Resistance of core materials against torsional forces on differently conditioned titanium posts.

STATEMENT OF THE PROBLEM: The separation of core materials from titanium posts, which have a low modulus of elasticity, has been identified as a problem in restorative dentistry. PURPOSE: This study evaluated the resistance to torsional forces of various core materials adapted to differently conditioned titanium posts. MATERIAL AND METHODS: Seven hundred and twenty specimens were tested consisting of: 6 core materials and 5 surface conditioning techniques for 2 kinds of opaquers with 10 specimens in each group (6 x 5 x 2 x 10=600) plus 6 core materials and 2 opaquers were tested and considered as control groups on nonconditioned titanium posts, each group containing 10 specimens (6 x 2 x 10=120). The custom-made pure titanium posts were conditioned with the following products: Silicoater Classical, Silicoater MD, Rocatec, Kevloc, and Siloc surface-conditioning systems. Subsequently, 6 core materials with different compositions (Durafill, Adaptic, Coradent, Ti-Core, Hytac Aplitip, and Photac-Fil Aplitip) were applied to titanium posts that were previously coated with 2 types of light-polymerized opaquers, either Artglass or Dentacolor. Sixty air-abraded titanium posts (250 microm, 30 seconds) were used as controls for each core material. Following thermocycling (5 degrees -55 degrees C, 30 seconds, 5,000 cycles), maximum torsional forces were determined with an electronic torque movement key. Data were statistically analyzed by 1-way analysis of variance followed by 2-way analysis of variance (P<.05). RESULTS: Significantly higher mean torsional forces were observed with respect to Siloc (20.4 Newton decimeter [dNm]), Silicoater Classical (18.6 dNm), Silicoater MD (18.2 dNm), and Rocatec (17.0 dNm) systems compared with the mean for the untreated control group (14.6 dNm) (P<.001). The Kevloc system (10.4 dNm) demonstrated no significant difference compared with the control group (P>.001). The Kevloc system in combination with the Artglass opaquer and Photac-Fil Aplitip (0.00 dNm) core material showed no resistance against torsional forces. Significant differences were observed between hybrid core materials and microfilled composite, compomer, or resin-modified glass ionomer core materials (P<.001). CONCLUSION: Within the limitations of this study, the resistance to torsional forces for the core materials on titanium posts increased with the use of chemical surface-conditioning techniques and varied in accordance with the opaquer type. Type of core material also significantly influenced the resistance after thermocycling.

Acrylonitrile↗

Comparison of inducible nitric oxide synthase gene expression and lung inflammation following intratracheal instillation of silica, coal, carbonyl iron, or titanium dioxide in rats.

The pulmonary toxicity of the respirable dusts silica, coal, carbonyl iron, and titanium dioxide on alveolar macrophage (AM) and neutrophil (PMN) inducible nitric oxide synthase (iNOS) gene expression and nitric oxide (NO) production was investigated. Rats were intratracheally instilled with 5 mg/100 g body weight of silica, coal, carbonyl iron, or titanium dioxide. The dust particles averaged less than 5 microns in diameter. Bronchoalveolar lavage was performed 24 h later. Bronchoalveolar lavage cell (BALC) differentials, iNOS gene expression and NO production by BALC (measured indirectly as NO-dependent chemiluminescence), and lavageable lung protein levels were measured. Analyzed on an equal mass basis, silica, coal, and titanium dioxide dusts increased the production of iNOS-dependent NO by AM. Silica and titanium dioxide both increased the levels of iNOS mRNA while carbonyl iron and coal did not. Each dust caused an increase in PMN, indicating an inflammatory response. Carbonyl iron and titanium dioxide decreased the numbers of AM. Levels of acellular lavageable lung protein were increased by silica, carbonyl iron, and titanium dioxide. When exposure was normalized for an equal number of particles, the pneumotoxic dusts, silica and coal, caused more inflammation and NO production than the nuisance dusts, carbonyl iron and titanium dioxide. Therefore, it appears that particle number is a more appropriate metric of exposure than mass when comparing the relative pathogenicity of dusts of different sizes. Furthermore, since the potency of these dusts (on a particle number basis) to increase iNOS gene expression reflects their inflammatory and pathogenic potential, it is proposed that NO may contribute to the early inflammatory damage observed in the lung following dust exposure.

Air Pollutants↗

Effect of fibronectin- and collagen I-coated titanium fiber mesh on proliferation and differentiation of osteogenic cells.

The objective of this study was to evaluate the effects of fibronectin and collagen I coatings on titanium fiber mesh on the proliferation and osteogenic differentiation of rat bone marrow cells. Three main treatment groups were investigated in addition to uncoated titanium fiber meshes: meshes coated with fibronectin, meshes coated with collagen I, and meshes coated first with collagen I and then subsequently with fibronectin. Rat bone marrow cells were cultured for 1, 4, 8, and 16 days in plain and coated titanium fiber meshes. In addition, a portion of each of these coating treatment groups was cultured in the presence of antibodies against fibronectin and collagen I integrins. To evaluate cellular proliferation and differentiation, constructs were examined for DNA, osteocalcin, and calcium content and alkaline phosphatase activity. There were no significant effects of the coatings on cellular proliferation as indicated by the DNA quantification analysis. When antibodies against fibronectin and collagen I integrins were used, a significant reduction (p < 0.05) in cell proliferation was observed for the uncoated titanium meshes, meshes coated with collagen, and meshes coated with collagen and fibronectin. The different coatings also did not affect the alkaline phosphatase activity of the cells seeded on the coated meshes. However, the presence of antibodies against fibronectin or collagen I integrins resulted in significantly delayed expression of alkaline phosphatase activity for uncoated titanium meshes, meshes coated with collagen, and meshes coated with collagen and fibronectin. Calcium measurements did not reveal a significant effect of fibronectin or collagen I coating on calcium deposition in the meshes. Also, no difference in calcium content was observed in the uncoated titanium meshes and meshes coated with fibronectin when antibodies against fibronectin or collagen I integrins were present. Meshes coated with both collagen I and fibronectin showed significantly higher calcium content when cultured in the presence of antibodies to collagen and fibronectin integrins. A similar phenomenon was also observed for collagen-coated meshes cultured in the presence of antibodies to fibronectin integrins. No significant differences in osteocalcin content were observed between the treatment groups. However, all groups exposed to antibodies against fibronectin integrins showed a significant decrease in osteocalcin content on day 16. These results show that a fibronectin or collagen I coating does not stimulate the differentiation of rat bone marrow cells seeded in a titanium fiber mesh.

Alkaline Phosphatase↗

Accumulation of a black material around some titanium coupling posts.

PURPOSE: To report 5 patients with a black material accumulating in the conjunctiva around the titanium peg and sleeve systems. METHODS: Retrospective small case series. The clinical features of 5 patients were reviewed. Histopathologic analysis was performed on specimens from 3 patients. Neutron activation analysis was performed on 1 sample. RESULTS: Five asymptomatic patients with black material accumulating in the conjunctiva at the conjunctival-titanium peg interface were evaluated. All patients had a hydroxyapatite-coated titanium sleeve with a titanium peg in position. Histopathologic analysis performed on specimens from 3 patients revealed a mixed inflammatory cell infiltrate with focal areas of a black, foreign-appearing material showing birefringence under polarized light that was predominantly intracytoplasmic. This black material did not respond to bleaching, and in 2 patients, it showed positive staining for iron (Perls method). The material from one patient was evaluated by neutron activation analysis and was found to contain titanium, aluminum, and vanadium. In 18 to 48 months of follow-up, the presence of the material did not appear to be associated with any problems. CONCLUSIONS: The presence of a black substance accumulating in the conjunctiva around some titanium coupling posts is uncommon and appears to be without any consequence in 18 to 48 months of follow-up. Our analysis revealed this substance to be consistent with titanium alloy (Ti-6Al-4V).

Adolescent↗

The accuracy of computed tomography-based linear measurements of human femora and titanium stem.

RATIONALE AND OBJECTIVES: The authors investigate the accuracy of computed tomography linear measurement of femora with titanium stem, and the effect of the stem on these measurements. MATERIALS AND METHODS: Two embedded cadaveric femora, one of them containing a titanium stem, and two cortical bone parallelepipeds were scanned. Thirty-six cross-sections were studied, each measured in two linear directions by the profile window technique. A half-maximum height method was used to determine the cortex-gap-titanium sizes from the computed tomography (CT) images. The accuracy of the measurements from the parallelepipeds, femora, and titanium stem taken from the CT was compared with those taken by a digital caliper of anatomical sections at the same level of the same bone. RESULTS: Computed tomography measurements of the parallelepipeds were similar to the anatomical size (mean relative error 0.04% +/- 0.63%). The mean error and mean relative error of the cadaveric femora CT with and without the stem were similar to the control parallelepipeds. Higher values of error were found for the titanium stem. CONCLUSIONS: The half-maximum height method in the profile window provides an accurate measurement of the femoral cortex and the titanium stem. The presence of the titanium stem in the medullary cavity of the femur did not interfere with the measurements of cortical dimensions.

Aged↗

Titanium plate fixation: a review of implant failures.

Titanium plates and screws have become widely used for the fixation of fractures and osteotomies. We began using them in 1992; however, several early hardware failure prompted a retrospective review of the occurrence of this complication. A 2-year time period was reviewed at two institutions with comparison of hardware failure rates using titanium and stainless steel implants. At one institution, 51 fractures or osteotomies of the long bones were fixed by the senior author using titanium implants between July 1992 and July 1994. One hundred one similar cases were treated over the same period by the same surgeon using stainless steel implants. The outcome is known for 48 of the cases performed with titanium and for 80 of the cases performed with stainless steel. There were five postoperative implant failures using titanium and one using stainless steel. Metallurgical analysis of one set of broken implants retrieved during a revision surgery showed no manufacturing defects. At the second institution, 21 titanium and 138 stainless steel platings were performed over 2 years. There were four titanium implant failures in four patients and one stainless steel implant failure. Our experience suggests that these implants should be used with care, particularly in high-demand settings such as nonunion or noncompliance, and that further research needs to be conducted to establish appropriate clinical indications for their usage.

Adolescent↗

Results with titanium ossicular reconstruction prostheses.

OBJECTIVES/HYPOTHESIS: Despite the enthusiasm of recent short-term reviews, no center in the United States has published results meeting American Academy of Otolaryngology-Head and Neck Surgery guidelines with titanium-based prostheses. The purpose of the study was threefold. The first purpose was to review results with a titanium prosthesis system in cases meeting American Academy of Otolaryngology-Head and Neck Surgery reporting guidelines. The second was to compare these results with previously published results using non-titanium-based prostheses. The third was to examine the authors' results for any evidence of a "learning curve." STUDY DESIGN: Retrospective chart review was performed for the period from February 2000 to August 2001 and for the period from July 2002 to February 2003. METHODS: Of 313 cases, 130 consecutive cases were identified in the first period and 65 in the second time period. One hundred two patients had adequate follow-up for published guidelines. All cases were performed by the senior author (c.g.j.). Comparison data were obtained from a previous publication involving the senior author. RESULTS: Successful rehabilitation (<or=20 dB pure-tone average air-bone gap) of conductive hearing loss was obtained in 70% of partial ossicular chain reconstructions and 44% of total ossicular chain reconstructions when titanium prostheses were used. Comparison data revealed successful rehabilitation in 48% and 21% of non-titanium-based partial and total reconstructions, respectively. Postoperative pure-tone average air-bone gaps were not significantly different when compared with results in the period from July 2002 to February 2003. CONCLUSION: Newer titanium-based ossicular reconstruction devices represent an improvement over previously used non-titanium-based prostheses. The authors think that this improvement is realized rapidly because no learning curve existed in their data.

Bone Conduction↗

Detection of titanium in human tissues after craniofacial surgery.

Generally, titanium fixation plates are not removed after osteosynthesis, because they have high biocompatability and high corrosion resistance characteristics. Experiments with laboratory animals, and limited studies of analyses of human tissues, have reported evidence of titanium release into local and distant tissues. This study summarizes our results of the analysis of soft tissues for titanium in four patients with titanium microfixation plates. Energy dispersive x-ray analysis, scanning electron microscopy, and electrothermal atomic absorption spectrophotometry were used to detect trace amounts of titanium in surrounding soft tissues. A single metal inclusion was detected by scanning electron microscopy and energy dispersive x-ray analysis in one patient, whereas, electrothermal atomic absorption spectrophotometry analyses revealed titanium present in three of four specimens in levels ranging from 7.92 to 31.8 micrograms/gm of dry tissue. Results from this study revealed trace amounts of titanium in tissues surrounding craniofacial plates. At the atomic level, electrothermal atomic absorption spectrophotometry appears to be a sensitive tool to quantitatively detect ultra-trace amounts of metal in human tissue.

Biocompatible Materials↗

Metal debris from titanium spinal implants.

STUDY DESIGN: A prospective study of tissue surrounding spinal instrumentation was performed using histologic and chemical analysis. OBJECTIVES: To identify and quantify the amount of metal debris generated by titanium pedicle screw instrumentation and to evaluate the histologic response in the spinal tissues. SUMMARY OF BACKGROUND DATA: Microscopic metal particles from the soft tissue surrounding joint arthroplasties have been shown to activate a macrophage response that leads to bone resorption and increased inflammation. The use of titanium spinal implants for spine surgery projects the possibility of generating wear debris in the spine. METHODS: Nine patients with titanium instrumentation from a prior lumbar decompression and fusion procedure who were undergoing reoperation were entered into this study. Tissue samples were collected from areas near the pedicle screw-rod junction, the scar tissue overlying the dura, and the pedicle screw holes. Metal levels for titanium were determined by electrothermal atomic absorption spectroscopy, and histologic analysis was performed by light and electron microscopy. RESULTS: Tissue concentrations of titanium were highest in patients with a pseudarthrosis (30.36 micrograms/g of dry tissue). Patients with a solid fusion had low concentrations of titanium (0.586 microgram/g of dry tissue). Standard light microscopy identified metal particles in the soft tissues. Transmission electron microscopy demonstrated macrophages with numerous secondary lysosomes containing electron-dense bodies and collagenous stroma with electron-dense rod-like profiles consistent with metal debris. CONCLUSIONS: Wear debris is generated by the use of titanium spinal instrumentation in patients with a pseudarthrosis. These particles activate a macrophage cellular response in the spinal tissues similar to that seen in surrounding joint prostheses. Patients with a solid spinal fusion have negligible levels of particulate matter.

Biocompatible Materials↗

Role of surface roughness of titanium versus hydroxyapatite on human bone marrow cells response.

This study was designed to assess human bone marrow cell response and particularly cell adhesion, proliferation, and differentiation, when cultured in vitro on titanium alloy and hydroxyapatite with different values of surface roughness. A further aim was to compare the cell response on the two materials, currently used in spinal surgery. Cell adhesion was determined after 0.5, 2, 4, and 18 hours of incubation; proliferation after 8, 11, 14, and 16 days of culture; and differentiation was evaluated with the expression of alkaline phosphatase activity after 8 and 16 days of culture. This study showed that bone marrow cells grew faster on titanium alloy than on hydroxyapatite, although fewer cells attached to titanium, compared to those attached to hydroxyapatite. No statistically significant difference was observed as the expression of alkaline phosphatase activity on hydroxyapatite and titanium alloy of the same roughness. Cell adhesion, proliferation, and differentiation are dependent on surface roughness of the biomaterial, and all three increased as the roughness of titanium alloy increased. Conclusively, surface roughness of titanium and hydroxyapatite significantly influences bone marrow cell response, and therefore these biomaterials should be used with rough outer surface, if a significant cell response on them is desired. These advantages of titanium and hydroxyapatite theoretically seem to be of particular importance in the following situations: long fusions, lumbosacral fusion, revision surgery with poor bone bank, neuropathic scoliosis associated with few bone graft reserves, and adult patients with severe osteoporosis.

Alloys↗

A comparison of combinations of titanium and resorbable plating systems for repair of isolated zygomatic fractures in the adult: a quantitative biomechanical study.

Multiple studies have sought to determine the postreduction stability of internal fixation in zygomaticomaxillary complex (ZMC) fractures. Three-point fixation with titanium miniplates is increasingly recommended to repair these injuries. Use of bioresorbable plates has been suggested to eliminate potential postoperative hardware complications. By quantitatively comparing different combinations of titanium and resorbable plating systems, this study attempts to demonstrate which combinations will provide stable fixation of the fractured ZMC. Osteotomies were performed on 40 zygomas in 20 fresh-frozen cadaver skulls, simulating noncomminuted ZMC fractures. The control group (group 0) consisted of titanium plates at the zygomaticofrontal (ZF) suture, infraorbital rim (IOR), and zygomaticomaxillary buttress (ZMB). Group 1 consisted of titanium plates at the ZF and IOR, and a resorbable plate at the ZMB. Group 2 used a titanium plate at the ZF, and resorbable plates at the IOR and ZMB. Group 3 consisted of resorbable plates at the ZF, IOR, and ZMB. A mechanical test system was used to apply loads in the vectorial direction of the masseter. Critical forces and patterns of hardware failure were recorded. Group 0 failed at a mean force of 589 +/- 146 N (60 kg). Group 1 failed at a mean force of 507 +/- 124 N (52 kg). No statistically significant differences between groups 0 and 1 were found. The mean force required for failure in groups 2 and 3 was lower. Differences in the force required for failure between groups 2 and 3 and the control group was significant (P <0.05). Failure patterns were analyzed. The ZF plate tended to stretch predominantly in groups 1, 2, and 3, whereas it tended to break in group 0 (P = 0.005). The IOR plate demonstrated predictable screw failure in groups 2 and 3 (P = 0.007). For group 0, the ZF was the site of the majority of critical failures. For groups 2 and 3, the IOR was almost invariably the site of critical failure (P = 0.004). At the ZMB, there was no significant association between failure modes and it was rarely the site of critical failure, regardless of the method of fixation. However, the strength of fixation was proportional to the number of titanium plates used. Overall, the method of fixation significantly affected the force required for mechanical failure of ZMC fractures (P <0.0001). The presence of teeth significantly increases the force required for implant failure in ZMC fracture fixation when combinations of plates are used (P = 0.038). All combinations of titanium and resorbable plates may be sufficient to overcome the displacing forces produced by the masseter and may be used for internal fixation of isolated ZMC fractures in the adult.

Biocompatible Materials↗

Tissue response to implanted ceramic-coated titanium alloys in rats.

In order to assess the tissue compatibility of the hybrid materials for the dental implant (hydroxyapatite, titanium oxide and titanium nitride coated titanium alloys), tissue response to these materials implanted in the rat subcutaneous tissue was histologically examined. Initial inflammatory response was less evident in titanium oxide coated and non-coated titanium alloys. All materials were encapsulated by thin fibrous connective tissues. The membrane thickness of hydroxyapatite coated titanium alloy was significantly higher than that of titanium nitride coated one. These results suggest that all materials possess favourable tissue compatibility and may encourage clinical use as the dental implant.

Alloys↗

The influence of Goldbonder and pre-heat treatment on the adhesion of titanium alloy and porcelain.

The present study examines the influence of a goldbonder and pre-heat treatment of the titanium on the adhesion of porcelain. Three groups of titanium substrates were given various heat treatments, namely; none, 200 degrees and 600 degrees C, respectively before applying goldbonder. The surfaces of the titanium specimens following heat treatment were examined with an electron spectroscopy for chemical analysis (ESCA). The adhesion strength was measured by the strain energy release rate (G), which was proposed by Suansuwan N and Swain MV (Int J Prosthodont. 1999;12:547). After bonding porcelain onto titanium substrates with the aid of the goldbonder, the porcelain side of specimens was notched to the interface with a thin diamond saw. Then the samples were subject to a four-point bending test. Following fracture testing, specimens were examined with a scanning electron microscope (SEM) and SEM with energy-dispersive spectroscopic analysis (EDS). The mean G-values were 38.87, 28.64 and 16.33 J m(-2), respectively. ESCA analysis showed the composition of aluminium of the surface of 600 degrees C pre-heat treatment became richer than that of the others. SEM images of the fracture surfaces showed that for the 600 degrees C pre-heat treatment fracture occurred within the oxidation layer on the titanium. High temperature pre-heat treatment prior to bonding significantly reduces porcelain bonded to titanium with the goldbonder. The Influence of Goldbonder and Pre-heat Treatment on the Adhesion of Titanium Alloy and Porcelain.

Adhesiveness↗

Durability of resin bonds to pure titanium.

PURPOSE: This study evaluated the bond strength and bond durability of new adhesive systems to pure titanium. MATERIALS AND METHODS: Plexiglass tubes filled with composite were bonded to titanium discs. Groups of 24 samples were bonded using six different bonding systems. Subgroups of eight bonded samples were stored in an isotonic artificial saliva solution (37 degrees C) for 1, 30, or 150 days. In addition, the 30- and 150-day samples were thermal cycled for 7,500 or 37,500 cycles between 5 degrees C and 55 degrees C, respectively. After these storage conditions, all samples were debonded in tension. RESULTS: The bond strength of a conventional bisphenol-A glycidyl methacrylate composite to sandblasted titanium was significantly lower than using chemomechanical bonding systems and decreased slightly during the storage time of 150 days. The additional use of a silane on sandblasted titanium resulted in an insignificant increase in bond strength and decreased over storage time to the same level as on sandblasted-only titanium. Statistically significant higher bond strengths were achieved either with the combination of silica coating and use of a conventional bisphenol-A glycidyl methacrylate composite or with the combination of sandblasting and the use of composites modified with a phosphate monomer. In the latter systems, the bond strengths were only limited by the cohesive strength of the composite resins. A new phosphate monomer containing composite showed a tendency to lose cohesive strength over time (statistically not significant). CONCLUSIONS: Using chemomechanical bonding systems, ie, silica-coating systems or modified composites with adhesive monomers, resulted in 2 to 2.5 times increased bond strength to titanium compared with the bond strength of a conventional bisphenol-A glycidyl methacrylate composite. With chemomechanical bonding systems, the resin bond to titanium was durable over 150 days, even after being stored in water and thermal cycled.

Adhesiveness↗

Compressive and diametral tensile strength of titanium-reinforced composites.

This article determines the compressive and diametral tensile strength of two titanium-reinforced composites (Bis-GMA-based), Ti-Core and Flexi-Flow cem with titanium and compares their strengths to dentin and commercially available core materials and cements. In addition scanning electron microscope (SEM) photographs were taken of Ti-Core and Flexi-Flow cem with titanium. Compressive and tensile loading was performed on a modified universal testing apparatus. Ti-Core and Flexi-Flow cem with titanium were measured to have compressive strengths of 41,132 and 41,876 psi and tensile strengths of 5219 and 4930 psi, respectively. Statistically (ANOVA, one-way analysis of variance), these titanium-reinforced composites are stronger in compressive and tensile strength than Ketac-Silver, Fleck's zinc cement, Durelon, Ketac-Cem, and GC Miracle Mix. Both titanium-reinforced composite materials approach the compressive and diametral tensile strengths of dentin (43,100 and 6000 psi). SEMs revealed that the titanium was uniformly and homogeneously interspersed within the resin matrix of the material.

Analysis of Variance↗

Effect of titanium (III) citrate as reducing agent on growth of rumen bacteria.

We compared the growth of 10 strains of rumen bacteria in an anaerobic medium reduced with cysteine hydrochloride, dithiothreitol, or titanium (III) citrate. The redox potential of medium reduced with cysteine hydrochloride was -167.8 mV; with dithiothreitol it was -175.8 mV; and with titanium(III) citrate it was -302.4 mV at a concentration of 5 X 10(-4) M titanium and -403.9 mV at 2 X 10(-3) M titanium. Maximum growth of the strains was generally lower with dithiothreitol or titanium(III) citrate than with cysteine hydrochloride, although growth was greater than in medium lacking an added reducing agent. Strains for which cysteine was required or markedly stimulatory grew only poorly with titanium(III) citrate. No strain grew in medium with sodium citrate as the energy source. Titanium(III) citrate could be used to reduce anaerobic media for some rumen bacteria if the exclusion of a sulfur-containing reducing agent is required.

Anaerobiosis↗

Anodization: a promising nano-modification technique of titanium implants for orthopedic applications.

Anodization is a well-established surface modification technique that produces protective oxide layers on valve metals such as titanium. Many studies have used anodization to produce micro-porous titanium oxide films on implant surfaces for orthopedic applications. An additional hydrothermal treatment has also been used in conjunction with anodization to deposit hydroxyapatite on titanium surfaces; this is in contrast to using traditional plasma spray deposition techniques. Recently, the ability to create nanometer surface structures (e.g., nano-tubular) via anodization of titanium implants in fluorine solutions have intrigued investigators to fabricate nano-scale surface features that mimic the natural bone environment. This paper will present an overview of anodization techniques used to produce micro-porous titanium oxide structures and nano-tubular oxide structures, subsequent properties of these anodized titanium surfaces, and ultimately their in vitro as well as in vivo biological responses pertinent for orthopedic applications. Lastly, this review will emphasize why anodized titanium structures that have nanometer surface features enhance bone forming cell functions.

Coated Materials, Biocompatible↗

Light and transmission electron microscopy of the intact interfaces between non-submerged titanium-coated epoxy resin implants and bone or gingiva.

This experiment was aimed at studying the intact tissue/implant interface of non-submerged dental implants with a titanium surface. Epoxy-resin replicas were fabricated from 3.05 x 8 mm cylindrical titanium implants with a plasma-sprayed apical portion and a smooth coronal collar. The replicas were coated with a 90-120-nm-thick layer of pure titanium and autoclaved. The coated replicas were inserted as non-submerged endosseous implants in the edentulous premolar region of dog mandibles and allowed to heal for three months. Jaw sections containing the implants were processed for light and electron microscopic study of the intact tissue/implant interface with and without prior demineralization. Gingival connective tissue fibers were closely adapted to the titanium layer, in an orientation more or less parallel to the implant surface. There was no evidence of any fiber insertions into the surface irregularities of the smooth or rough titanium surface. Undemineralized bone was intimately adapted to the titanium surface without any intervening space. In demineralized sections, the collagen fibers of the bone matrix tended to be somewhat thinner and occasionally less densely packed in the vicinity of the implant surface. However, they extended all the way to the titanium surface, without any intervening fibril-free layer.

Alveolar Process↗