Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Data Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Wavelet compression of low-dose chest CT data: effect on lung nodule detection.

PURPOSE: To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS: One hundred sets of lung CT data ("cases") were compressed to 30:1, 20:1, and 10:1 levels by using a wavelet-based JPEG2000 method, resulting in 400 test cases. Each case consisted of nine 1.25-mm sections that had been obtained with 20-40 mAs. Four thoracic radiologists independently interpreted the test case images. Performance was measured by using area under the receiver operating characteristic (ROC) curve (Az) and conventional sensitivity and specificity analyses. RESULTS: There were 51 cases with and 49 without lung nodules. Az values were 0.984, 0.988, 0.972, 0.921, respectively, for original and 10:1, 20:1, and 30:1 compressed images. Az values decreased significantly at 30:1 (P =.014) but not at 10:1 compression, with a trend toward significant decrease at 20:1 (P =.051). Specificity values were unaffected by compression (>98.0% at all compression levels). Sensitivity values were 86.3% (176 of 204 test cases with nodules), 77.9% (159 of 204 cases), 76.5% (156 of 204 cases), and 70.1% (143 of 204 cases), respectively, for original and 10:1, 20:1, and 30:1 compressed images. Results of logistic regression model analysis confirmed the significant effects of compression rate and nodule attenuation, size, and location on sensitivity (P <.05). CONCLUSION: While no reduction in nodule detection at 10:1 compression levels was demonstrated by using ROC analysis, a significant decrease in sensitivity was identified. Further investigation is needed before widespread use of image compression technology in low-dose chest CT can be recommended.

Humans↗

The pathogenesis of spinal epidural abscess: microangiographic studies in an experimental model.

An experimental model of spinal epidural abscess was developed in rabbits by injecting Staphylococcus aureus into the posterior thoracolumbar epidural space. This model has been shown to reproduce the neurological, bacteriological, and radiological aspects of the human disease. In this study, the effect of the infectious epidural mass on the vasculature of the spinal cord in paraplegic rabbits was studied using microangiographic techniques. The normal vascular anatomy of the rabbit spinal cord was defined in control experiments. Vascular proliferation was demonstrated in the epidural space surrounding the abscesses. Anterior and paired posterior spinal arteries remained patent in paraplegic rabbits with mild or moderate spinal cord compression and in some cases of severe compression. In animals with severe compression, the anterior epidural venous plexus remained patent, but the dorsal spinal vein was occluded. Occlusion of perforating arteries occurred only with extreme spinal cord compression. These data indicate that the initial neurological deficit associated with experimental spinal epidural abscess is not due to vascular thrombosis.

Abscess↗

Wavelet compression on detection of brain lesions with magnetic resonance imaging.

The purpose of this report is to assess clinically acceptable compression ratios on the detection of brain lesions at magnetic resonance imaging (MRI). Four consecutive T2-weighted and the corresponding T1-weighted images obtained in 20 patients were studied for 109 anatomic sites including 50 with lesions and 59 without lesions. The images were obtained on a 1.5-T MR unit with a pixel size of 0.9 to 1.2 x 0.47 mm and a section thickness of 5 mm. The image data were compressed by wavelet-based algorithm at ratios of 20:1, 40:1, and 60:1. Three radiologists reviewed these images on an interactive workstation and rated the presence or absence of a lesion with a 50 point scale for each anatomic site. The authors also evaluated the influence of pixel size on the quality of image compression. At receiver operating characteristic (ROC) analysis, no statistically significant difference was detected at a compression ratio of 20:1. A significant difference was observed with 40:1 compressed images for one reader (P = .023), and with 60:1 for all readers (P = .001 to .012). A root mean squared error (RMSE) was higher in 0.94- x 0.94-mm pixel size images than in 0.94- x 0.47-mm pixel size images at any compression ratio, indicating compression tolerance is lower for the larger pixel size images. The RMSE, subjective image quality, and error images of 10:1 compressed 0.94- x 0.94-mm pixel size images were comparable with those of 20:1 compressed 0.94- x 0.47-mm pixel size images. Wavelet compression can be acceptable clinically at ratios as high as 20:1 for brain MR images when a pixel size at image acquisition is around 1.0 x 0.5 mm, and as high as 10:1 for those with a pixel size around 1.0 x 1.0 mm.

Algorithms↗

Evaluation of irreversible JPEG compression for a clinical ultrasound practice.

A prior ultrasound study indicated that images with low to moderate levels of JPEG and wavelet compression were acceptable for diagnostic purposes. The purpose of this study is to validate this prior finding using the Joint Photographic Experts Group (JPEG) baseline compression algorithm, at a compression ratio of approximately 10:1, on a sufficiently large number of grayscale and color ultrasound images to attain a statistically significant result. The practical goal of this study is to determine if it is feasible for radiologists to use irreversibly compressed images as an integral part of the day to day ultrasound practice (ie, perform primary diagnosis with, and store irreversibly compressed images in the ultrasound PACS archive). In this study, 5 Radiologists were asked to review 300 grayscale and color static ultrasound images selected from 4 major anatomic groups. Each image was compressed and decompressed using the JPEG baseline compression algorithm at a fixed quality factor resulting in an average compression ratio of approximately 9:1. The images were presented in pairs (original and compressed) in a blinded fashion on a PACS workstation in the ultrasound reading areas, and radiologists were asked to pick which image they preferred in terms of diagnostic utility and their degree of certainty (on a scale from 1 to 4). Of the 1499 total readings, 50.17% (95% confidence intervals at 47.6%, and 52.7%) indicated a preference for the original image in the pair, and 49.83% (95% confidence intervals at 47.3%, and 52.0%) indicated a preference for the compressed image. These findings led the authors to conclude that static color and gray-scale ultrasound images compressed with JPEG at approximately 9:1 are statistically indistinguishable from the originals for primary diagnostic purposes. Based on the authors laboratory experience with compression and the results of this and other prior studies, JPEG compression is now being applied to all ultrasound images in the authors' radiology practice before reading. No image quality-related issues have been encountered after 12 months of operation (approximately 48000 examinations).

Algorithms↗

FFC: a scalable FASTA compressor.

SUMMARY: FASTA is a widely used text-based format for storing nucleotide and protein sequences. The existing FASTA compressors usually focus on (slightly) improving the compression ratio, not on practical performance. We present FFC, a scalable FASTA compressor that achieves average compression speeds 4.7&#xd7; and 11.4&#xd7; higher than two high-performance compressors, zstd and NAF, respectively, across a benchmark set of seven single genomes. It also delivers average decompression speeds 3.5&#xd7; and 2.7&#xd7; higher than zstd and NAF, respectively. Although a chunk-based zstd variant with parallel decompression, pzstd, almost matches FFC speed, its compression ratio is on average by 23% worse than FFC's. For the experiment, a 14-core workstation and a RAM disk (to reduce the impact of I/O) were used. AVAILABILITY AND IMPLEMENTATION: FFC is freely available at github.com/kowallus/ffc and also as a Zenodo repository at 10.5281/zenodo.18892353, and the used datasets at 10.5281/zenodo.18873744.

Data Compression↗

Efficient storage of urodynamic signals by computer: application of FAN adaptive sampling.

Digital storage of urodynamic signals such as detrusor pressure and flowrate at a sufficiently high sampling rate (10 samples per second) to allow subsequent analysis requires considerable computer memory. A procedure for compressing these data by deleting redundant samples (the fan method of adaptive sampling) was tested. The method allows a flexible adaptation to specific hardware and a compromise between storage requirements and accuracy. In this study the number of samples required for adequate reconstruction of the detrusor pressure signal could be varied from 80% to 4% of the original number of samples by varying the average difference between reconstructed and original signal from 0.01 to 2 cm H2O. Fast components of the measurements (for example cough peaks) which were lost if a lower sampling rate or averaging was used to obtain equally low storage requirements were unaffected by this compression technique.

Algorithms↗

Performance of Web-based image distribution: client-oriented measurements.

The aim of this study was to define a clinically suitable personal computer (PC) configuration for Web-based image distribution and to assess the influence of different hard- and software configurations on the performance. Through specially developed software the time-to-display (TTD) for various PC configurations was measured. Different processor speeds, random access memory (RAM), screen resolutions, graphic adapters, network speeds, operating systems and examination types (computed radiography, CT, MRI) were evaluated, providing more than half a million measurements. Processor speed was the most relevant factor for the TTD; doubling the speed halved the TTD. Under processor speeds of 350 MHz, TTD mostly remained above 5 s for 1 CR or 16 CT images. Here Windows NT with lossy compression were superior. Processor speeds of 350 MHz and over delivered TTD <5 s. In this case Windows 2000 and lossless compression were preferable. Screen resolutions above 1280 x 1024 pixels increased the TTD mainly for CR images. The RAM amount, network speed and graphic adapter did not have a significant influence. The minimum threshold for clinical routine is any standard off-the-shelf PC better than Pentium II 350 MHz, 128 MB RAM; hence, high-end PC hardware is not required.

Computers↗

Influence of different sources on the processing and biopharmaceutical properties of high-dose ibuprofen formulations.

It is known that depending on the manufacturing and synthetic processes, drugs may exist as different forms. As a result, physicochemical properties, compression characteristics, intrinsic dissolution and bioavailability may vary substantially. The purpose of this study was to investigate the effect of different sources of ibuprofen on the processing of tablets and on their properties. Another emphasis of this work was to rationalize one or several key characteristics of the raw material as directly related to wet granulation parameters and to the behavior of final tablets. Commercially available ibuprofen was obtained from different manufacturers and a preformulation program, including X-ray crystallography, differential scanning calorimetry, scanning electron microscopy, determination of particle size distribution and flowability, was performed to characterize the raw material. Granules were prepared with a planetary mixer and liquid requirements for the end point were obtained by monitoring power consumption. Tablets were manufactured on Stokes rotary and single punch instrumented presses. Data acquisition interfaces produced compression data for each formulation. Granules and final tablets were analyzed for hardness, dissolution profiles and content uniformity. Statistical evaluations using analysis of variance and multiple comparison procedures were performed on the results to determine the significance of the variability between independent parameters. The ibuprofen tested was found to be a unique polymorphic form with some differences in the external crystallinity. The particle size characteristics of the material also allowed a differentiation between sources and although there was no differences in dissolution patterns or content uniformity, particle size was found to account for 50% of the variability in tablet hardness. Two sources of ibuprofen with lower mean particle size showed significant variations in end point liquid requirements resulting in variable tablet crushing strength.

Biopharmaceutics↗

Properties of encapsulated and hand-mixed zinc phosphate dental cement.

PURPOSE: Dental cements can be supplied as loose powder and liquid or as encapsulated syringes. This study assessed the compressive strength of a recently marketed zinc phosphate encapsulated cement compared with a hand-mixed system according to the American Dental Association Specification. MATERIALS AND METHODS: The mean fracture strength, standard deviations and associated Weibull Moduli (m) of the encapsulated and hand-mixed cements were determined by compressive fracturing 30 cylindrical specimens (height 6.0 +/- 0.1 mm, diameter 4.0 +/- 0.1 mm). Scanning electron microscopy was employed to assess crack growth from indentations and cement morphology. Image analysis was used to investigate the influence of mixing regime on pore distribution within the cement samples. RESULTS: The compressive strength data showed variation in magnitude and reliability ranging from 42 +/- 8 MPa (m = 5.2 +/- 1.0) for the encapsulated cement filled directly from the capsule to 71 +/- 11 MPa (m = 6.3 +/- 1.3) for the hand-mixed cement. The encapsulated cement matrix was extensively porous, consisting of pores between 0.1-0.5 microm diameter, compared with the non-porous hand-mixed cement matrix. Larger pores (over 18 microm diameter) were related to air entrapment in the encapsulated cement on mixing while small pores (0.1-0.5 microm diameter) were indicative of vaporization porosity commonly seen with exothermic reactions.

Air↗

Metastatic epidural spinal cord compression.

OBJECTIVES: To provide an overview on the presentation, diagnosis, and treatment of metastatic epidural spinal cord compression (MESCC). DATA SOURCES: Published articles, book chapters, and research reports. CONCLUSIONS: MESCC is a common oncologic emergency that requires prompt recognition and emergency treatment to relieve pain and preserve neurologic function. The signs and symptoms of MESCC are easily detected and can be integral assessment components of the nursing care of any patient with a solid tumor. IMPLICATIONS FOR NURSING PRACTICE: Nurses can have a dramatic impact on preventing neurologic complications caused by this oncologic metastatic problem. When neurologic compromise is not prevented or reversed, nurses also can provide expert care to patients and families in the rehabilitation phase of MESCC.

Aged↗

A chaos-based model for low complexity predictive coding scheme for compression and transmission of electroencephalogram data.

A method for low complexity, low bit rate transmission of EEG (electroencephalogram) data, based on chaotic principles, is presented. The EEG data is assumed to be generated by a non-linear dynamical system of E dimensions. The E dynamical variables are reconstructed from the one-dimensional time series by the process of time-delay embedding. A model of the form X[n + 1] = F(X[n], X[n - 1], ... , X[n - p]) is fitted for the data in the E-dimensional space and this model is used as predictor in the predictive coding scheme for transmission. This model is able to give a reduction of nearly 50% of the dynamic range of the error signal to be transmitted, with a reduced complexity, when compared to the conventionally used linear prediction method. This implies that a reduced bit rate of transmission with a reduced complexity can be obtained. The effects of variation of model parameters on the complexity and bit rate are discussed.

Adult↗

Simulation of disaster recovery of a picture archiving and communications system using off-site hierarchal storage management.

The purpose of this communication is to report on the testing of the disaster recovery capability of our hierarchical storage management (HSM) system. Disaster recovery implementation is a requirement of every mission-critical information technology project. Picture archiving and communications systems (PACS) certainly falls into this category, even though the counterpart, conventional film archive, has no protection against fire, for example. We have implemented a method for hierarchical storage with wavelet technology that maximizes on-site case storage (using lossy compression), retains bit-preserved image data for legal purposes, provides an off-site backup (lossless bit-preserving wavelet transform), and provides for disaster recovery. Recovery from a natural (earthquake and subsequent fire) or technical (system crash and data loss) disaster was simulated by attempting to restore from the off-site image and database backup to clean core PACS components. The only existing loaded software was the operating system. The database application was reloaded locally, and then the database contents and image store were loaded from the off-site component of the HSM system. The following measurements were analyzed: (1) the ability to recover all data; (2) the integrity of the recovered database and image data; (3) the time to recover the database relative to the number of studies and age of the archive, as well as bandwidth between the local and remote site; and (4) the time to recover image data relative to compression ratio, number of studies, number of images, and time depth of the archive. This HSM system, which maximizes on-site storage, maintains a legal record, and provides off-site backup, also facilitates disaster recovery for a PACS.

Computer Storage Devices↗

Wavelet compression and segmentation of digital mammograms.

An initial evaluation of Haar wavelets is presented in this study for the compression of mammographic images. Fifteen mammograms with 105 microns/pixel resolution and varying dynamic range (10 and 12 bits per pixel) containing clustered microcalcifications were compressed with two different rates. The quality and content of the compressed reconstructed images was evaluated by an expert mammographer. The visualization of the cluster was on the average good but degraded with increasing compression because of the discontinuities introduced by these types of wavelets as the compression rate increases. However, the artifacts in the decoded images were seen as totally artificial and were not misinterpreted by the radiologist as calcifications. The classification of the parenchymal densities did not change significantly but the morphology of the calcifications was increasingly distorted as the compression rate increased leading to lower estimates of the suspiciousness of the cluster and higher uncertainties in the diagnosis. The uncompressed and two sets of compressed images were also processed by a wavelet method to extract the calcifications. Despite the fact that the segmentation algorithm generated several false-positive signals in highly compressed images, all true clusters were successfully segmented indicating that the compression process preserved the features of interest. Our preliminary results indicated that wavelets could be used to achieve high compression rates of mammographic images without losing small details such as microcalcification clusters as well as detect the calcifications from either the uncompressed or compressed reconstructed data. Further research and application of multiresolution analysis to digital mammography is continuing.

Algorithms↗

Infection after open reduction and internal fixation with dynamic compression plates--clinical and experimental data.

Infection rates for open reduction and internal fixation (ORIF) with the DCP in clinical studies are based on heterogeneous data on general risk factors and do not take into account the direct effect of the implant (material, design, surface, technique). The initial degree of bacterial contamination is generally unknown and the applied definition of the term infection is not mentioned. In our own prospective randomized clinical study including 281 cases of ORIF with the DCP (154 steel vs 127 titanium), the influence of the implant material on susceptibility to local infection was examined in relation to initial bacteria contamination (109 non-contaminated / 172 contaminated). Although in the group of contaminated DCPs the difference in the infection rates for stainless steel (sSt) and commercially pure titanium (cpTi) showed no statistical significance, a tendency was apparent. In an animal experiment, the lower rates of infection for c.p.Ti-DCP compared to sSt-DCP in the presence of a local bacterial challenge could be demonstrated with statistical significance. The need for further experimental research in the field of implant related local infection after ORIF will be discussed and strategies for further investigations proposed.

Animals↗

Evaluation of polymeric materials for maxillofacial prosthetics.

The methods for initial evaluation of a new prospective maxillofacial prosthetic material, MDX-4-4210, have been described and tensile and compressive test data have been obtained. Evaluation of the data indicates that this is a promising material with significant potential for use in maxillofacial prosthetics. Further studies of the material's biologic implant compatibility, its chemical and environmental stabilities, and its clinical performance are being done.

Elasticity↗

Aortic diameter and pressure-flow sequence identify mechanism of blood flow during external chest compression in dogs.

Aortic flow and pressure relations and aortic diameter were examined during sinus rhythm, internal cardiac massage, vest cardiopulmonary resuscitation, conventional manual cardiopulmonary resuscitation and high impulse manual cardiopulmonary resuscitation in 14 anesthetized large dogs. During sinus rhythm and during internal cardiac massage, ascending aortic flow and pressure increased simultaneously and the rise in ascending aorta pressure preceded the rise in descending aortic pressure by (mean +/- SEM) 28 +/- 4 and 30 +/- 1 ms, respectively. In contrast, during vest, conventional and high impulse cardiopulmonary resuscitation, ascending aortic flow lagged behind the initial rise in aortic pressure by 40 +/- 4 to 46 +/- 4 ms and ascending and descending aortic pressure increased simultaneously (p less than 0.001 for each external compression mode versus sinus rhythm and internal massage). The ratio of pulse pressure to stroke volume increased by an order of magnitude during all modes of external chest compression (p less than 0.001 versus sinus rhythm and internal massage) and aortic diameter decreased during vest and high impulse cardiopulmonary resuscitation (p less than 0.05 versus sinus rhythm and internal massage). The hemodynamics of external chest compression depart from the normal physiologic sequence of stroke volume-induced increase in aortic pressure and diameter. The rise in aortic pressure precedes flow into the aorta, stroke volume does not fully account for pulse pressure, and aortic diameter decreases during chest compression. These data support the hypothesis that blood flow is due to fluctuations in intrathoracic pressure for high impulse as well as vest and conventional cardiopulmonary resuscitation.

Animals↗

Non-blood contacting biventricular support for severe heart failure.

BACKGROUND: Direct mechanical ventricular actuation (DMVA) is a non-blood contacting method of biventricular support. DMVA employs a vacuum attached, pneumatically regulated, flexible membrane to transfer both systolic and diastolic forces to the ventricular myocardium. The purpose of this study was to determine if DMVA effectively restores pump performance when applied to the severely failing heart. METHODS: Bovines (n = 10) underwent thoracotomy and were instrumented for continuous hemodynamic monitoring. Cardiac failure was induced by beta1-blockade to achieve a cardiac index of < 1.5 l/min/m2 for 1 hour. Heart rate was maintained at 100 bpm by atrioventricular sequential pacing. Synchronous DMVA support was then applied for 3 hours. RESULTS: Eight animals achieved significant reductions in cardiac index and mean arterial pressures (35%* and 43%* control, respectively; *p < 0.05). DMVA restored cardiac index to baseline and significantly increased arterial pressures (p < 0.05; DMVA versus cardiac failure). Pulmonary flow and mean pulmonary artery pressures were similar to baseline during DMVA (p = NS). Pathologic exam did not demonstrate evidence of significant device trauma. CONCLUSIONS: DMVA support can effectively restore pump performance of the acutely failing heart. Synchronization may be inherent to the stimulus of cardiac compression. These data further substantiate DMVA's potential as an adjunct to the field of circulatory support.

Animals↗

Confined and unconfined stress relaxation of cartilage: appropriateness of a transversely isotropic analysis.

Previous studies have shown that stress relaxation behavior of calf ulnar growth plate and chondroepiphysis cartilage can be described by a linear transverse isotropic biphasic model. The model provides a good fit to the observed unconfined compression transients when the out-of-plane Poisson's ratio is set to zero. This assumption is based on the observation that the equilibrium stress in the axial direction (deltaz) is the same in confined and unconfined compression, which implies that the radial stress deltar = 0 in confined compression. In our study, we further investigated the ability of the transversely isotropic model to describe confined and unconfined stress relaxation behavior of calf cartilage. A series of confined and unconfined stress relaxation tests were performed on calf articular cartilage (4.5 mm diameter, approximately 3.3 mm height) in a displacement-controlled compression apparatus capable of measuring delta(z) and delta(r). In equilibrium, delta(r) > 0 and delta(z) in confined compression was greater than in unconfined compression. Transient data at each strain were fitted by the linear transversely isotropic biphasic model and the material parameters were estimated. Although the model could provide good fits to the unconfined transients, the estimated parameters overpredicted the measured delta(r). Conversely, if the model was constrained to match equilibrium delta(r), the fits were poor. These findings suggest that the linear transversely isotropic biphasic model could not simultaneously describe the observed stress relaxation and equilibrium behavior of calf cartilage.

Animals↗