Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Lower extremity above-knee prosthesis-associated erectile dysfunction.

Blunt pelvic and perineal trauma has been previously reported to result in site-specific veno-occlusive dysfunction and/or site-specific cavernosal artery insufficiency. We herein describe a case of erectile dysfunction in a young previously potent amputee. We postulate that the erectile dysfunction is associated with a newly described form of blunt trauma, that is, site-specific compression from a perineal weight-bearing lower extremity above-knee prosthetic device. It is hypothesized that when the force exerted by the above-knee prosthesis is directed medially towards the ischiopubic ramus, the penile crura and common penile arterial blood supply become susceptible to crush-like injury, since they are in fixed anatomic locations in the perineum sandwiched between the compressive force and the bone. Clinical evaluation of the erectile dysfunction in this patient revealed site-specific corporal veno-occlusive dysfunction and site-specific common penile arterial occlusive pathology in the precise region of the contact of the above-knee prosthesis with the perineum. Further research is needed in above-knee prosthesis design to prevent erectile dysfunction.

Adult↗

Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study.

BACKGROUND: The restoration of posterior femoral translation has been shown to be an important factor in enhancing knee flexion after total knee arthroplasty. The purpose of this study was to compare the ranges of motion associated with standard and high-flexion posterior stabilized total knee prostheses in patients managed with simultaneous bilateral total knee arthroplasty. METHODS: Fifty patients (mean age, sixty-eight years) received a standard fixed-bearing knee prosthesis in one knee and a high-flexion fixed-bearing knee prosthesis in the contralateral knee. Two patients were men, and forty-eight were women. At a mean of 2.1 years postoperatively, the patients were assessed clinically and radiographically with use of the knee-rating systems of the Knee Society and The Hospital for Special Surgery. RESULTS: The mean postoperative Hospital for Special Surgery knee score was 90 points for the knees treated with the standard fixed-bearing prosthesis and 89.4 points for those treated with the high-flexion prosthesis. At the time of the final follow-up, the knees with the standard prosthesis had a mean range of motion of 135.8 degrees (range, 105 degrees to 150 degrees ) and those with a high-flexion prosthesis had a mean range of motion of 138.6 degrees (range, 105 degrees to 150 degrees ) (p = 0.41). No knee had aseptic loosening, revision, or osteolysis. CONCLUSIONS: After a minimum duration of follow-up of two years, we found no significant differences between the groups with regard to range of motion or clinical and radiographic parameters, except for posterior femoral condylar offset.

Aged↗

[Intracondylar knee joint prosthesis with rotation capacity- Endo model].

The St. Georg total knee prosthesis has been modified to incorporate axial rotation of the tibial component. The kinematics approximate more those of the normal knee and the stress imposed at the bone-cement interface are attenuated, thus reducing the risk of mechanical failure. The construction and laboratory testing are described.

Biomechanical Phenomena↗

[Is the implantation of hinged knee joint prostheses still justifiable today? 15 years' experience using the Blauth knee joint prosthesis].

In objection to knee hinge prostheses there is often mentioned a higher complication rate. An increased load impact on the bone-cement interface results from the close connection of tibial and femoral components. This is assumed to cause bad results, as reported from early artificial knee joint replacements, characterised by weight bearing axes and direct contact metal to metal. These are contrasted to long term results of the Blauth hinge prosthesis. The Blauth prosthesis is constructed according to the low friction principle without a weightbearing axis. A prospective multicentric long term follow-up study reports on 556 prostheses. 463 (83%) were controlled between 1 and 15 years after operation (average: 43 months). Aseptic loosenings had to be confirmed in 1.3% of the patients, deep infections in 2.6%. The survival analysis did not show an erratic deterioration in dependence of the observation period. After 10 years there is still a probability of 89% that a prosthesis does not show a deep infection or loosening. The efficiency of artificial knee joint replacement by hinge joints should therefore not be judged on the results of the first generation of these models.

Adult↗

Segmental cement extraction system (SEG-CES) and the Ilizarov method in limb salvage procedure after total knee cemented prosthesis removal in a former osteosarcoma patient.

Survival of osteosarcoma has greatly improved in the past few decades. Knee prosthesis is a well-recognized limb salvage procedure for osteosarcoma of the distal end of the femur. One drawback is that prostheses have a limited life and prosthetic failure with the inherent high rate of reoperations remains a serious long-term problem for former osteosarcoma patients. The segmental cement extraction system (SEG-CES) is a technique to remove cement in arthroplasty revision, based on a cement-bone interface with a lower strength compared to the old cement-new cement interface. We report the case of a 32-year-old former osteosarcoma patient in whom the SEG-CES was applied to remove a long-stemmed total knee cemented prosthesis. The prosthesis was placed 17 years before for a recurrent telangiectatic osteosarcoma of the left femur. Thirteen years after the prosthesis implantation, the patient complained of knee instability, pain, and complete failure of the extensor apparatus. The extraction of the prosthesis was performed using cylindrical batters of diameter corresponding to the diameter of the axle, two hammer extractors clamping the prosthesis components between two jaws. Extraction of the periprosthetic cement in the femoral and tibial components was done using the SEG-CES technique. The successful prosthesis removal performed in this patient allowed us to perform an external fixation with bone lengthening and reconstruction by the Ilizarov method.

Adult↗

Reduction of orthopaedic wound infections in 21 hospitals.

INTRODUCTION: The German national nosocomial infections surveillance system (KISS) has been collecting surveillance data from hip and knee prosthesis operations since 1997. The purpose of this article is to investigate whether surveillance and feedback of surgical site infection (SSI) information to the physicians and nurses of participating hospitals lead to reduced SSI rates or not. MATERIALS AND METHODS: Only information from hospitals previously participating for at least 3 years was used for the analysis. Monthly SSI rates were pooled over the 36-month period, beginning in each clinic's case with its first month of participation, the rates then being compared for 12-month periods. Relative risks were calculated for comparison of the SSI rates in the first and third years of participation. A multiple logistic regression analysis with stepwise variable selection was performed to identify significant risk factors, including the year of surveillance after starting surveillance activities. RESULTS: The overall SSI rates were 1.4% for hip prosthesis and 1.0% for knee prosthesis. Fourteen clinics participated in KISS for at least 3 years continuously with HIP prostheses and 21 with knee prostheses. It was possible to include a total of 15,457 hip and 9,011 knee procedures for this analysis. A comparison of data from the first and the third years show a significant SSI reduction with hip procedures, with a relative risk of 0.54 (CI95 0.38-0.77), and a trend towards reduced SSI rates for knee procedures. The multiple logistic regression analysis confirmed that the SSI rate for hip prosthesis was significantly lower in the third year than in the first year of surveillance (OR = 0.57; CI95 0.42-0.78), though for knee prosthesis the level of significance was not achieved. CONCLUSION: A reduction of SSIs following hip and knee prosthesis operations through the introduction of ongoing surveillance and the possibility of using benchmark data for comparison does seem to be possible in many institutions.

Hip Prosthesis↗

The effect of a meniscal prosthesis on knee biomechanics and cartilage. An experimental study in rabbits.

A meniscal prosthesis made of Dacron with polyurethane coating was tested as a substitute for the medial meniscus in a rabbit experimental model concentrating on biomechanical behavior of the knee joint and gross and histologic evaluation 3 months after surgery. The results were compared to sham-operated knees, knees with a peripheral incision of the medial meniscus, and knees with a total meniscectomy. Knees with prosthesis implantation had the same stiffness as knees with sham-operation or meniscal incision, but knees with meniscectomy were stiffer (P less than 0.05). Knees with prosthesis showed lower energy storage during relaxation than knees with sham-operation or meniscal incision (P less than 0.05). Energy storage in the prosthesis group was similar to the meniscectomy group. Partial or total ingrowth of synovial tissue into the prosthesis was present in 93%, and 63% of the incised menisci had healed. Cartilage changes were present in 70% of the prosthesis group, in 25% of the knees with meniscal incision, and in all knees with meniscectomy. The sham-operated knees were free from cartilage degeneration. Knees with prosthesis had the same frequency of cartilage changes on the femur, but had less changes on the tibia compared to knees with meniscectomy. A high rate of osteophyte formation was observed after prosthesis implantation as well as following meniscectomy, but the osteophytes were larger in the prosthesis group (P less than 0.01). The most frequent and severe effect on the synovium was found in the prosthesis group (92%), but no foreign body reaction or loose Dacron particles were found.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

[Embolism and intramedullary femoral surgery].

All intramedullary femoral surgery entails embolic phenomena which explain peroperative collapses formally known as bone cement implantation syndrome, as well as perioperative fat embolism syndromes. Locally, the bigger the cavity is, the higher the number of accidents: 2.5-5 per cent for GUEPAR hinged-knee prosthesis, 1.75 per cent for total hip arthroplasty with long stem, and 0.1 per cent during classic THA with cement limited to the metaphysis. Anomalies in bone vascularization also increase risk: 10.5-13 per cent during prophylactic nailing for shaft metastases, 1-11.5 per cent during hemiarthroplasty cemented in osteoporotic bone of femoral neck fractures, and only 0.1 per cent during THA implanted because of arthrosis. Not only cement, but also rods, reamers, nails, implants, ultrasonic tool for cement extraction, increase the pressure inside the cavity. Methylmethacrylate is no longer the only incriminated factor, even if it is responsible for a major part of the compressive load. The intensity and duration of the pressure are correlated with the number of embolic phenomena and with measured cardiopulmonary parameters. The intracavity fat content is expelled (an empty cavity, as in THA revision, does not lead to embolic phenomena). Then filters through the intraosseous veins whose diameter limit the size of the extruded embolic phenomena. The ultrasonography of the inferior vena cava shows innumerable fine particles and thrombi which are already organized under the influence of procoagulant factors released from the operative shield and which remain crumbly. These emboli cross the cardiac cavities. Transesophageal echocardiography (TEE), of recent use, does quantify the amount of right atrial filling, duration of echogenesis and size of particles: the result is higher in patients who underwent cemented versus noncemented THA: however the embolism score is no an indicator of seriousness because it is not correlated with cardiorespiratory manifestations; TEE shows only one fourth of the patent foramen ovale, whereas the atrial septal defect is surely one of the most efficient systemic invasion mechanisms to produce perioperative fat embolism. Lung response is most often asymptomatic, even if all patients undergoing intramedullary surgery display an increase in pulmonary vascular resistance which is managed by the right heart only, as well as pulmonary (and sometimes systemic) microvascular fat obstruction. Common operating room monitoring procedures do not detect successive embolic phenomena before they cause pulmonary arterial hypertension which then has repercussions on the left heart and in turn causes peroperative hemodynamic accidents. Only pulmonary arterial pressure measurement with a Swan-Ganz catheter gives early and durable signs of an intolerance to embolic load. Preventive treatment is surgical as there is an inverse relation between embolic marrow and marrow eliminated by large volume washes (which is often more effective than draining). Cement indications in older patients as well as the choice of fixation techniques in femoral fractures must take into account the cardio-pulmonary condition of the patient. Resuscitation procedures dealing with these complications end in the patient's death in half of the cases.

Animals↗

Turn-up bone flap for lengthening the below-knee amputation stump.

When amputation just below the knee becomes necessary after extensive loss of bone from the tibia and of anterior soft tissue in the treatment of tumours, fractures or infection, the remaining proximal tibia may be too short for a below-knee prosthesis, although the knee may be normal. We have included the distal tibia or foot in a long posterior flap by turning it up thus increasing the length of a very short proximal tibial stump. The knee is thereby saved, allowing satisfactory use of a below-knee prosthesis. This technique is particularly applicable when the distal leg is normal and well vascularised. Five procedures have been undertaken. We present two illustrative cases.

Adolescent↗

[The Interplanta system model knee joint prosthesis. Preliminary results].

The SKI-knee joint is used since three years. Our experiences comprise 220 cases up to now. The follow-up time is still short, but the implant, which is partially designed very close to normal anatomy and on the other hand regards fundamental biomechanical aspects is showing a comparably low incidence of complications. The complications specifically due to the endoprosthetic system sums up to 10%. It is obvious that patellar complications are leading. This fact should be seen in close connexion to the anatomical design of the femoral component. With increasing experience these problems are diminished. Causes and potential elimination of patellar complications are discussed. Surgical procedure, especially advantages in comparison with other knee joints are described. The SKI-System in combination with its aligning instruments allow the surgeon anatomical reconstruction, very exact alignment of the implant and precise correction of preexisting deformities. In general the results are encouraging in comparison with formerly used knee joints after the same follow-up period.

Adult↗

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing.

We compared the early results of mobile-bearing knee prosthesis with fixed-bearing knee prosthesis in 16 patients who had one-stage, sequential, bilateral replacements. In each patient, a Low Contact Stress (LCS, Depuy) rotating-platform prosthesis was inserted in one side, and an Anatomic Modular Knee (AMK, Depuy) posterior-stabilised prosthesis was inserted in the other side. The same surgical routines were adopted for both sides in each patient. There were significant improvements in the Knee Society knee score and functional score, as well as the Oxford Knee score after both mobile-bearing and fixed-bearing knee replacements (p<0.001). However, we could not find any significant difference between the clinical results of the two prostheses. The authors early experience with the mobile-bearing total knee prosthesis was as favourable as the medium-term experience of the fixed-bearing total knee prosthesis in this prospective, match-pair study.

Journal Article↗