Magnetic resonance imaging, radiography, and scintigraphy of the finger joints: one year follow up of patients with early arthritis. The TIRA Group.

OBJECTIVES: To evaluate synovial membrane hypertrophy, tenosynovitis, and erosion development of the 2nd to 5th metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints by magnetic resonance imaging in a group of patients with rheumatoid arthritis (RA) or suspected RA followed up for one year. Additionally, to compare the results with radiography, bone scintigraphy, and clinical findings. PATIENTS AND METHODS: Fifty five patients were examined at baseline, of whom 34 were followed up for one year. Twenty one patients already fulfilled the American College of Rheumatology (ACR) criteria for RA at baseline, five fulfilled the criteria only after one year's follow up, whereas eight maintained the original diagnosis of early unclassified polyarthritis. The following MRI variables were assessed at baseline and one year: synovial membrane hypertrophy score, number of erosions, and tenosynovitis score. RESULTS: MRI detected progression of erosions earlier and more often than did radiography of the same joints; at baseline the MRI to radiography ratio was 28:4. Erosions were exclusively found in patients with RA at baseline or fulfilling the ACR criteria at one year. At one year follow up, scores of MR synovial membrane hypertrophy, tenosynovitis, and scintigraphic tracer accumulation had not changed significantly from baseline; in contrast, swollen and tender joint counts had declined significantly (p<0.05). CONCLUSIONS: MRI detected more erosions than radiography. MR synovial membrane hypertrophy and scintigraphy scores did not parallel the changes seen over time in clinically assessed swollen and tender joint counts. Although joint disease activity may be assessed as quiescent by conventional clinical methods, a more detailed evaluation by MRI may show that a pathological condition is still present within the synovium.

Adult↗

Place of ultrasound and radiography in obstetrics.

In the two years after an ultrasound service was introduced at this hospital obstetric referrals for abdominal radiography decreased by over 55%. Most of these were for estimation of fetal maturity. Out of 349 such patients subjected to radiography in 1976, 176 had already been examined by ultrasound; in only four did radiography appear to influence management. We believe that if a satisfactory ultrasound scan is obtained before 30 weeks of gestation subsequent radiological estimation of fetal maturity is unjustified. Radiography may still be necessary, however, for diagnosing fetal abnormalities.

Congenital Abnormalities↗

Radiography of injured arms and legs in eight accident and emergency units in England and Wales. Royal College of Radiologists Working Party.

The use of radiography of the arms and legs (extremity radiography) in 32936 patients attending eight accident and emergency units was studied. Although extremity radiography was satisfactory in terms of cost per bony injury detected (40 pounds), considerable differences between centres in the predicted and actual yields of bony injury were observed. Guidelines for selection of patients for extremity radiography would reduce variability in its use and improve the quality of present practice.

Arm Injuries↗