Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy, Scanning Probe”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Vortex configurations, matching, and domain structure in large arrays of artificial pinning centers.

High-resolution scanning Hall probe microscopy has been used to image vortex configurations in very large periodic arrays of artificial pinning sites. Strong matching effects are seen at fields where either one or two vortices can sit at a site; with three vortices per site, however, no clear matching is observed. Matching effects have also been observed at several fractional multiples of the matching field, including 1/5, 1/4, 1/3, 1/2, and 3/4. These fractional values are characterized by striking domain structure and grain boundaries.

Journal Article↗

Symmetry locking and commensurate vortex domain formation in periodic pinning arrays.

The spontaneous formation of domains of commensurate vortex patterns near rational fractional matching fields of a periodic pinning array has been investigated with high resolution scanning Hall probe microscopy. We show that domain formation is promoted due to the efficient incorporation of mismatched excess vortices and vacancies at the corners of domain walls, which outweighs the energetic cost of creating them. Molecular dynamics simulations with a generic pinning potential reveal that domains are formed only when vortex-vortex interactions are long range.

Journal Article↗

Tilt of pancake vortex stacks in layered superconductors in the crossing lattice regime.

We study crossing vortices in strongly anisotropic Bi2Sr2CaCu2O8+delta single crystals. Using scanning Hall probe microscopy and Bitter decoration techniques, we find an asymmetry of magnetic field profiles produced by pancake vortices (PVs), which are interacting with Josephson vortices (JVs), near the surface of the crystal. We attribute the observed asymmetry to a substantial tilt (14-18 degrees) of PV stacks, which is produced by the torque due to the surface currents and JVs. We calculate the tilt angle and obtain agreement with experimental data when the irreversible in-plane magnetization is included. A further refinement to the model is considered which accounts for a reduction in the PV stack line tension near the sample surface.

Journal Article↗

Comparative imaging of a bacterial surface-located GFP fusion protein by epifluorescence and scanning near-field optical microscopy.

IcsA is an autotransporter protein that plays a role in the virulence of Shigella bacteria. We have examined the cellular localization of a fusion of an IcsA fragment to the green fluorescent protein (GFP) expressed in Escherichia coli using a dual epifluorescence and scanning near-field optical microscope. By combining the data obtained from far-field with near-field microscopy of the same sample, discrimination between surface-bound fusion proteins and fusion proteins located in the cellular cytoplasm becomes possible. Furthermore, and for the first time, the inherent advantages in resolution of the near-field images provides highly specific details of the location of a GFP fusion protein on a bacterial cell surface.

Bacterial Proteins↗

Integration of a scanning ion conductance microscope into phase contrast optics and its application to the quantification of morphological parameters of selected cells.

We have previously described a pulse-mode scanning ion conductance microscope to investigate membrane surfaces and volume changes of individual cells in culture. We have now developed a miniaturized scanning headstage that enables us to select individual cells for recording under phase contrast optics, considerably improving the selection of individual cells for scanning as well as the positioning of the scanning frames with respect to the position of the cell somata. We show an application in which surfaces and volumes of somata and processes of cultured cells from the central nervous system were quantified separately.

Animals↗

Scanning ion conductance microscopy reveals how a functional renal epithelial monolayer maintains its integrity.

BACKGROUND: To function as a transport barrier a renal tubule epithelial monolayer needs to maintain its integrity when, sudden hypertonic stress causes cell shrinkage, new cells are added, or cells in the monolayer die. However, the mechanism used to achieve this is largely unknown. Scanning ion conductance microscopy (SICM) has been shown to be suitable for imaging the surface of live renal cells with high topographic resolution, and can be used to elucidate how a functional renal epithelial monolayer maintains its integrity. METHODS: SICM was used for high spatial resolution topographic imaging of Xenopuslaevis renal epithelial A6 cells cultured on membrane filter inserts. RESULTS: The SICM images of A6 cells showed that the epithelial monolayer maintains its integrity under hypertonic stress, and during cell division and death. Sequential SICM topographic images revealed detailed structural changes and their time course for these protective processes, which involve highly cooperative cell movement. Some "balloon-like" structures were observed at susceptible tight junction regions, which were proposed to help cell maintaining the monolayer permeability integrity. CONCLUSION: SICM is a powerful tool for research on living renal epithelial cells, and has been used to elucidate how a functional epithelial monolayer maintains its integrity. Using this technique we have observed that during hypertonic stress and regeneration, an organized sequence of events protect the loss of integrity of monolayer so that tight junctions and cell-cell contact are maintained and disruption to the function of whole monolayer is prevented.

Animals↗

Blood cell adhesion on sensor materials studied by light, scanning electron, and atomic-force microscopy.

Unwanted interactions of biomedical sensors with surrounding tissues, body fluids, and cells are one of the most crucial problems affecting their long-term stability. In vivo processes were simulated in a computer-controlled bioreactor connected to a flow chamber system. Optical sensor materials were inserted into a parallel-plate chamber and monitored by light microscopy in order to get information about the number of adhered cells. Tests with thrombocyte-enriched plasma show that novel phosphorylcholine (PC)-polymer-coated sensors appear to be more bioinert, and thus demonstrate better haemocopatibility in comparison with untreated glass sensors. The influence of different materials on the morphology of adhered cells was investigated by off-line methods such as scanning electron microscopy (SEM) and atomic-force microscopy (AFM). SEM showed a reduction in the number of adhered thrombocytes and the lack of any fibrin network on the PC-polymer-modified glass surface, in contrast to the pure glass surface. AFM gives topographical information, and the calculated contact areas and cell volumes indicate smaller interactions between cells and sensor material in the case of PC-polymer-coated sensors.

Bioreactors↗

Replication molds having nanometer-scale shape control fabricated by means of oxidation and etching.

A means of accurate control of the curvature radius of molds that are used in nanostructure replication techniques is presented. The local non-uniform growth of SiO2 at regions with high curvature is used to fabricate molds with a curvature radius ranging anywhere between 10 and 250 nm. The mold radius is predicted by numerical simulation as a function of oxidation temperature and time and confirmed by a series of oxidation and etching experiments. The silicon, silicon dioxide, and polymer nanostructures are analyzed by scanning electron microscopy and compared with the theory. Replication into photo-plastic polymer from various sharp and round molds is performed, and their properties are discussed. Our results are useful for designing nanostructures in the area of soft lithography and nanoprobe engineering.

Crystallization↗

Analysing one isolated single walled carbon nanotube in the near-field domain with selective nanovolume Raman spectroscopy.

In this paper, we describe a new method to the selective nanovolume analysing of one isolated single walled carbon nanotube (SWNT). This concept is based on actually available imaging micro-spectrometry systems for working in near-field domain combined with a stigmatic solid immersion lens. This combination of different analytical methods, and modified and configured equipment entitles us to expand the functionality toward a three-dimensional (3D) nanovolume Raman mapping and photoluminescence intensity with a possible discrimination in polarization, as well as photoluminescence decaytime constant mapping with their unique combination. Subsequently, selective spectra can be acquired from the same location on the samples. By spectrally selecting a SWNT, we registered the spatial distribution of the emitted photons in x, y, z vectors to determine the position of a SWNT in the near-field domain. For the SWNTs that are localized with an accuracy better than 18 nm in the x, y and <1 nm in the z directions, we demonstrate an analytical sensitivity close to a single nanotube with unity throughput. This near-field capability is applied to resolve local variations unambiguously in the Raman spectrum along one single SWNT. Finally, in this paper, we report what we believe to be the first evidence of Raman mapping and 3D real optical imaging of carbon nanotubes with near-field resolution.

Image Processing, Computer-Assisted↗

Characterization of a novel 1,3-bis(p-iminobenzoic acid)indane Langmuir-Blodgett film for organic vapor sensing.

In the present paper we report about the Langmuir-Blodgett thin film characterization and organic vapor sensing properties of a novel 1,3-bis(p-iminobenzoic acid)indane (IBI) containing polar carboxylic acid groups. LB film properties of IBI material is characterized by UV-visible spectroscopy, atomic force microscopy, and quartz crystal microbalance. Our results show that high-quality and uniform LB films can be prepared with the transfer ratio of over 0.95. Organic vapor sensing properties are studied using quartz crystal microbalance measurement system. IBI film is found to be significantly more sensitive to benzene and the response of LB sample is fast, large, and reversible. The sensitivity of detection of toluene, ethyl alcohol, and isopropyl alcohol is much smaller than that of benzene. This newly synthesized IBI is a suitable molecule for the fabrication of an LB film and can be regarded as a promising sensing material in the development of a room temperature gas sensor for benzene vapor applications.

2-Propanol↗

AMY plaques in familial AD: comparison with sporadic Alzheimer's disease.

OBJECTIVE: To assess AMY expression in familial AD (FAD). BACKGROUND: The discovery of nonbeta-amyloid (Abeta), plaque-like deposits composed of a 100-kd protein (AMY) in sporadic AD (SAD) brains prompted us to determine whether these plaques (AMY plaques) also occur in AD due to mutations of the presenilin-1 (PS-1), presenilin-2 (PS-2), or the amyloid precursor protein (APP) genes. METHODS: We used immunohistochemistry and confocal laser scanning microscopy to probe the brains of 22 patients with FAD (13 with PS-1, 5 with PS-2, and 4 with APP mutations) and 14 patients with SAD. RESULTS: AMY plaques were present in all SAD and FAD brains, including an FAD/PS-1 brain from an individual with preclinical disease. The morphology of AMY plaques in SAD and FAD brains was indistinguishable, but they differed from Abeta deposits because AMY plaques lacked an immunoreactive core. AMY plaques sometimes colocalized with Abeta(x-42) deposits, but they did not colocalize with Abeta(x-40) plaque cores in either SAD or FAD brains. The percent of cortical area occupied by AMY was greater in FAD than in SAD brains (mean percent area = 9.8% and 5.9%, t = 2.487, p = 0.018). In particular, APP and PS-1 cases had more AMY deposition than PS-2 or SAD cases (12.9%, 10.5%, 6.2% in APP, PS-1, and PS-2 AD). CONCLUSIONS: AMY plaques are consistently present in familial AD due to presenilin-1 (PS-1), PS-2, and amyloid precursor protein mutations, and they can begin to accumulate before the emergence of dementia.

Aged↗

Field enhancement in apertureless near-field scanning optical microscopy.

The near field of an apertureless near-field scanning optical microscopy probe is investigated with a multiple-multipole technique to obtain optical fields in the vicinity of a silicon probe tip and a glass substrate. The results demonstrate that electric field enhancements of >15 relative to the incident fields can be achieved near a silicon tip, implying intensity enhancements of several orders of magnitude. This enhancement arises both from the antenna effect of the elongated probe and from a proximity effect when the probe is near the substrate surface and its image dipoles play a role.

Journal Article↗

Enhancement of Raman signals with silver-coated tips.

Silver coated SiN and SiO(2) tips have been fabricated for use with a bottom-illumination tip-enhanced Raman spectroscopy (TERS) setup with a 488 nm laser excitation. SiN tips with 50-60 nm of deposited Ag give the best TERS enhancements for brilliant cresyl blue test analyte spin-coated on a glass slide. Ag nanoparticles on SiN or SiO(2) rather than Si tips are better for TERS because of the proximity of the wavelengths of their surface plasmon resonance to 488 nm. Adjustments of tilt angle of the metallized tip with respect to the surface plane is shown to considerably raise the intensities of the TERS signals, even from tips that initially appear to be rather non-enhancing. This work helps to enable the more frequent use of the 488 nm laser for nanoscale chemical analysis with both TERS and fluorescence imaging in the same setup.

Microscopy, Scanning Probe↗

Carbon nanotubes and nanowires for biological sensing.

This chapter reviews the recent development in biological sensing using nanotechnologies based on carbon nanotubes and various nanowires. These 1D materials have shown unique properties that are efficient in interacting with biomolecules of similar dimensions, i.e., on a nanometer scale. Various aspects including synthesis, materials properties, device fabrication, biofunctionalization, and biological sensing applications of such materials are reviewed. The potential of such integrated nanobiosensors in providing ultrahigh sensitivity, fast response, and high-degree multiplex detection, yet with minimum sample requirements is demonstrated. This chapter is intended to provide comprehensive updated information for people from a variety of backgrounds but with common interests in the fast-moving interdisciplinary field of nanobiotechnology.

Biosensing Techniques↗

Extended, relaxed, and condensed conformations of hyaluronan observed by atomic force microscopy.

The conformation of the polysaccharide hyaluronan (HA) has been investigated by tapping mode atomic force microscopy in air. HA deposited on a prehydrated mica surface favored an extended conformation, attributed to molecular combing and inhibition of subsequent chain recoil by adhesion to the structured water layer covering the surface. HA deposited on freshly cleaved mica served as a defect in a partially structured water layer, and favored relaxed, weakly helical, coiled conformations. Intramolecularly condensed forms of HA were also observed, ranging from pearl necklace forms to thick rods. The condensation is attributed to weak adhesion to the mica surface, counterion-mediated attractive electrostatic interactions between polyelectrolytes, and hydration effects. Intermolecular association of both extended and condensed forms of HA was observed to result in the formation of networks and twisted fibers, in which the chain direction is not necessarily parallel to the fiber direction. Whereas the relaxed coil and partially condensed conformations of HA are relevant to the native structure of liquid connective tissues, fully condensed rods may be more relevant for HA tethered to a cell surface or intracellular HA, and fibrous forms may be relevant for HA subjected to shear flow in tight intercellular spaces or in protein-HA complexes.

Aluminum Silicates↗

Suggested guidelines for the topographic evaluation of implant surfaces.

The bone anchorage components of commercially available oral implant systems differ in surface roughness by at least sixfold. Correct reporting of the surface roughness of implant systems is important, since one cannot exclude the possibility that surface roughness will influence clinical results. However, many confusing statements are found in the literature when the surface topography of implants is described. Different measuring instruments and techniques strongly influence the outcome of a topographic characterization. Furthermore, a screw-type design introduces problems for most measuring instruments. Without a standard procedure, it is generally impossible to compare values from one study with another. The aim of the present study was to suggest standards for topographic evaluation of oral implants in terms of measuring equipment, filtering process, and selection of parameters. It is suggested that the measuring instrument be able to measure all parts of a threaded implant if the investigation relates to such a design. Preferably, 3-dimensional measurements should be performed. On screw-type implants, tops, valleys, and flanks should be evaluated. At least 3 samples in a batch should be evaluated, filter size must be specified, and at least one of each height, spatial, and hybrid parameter should be presented.

Biocompatible Materials↗

Spatial distribution of the beta2 integrin (CD11b/CD18) and L-selectin (CD62L) adherence receptors on human neutrophils by Conventional Optical Scanning Microscopy (COSM).

Receptors such as CD62L and CD11b/CD18, are transmembrane glycoproteins which regulate leukocyte adhesive phenotype. Flow cytometry (FCM) makes it possible to assess a characterization of the cell activation level by receptor quantifying, but that technique does not integrate other factors of adherence regulation, such as spatial distribution and molecular conformation. Our study consisted in exploring the main adherence receptors on Polymorphonuclear Neutrophils (PMN) that were simultaneously analyzed by FCM and Conventional Optical Scanning Microscopy (COSM). FCM analysis showed that TNFalpha induce a decrease in CD62L expression and an increase in beta2 integrins. COSM analysis distinguished three stages of cellular distribution of CD11b/CD18 within resting PMN: most of them (about 80%) had homogeneous distribution (heterogeneous spots distributed over the entire cell surface), for 10-15% of the cells, there was a crown distribution around the widest cell diameter and in less that 10% of them receptor distribution was polarized. CD62L was in the form of heterogeneous spots distributed in a circle on the surface on non-stimulated PMN. PMN stimulation by TNFalpha was associated to a randomized clustering involving both selectin and beta2 integrin. Three-dimensional analysis elicited data not shown by quantitative cytometry. For a single averaged value of the density determined by FMC, various spatial distributions of adherence receptors are found on the surface of non-stimulated PMN. The characterization of the leukocyte adhesive phenotype has to integrate adherence receptors density as well as their spatial distribution.

CD18 Antigens↗