[CT-free image guided acetabulum navigation in clinical routine].

After experimental and preclinical evaluation (HAP Paul Award 2001) of the CT-free image-guided surgical navigation system for acetabular cup placement (SurgiGATE C-arm cup" by Medivision, Switzerland), the system was introduced into clinical routine. The computation of the angular orientation of the cup is based on reference coordinates from the anterior pelvic plane concept. A hybrid strategy for pelvic landmark acquisition has been introduced involving percutaneous pointer-based digitization with the noninvasive biplanar landmark reconstruction using multiple registered fluoroscopy images. From January 2001 to December 2002, a total of 256 consecutive patients with primary osteoarthrosis (mean age 69 years, 161 male, 95 female, 132 left, and 124 right hip joints) were operated on with the hybrid CT-free navigation system. During each operation the angular orientation of the inserted implant was recorded. To determine the placement accuracy of the acetabular components, 50 consecutive patients underwent a CT scan 7-10 days postoperatively to analyze the cup position related to the anterior pelvic plane. This was all done blinded by the same investigator with the planning software of the CT-based navigation system of Medivision. There was no significant learning curve observed for the use of the system. The mean value for postoperative inclination was 43 degrees (SD 3.0, range: 37 degrees -49 degrees ) and for anteversion 19 degrees (SD 3.9, range: 10 degrees -28 degrees ). The resulting system accuracy, i.e., the difference between intraoperatively calculated cup orientation and postoperatively measured implant position showed a mean error of 1.5 degrees for the inclination (maximum 5 degrees, SD 1.1) and 2.4 degrees for the anteversion (maximum 6 degrees, SD 1.3). An accuracy of better than 5 degrees inclination and 6 degrees anteversion was achieved under clinical conditions, which implies that there is no significant difference in performance from the established CT-based navigation methods. Image-guided CT-free cup navigation provides a reliable solution for future THA.

Acetabulum↗

[Preparation and technique for surgical treatment of 225 acetabulum fractures. 2 year results of 175 cases].

Between December 1986 and November 1995, 222 patients with 225 acetabular fractures were treated operatively by three surgeons in the Department of Traumatology and Emergency Surgery of the University Hospitals of the Catholic University of Leuven. Indications for surgery were unstable fracture, displaced fracture through the acetabular dome and fracture with intra-acetabular fracture fragments. There were 37.3% A-fractures, 49.7% B-fractures, and 13% C fractures according to the AO Classification. In 16.4% of fractures there were primary neurological deficits. Patients were treated operatively after an average of 5.0 days. The Kocher-Langenbeck approach was used in 56.9% of cases, the ilio-inguinal approach in 27.1% and the extended iliofemoral approach in 4%. In 7.1% of patients, a primary total hip endoprosthesis was implanted. There was no intra- oder perioperative mortality. The average hospital stay was 26.1 days. In 7.1% of patients, we noted secondary neurological problems. Deep infections were present in 1.3%. In 11.1% of patients a second operative procedure was necessary. We were able to review 175 patients after an average of 2 years. Signs of arthrosis and periarticular ossification were noted on the x-rays: walking distance, hip mobility and pain intensity were asked about and recorded after the clinical examination. In 76% of patients an excellent or good result on the Merle-d'Aubigne scale was obtained. T-fractures and posterior wall fractures were followed by the worst results. During this 9-year period, changes have been made to the preoperative radiological examination carried out, the choice of operative approach and our policy on prevention of thrombosis prophylaxis and postoperative ossification. After thorough preoperative diagnosis and with a meticulous operative technique, it is possible to stabilise the vast majority of acetabular fractures through the three classical approaches. Because the fractures are relatively rare, their diagnosis complex and their surgical treatment difficult, specific training is essential for every acetabular surgeon.

Acetabulum↗

[Paraproctic fistula in acetabulum loosening after implantation of a total hip endoprosthesis. A rare complication].

In this paper we present the unusual case of a fistula after implantation of a total hip prosthesis. In a 75-year old woman with a fracture of the thigh bone, we observed a paraproctic fistula 42 months after implantation of a total hip prosthesis. To our knowledge there have been no such cases reported with this complication. Thus, we wound like to demonstrate the progress of the illness, the first symptoms, and the kind and success of the treatment.

Acetabulum↗

[A new device for positioning cerclage of the acetabulum].

Open reduction with internal stabilization is considered to be the standard therapy for the treatment of displaced acetabular fractures. The internal fixation is routinely achieved by the use of plates and screws. The use of cerclage wires and cables as a reduction aid and definitive implant for stabilization has only occasionally been reported in the literature. The indication was mostly limited to use in elderly patients with insufficient bone stock. A newly instrument developed on the basis of a standard bone elevator is presented. It allows a safe, semiclosed application of a cerclage wire around the greater ischiatic notch through use of the second window of the ilioinguinal approach. A wide dissection at the "outside" of the pelvis is not necessary.

Acetabulum↗

[The value of CT in classification and decision making in acetabulum fractures. A systematic analysis].

UNLABELLED: The classification of acetabular fractures and especially the diagnosis of additional lesions can be misleading, when the personal experience is limited and the decisions are based only on conventional radiographs. The introduction of Spiral-CT with multiplanar reformations and 3-D views has improved the quality of visualization. Due to their higher costs, the need of these additional diagnostic tools is frequently questioned. This paper discusses the relevance of plain radiographs, 2-D-CTs, 3-D-CTs and Femursubtraction-CTs (FsCT) for the classification of acetabular fractures, based on a controlled study. METHODS: Thirty physicians with different levels of experience in acetabular surgery were divided in three groups of 10 each: group I comprised residents without operative experience in acetabular surgery, group II was physicians with 3-10 years of operative experience, and group III was experts in acetabular surgery. A total of 10 complete radiographic cases of high quality providing all levels of preoperative diagnostics (plain radiographs, 2-D-CT, CT with multiplanar reformation, 3-D-CT, Fs-CT) of different acetabular fracture types were prepared. The task for each candidate was to classify the fracture according to Letournel and to identify all additional injuries within the hip joint (e.g. marginal impaction, head fractures, etc.). The different diagnostic "levels" could be ordered stepwise according to personal need and no time limit was given. The case was finished when the candidate presented his final diagnosis. The use of the different radiographs, the preliminary diagnosis, the changes in diagnosis, and the final decisions were recorded. These findings were correlated with the different levels of experience and against a "consensus classification" which was generated by thorough discussion, and the use of intraoperative information and postoperative radiographs not accessible to the candidates. RESULTS: The "correct" fracture classification based on plain radiographs was: group I, 11%; group II, 32%; group III, 61%. Based on 2-D-CT a "correct" diagnosis was reached by 30% in group I, by 55% in group II, and by 76% in group III. With consideration of the "transient forms" in acetabular fractures based on Letournel and the 3-D-CT used mainly by group I, the rate of "correct" classifications rose to 65% in group I, 64% in group II and 83% in group III. The modifiers were diagnosed "correctly" in group I by 37%, in group II by 56%, and in group III by 73%. The use of the 3-D-CT and especially the Fs-CT by group I resulted in an improvement in the rate of correct classifications to 61%, whereas in group II the Fs-Ct was used only exceptionally. The 2-D-CT was the basis for the diagnosis of the additional lesions in acetabular fractures within all groups resulting in 73% complete diagnoses in group III. This study showed the importance of CT for the exact analysis and classification of acetabular fractures. In particular, the secondary reformations in CT and the 3-D-views dramatically improved the rate of "correct" classifications in the group of surgeons with limited personal experience in acetabular surgery. This allows the less experienced an acceptable level of "correct" diagnoses, so that the treatment options can be weighed correctly. Among the "experts" a rate of divergent classifications of approximately 20% was observed, especially in "transient" forms of acetabular fractures.

Acetabulum↗

[Acetabulum fractures].

Each acetabular fracture means a huge intellectual and a demanding technical challenge for the surgeon on charge. Because the hip joint is situated within a complex three-dimensional structure the diagnostics of its lesions are difficult. Three conventional X-ray views enable the recognition of a specific fracture type, computertomographic cuts give a detailed view on the type and the severity of the cartilage lesions, threedimensional reconstructions make a clear spatial imaging of the fracture configuration possible. These different radiological images are not superfluous, but complementary. Preoperative planning involves the choice of the approach and of the type of osteosynthesis. The Kocher-Langenbeck and the ilioinguinal approach are non-extensile approaches. They enable the internal fixation of the big majority of acute lesions. Each approach has its specific, well defined field of indications. Specific complications of the Kocher-Langenbeck approach are sciatic nerve palsy and periarticular ossifications. Complications of the ilioinguinal approach are damage to the iliac vessels and/or lymph vessels, to the lateral femoral cutaneous nerve and to the femoral nerve. Aseptic necrosis of the femoral head is a common complication of both approaches, but has to be differentiated from wear of the femoral head due to friction. Indications for the extended approaches are limited, their risks and complications are higher than in the non-extensile approaches. An active aftertreatment is only possible after a stable fracture fixation, the characteristics of physiotherapy are dependent on the type of approach. In a personal series of 225 operatively treated acetabular fractures, 128 were stabilized through a Kocher-Langenbeck approach. 103 of these patients could be reviewed after an average time of 25.9 months. 73.8% of them had an excellent or good result in the classification of Merle d'Aubigne. 61 fractures were fixed through an ilioinguinal approach. 48 could be reviewed after a mean time of 23 months. 85.4% obtained an excellent or good result in the functional scale of Merle d'Aubigne. These results are comparable with similar larger studies in the recent literature. The acetabular fracture in the elderly is a specific and rare type of lesion. When operated on quickly, open reduction and internal fixation can also give gratifying results. Alternative methods as primary or secondary total hip arthroplasty are at least as demanding for the patient and are combined with a high percentage of loosening of the acetabular component. The rarity and complexity of acetabular fractures asks for a specific teaching and learning with a experienced acetabular surgeon.

Acetabulum↗

[Anchoring principles in hip prosthesis implantation. II: Acetabulum components].

In this review the different anchorage concepts of cemented and cementless acetabular components are presented and clinical long-term results--if available--are discussed. Despite numerous design improvements and modifications the long-term durability of acetabular components remains a major concern with results being clearly inferior than achieved with femoral components. Until valid, prospective long-term success is proven for cementless designs cemented acetabular fixation using modern cementing technique must be regarded as standard treatment. However, successful fixation over 15-20 years very much depends on the quality of operative and cementing technique. Some cementless systems appear easier to use and have been documented to offer reliable mid-term survival rates. In young patients cementless devices have been well established and for some systems promising 10-year results have been published.

Acetabulum↗

[Quality of life after acetabulum and pelvic ring fractures. Correlation of long-term results with the "Injury Severity Score" (ISS)].

Patients with acetabular (AF) and pelvic ring fractures (BrF) make heavy demands on hospital resources and face difficulties in rehabilitation. From the patients' point of view, milestones in recovery are quality of life and return to productivity. We studied 42 patients with acetabular and 64 patients with pelvic ring fractures over a period of 10 years. The average follow-up took place 4 years after discharge. The injury severity score (ISS) did not correlate to long-term disability and quality of life (QoL) based on the Rosser index, data on return to productivity, or to radiological and clinical outcome. This study emphasizes the need for new injury scoring systems that better predict the recovery and ability to return to work of trauma patients after surviving pelvic fractures. Proper follow-up evaluations should analyze the patients' quality of life and working activity beside traditional items such as radiological and clinical findings.

Acetabulum↗

[Acetabulum revision. Classifications and treatment possibilities].

Several different defect classifications have been published. The most commonly used are described. For clinical practice, differentiation between "contained" and "noncontained" or segmental defects has proven useful. If the acetabular rim provides support, press-fit cups can be used without screws. With an appropriate reaming technique, it is possible to create a sufficiently supportive bed for the implant in many cases. This allows the use of a press-fit acetabular component over a wide range of defects as long as a tilting of the cup can be avoided. Between 1988 and 1995, 439 acetabular cups were revised at the Orthopedic University Clinic in Basel, 171 of them using the Morscher press-fit cup. After a mean follow-up of 7.1 years, not a single cup had to be revised for aseptic loosening. The 9.5% dislocations were due to abductor insufficiencies because of trochanteric pathologies or muscular alterations from former approaches.

Acetabulum↗

Unusual facets on the acetabulum in dry adult human coxal bones: a morphological and radiological study.

A smooth facet was found antero-inferior to lunate surface of 48 acetabula, in a study conducted on 315 dry adult coxal bones, 26 of which (13 pairs) were of articulated pelves. Three different shapes of the facet were oval (56.3%), piriform (22.9%) and elongated (20.8%). The prevalence of the oval facet was higher in both sexes. In 37.5% bones it extended to superior ramus of pubis and in 62.5% it was limited within the acetabular margin. They were either discrete (58.3%) or continuous with the lunate surface (41.7%). The surface configuration was flat (29.2%), concave (43.7%) or grooved (27.1%). One male articulated pelvis showed a bilateral presentation. Measured along the long axis the size varied between 11 to 17 mm. The radiographs showed notching, antero-inferior to acetabular margin in grooved facets whereas concave and flat facets were seen as areas of rarefaction. It is postulated that this facet could be a consequence of a particular posture which results in traction of the ligaments attached to this area. This unusual feature has not been reported earlier.

Acetabulum↗

Three-dimensional computed tomography in the assessment of fractures of the acetabulum.

Axial CT has, for many years, been shown to be superior to conventional radiology in the demonstration and assessment of acetabular fractures. The more recent development of complex computer programmes has enabled the production of three-dimensional images (3D CT) from sets of contiguous axial scans. 3D CT permits full imaging of the pelvis with the minimum of distress to the patient and with the minimum of radiation exposure. The ability to rotate the 3D images around a variety of axes provides a valuable perceptual link between conventional radiographs and axial CT, and enables the creation of unique images that offer perspectives unobtainable by conventional radiology. The improved visualization of the pelvis leads to more accurate diagnosis of the fracture, and hence better surgical planning and management.

Acetabulum↗

A new bleeding model of the human acetabulum and a pilot comparison of 2 different cement pressurizers.

In this cadaver study, we compared 2 different acetabular cement pressurizers (Exeter and Bernoski type) in paired human acetabula with simulated intraosseous bleeding. Pressure transducers were used to record intra-acetabular pressures during pressurization. Anteroposterior radiographs of the entire specimens were taken. Subsequently, standardized 3-mm-thick sections were cut through the acetabula, which were then microradiographed to evaluate cement penetration. Adequate pressurization was obtained with either pressurizer. The peak and sustained pressures obtained with the Exeter pressurizer (peak, 80 kPa; sustained, 38 kPa) tended to be higher than the pressures obtained with the Bernoski pressurizer (73 kPa; 24 kPa; P > 0.05). Accordingly, a tendency toward improved cement penetration into cancellous bone was found using the Exeter pressurizer (P >.05).

Acetabulum↗