Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Meridians”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Colorimetric and spectroradiometric characteristics of narrow-field-of-view clear skylight in Granada, Spain.

As part of our ongoing research into the clear daytime sky's visible structure, we analyze over 1,500 skylight spectra measured during a seven-month period in Granada, Spain. We use spectral radiances measured within 3 degrees fields of view (FOV's) to define colorimetric characteristics along four sky meridians: the solar meridian and three meridians at azimuths of 45 degrees, 90 degrees, and 315 degrees relative to it. The resulting clear-sky chromaticities in 44 different view directions (1) are close to but do not coincide with the CIE daylight locus, (2) form V-shaped meridional chromaticity curves along it (as expected from theory), and (3) have correlated color temperatures (CCT's) ranging from 3,800 K to infinity K. We also routinely observe that sky color and luminance are asymmetric about the solar meridian, usually perceptibly so. A principal-components analysis shows that three vectors are required for accurate clear-sky colorimetry, whereas six are needed for spectral analyses.

Journal Article↗

Analysis of visual modulation sensitivity. III. Meridional variations in peripheral flicker sensitivity.

Critical flicker frequency (CFF) and modulation sensitivity were measured throughout the visual field as a function of meridian, eccentricity, and luminance. The stimulus conditions were designed to excite preferentially the long-wavelength-sensitive (R) cones in equal numbers at each retinal location. Temporal-frequency responses under these conditions can be partitioned into two components by following the analysis of Kelly [J. Opt. Soc. Am. 51, 422 (1961)]: a high-frequency linear component unaffected by the mean luminance level and a nonlinear adaptive component that conforms to Weber's law of proportionality to luminance. The results suggest that the time constant of the linear component varies to some extent with meridian at a constant eccentricity, in addition to the substantial increase with eccentricity along all meridians. Retinal variations in sensitivity of the nonlinear, adaptive aspect of the visual response were small when equal numbers of cones were stimulated, and the variations did not account for the changes in CFF with either eccentricity or meridian.

Humans↗

Image invariance with changes in size: the role of peripheral contrast thresholds.

The appearance of objects generally does not change with changes in the size of their retinal image that occur as the distance from the observer increases or decreases. Contrast constancy ensures this invariance for suprathreshold image features, but fully robust size invariance also requires invariance at threshold, so that near-threshold image features do not appear or disappear with distance changes. Since the angular size and the eccentricity of image features covary with distance changes, the threshold requirement for invariance could be satisfied approximately if contrast thresholds were to vary as the product of the spatial frequency and the eccentricity from the fovea. This model fits contrast thresholds for orientation identification over spatial frequencies of 1-16 cycles/deg and for retinal eccentricities of as much as 23 deg. Contrast detection thresholds from six different studies conform to this model over an even wider range of spatial frequencies and retinal eccentricities. The fitting variable, the fundamental eccentricity constant, was similar for all three studies that measured detection along the horizontal meridian and was higher for the orientation identification contrast thresholds along the same meridian. The eccentricity constant from studies that measured detection along the vertical meridian was higher than the constant calculated for the horizontal meridian and lower than the eccentricity constant for chromatic isoluminance gratings. Our model and these results provide new tools for analyzing the visibility of displays and for designing equal-visibility or variable-visibility displays.

Contrast Sensitivity↗

An exploratory study of the relationship between the midday-midnight law and electrical conduction properties of corresponding acupuncture points.

The midday-midnight law is a well-known empirical law in Oriental medicine stating that the circadian rhythm of internal organs influences their paired organs according to the time of day. However, there has been little research to test the purported relationship between the time of day and organ function. The purpose of this preliminary study was to investigate whether the midday-midnight law applies to the meridian activity and the electrical conduction properties of the acupuncture points. We used the digital readout instrument (MERIDIAN) to measure electrical conduction properties at 12 acupuncture points corresponding to the 12 meridians at four times: 12:00, 14:00, 22:00, and 24:00 hours. There were no significant differences in the electrical current values measured at the four times in any meridian. However, the mean current values of 12 acupuncture points changed significantly over time (P < 0.0001). The mean current values were significantly higher at 14:00 (P < 0.001), 22:00, and 24:00 hours (P < 0.001) than at 12:00 hours. The highest current value occurred at 22:00 hours and was significantly higher than 24:00 hours (P < 0.05). Although these do not conclusively support the traditional midday-midnight theory, our data suggest the existence of some type of daily variability in electrical current.

Acupuncture Points↗

Microwave propagation on acupuncture channels.

Quantitative studies on functional state of acupuncture points and meridians have been done mostly by electrical measurement that requires the contact of the electrode on skin and is subject to pressure, humidity, etc. In this study, a new modality of using microwave was investigated. Microwave energy in the frequency range of 250 approximately 550MHz was irradiated on an acupuncture point. Transmitted microwave energy along the meridian was measured at the next acupuncture point of the same meridian. Diabetic and cancer patients were compared with healthy persons. Normal group consisted of 50 healthy persons. Diabetic group included 50 diabetic patients. Breast cancer group had also 50 patients. All 12 meridians on both right and left hands and feet were measured. For the diabetic group, the microwave energy propagation in this frequency range was 1.417 dB lower along Lung channel and 1.601 dB higher along Spleen channel compared with the normal group regardless of sex and diabetic types. For cancer patients, the propagation was 1.620 dB lower along Liver channel and 1.245 dB higher along Kidney channel compared with the normal group. Microwave energy proved to be a potential diagnostic method.

Acupuncture Points↗

Normative values for visual fields in 4- to 12-year-old children using kinetic perimetry.

We report normative data for 4- to 12-year-old children using a kinetic perimetry technique that employs a double arc perimeter with a 6-degree target designed for use with infants and children. The subject population consisted of 84 children in four age groups (4, 5, 7, and 10 yrs) and 21 adults as comparison subjects. Individuals had eye examinations to rule out causes of abnormal visual fields. Mean visual field size was determined separately for the right and left eyes in each age group. In the 4-year-old group, the mean extent of visual field along each of the four meridians for the right eye was 59, 48, 52, and 85 degrees of arc for radial meridians orientation set at 45, 135, 225, and 315 meridians, respectively. The visual field extent in each quadrant generally increased with age. The overall extent of field as measured along the four meridians for all subject groups increased significantly with the age, indicating a continued growth of visual field size in older children. These data suggest that adult visual field size is achieved at about 11.6 years of age.

Adult↗

Laser in situ keratomileusis for simple myopic, mixed, and simple hyperopic astigmatism.

PURPOSE: To summarize initial results of astigmatic laser in situ keratomileusis (LASIK) for 41 eyes of 26 patients using the EC-5000 Nidek system and assess its safety, efficacy and predictability. METHODS: The EC-5000 Nidek excimer laser was used to correct simple myopic, mixed, and simple hyperopic astigmatism with manifest cylinder from 2.00 to 6.50 D. Ablation zone diameters were 6.5 mm (steep meridian ablation) to 7.5 mm (flat meridian ablation) with a repetition rate of 40-41 Hz. In eyes with simple myopic and mixed astigmatism, ablation was performed in both meridians; in eyes with simple hyperopic astigmatism, ablation was performed in the flat meridian alone. Follow-up was 3 months in all eyes. RESULTS: Uncorrected visual acuity was 20/40 or better in 85% of the eyes. Uncorrected visual acuity was equal to the preoperative spectacle-corrected visual acuity in 63% of the eyes. Intended cylinder correction was within 1.00 D in 95% of eyes. No eyes lost lines of spectacle-corrected visual acuity. CONCLUSION: LASIK using the EC-5000 excimer laser appears to effective in the treatment of simple myopic, mixed, and simple hyperopic astigmatism, with favorable results as compared to those previously described for astigmatic keratotomy.

Astigmatism↗

Laser in situ keratomileusis with the Nidek EC-5000 excimer laser for astigmatism greater than 4.00 D.

PURPOSE: To evaluate laser in situ keratomileusis (LASIK) performed with the Nidek EC-5000 excimer laser in 66 astigmatic eyes with cylinder from 4.00 to 8.00 D. METHODS: LASIK was performed with the Nidek EC-5000 excimer laser in 66 astigmatic eyes with cylinder from 4.00 to 8.00 D. Based on Chayet's nomogram, ablation zone diameters were 5.5 mm (steep meridian ablation) to 7.5 mm (flat meridian ablation). In eyes with simple myopic astigmatism, mixed astigmatism, and compound myopic astigmatism (low sphere), ablation was performed in both meridians. In eyes with simple hyperopic astigmatism, ablation was performed in the flat meridian alone. In eyes with compound hyperopic astigmatism, ablation zone diameter was 5.5 mm and the transition zone was 7.5 mm. RESULTS: Uncorrected visual acuity was 20/40 or better in 89% of eyes and was equal to preoperative best spectacle-corrected visual acuity in 62% of eyes. No eyes lost lines of best spectacle-corrected visual acuity. CONCLUSIONS: Using the Nidek EC-5000 excimer laser, we had satisfactory results in the treatment of astigmatic eyes with cylinder from 4.00 to 8.00 D, based on Chayet's nomogram.

Astigmatism↗

Very high frequency ultrasound biometry of the anterior and posterior chamber diameter.

PURPOSE: To measure the largest diameter of the anterior chamber (AC) and posterior chamber (PC) dimension and its orientation and determine the relationship with the principal keratometric meridians. METHODS: Twenty-eight eyes of 14 subjects were scanned with high frequency (50 MHz) ultrasound in sequential meridional scan planes at 30 degrees increments. Observer identified angle and ciliary sulcus recess boundaries in each patient scan set were fit with an elliptical model to obtain the ellipse semi-major axis corresponding to the largest diameter and its meridional orientation. Anterior and posterior chamber diameters from raw data and model fit were compared using linear statistics. Circular statistics were used to compare the orientation of the largest diameter for raw ultrasound measurements, model estimations of largest diameter, and autorefractor determined keratometric axes. RESULTS: The mean model diameters were anterior chamber OD 12.07 mm (0.32 SD); anterior chamber OS 12.06 mm (0.36 SD); posterior chamber OD 12.35 mm (0.42 SD); posterior chamber OS 12.33 mm (0.43 SD). The general trend for orientation of the meridian of largest diameter was in the horizontal meridian. In over 35% of eyes the difference between AC or PC meridian and the flat keratometric axis was greater than 20 degrees. CONCLUSIONS: Accurate and reproducible anterior segment biometry depends on visualization of structures and minimization of eye and head movement error. The range and standard deviation of the diameter and orientation measures suggests anatomic variation is sufficient to require biometry for proper sizing and placement of intraocular devices that use angle or sulcus fixation.

Adult↗

Corneal shape of Hong Kong-Chinese.

Corneal asphericity (the p-value, p) and apical corneal radius (r0) were calculated for 63 Hong Kong-Chinese (39 male and 24 female), using the Topographic Modeling System (TMS-1). The values of p and r0 in, and between, the two principal meridians were compared, and the effects of refractive error and gender were also investigated. The mean +/- SD r0 and p along the flattest meridian of the right eye were 7.82 +/- 0.26 mm and 0.78 +/- 0.12 respectively. The mean +/- SD r0 and p along the steepest meridian of the right eye were 7.64 +/- 0.26 mm and 0.83 +/- 0.15 respectively. Meridional variations were found in r0 and in p. There was no correlation between p and r0 along the two principal meridians. p was not significantly correlated to the refractive error but r0 was. Our results agree with previous findings that while males have longer r0 than females, their p are not significantly different.

China↗

Syndroma: glaucoma pigmentatum primarium--pigmented glaucoma.

In this study pigmented glaucoma was diagnosed in 29 out of 4350 patients suffering from glaucoma. In clinical analysis of those cases main attention was put on Krukenberg spindle with emphasis on the process and reason of its development. In all cases of Krukenberg spindle moderate myopia and myopic astigmatism were present. The main axis of the spindle lies in the principal meridian of corneal astigmatism. The principal meridian of the anterior cornea surface corresponds with the axis of the principal meridian of the posterior corneal surface. The higher degree of astigmatism more pronounced Krukenberg spindle. This corresponds to a number of cases in which the spindle is hardly recognisable in the astigmatism, of only +/- 0.25 to +/- 0.50 Dcyl. The axis of meridian corresponds to direct astigmatism (from 110 degrees to 70 degrees). The authors conclude that there is no pigmented Krukenberg spindle without myopic astigmatism. It is for this reason and because of the inheritance factor that this type of glaucoma should be considered primary glaucoma and a separate clinical entity.

Adult↗

[A review of mathematical descriptors of corneal asphericity].

PURPOSE: Corneal asphericity may be modeled on a conic section which can be described by the apical radius of curvature in the meridian studied and by a measure of the degree of asphericity. MATERIAL AND METHODS: Through an extensive review of the literature, we expose the principles, the population variations and report the application of such corneal modeling. RESULTS: The aspheric anterior corneal surface can be described by a conic section, defined by its radius of curvature and by a parameter measuring asphericity. We analyse the various parameters used in the literature to determine their usefulness. Conic sections, obtained by cutting a cone by a plane, include ellipses, hyperbolas and parabolas. Two useful parameters are the apical radius of the ellipse and its eccentricity defined in Cartesian terms by a second order equation where the apical radius is R and the eccentricity is e: The apical radius is that of the circle tangent to the apex of the conic section and e describes the variation of this curve with distance from the corneal apex. Baker introduced the form factor p making the equation: with It is easier to understand the effect of alteration of p than of e on corneal curvature: There is a relation between the horizontal, a, and the vertical, b, hemi-axes and R The advantage of this notation is that e(2) can be greater than 1 When p=0 the conic section is a parabola, when p<0 it is a hyperbola. Kiely et al. studied corneal asphericity by photokeratoscopy and introduced the parameter Q, where Q=p-1. Q, the asphericity factor, is used by the Eyesis and Orbscan systems; when Q=0 the cornea is spherical. Thus different parameters describe variations in corneal curvature along any meridian. Average anterior corneal asphericity using various keratometric systems is p=0.8, making the corneal section a prolate ellipse. However there is great individual variation, 20% of normals exhibiting oblate (p>1), paraboloid (p=0) or hyperbolic (p<0) corneas. all becoming more spherical with age. Little connection between asphericity and ametropia is reported, except for a tendency to flattening in myopia and towards oblateness in progressive myopia. Direct measurement of denuded cadaver corneas gave a prolate elliptical profile although calculation after deduction of epithelial thickness measured by ultrasonic biomicroscopy suggested p=-0.22, a hyperbolic profile. The few reports on the posterior surface suggest it to be hyperbolic or prolate. Increasing distance from the corneal apex worsens the comparison to a conic section as flattening increases. Precision can be improved by adding polynomial coefficients above the second degree to the equation of the section: The non-toric 3D corneal surface can be described by the following equation for the revolution of a conic section about the optic axis: x(2)+y(2)+pz(2)-2rz=0 where z is the axis of revolution. Since the mean value of p is 0.8 this corresponds to a sphere stretched along one axis, as is a rugby ball. Each meridian has the same radius of curvature and the value of p is constant. For a toric cornea the radius and value of p must be defined for two meridia at right angles. This corresponds to an elongation on an axis different from that of revolution. Similarly a toric ellipsoid is generated by rotation of an arc around an axis at right angles to its elongation. Because of its asphericity, representation of the corneal surface depends on the direction in which its curvature is measured: In the ellipsoidal model this depends on the principal meridians, the tangential, in the plane of the axis of symmetry and the saggittal, perpendicular to this. These may define two radii of curvature, the saggital (axial) and the tangential. Most algorithms assume these properties of ellipsoids. Asphericity is translated into variations in radius of curvature from apex to periphery, increasing for a flat periphery, decreasing for a steep one. Associated to toricity, it gives rise to the common butterfly pattern. Spherical aberration is minimal through a small pupil but becomes significant the larger the aperture, with deterioration of image quality. Raytracing allows analysis of the effects of non-axial rays. The mean value of Q, at -0.26 thanks to the naturally prolate asphericity of the cornea reduces spherical aberration by half. The relaxed form of the crystalline lens further reduces it by inducing the opposite spherical aberation to that of the cornea. This is important in accommodation and presbyopia. The use of an aspheric corneal surface in the schematic eye allows calculation of the ideal asphericity, which corresponds quite well with clinical findings. Radial keratotomy reverses the natural asphericity of the cornea. Photorefractive keratotomy (PRK) also changes asphericity, Q increasing to an oblate value. These changes might increase spherical aberration, explaining some postoperative deficiencies. Current excimer laser protocols ignore asphericity, relying on paraxial algorithms alone. New strategies to control asphericity in order to diminish spherical aberration may offer solutions. The original conic section models were made to improve the geometry of contact lenses. Understanding of asphericity is important in adaptation after refractive surgery. Modification of spherical aberration by contact lenses and corneal warpage induced by rigid lenses have also been studied. CONCLUSION: The approximation of the corneal surface by a conic section allows understanding of corneal asphericity and offers a quantitative description. This allows a more precise description of the corneal surface and of the genesis of certain optical aberrations of the eye.

Cornea↗

Effect of cutting second-order chordae on in-vivo anterior mitral leaflet compound curvature.

BACKGROUND AND AIM OF THE STUDY: Leaflet curvature determines leaflet stress. In order to assess the influence of second-order chordae (2 degrees CT) on anterior mitral valve leaflet (AMVL) geometry, AMVL curvature was measured before (Baseline) and after (CUT) cutting the 2 degrees CT. METHODS: Miniature radiopaque markers were sutured onto the AMVL in eight sheep: four along the central-meridian from mid-septal annulus to the free-margin; and one each at the 2 degrees CT insertion. Biplane videofluoroscopic data were acquired (open-chest) before and after CUT. Marker-triplet 3-D coordinates were used to calculate radii-of-curvature at LVPmax along the central-meridian (ROCm) and across the AMVL belly (commissure-commissure axis, ROCc-c). RESULTS: CUT did not change LVPmax (111 +/- 12 versus 106 +/- 11 mmHg; p = 0.19). At baseline, the AMVL central-meridian had compound curvature: Convex to the left ventricle near the annulus (-ROCm) and concave near the free-margin (+ROCm). After CUT, the AMVL flattened: ROCm increased near the annulus (from -1.37 +/- 0.52 to -12.58 +/- 29.04 cm; p = 0.02), but did not change near the edge. In the commissure-commissure axis, ROCc-c was concave to the left ventricle at baseline and increased after CUT in all eight animals. In five sheep, ROCc-c was increased (from 1.93 +/- 1.01 to 2.80 +/- 1.36 cm; p = 0.03), but in three sheep ROCc-c was increased and inverted (from 3.65 +/- 2.17 to -1.72 +/- 0.53 cm; p = 0.03), becoming convex to the left ventricle. CONCLUSION: Compound curvature along the AMVL central-meridian appears to be an intrinsic leaflet property that persists even without support from second-order chordae, whereas concave curvature in the commissure-commissure axis is more dependent on intact second-order chordae. Leaflet compound curvature must be incorporated into future finite element models to characterize leaflet stresses accurately. The importance of second-order chordae in maintaining leaflet shape must be considered during mitral repair. A larger ROC increases leaflet stresses, while reversal of ROC changes tensile stress to compressive stress; this might trigger deleterious leaflet remodeling after chordal cutting.

Animals↗

[Astigmatism in corneal graft. Prevention and treatment].

The tremendous development of the photokeratoscope and corneal topography analysis explains the development of corneal astigmatism study in corneal graft. Our study consists in a review of the bibliography. The prevention of the astigmatism needs the following: before the trephination, the astigmatism has to be treated (correction of against the rule astigmatism which is usual in the aphake people); during the trephination, to minimize the deformation of the eye ball, to choose a good diameter for the keratoconus case, to use a pneumatic trephine in order to have a perpendicular cut (the use of the laser Excimer seams promising); The suture of the corneal graft can be done with a double running suture 10/0 and 11/0. The 10/0 is removed at the third month, the visual recovery is faster but the average astigmatism is not as good as with the interrupted 10/0 sutures and running suture 11/0. This technique is good for an old patient or a one eyed people specially interested in a faster recovery of visual acuity. The second possibility is to use 16 interrupted sutures with and 11/0 running suture. With this technique, the sutures are removed selectively depending on the keratometry and the photokeratoscopy. The visual recovery is longer but the astigmatism at the end is very low. When all the sutures have been removed, the residual astigmatism can be treated when there is not any misalignement between the cornea and the graft. The keratometry, photokeratoscopy allows to find the meridian which is abnormal and to find out if the astigmatism is symmetrical or asymmetrical. The astigmatism is symmetrical if the deformation is the same at either side of the meridian. When the abnormal meridian is the steepest, the only thing to do is a relaxing incision (one or two if is asymmetric, two if the astigmatism is symmetric). The size of the relaxing incision is determined by the photokeratoscopy and the deepness by the effect obtained during surgery looking at a qualitative keratometer. On the table, the effect must be about 50% of over correction. When, the abnormal meridian is the flattest, the only thing to do is a wedge resection (if the astigmatism is asymmetric) or two wedge resections (if the astigmatism is symmetric). The size of the cuneiform resection is choosen with photokeratoscopy. The study of the literature about the Ruiz incision adapted to corneal graft cannot nowadays conclude to the accuracy and safety of this technique.(ABSTRACT TRUNCATED AT 400 WORDS)

Astigmatism↗

Class-specific cell death shapes the distribution and pattern of central projection of cat retinal ganglion cells.

The development of the nasotemporal division in cat retina was studied. We find that in the normally pigmented neonatal cat significant numbers of ganglion cells of all types in temporal retina project to the contralateral dorsal lateral geniculate nucleus (LGNd); far fewer cells in temporal retina project contralaterally to the LGNd in the normal adult. Thus, most of these cells must be eliminated during development. Experimental interruption of one optic tract in the neonate results in the retrograde degeneration of the ipsilaterally projecting ganglion cells in the temporal retina ipsilateral to the lesion. Consequent to the loss of the ipsilaterally projecting cells in this hemiretina, many of the ganglion cells projecting to the intact contralateral LGNd, which are normally eliminated, survive. Also, unlike in the normal cat, in which very few of the small ganglion cells in temporal retina project contralaterally to the thalamus, in optic tract sectioned (OTX) cats, significant numbers of the smallest ganglion cells in the temporal retina ipsilateral to the lesion project contralaterally to the intact thalamus. In order to make a quantitative comparison of the distributions of ipsilaterally and contralaterally projecting cells in the temporal retinae of normal cats, OTX cats, and neonatal kittens, it was necessary to determine the position of the vertical meridian in all animals. We defined the vertical meridian as the median edge (Stone, 1966). The median edge was determined from the distribution of the most nasally located, ipsilaterally projecting cells in temporal retina. The results indicate that the angle of the vertical meridian (median edge) with respect to the area centralis and optic disc is specified before birth and does not differ in normal cats, OTX cats, or neonatal kittens. Since the location of the vertical meridian does not change with age in postnatal life and is not affected by optic tract section, corresponding regions of retina in the different groups could be compared. A quantitative analysis of ganglion cell density in the temporal retina contralateral to the section, ipsilateral to the intact hemisphere, indicated that there was a reduction in the population of ipsilaterally projecting ganglion cells that was complementary to the abnormally large number of contralaterally projecting cells surviving in the temporal retina ipsilateral to the lesion.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Functional properties of parietal visual neurons: radial organization of directionalities within the visual field.

Parietal visual neurons (PVNs) were studied in waking monkeys as they executed a simple fixation-detection task. Test visual stimuli of varied direction, speed, and extent were presented during the fixation period; these stimuli did not control behavior. Most PVNs subtend large, bilateral receptive fields and are exquisitely sensitive to stimulus motion and direction but insensitive to stimulus speed. The directional preferences of PVNs along meridians are opponently organized, with the preferred directions pointing either inward toward or outward away from the fixation point. Evidence presented in the preceding paper (Motter et al., 1987) indicates that opponent directionality along a single meridian is produced by a feed-forward inhibition of 20 degrees-30 degrees spatial extent. The observations fit a double-Gaussian model of superimposed but unequal excitatory and inhibitory receptive fields: When the former is larger, inward directionality results; when smaller, outward directionality results. We examine here the distribution of the meridional directional preferences in the visual field. Tests showed that opponent organization is not produced by differences in local directional properties in different parts of the receptive field. The distribution of response intensities from one meridian to another is adequately described by a sine wave function. These data indicate a best radial direction for each neuron with a broad distribution of response intensities over successive meridians. Thus, any single PVN, with rare exceptions, cannot signal radial stimulus direction precisely. We then determined how accurately the population response predicted radial stimulus direction by the application of a linear vector summation model. The resulting population vector varied from stimulus direction by an average of 9 degrees. Whether or not the perception of the direction of motion depends upon a population vector remains uncertain. PVNs are especially sensitive to object movement in the visual surround, particularly in the periphery of the visual field. This, combined with their large receptive fields and their wide but flat sensitivity to stimulus speed, makes them especially sensitive to optic flow. This is discussed in relation to the role of the parietal visual system in the visual guidance of projected movements of the arm and hand, in the guidance of locomotion, and in evoking the illusion of vection.

Action Potentials↗

A mutant of Tetrahymena thermophila with a partial mirror-image duplication of cell surface pattern. II. Nature of genic control.

The CU-127 clone of Tetrahymena thermophila, which manifests an unusually high number of ciliary rows plus a second set of abnormal oral structures and of contractile vacuole pores with partial mirror-image reversal of asymmetry (Jerka-Dziadosz & Frankel, 1979), has been subjected to breeding analysis. The progeny ratios obtained in various crosses indicate that the abnormalities of cell-surface asymmetry are brought to expression as a result of the action of a recessive allele at a single gene locus, here named janus. When previously normal cells were made homozygous for the jan allele, the cortical pattern characteristic of the CU-127 clone came rapidly to expression, often without associated change in number of ciliary meridians. Conversely, when cells previously expressing jan re-acquired the wild-type (jan+) allele, they returned to the normal pattern of a single normal oral structure and a single normally located set of contractile vacuole pores while still retaining the high ciliary meridian number characteristic of the original CU-127 clone. The capacity for manifestation of the unique asymmetry pattern depends solely on homozygous expression of the janus allele, whereas the stable number of ciliary meridians in janus clones and the degree of expression of secondary OAs is modulated by other factors, probably at least in part genic. These results, taken together with those of the preceding paper, indicate that the janus allele promotes the propagation and/or expression of a condition of reversed asymmetry in a precisely located cell region, and further indicates that the propagation and expression of this condition are largely independent of the number and asymmetry of ciliary meridians.

Alleles↗

Meridional variations in orientation discrimination in normal and amblyopic vision.

Orientation discrimination for single long lines presented in a frameless environment was measured with a method of constant stimuli in 18 normal subjects and in both eyes of 9 amblyopes. Orientation discrimination was tested at four meridians (horizontal, vertical, left, and right oblique). Although the normal subjects showed considerable individual variability in their just noticeable differences in orientation, each subject showed a consistent oblique effect. In amblyopic subjects, the interocular differences were strongly meridian-dependent and individually variable. Across amblyopic subjects, a two-fold increase in just noticeable differences ( JNDs ) was observed for the principal meridians, while the impairments were not significant for the oblique meridians. These small impairments in orientation discrimination strongly contrast with the high losses in acuity for the same subjects, which suggests that different mechanisms underly acuity and orientation discrimination.

Adolescent↗