Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Leachate”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Analysis of Microbial Communities in a Landfill Leachate Polluted Aquifer using a New Method for Anaerobic Physiological Profiling and 16S rDNA Based Fingerprinting.

Databases containing information regarding presence and activity of microbial communities will be very useful for determination of the potential for intrinsic bioremediation in landfill leachate polluted aquifers. Simple analyses such as community-level physiological profiling (CLPP) and denaturing gradient gel electrophoresis (DGGE) of 16S rDNA fragments yield large sets of data for inclusion into such databases. In this study we describe the development of a method for anaerobic CLPP, using commercially available Biolog plates. Incubation at the in situ temperature of the aquifer (10 degrees C) for 28 days was optimal for obtaining a specific, reproducible physiological profile. Anaerobic incubation was essential for profiling anaerobic communities. The anaerobic cultivation-dependent CLPP method and cultivation-independent DGGE were applied to groundwater and sediment samples from the aquifer near the Coupépolder landfill in The Netherlands. A combination of computer-assisted CLPP and DGGE analysis of both groundwater and sediment samples yielded the best separating power for characterizing microbial communities in the aquifer. Communities in groundwater were significantly different from those in the corresponding sediment. Microbial communities present in subsamples from sediment cores usually were similar for the various sampling locations. Variation was observed for the heterogeneous sediment beneath the landfill. Both anaerobic CLPP and DGGE analysis clearly separated microbial communities from the polluted aquifer underneath the landfill from those in the less or not polluted aquifer downstream and upstream of the landfill.

Journal Article↗

Kinetics of nitrogen removal from sanitary landfill leachate.

Leachates from municipal landfill 'Lublinek' in Lodz city (Poland) were treated in two-sludge sequence batch reactor systems (type ND). The external carbon source--sodium acetate was used in denitrification. Two versions were tested--with and without supernatant recirculation from D-SBR to N-SBR. The 99% removal of inorganic nitrogen compounds was achieved in both versions. Due to recirculation, the buffering (by means of sodium bicarbonate) was not necessary. Kinetic models for nitrification and denitrification processes were proposed. Kinetic parameters of the models were estimated by the optimization method. The experimental results of both nitrification steps (oxidation of ammonia to nitrites and nitrites to nitrates) were best fitted with the interactive limitation model of nitrogen compounds and oxygen. The denitrification process was limited only by the concentration of nitrogen compounds.

Bioreactors↗

Inorganic nitrogen transformations in the treatment of landfill leachate with a high ammonium load: A case study.

The inorganic nitrogen transformations occurring at a municipal waste leachate treatment facility were investigated. The treatment facility consisted of a collection well and an artificial wetland between two aeration ponds. The first aeration pond showed a decrease in ammonium (from 3480 (+/- 120) to 630(+/- 90) mg x L(-1)), a reduction in inorganic nitrogen load (3480 to 1680 mg N x L(-1)), and an accumulation of nitrite (< 1.3 mg-N x L(-1) in the collection well, to 1030 mg-N x L(-1)). Incomplete ammonium oxidation was presumably the result of the low concentration of carbonate alkalinity (approximately 2 mg x L(-1)), which may cause a limitation in the ammonium oxidation rate of nitrifiers. Low carbonate alkalinity levels may have been the result of stripping of CO(2) from the first aeration pond at the high aeration rates and low pH. Various chemodenitrification mechanisms are discussed as the reason for the reduction in the inorganic nitrogen load, including; the reduction of nitrite by iron (II) (producing various forms of gaseous nitrogen); and reactions involving nitrous acid. It is suggested that the accumulation of nitrite may be the result of inhibition of nitrite oxidizers by nitrous acid and low temperatures. Relative to the first aeration pond, the speciation and concentration of inorganic nitrogen was stable in the wetlands and 2nd aeration pond. The limited denitrification in the wetlands most probably occurred due to low concentrations of organic carbon, and short retention times.

Alkalies↗

Effect of different salt leachates on the movement of some phosphorus containing pesticides in soils using thin layer chromatography.

The influence of pH, leachates of alkaline and saline salts, inorganic fertilizers, and surfactants on the movement of eight organophosphorus pesticides, viz., DDVP, diazinon, Ekatin, Folithion, malathion, metasystox, parathion methyl, and Rogor has been studied using soil thin layer chromatographic techniques. The variation in the movement of pesticides under different solvent amendments are expressed in terms of Rf, RB, and RM values and are explained on the basis of adsorption and leachability.

Carbonates↗

The containment of toxic wastes: II. Metal movement in leachate and drainage at Parc lead-zinc mine, North Wales.

Nant Gwydyr, a tributary of the River Conwy in North Wales, has been affected by metal wastes, from a lead and zinc mine, Parc Mine, through contaminated mine drainage waters and episodal erosion of an unstable tailings heap. From 1954 when the mining operation was discontinued to 1978 when a reclamation programme aimed to stabilise the tailings was accomplished, 13 000 tonnes of metalliferous spoil, containing 43 tonne Pb, 104 tonne Zn, and 1 tonne Cd was eroded from the main tailings dam. Dispersal and redeposition during flood events caused extensive pollution of the agricultural land of the flood plain. Analysis of the present water quality of the Nant Gwydyr, 14 years after the stabilisation work, shows that although there has been a marked improvement and no particulate matter is released, the Nant Gwydyr is still a polluted stream. Under normal discharge conditions, it contributes approximately 1 tonne of Zn, 0.2 tonne of Pb and 0.05 tonne of Cd per year to the River Conwy. Most of this originates from water issuing from the mine adit which has been impossible to control. There is still, however, a major contribution by the leachate from the tailings heap, because the stabilisation method used does not prevent this. The control of pollution in mine drainage is discussed.

Journal Article↗

Sex steroids in the female zebrafish (Danio rerio). Effects of cyproterone acetate and leachate-contaminated sediment extract.

In Molnbyggen, a leachate-contaminated lake in Sweden, effects on the reproductive system of perch included a decreased frequency of sexually mature female perch, reduced gonadosomatic index and decreased plasma levels of androstenedione and testosterone, but the contaminants responsible for these effects have not yet been identified. A biomarker-directed fractionation approach could be used to narrow the search for the compound(s) responsible for the adverse effects in Molnbyggen female perch. Thus, it is important to develop and test a suitable biomarker, which can be used in this type of approach. We evaluated if decreased concentrations of sex steroids could work as an in vivo end-point in female zebrafish fed an organic extract of bottom sediments from Molnbyggen. The responsiveness of zebrafish to endocrine alteration was evaluated using a positive control substance, cyproterone acetate (CA), which is known to inhibit steroid biosynthesis. After the 21-day exposure period the concentrations of testosterone (T) and estradiol (E2) were successfully determined by HRGC/HRMS in whole-body homogenates of individual fish. Median T concentrations were 1.7pmol/g fish in controls and were decreased after exposure both to CA (0.55pmol/g fish) and Molnbyggen sediment extract (1.2-1.3pmol/g fish). Median E2 concentrations were 5.3pmol/g fish in controls and were decreased after CA exposure (2.3pmol/g fish) and after exposure to Molnbyggen sediment extract (4.0-4.5pmol/g fish). This suggests that sex steroid concentrations in zebrafish are responsive to endocrine alteration and indicates that compounds with endocrine altering potency are present in Molnbyggen sediments.

Androgen Antagonists↗

Nitrogen mass balance and microbial analysis of constructed wetlands treating municipal landfill leachate.

Experiments were conducted to investigate the feasibility of applying constructed wetlands to treat a sanitary landfill leachate containing high nitrogen and bacterial contents. Under a tropical condition (temperature of about 30 degrees C), the constructed wetland units operating at the hydraulic retention time of 8d yielded the best treatment efficiencies with BOD(5), TN and fecal coliforms removal of 91%, 96% and more than 99%, respectively. Cadmium removal in the SFCW bed was 99.7%. Mass balance analysis, based on total nitrogen contents of the plant biomass and dissolved oxygen and oxidation-reduction potential values, suggested that 88% of the input total nitrogen were uptaken by the plant biomass. Fluorescence in situ hybridization results revealed the predominance of bacteria, including heterotrophic and autotrophic, responsible for BOD(5) removal. Nitrifying bacteria was not present in the constructed wetland beds.

Bacteria↗

Treatment and detoxification of a sanitary landfill leachate.

The leachate from an old sanitary landfill (Gramacho Metropolitan Landfill, Rio de Janeiro) was characterized and submitted to coagulation and flocculation treatment followed by ozonation and ammonia stripping. The performance of the treatment was assessed by monitoring the removal of organic matter (COD and TOC), ammonium nitrogen and metals. Detoxification was assessed by determining acute toxicity, using the following organisms: Vibrio fisheri, Daphnia similis, Artemia salina and Brachydanio rerio. Membrane fractionation was employed to infer the range of molecular masses of the pollutants found in the effluent, as well as the toxicity associated to these fractions. Of the techniques under investigation, coagulation and flocculation followed by ammonia stripping were the most effective for toxicity and ammonium nitrogen removal. Membrane fractionation was effective for COD removal; however, acute toxicity was almost the same in all the fractionated samples. Ozonation was moderately effective for COD removal, but significant toxicity removal was only attained when high ozone doses were used.

Animals↗

Selective extraction of benzoic acid from landfill leachate by solid-phase extraction and ion-exchange chromatography.

In this work a simple method was described for selective extraction of benzoic acid from landfill leachate samples. The samples were submitted to solid-phase extraction (SPE) with XAD-4 resin as the stationary phase and ion-exchange chromatography (IEC) using the ion-exchange resin Amberlyst A-27. The instrumental analysis was performed by gas chromatography with mass spectrometric detection (GC-MSD). Benzoic acid was isolated, identified and quantified. The extraction process is rapid, simple and of low cost. It was also environmental friendly, that is, it was used a minimum amounts of hazardous organic solvents and produced also minimum quantities of residues.

Benzoic Acid↗

Seasonal testosterone UDP-glucuronosyltransferase activity and biliary steroids in Eurasian perch: response to leachate exposure.

In previous studies there was evidence of endocrine disruption in fish in waterways contaminated with leachate from a Swedish landfill. Symptoms included fewer sexually mature (SM) female perch (Perca fluviatilis), distinct sores, reduced gonadosomatic index, and decreased plasma androgen levels. Based on previous findings it was hypothesized that the decrease in plasma androgen concentrations could have been caused by increased steroid excretion. Therefore, testosterone UDP-glucuronosyl transferase (UDPGT) activity and biliary steroids were measured in SM and sexually immature (SIM) female perch during one reproductive cycle. UDPGT activity in exposed fish did not differ from reference fish and was similar in both SM and SIM female perch. Since androgen levels in SIM fish usually are much lower than in SM fish, this indicates expression of testosterone UDPGT irrespective of substrate availability. There was no general increase in biliary steroids in exposed female perch. Biliary steroid levels correlated with corresponding plasma steroid levels. In conclusion, the reduced androgen levels in exposed female perch are most likely not caused by increased steroid excretion.

Animals↗

Toxicity of tire debris leachates.

Data on the indicators of environmental impact of tire debris, originated from the tire abrasion on roads, are extremely scarce, while it is well known that tires may produce deleterious effects. Tire debris contains significant quantities of zinc (Zn) which may be released by tire rubber. We have used tire particles (TD) produced in laboratory from new rubber. Two sets of experiments were set up to obtain eluates. One set used 50 and 100 g/L TD to produce eluates at pH 3-7. The Zn quantity was measured with a Inductively Coupled Plasma-Atomic Emission Spectrometry. The eluates at 1%,10%,50%,100% concentrations in culture media were tested on Raphidocelis subcapitata, Daphnia magna and Xenopus laevis embryos (FETAX test). The other set of experiments was performed putting 250 mg/L TD in a column with glass beads to control particle dispersion during the elution process. We demonstrate that factors such as pH, size and particles aggregation deeply influence the elution process, that the amount of Zn leached from particles is related to their aggregation rather than their quantity. These results, even though do not reflect the real environmental toxicity of the leachates, can be successfully used for comparative purposes allowing an initial assessment of the potential effect of tire derived particles.

Animals↗

Molecular phylogenetic diversity of bacteria associated with the leachate of a closed municipal solid waste landfill.

A 16S rDNA-based molecular study was performed to determine the nature of the bacterial constituents of the leachate from a closed municipal solid waste landfill. Total community DNA was extracted and bacterial 16S rRNA genes were subsequently amplified and cloned. Recombinant rDNA clones in the library were randomly selected, and they were sequenced for a single run and then grouped. A total of 76 sequence types representing 138 randomly selected nonchimeric clones were identified. Full-length sequencing and phylogenetic analysis of the sequence types revealed that more than 90% of the screened clones were affiliated with low-G+C gram-positive bacteria (38.4%), Proteobacteria (35.5%), the Cytophaga Flexibacter Bacteroides group (11.6%), and Spirochaetes (5.1%). Minor portions were affiliated with Verrucomicrobia (2.9%), candidate division OP11 (2.2%), and the green nonsulfur bacteria, Cyanobacteria and the Deinococcus Thermus group (each <1.0%). Although some rDNA sequences clustered with genera or taxa that were classically identified within anaerobic treatment systems and expected with known functions, a substantial fraction of the clone sequences showed relatively low levels of similarity with any other reported rDNA sequences and thus were derived from unknown taxa. These results suggest that bacterial communities in landfill environment are far more complex than previously expected and remain largely unexplored.

Bacteria↗

Identification of a reactive degradation zone at a landfill leachate plume fringe using high resolution sampling and incubation techniques.

Vertical small-scale variation in phenoxy acid herbicide degradation across a landfill leachate plume fringe was studied using laboratory degradation experiments. Sediment cores (subdivided into 5 cm segments) were collected in the aquifer and the sediment and porewater were used for microcosm experiments (50 experiments) and for determination of solid organic carbon, solid-water partitioning coefficients, specific phenoxy acid degraders and porewater chemistry. Results from a multi-level sampler installed next to the cores provided information on the plume position and oxygen concentration in the groundwater. Oxygen concentration was controlled individually in each microcosm to mimic the conditions at their corresponding depths. A highly increased degradation potential existed at the narrow plume fringe (37.7 to 38.6 masl), governed by the presence of phenoxy acids and oxygen. This resulted in the proliferation of a microbial population of specific phenoxy acid degraders, which further enhanced the degradation potential for phenoxy acids at the fringe. The results illustrate the importance of fringe degradation processes in contaminant plumes. Furthermore, they highlight the relevance of using high-resolution sampling techniques as well as controlled microcosm experiments in the assessment of the natural attenuation capacity of contaminant plumes in groundwater.

Environmental Monitoring↗

Stabilized leachates: sequential coagulation-flocculation + chemical oxidation process.

The combined sedimentation-chemical oxidation treatment of medium-stabilized landfill leachates has been investigated. The sequence of stages implemented was: (a) coagulation-flocculation by pH decrease (pH 2) to acidic conditions (COD removal approximately 25% related to COD0 approximately 7500 ppm); (b) coagulation-flocculation by Fe(III) addition (0.01 M) at pH 3.5 (COD removal approximately 40% related to COD of supernatant after step (a); (c) Fenton (Fe(III) = 0.01 M; H2O2 = 1.0 M) oxidation (COD removal approximately 80% related to COD of supernatant after step (a); and (d) coagulation-flocculation of Fenton's effluent at pH 3.5 (COD removal approximately 90% related to COD of supernatant after step (a). The use of Kynch theory allows for the design of clarifiers based on the amount of solids fed. For a general example of 1000 m3 day(-1) of a feeding stream, clarifier area values of 286,111 and 231 m2 were calculated for compacting indices of 3.7, 2.67 and 2.83 corresponding to the first, second and third consecutive sedimentation processes, respectively, (steps (a), (b) and (d)).

Environmental Pollution↗

Monitoring of leachate at a test road using treated fly ash from municipal solid waste incinerator.

A treatment process for municipal solid waste incinerator fly ash has been jointly developed by the Université Libre in Brussels and the Solvay company. This experimental process has led to an experimental project with a multi-disciplinary team from Solvay along with several companies and organisations, plus support from the ADEME agency. After a laboratory assessment of the treated fly ash (TFA), its environmental properties and the optimal fields of application in road construction, as part of the Revasol project, a full-scale analysis was organised for both environmental and mechanical purposes. A test section using TFA was designed in order to collect percolation water; TFA was used as a road base component (a cement-bound graded aggregate containing 12% TFA). A reference section with the same structure was also built using natural materials. After a description of the treatment process and the test road design, the main TFA characteristics are presented. Then, the environmental behaviour of both sections over a 1-year period following construction is detailed: infiltration, leachate quality, cumulative release. This monitoring effort highlights not only the evolution in TFA behaviour, but also the general permeability of the road structure to various external influences.

Carbon↗

Use of advanced oxidation processes to improve the biodegradability of mature landfill leachates.

Two advanced oxidative processes (Fe2+/H2O2/UV and H2O2/UV systems) were used for the pre-treatment of mature landfill leachate with the objective of improving its overall biodegradability, evaluated in terms of BOD5/COD ratio, up to a value compatible with biological treatment. At optimized experimental conditions (2000 mgL(-1) of H2O2 and 10 mgL(-1) of Fe2+ for the photo-Fenton system, and 3000 mgL(-1) of H2O2 for the H2O2/UV system), both methods showed suitability for partial removal of chemical oxygen demand (COD), total organic carbon (TOC) and color. The biodegradability was significantly improved (BOD5/COD from 0.13 to 0.37 or 0.42) which allowed an almost total removal of COD and color by a sequential activated sludge process. In addition, gel permeation chromatography (GPC) has showed a substantial agreement on the cleavage of large organic compound into smaller ones.

Biodegradation, Environmental↗

Adsorption of landfill leachates onto activated carbon. Equilibrium and kinetics.

The adsorption of stabilized leachates generated in a municipal landfill onto three commercial activated carbons has been investigated. Norit 0.8, Chemviron AQ40 and Picacarb 1240 have been used as adsorbents. Equilibrium experiments have been conducted to obtain the experimental isotherm profiles. Isotherms have been plotted based on the adsorption of general parameters, for instance chemical oxygen demand, total carbon, absorption at 410 nm and absorption at 254 nm. Different literature models and error functions have been used to adequately fit the experimental data. As a rule of thumb, three-parameter models do adjust experimental results better than two-parameter models. Norit 0.8 shows better adsorption characteristics than the rest of activated carbons, both in terms of contaminant level reduction of per unit mass of absorbent and in terms of the process kinetics.

Adsorption↗

Leaching of chromated copper arsenate (CCA)-treated wood in a simulated monofill and its potential impacts to landfill leachate.

The proper end-of-life management of chromated copper arsenate (CCA)-treated wood, which contains arsenic, copper, and chromium, is a concern to the solid waste management community. Landfills are often the final repository of this waste stream, and the impacts of CCA preservative metals on leachate quality are not well understood. Monofills are a type of landfill designed and operated to dispose a single waste type, such as ash, tires, mining waste, or wood. The feasibility of managing CCA-treated wood in monofills was examined using a simulated landfill (a leaching lysimeter) that contained a mix of new and weathered CCA-treated wood. The liquid to solid ratio (LS) reached in the experiment was 0.63:1. Arsenic, chromium, and copper leached from the lysimeter at average concentrations of 42 mg/L for arsenic, 9.4 mg/L for chromium, and 2.4 mg/L for copper. Complementary batch leaching studies using deionized water were performed on similar CCA-treated wood samples at LS of 5:1 and 10:1. When results from the lysimeter were compared to the batch test results, copper and chromium leachability appeared to be reduced in the lysimeter disposal environment. Of the three metals, arsenic leached to the greatest extent and was found to have the best correlation between the batch and the lysimeter experiments.

Arsenates↗