Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Transducers”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Suppression of HIV-1 infection in primary CD4 T cells transduced with a self-inactivating lentiviral vector encoding a membrane expressed gp41-derived fusion inhibitor.

Peptidomimetics of HIV-1 gp41 sequences required for membrane fusion are potent inhibitors of HIV-1 entry. We hypothesize that expression of a membrane-bound gp41-derived fusion inhibitor will confer HIV-1 resistance to primary CD4 T cells. Efficient gene delivery and stable expression of a membrane-bound gp41-derived fusion inhibitor to primary CD4 T cells was accomplished using a self-inactivating lentiviral vector. A potent antiviral effect was observed when transduced CD4 T cells were challenged with a highly virulent CXCR4-tropic strain of HIV-1. Production of soluble p24 in the supernatant was inhibited 100-fold, and cytopathic effects were evident early in non-transduced cells and absent in transduced cells. Expression of the gp41 sequences was not detrimental to CD4 cells as transduced CD4 T cells exhibited a population doubling time that was equivalent to T cells transduced with a control vector. Results from this study support the rationale to use this lentiviral vector targeted at HIV entry as a potential gene therapy for HIV infection.

Anti-HIV Agents↗

Efficient protection from methotrexate toxicity and selection of transduced human hematopoietic cells following gene transfer of dihydrofolate reductase mutants.

OBJECTIVE: While retrovirally mediated gene transfer of dihydrofolate reductase mutants (mutDHFR) has convincingly been demonstrated to confer methotrexate (MTX) resistance to murine hematopoietic cells, clinical application of this technology will require high efficacy in human cells. Therefore, we investigated retroviral constructs expressing various point mutants of human DHFR for their ability to confer MTX resistance to human clonogenic progenitor cells (CFU-C) and to allow for in vitro selection of transduced CFU-C. METHODS: Primary human hematopoietic cells were retrovirally transduced using MMLV- and SFFV/MESV-based vectors expressing DHFR(Ser31), DHFR(Phe22/Ser31), or DHFR(Tyr22/Gly31). MTX resistance of unselected and in vitro-selected CFU-C was determined using MTX-supplemented methylcellulose cultures and gene transfer efficiency was assesed by single-colony PCR analysis. RESULTS: While less than 1% mock-transduced CFU-C survived the presence of > or =5 x 10(-8) M MTX, MMLV- and SFFV/MESV-based vectors expressing DHFR(Ser31) significantly protected CFU-C from MTX at doses ranging from 2.5 to 30 x 10(-8) M. Vectors expressing DHFR(Phe22/Ser31) or DHFR(Tyr22/Gly31) were even more protective and MTX-resistant CFU-C were observed up to 1 x 10(-5) M MTX. Three-day suspension cultures in the presence of 10-20 x 10(-8) M MTX resulted in significant selection of mutDHFR-transduced CFU-C. The percentage of CFU-C resistant to 10 x 10(-8) M MTX increased fourfold to 20-fold and provirus-containing CFU-C increased from 27% to 79-100%. CONCLUSION: Gene transfer of DHFR using suitable retroviral backbones and DHFR mutants significantly increases MTX resistance of human CFU-C and allows efficient in vitro selection of transduced cells using a short-term selection procedure.

Cell Separation↗

Generation of peptide-specific CD8+ T cells by phytohemagglutinin-stimulated antigen-mRNA-transduced CD4+ T cells.

Functional analysis of antigen-specific CD8(+) T cells is important for understanding the immune response in various immunological disorders. To analyze CD8(+) T cell responses to a variety of antigens with no readily defined peptides available, we developed a system using CD4(+) phytohemagglutinin (PHA) blasts transduced with mRNA for antigen molecules. CD4(+) PHA blasts express MHC class I and II, and also CD80 and CD86 and are thus expected to serve as potent antigen presenting cells. EGFP mRNA could be transduced into and the protein expressed by more than 90% of either LCL or CD4(+) PHA blasts. Its expression stably persisted for more than 2 weeks after transduction. In experiments with HLA-A*2402 restricted CD8(+) CTL clones for either EBNA3A or a cancer-testis antigen, SAGE, mRNA-transduced lymphoid cells were appropriate target cells in ELISPOT assays or (51)Cr releasing assays. Finally, using CD4(+) PHA blasts transduced with mRNA of a cancer-testis antigen MAGE-A4, we successfully generated specific CTL clones that recognized a novel HLA-B*4002 restricted epitope, MAGE-A4(223-231). Messenger RNA-transduced CD4(+) PHA blasts are thus useful antigen presenting cells for analysis of CD8(+) T cell responses and induction of specific T cells for potential immunotherapy.

Animals↗

A conical piezoelectric transducer with integral sensor as a self-calibrating acoustic emission energy source.

The experimental results of a conical piezoelectric transducer with integral backing sensor as a self-calibrating simulated acoustic emission (SAE) energy source are presented. It has been shown that there is a negative linear relationship between the energy of SAE signal detected by the backing sensor and the relative strength (signal energy) of SAE source in the structure detected by a reference sensor under different transducer-to-structure coupling efficiencies, with AC drives of the same wave packet, frequency and peak amplitude to excite the conical transducer as a SAE source at all the investigated frequencies over the frequency range of interest in AE measurements (nominally from 50 kHz to around 1 MHz). This should enable the relative strength of the SAE source in a structure to be determined using the SAE measurement from the backing sensor for the selected electrical inputs to the conical transducer, and hence to remove the concerns about inconsistent transducer-to-structure coupling affecting the relative strength of the SAE source for calibration.

Journal Article↗

Ultrasonic transducers working in the air with the continuous wave within the 50-500 kHz frequency range.

Transmitting and receiving ultrasonic waves in the air requires high standards of both the transmitters and the receivers of these waves. The paper presents the results of measurements of ultrasonic signals generated by ultrasonic transducers of mean power working with the continuous wave, designed for operating in the air at the frequencies between 50 and 500 kHz. The characteristic feature of these transducers is their high effectiveness and sensitivity, which are necessary for working in the transmission system. Directional characteristics' measurements and the measurements of the acoustic field in the air enabling its visualization on different planes were done on specially built research setups. The results of the measurements of these transducers' admittance were also presented. Because of the forecast applications of these transducers for examining ultrasonic signals transmitted in the air by materials with different degrees of porosity, obtaining the high energy of the generated ultrasonic wave is necessary. This was possible thanks to applying layers of acoustic impedance Z approximately (0.2/1.0)x10(6) kg/(m2 s) matching the high impedance of ceramics with the low impedance of air. The designed and produced transducers had the normalized diameter of D=38 mm and worked at frequencies within the ranges of f=50, 200, 350 and 500 kHz.

Journal Article↗

Piezoelectric transducer design via multiobjective optimization.

The design of piezoelectric transducers is usually based on single-objective optimization only. In most practical applications of piezoelectric transducers, however, there exist multiple design objectives that often are contradictory to each other by their very nature. It is impossible to find a solution at which each objective function gets its optimal value simultaneously. Our design approach is to first find a set of Pareto-optimal solutions, which can be considered to be best compromises among multiple design objectives. Among these Pareto-optimal solutions, the designer can then select the one solution which he considers to be the best one. In this paper we investigate the optimal design of a Langevin transducer. The design problem is formulated mathematically as a constrained multiobjective optimization problem. The maximum vibration amplitude and the minimum electrical input power are considered as optimization objectives. Design variables involve continuous variables (dimensions of the transducer) and discrete variables (the number of piezoelectric rings and material types). In order to formulate the optimization problem, the behavior of piezoelectric transducers is modeled using the transfer matrix method based on analytical models. Multiobjective evolutionary algorithms are applied in the optimization process and a set of Pareto-optimal designs is calculated. The optimized results are analyzed and the preferred design is determined.

Journal Article↗

An ultrasonic measurement model using a multi-Gaussian beam model for a rectangular transducer.

To date, ultrasonic measurement models have primarily treated systems where circular transducers are used. Recently, however, a highly efficient ultrasonic beam model for a rectangular transducer has also become available where the transducer is represented as a superposition of a relatively few Gaussian beams. Thus, using the multi-Gaussian beams, we developed ultrasonic measurement models for systems where a rectangular transducer is employed. In this paper, we describe the developed models including the beam model, the efficiency factor for a rectangular transducer and far-field scattering models for some standard scatterers. Furthermore, the accuracy of the proposed model is verified by the comparison of the model-based predictions to the experimental measurements.

Journal Article↗

Study of 1-3-2 type piezoelectric composite transducer array.

Based on a new structure of precise location and decoupling between the transducer elements, high frequency underwater transmission transducer arrays with 4 elements and 8 elements serried uniform linear array were studied, using novel 1-3-2 type piezoelectric composite as the sensing material. There are ceramic framework supports in the transverse and longitudinal directions in 1-3-2 type piezoelectric composite structure; the transducer is free from the influence of outside mechanical impact and the environment temperature change. Transducer and array samples have been designed, fabricated and measured. The resonant frequency is 150 kHz, resonant transmission response greater than 160 dB, and bandwidth is from 140 kHz to 160 kHz. The results indicate that, the transducer array has wide bandwidth, high sensitivity, stabile performance, and good coherence.

Journal Article↗

Dendritic cells transduced with recombinant adenoviruses induce more efficient anti-tumor immunity than dendritic cells pulsed with peptide.

Transduction with recombinant, replication-defective adenovirus (AdV) vectors encoding a transgene is an efficient method for gene transfer into murine or human dendritic cells (DC). We previously reported that human dendritic cells transduced with recombinant adenovirus encoding the CEA gene (AdVCEA) can effectively induce antigen-specific cytotoxic T lymphocytes (CTL) in vitro. In this study, the efficacy of vaccination using AdVCEA-transduced DC was compared with peptide-pulsed DC in terms of the antigen-specific CTL activity and anti-tumor immunity to MC38/CEA2 in a murine tumor model. AdVCEA-transduced DC increased antigen-specific T-cell proliferation, augmented the number of IFN-gamma secreting T-cells and induced potent CEA-specific CTL capable of lysing target cells pulsed with CEA peptide, as well as MC38/CEA2 expressing CEA, compared to peptide-pulsed DC. Moreover, vaccination of mice with AdVCEA-transduced DC induced a potent protective and therapeutic anti-tumor immunity to MC38/CEA2 in a subcutaneous model. These data suggest that AdVCEA-transduced DC appears to be superior to peptide-pulsed DC for the induction of anti-tumor immunity against tumor cells; this occurs through augmentation of the antigen-specific CTL response and may be used as an efficient DC-based tumor vaccine applicable to clinical care.

Adenoviridae↗

Strategies to expand transduced hematopoietic stem cells in vivo.

Data in mice suggest that in vivo selection strategies will expand the numbers of transduced hematopoietic stem cells (HSC) to levels sufficient for clinical therapies, and it is argued that comparable strategies will benefit larger animals and humans. To test this assumption, we performed virtual gene therapy in mouse and cat, species in which the in vivo kinetics of HSC are defined. In the simulated experiments, 10% of HSC and 50% of short-term repopulating cells were transduced with a gene allowing a conditional replication or apoptosis advantage. After transplantation, differentiation proceeded stochastically and contributions of transduced cells were tracked for 2 years. Fifty independent transplantations were simulated per species for each analysis. When transduced HSC had a 2-fold increased chance of replication (self-renewal) extending for 4, 10, or 20 weeks after transplantation, or a 5-fold replication advantage extending for 4 weeks, results in mice were far better than in cat, a larger animal, with slower baseline HSC cell cycle kinetics. Similarly, when transduced HSC had a 2-, 4-, or 10-fold decreased chance of apoptosis, extending for 20 or more weeks after transplantation, the murine studies were poor predictors of feline results. Simulation may allow one to optimize and/or understand the limitations of a gene therapy strategy.

Animals↗

Probing the sensory rhodopsin II binding domain of its cognate transducer by calorimetry and electrophysiology.

Sensory rhodopsin II, a repellent phototaxis receptor from Natronobacterium pharaonis (NpSRII) forms a tight complex with its cognate transducer (NpHtrII). Light excitation of the receptor triggers conformational changes in both proteins, thereby activating the cellular two-component signalling cascade. In membranes, the two proteins form a 2:2 complex, which dissociates to a 1:1 heterodimer in micelles. Complexed to the transducer sensory rhodopsin II is no longer capable of light-driven proton pumping. In order to elucidate the dimerisation and the size of the receptor-binding domain of the transducer, isothermal titration calorimetry and electrophysiological experiments have been carried out. It is shown, that an N-terminal sequence of 114 amino acid residues is sufficient for tight binding (K(d)=240nM; DeltaH=-17.6kJmol(-1)) and for inhibiting the proton transfer. These data and results obtained from selected site-directed mutants indicate a synergistic interplay of transducer transmembrane domain (1-82) and cytoplasmic peptide (83-114) leading to an optimal and specific interaction between receptor and transducer.

Animals↗

Modeling of ultrasonic fields radiated by contact transducer in a component of irregular surface.

The wedge of a contact transducer is imperfectly coupled to a component of irregular surface. A volume between the wedge and the component (filled by water or oil used as a coupling) is created that fundamentally modifies transducer radiation behavior. As a result, phenomena like beam spreading, skewing and splitting, generation of unwanted contributions that possibly lead to false alarms may occur. At first, the paper describes a model to account for the main effects observable in such a situation. The model is based on a matrix method which describes the behavior of transient elementary contributions as the variation of a pencil propagating into homogeneous regions (namely, the wedge, the coupling and the component) and through interfaces between them (refraction and reflection). The elementary contributions accounting for the finite size of the transducer are summed to predict transducer diffraction effects. In a second part, predicted fields are compared to measured results. The comparison concerns particle velocity fields measurements at the surface opposite to that (irregular) on which the transducer acts. The very good agreement obtained proves the validity of our approach.

Journal Article↗

Finite element three-dimensional analysis of the vibrational behaviour of the Langevin-type transducer.

The vibrational behaviour of the Langevin transducer is usually analysed using 1D Mason model which is valid when the lateral dimensions of the transducer are smaller than a quarter wavelength at the fundamental longitudinal resonance. In this work a 3D finite element analysis of the Langevin transducer's behaviour operating in the underwater sonar range of frequencies (30-140 kHz) is presented. Several samples with total length greater, comparable to, and smaller than the diameter of the transducer are analysed. For each sample, the resonance frequencies in the observed frequency range are computed and compared with those obtained experimentally from the measurements carried out using several in-house built prototypes. For the most important aspect ratios the resonance displacement distributions are presented and discussed. The results obtained permit to gain insight into the coupling phenomenon between thickness-extensional and radial modes and suggest that in practical applications transducers with diameters comparable to or greater than total length of the active stack can also be used. The trade-off between the efficiency and power handling ability for different designs is also discussed.

Journal Article↗

Selecting passive and active materials for 1.3 composite power transducers.

1.3 PZT-polymer composites were fabricated using the dice and fill method with various PZT types and volume fractions. These composites were evaluated for power underwater transducer applications with an air backed and no matching layer configuration. Electrical input and acoustical output powers were monitored as a function of the drive level. Total acoustic power densities of 30 W/cm2 were obtained with a P189/epoxy piezocomposite vibrating at 350 kHz with a low duty cycle (1-5%) and with a 90% efficiency. Power densities up to 20 W/cm2 were measured with a 50% duty cycle. Evolution and destruction of the transducers were monitored versus increasing averaged power. It was observed that better efficiencies were obtained with low volume fraction configurations allowing natural acoustic impedance matching to water. It was found that hard PZT type (Navy III) are optimal compositions even for piezocomposite transducers. It is shown that, unlike a common belief, the polymer mechanical losses are comparable to those of the active ceramic justifying that 1.3 piezocomposites are suited for low-cost power applications. In fact, the main limitation induced by the polymer phase is a strong thermal breakdown when the temperature of the transducer approaches the glass transition region of the polymer. Measurements of the polymer losses as a function of the temperature were obtained confirming this point and offering interesting new alternatives for future composite power transducers.

Journal Article↗

Ultrasonic measurement of gas flow using electrostatic transducers.

Ultrasonic gas flowmeters typically use narrowband piezoelectric transducer arrangements for interrogating the flow of gas in a pipe. In this work, the suitability of broadband electrostatic transducers operating at frequencies of up to 1 MHz for ultrasonic measurement of gas flow has been investigated. The transit time method of ultrasonic gas flow measurement was adopted and experiments were carried out using a laboratory test rig capable of producing a range of gas flowrates up to 17.5 m/s. The test rig also allowed easy interchange of different prototype flowmetering sections. Times of flight of ultrasonic waves interrogating the gas flow were measured using separate send/receive electrostatic transducer arrangements. Two flowmeter configurations were considered. The first interrogated the flow at 45 degrees in contra-propagating upstream and downstream directions. The second consisted of an up-stream interrogation at 45 degrees to the gas flow and an interrogation made normal to the flow direction. k factors correlating the fluid velocity along the ultrasonic path with the mean fluid velocity in the pipe were calculated using experimental ultrasonic data and anemometer measurements. All transducer configurations were numerically modelled using the computational fluid dynamics software package FLOTRAN (ANSYS Inc.). Theoretical gas flow velocities for both transducer arrangements were subsequently compared with experimental values and found to be in excellent agreement. A flow-dependent frequency shift of the received ultrasonic signals was also observed simultaneously with the transit time measurement.

Journal Article↗

Wideband high-frequency line-focus PVDF transducer for materials characterization.

This paper presents the design, fabrication, operating characteristics and applications of a wideband, high-frequency, line-focus beam transducer we constructed using a 9 microm thick piezoelectric polyvinylidene fluoride (PVDF) film. This transducer possesses a focal length of 2.38 mm and an aperture angle of 84 degrees. The frequency spectrum of the signal measured at the focal point indicates that the transducer has a wide frequency response which extends from 10 MHz to over 100 MHz. When compensated for the frequency-dependent attenuation of the coupling medium, the operational frequency exceeds 150 MHz. The transducer can be operated in a time-resolved pulse mode or in a radio-frequency (rf) tone burst mode. An application of the transducer to determine the anisotropic elastic property of a silicon wafer is demonstrated. The phase velocities of surface acoustic waves (SAW) propagating along various directions on the (001) surface of cubic silicon are measured and compared to computed values.

Journal Article↗

Characterization of airborne transducers by optical tomography

This paper describes the application of an acousto-optic method to the measurement of airborne ultrasound. The method consists of a heterodyne interferometric probing of the pressure emitted by the transducer combined with a tomographic algorithm. The heterodyne interferometer measures the optical phase shift of the probe laser beam, proportional to the acoustic pressure integrated along the light path. A number of projections of the sound field, e.g. a set of ray integrals obtained along parallel paths, are made in moving the transducer to be tested. The main advantage of the method is its very high sensitivity in air (2 x 10(-4) Pa Hz-1/2), combined with a large bandwidth. Using the same principle as X-ray tomography the ultrasonic pressure in a plane perpendicular to the transducer axis can be reconstructed. Several ultrasonic fields emitted by wide-band home made electrostatic transducers, with operating frequencies between 200 and 700 kHz, have been measured. The sensitivities compared favorably with those of commercial airborne transducers.

Journal Article↗

Metabolism and activities of 3'-azido-2',3'-dideoxythymidine and 2',3'-didehydro-2',3'-dideoxythymidine in herpesvirus thymidine kinase transduced T-lymphocytes.

T-lymphocytes transduced with the conditionally toxic herpesvirus thymidine kinase gene (HSV-1 TK) are increasingly becoming important tools in genetic therapy approaches for treating viral infections and cancers. Therefore, the effects of different antiviral nucleoside drugs on the growth inhibition of parental and HSV-1 TK-transduced human T-lymphocyte cell lines (H9 and CEM TK-) were examined. As expected, both transduced cell lines were most sensitive to growth inhibition by ganciclovir (GCV). While the presence of HSV-1 TK did not potentiate 3'-azido-2',3'-dideoxythymidine (AZT) growth inhibition of H9 cells containing cellular TK; transduction of HSV-1 TK into the cellular TK-deficient CEM cells (CEM TK-) restored sensitivity to AZT. In both transduced cell lines, an HSV-1 TK-dependent growth inhibition with 2',3'-didehydro-2',3'-dideoxythymidine (d4T) was observed and a Km of 143 microM for d4T and HSV-1 TK was determined. Metabolic labeling analysis showed that drug metabolism correlated with the observed effects on cell growth. The effects of HIV-1 replication in the CEM TK- cell lines in the presence of AZT or d4T was evaluated. CEM TK- cells are largely resistant to AZT or d4T inhibition of HIV-1 replication, however, transduction of HSV-1 TK into the CEM TK- cells completely restored AZT and d4T inhibition of HIV-1 replication. These studies confirm the requirement for a thymidine kinase activity for the anti-HIV activities of d4T and suggest that AZT, but not d4T, could be potentially administered to patients receiving HSV-1 TK-transduced lymphocytes.

Acyclovir↗