Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Maximum Allowable Concentration”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

[Principles of air sampling and interpretation of its results in evaluating occupational exposure to toxic substances in the work area. II. Stationary measurements].

The paper presents the principles of performing stationary measurements for the assessment of occupational exposure to toxic substances. A classification of work-stands was introduced according to the length of time spent at them. The strategy of measurements was adapted to the type of a given work-stand. The interpretation of measurement results was based on the exposure factors, relevant for a specific work-stand. Also, the principles of air sampling and of the interpretation of the results of the evaluation of instantaneous and threshold concentrations are discussed.

Air Pollutants, Occupational↗

Therapeutic drug monitoring of clozapine treatment. Therapeutic threshold value for serum clozapine concentrations.

It has been suggested that the minimum effective serum clozapine concentration for an acceptable clinical response (threshold value) is about 400 micrograms/L. This article argues against the use of therapeutic drug monitoring (TDM) as a tool to obtain clozapine concentrations of > or = 400 micrograms/L in the individual patient from the start of clozapine treatment. The following arguments are presented: (i) because of a great interindividual variability of the clozapine concentration to dose ratio (C/D) it can be calculated that extremely high daily doses (900 to 1800 mg/day) would be necessary in 15% of patients to obtain a clozapine concentration of 400 micrograms/L; (ii) doses of 200 to 300 mg/day are commonly used in Central Europe. although about 80% of the patients can be expected to have clozapine concentration < 400 micrograms/L; (iii) in a double-blind study, no difference in clinical response was found between patients treated with clozapine in the concentration range of 200 to 300 micrograms/L, and a group with higher clozapine concentrations; (iv) positron emission topography (PET) studies indicate that maximum receptor occupancy is obtained at clozapine concentrations of about 200 micrograms/L and no further receptor occupancy is obtained by increasing clozapine concentrations to > or = 400 micrograms/L; (v) the frequency of both severe clozapine-induced adverse effects (seizure and confusion) and more common adverse effects increases with increasing doses/clozapine concentrations. It is concluded that the antipsychotic effects and adverse effects of clozapine occur over a very broad range of serum concentrations. In most countries the majority of patients are treated with clozapine concentrations well below the 400 micrograms/L suggested as threshold concentration for optimum response. Therefore clinical judgement should always be primarily used for dose adjustments. TDM is useful to follow compliance and to adjust for extreme serum concentrations and revealing drug interactions.

Antipsychotic Agents↗

[Decreasing the emission of pollutants in laboratory waste water by substitution of trichloromethane].

Working up great test series to determine chloroform-extractive substances and tensides, increased trichlormethane concentrations can appear in the laboratory air-inspite of realization of numerous precautionary measures. As a rule the MAKD rate will be exceeded than. Various precautions failed to fulfill their purpose so that the solvent trichlormethane had been replaced by other solvents. Two demands mainly influenced on this replacement. The risk to health must be decreased so far that the work with solvents can be performed without any difficulties. The correlation between methods of determination must-on the other hand-be a reliable one. Trichlortrifluorethane is especially suited for the determination of extractive substances, dichlormethane for those of AAT (MBAS). The MAK rates can be observed with utilization of both the solvents. The reliable correlation of the concentration ascertained could be proved.

Air Pollutants, Occupational↗