Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Tin Compounds”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Detection of sentinel nodes and micrometastases using radioisotope navigation and immunohistochemistry in patients with gastric cancer.

BACKGROUND: Patients with early gastric cancer may be treated by minimally invasive surgery. This study investigated the value of sentinel node (SN) navigation surgery, including detection of micrometastases, in patients with clinical (c) T1 and T2 gastric cancer. METHODS: The day before surgery (99m)Tc-radiolabelled tin colloid was injected submucosally near the tumour. After resecting the stomach, radioisotope uptake in all dissected lymph nodes was measured during and after surgery. Micrometastasis was detected immunohistochemically using an anticytokeratin antibody. RESULTS: SNs were identified in 99 of 104 patients. The rate of identification of SNs in patients with cT1 and cT2 tumours, excluding three technical failures, was 99 and 95 per cent respectively. Lymph node metastases and/or micrometastases were found in 28 patients (15 cT1 and 13 cT2). In the 15 patients with cT1 tumours, at least one SN contained metastasis and/or micrometastasis. For cT1 tumours, the sensitivity and accuracy of detecting SNs were both 100 per cent. Six patients with cT2 tumours had false-negative results. CONCLUSION: SN navigation surgery appears to be clinically useful only for cT1 tumours. Based on SN results, the extent of lymphadenectomy may be reduced in patients with early gastric cancer.

Adult↗

Prolonged gastric emptying half-time and gastric hypomotility after drug overdose.

A prospective study was undertaken to determine if gastric motility and emptying are altered by the ingestion of overdoses of tricyclic antidepressants, acetaminophen, opioid-acetaminophen mixtures, carbamazepine or phenytoin. Gastric scintigraphy was used to measure gastric emptying half-time and assess gastric motility in 104 patients at initial presentation and again at follow-up (n = 85). Patients were imaged for 5 hours after being given 20 MBq of 99mTc tin colloid to drink. Drug serum levels were measured on all patients at initial presentation and at follow-up. We observed markedly prolonged gastric emptying half-times and severe hypomotility at initial presentation compared with follow-up in the vast majority of patients, except for a small group of patients with phenytoin poisoning. Twelve patients had gastric emptying half-times of over 300 minutes, a further 14 had half-times of over 200 minutes and 21 others had half-times of over 120 minutes. Poisoning is associated with hypomotility and a marked delay in gastric emptying that could influence the clinical course and patient management. These abnormalities may not be due to a direct effect of the ingested drug and factors such as stress may play a role.

Acetaminophen↗

Effect of cirrhosis on accuracy of 99Tcm-tin colloid scintigraphy and ultrasound scanning in diagnosis of hepatocellular carcinoma.

The effect of cirrhosis on the accuracy of ultrasonography and scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) has not been established. We have therefore studied the findings on ultrasound and scintigraphy in four groups of patients. Fourteen had HCC and cirrhosis, 13 had HCC but no cirrhosis, 53 had cirrhosis but no HCC and 31 had evidence neither of cirrhotic nor malignant liver disease. The accuracies of a positive interpretation of HCC on ultrasound and scintigraphy in the absence of cirrhosis were 85% and 66% respectively (NS), but fell (significantly in the case of scintigraphy: p less than 0.05) to 80% and 31% respectively in the presence of cirrhosis (p less than 0.01). The poorer performance of scintigraphy in the presence of cirrhosis was a result both of its lower sensitivity (50% compared with 85%) and the greater frequency of false positives (28% vs 5%: p less than 0.001). The accuracy of a negative interpretation of HCC on scintigraphy in the absence of cirrhosis was 96% but fell to 84% in the presence of cirrhosis, whereas on ultrasound it remained the same (96%). In conclusion, we recommend ultrasound in preference to scintigraphy as a more accurate technique for the diagnosis of HCC in the presence of cirrhosis.

Carcinoma, Hepatocellular↗

Sentinel node biopsy using dye and isotope double tracers in early gastric cancer.

BACKGROUND: The results of sentinel node (SN) biopsy have been improved by the use of dye and isotope double tracers in melanoma and breast cancer. However, the usefulness of this double tracer technique has not been determined in gastric cancer. The aim of this study was to investigate the possibility of improving SN biopsy results by using double tracers in gastric cancer. METHODS: Sixty-four gastric adenocarcinoma patients preoperatively diagnosed as cT1N0, were enrolled in the study. (99m)Tc tin colloid was injected by preoperative endoscopy, and lymphoscintigraphy was performed prior to operation. After laparotomy, isosulfan blue was intraoperatively injected using an endoscope. Blue-stained or radioactive nodes were identified and defined as SNs. Gastrectomy with D2 lymphadenectomy was performed in all patients. All dissected lymph nodes were evaluated for metastasis by hematoxylin and eosin staining and immunohistochemistry. RESULTS: SN detection rates using dye, isotope, or both tracers were 95.3%, 84.4%, and 96.9%, respectively, and their corresponding sensitivities were 52.9%, 52.9%, and 70.6%. In the pT1 subset, the sensitivity of the double tracer was 87.5%; and in a subset of tumors with diameter <4.5 cm, this was also 87.5%. CONCLUSIONS: These findings confirm that SN biopsy results are improved by using double tracers in gastric cancer and suggest that SN biopsy is suitable in cases of small-sized early gastric cancer.

Adult↗

[Clinical usefulness of integrated images of the radionuclide liver angiogram to evaluate diffuse hepatic disease].

New imaging method that was integrated image of radionuclide liver angiogram was proposed. Patients were placed supine beneath gamma camera, so that the liver, spleen, heart, and lung were included in an anterior image. Integrated image was recorded for 100 s, following injection of 111-222 MBq (3-6 mCi) of 99mTc tin-colloid. 595 cases were examined, and classified into 3 groups as follows. Group I: Cases without hepatic dysfunction Group II: Cases with hepatic dysfunction Group III: Liver cirrhosis. Numbers of each group were 208 (35%), 305 (51%), and 82 (14%) respectively. Integrated images were qualitatively determined by macroscopic inspection. Comparing liver intensity and lung intensity, 3 patterns of integrated image were classified. Pattern I: Liver intensity was greater than lung intensity Pattern II: Liver intensity was equal to lung intensity Pattern III: Liver intensity was less than lung intensity Numbers of each pattern were 412 (69%), 125 (21%), and 58 (10%) respectively. Numbers of group III distributed into each pattern were 8 (10%) in pattern I, 29 (35%) in pattern II, and 45 (55%) in pattern III. The correct diagnosis of liver cirrhosis as follows. In a case of choosing pattern III as diagnostic criterion, sensitivity was 55%, and specificity was 97%. The positive predictive value was 78%, and the negative predictive value was 93%. Total accuracy was 92%. This new method seems useful in evaluating diffuse hepatic disease.

Heart↗

Sentinel lymph node biopsy with 99mTC tin-colloid in patients with gastric carcinoma.

BACKGROUND/AIMS: The sentinel lymph node (SLN) is defined as the first draining node from the primary lesion. The objective of this study was to determine the feasibility of SLN biopsy in patients with gastric cancer for assessment of lymph node status. METHODOLOGY: From November 2001 through to July 2002, SLN biopsy was performed in twenty-two consecutive patients whose preoperative imaging studies showed T2 or T1 and no lymph node metastasis. Three hours prior to each operation, 99mTc tin-colloid (2.0ml, 1.0mCi) was injected into the submucosa of gastric tumor via endoscope. After SLN biopsy had been performed using gamma probe (NEO2000 Gamma Detection System, Neoprobe CO, 1999, USA), all the patients underwent radical gastrectomy. The SLN was cut and immediately manipulated for frozen section, and processed to make paraffin block for H&E and immunohistochemistry (IHC) staining. RESULTS: On average, 1.8 (range 1-5) SLNs were identified per patient. The location of all SLNs was in the perigastric area. No skip metastases were found. SLNs were identified in 20 of the 22 patients (success rate, 90.9%). The sensitivity of the SLN status in the diagnosis of the lymph node status was 82.2% (5/6) and the specificity was 100.0% (14/14). The diagnostic accuracy according to SLN status was 95.0% (19 of 20). CONCLUSIONS: SLN biopsy using radioisotope in patients with gastric cancer was a technically feasible procedure and a minimally invasive approach in the assessment of the nodal status in each patient.

Adenocarcinoma↗

Sentinel lymph node biopsy using periareolar injection of radiocolloid for patients with neoadjuvant chemotherapy-treated breast carcinoma.

BACKGROUND: The feasibility and accuracy of sentinel lymph node (SLN) biopsy after neoadjuvant chemotherapy (NAC) for patients with breast carcinoma have been investigated primarily for the situation in which the radiocolloid imaging agent is injected peritumorally. No such study has involved periareolar injection of radiocolloid, although the usefulness of this injection technique has been demonstrated in patients with early-stage breast carcinoma who have not been treated with NAC. The objective of the current study was to determine the feasibility and accuracy of SLN biopsy using periareolar injection of radiocolloid for patients with breast carcinoma who were treated with NAC. METHODS: Forty-seven patients with AJCC Stage II or III breast carcinoma who were treated with NAC were enrolled in the study. All patients underwent SLN biopsy, which involved a combination of periareolar injection of radiocolloid (technetium 99m tin colloid) and peritumoral injection of isosulfan blue dye, followed by backup axillary lymph node dissection. SLN metastases were examined by hematoxylin and eosin staining and immunohistochemical analysis using an anticytokeratin antibody. RESULTS: An SLN was identified successfully in 44 patients (94%). Twenty-nine patients (66%) had positive SLNs. Fifteen patients had negative SLNs, and 4 patients had positive non-SLNs. Thus, the false-negative rate was 12.1% (4 of 33 patients). The false-negative rate tended to be higher, although not statistically significantly so, among patients who had clinically positive axillary lymph nodes before and/or after NAC (15.8%; 3 of 19 patients) compared with patients who had clinically negative axillary lymph nodes both before and after NAC (7.1%; 1 of 14 patients). CONCLUSIONS: SLN biopsy using periareolar injection of radiocolloid is feasible after NAC. In patients with clinically negative axillary lymph nodes both before and after NAC, SLN biopsy was capable of predicting axillary lymph node status with an accuracy comparable to the accuracy associated with SLN biopsy for patients with early-stage carcinoma who have not been treated with NAC.

Adult↗

Determination of solid- and liquid-phase gastric emptying half times in cats by use of nuclear scintigraphy.

OBJECTIVE: To use nuclear scintigraphy to establish a range of gastric emptying half times (t1/2) following a liquid or solid meal in nonsedated cats. ANIMALS: 12 clinically normal 3-year-old domestic shorthair cats. PROCEDURE: A test meal of 75 g of scrambled eggs labeled with technetium Tc 99m tin colloid was fed to 10 of the cats, and solid-phase gastric emptying t1/2 were determined by use of nuclear scintigraphy. In a separate experiment, 8 of these cats plus an additional 2 cats were fed 18 ml (n = 5) or 36 ml (n = 5) of a nutrient liquid meal labeled with technetium Tc 99m pentetate. Liquid-phase gastric emptying t1/2 then were determined by use of scintigraphy. RESULTS: Solid-phase gastric emptying t1/2 were between 210 and 769 minutes (median, 330 minutes). Median liquid-phase gastric emptying t1/2 after ingestion of 18 or 36 ml of the test meal were 67 minutes (range, 60 to 96 minutes) and 117 minutes (range, 101 to 170 minutes), respectively. The median t1/2 determined for cats receiving 18 ml of the radiolabeled liquid was significantly less than that determined for cats receiving 36 ml of the test meal. CONCLUSIONS AND CLINICAL RELEVANCE: The protocol was tolerated by nonsedated cats. Solid-phase gastric emptying t1/2 were prolonged, compared with liquid-phase t1/2, and a major factor governing the emptying rate of liquids was the volume consumed. Nuclear scintigraphy may prove useful in assessing gastric motility disorders in cats.

Animals↗

Preliminary study for sentinel lymph node identification with Tc-99m tin colloid in patients with esophageal or gastric cancer.

The purpose of this study is to determine whether a lymph node identified with high radioisotope (RI) activity is a sentinel node. We studied 26 patients with either esophageal or gastric cancer whose preoperative imaging studies showed no lymph node metastasis. Before surgery, Tc-99m tin colloid was injected via endoscopy into the submucosa. In lymph nodes dissected at surgery, RI activity was measured by a scintillation counter, and metastatic status was examined by hematoxylin-eosin staining. The number of dissected nodes was 45 +/- 15 (mean +/- SD) per patient, and the number of nodes with high RI activity was 4 +/- 1. Nodal metastasis occurred in 11 of 26 patients. In 9 of these 11 patients, metastatic foci were found in one or more nodes with high RI activity. In one of the 2 remaining patients, endoscopic clipping was applied just above the injection sites, and in the other patient, the tumor invasion was beyond the muscle layer. For further analysis, the case with clipping was excluded, and only those in which the tumor invasion was confined within the muscle layer were evaluated. Six of 18 patients in this analysis showed nodal metastasis. Each of the 6 patients had at least one node that showed high RI activity and that was positive for metastasis. We conclude that when tumor invasion remains within the muscle layer, lymph nodes with high RI activity can be regarded as sentinel nodes.

Aged↗

In vivo identification of sentinel lymph nodes for clinical stage I non-small cell lung cancer for abbreviation of mediastinal lymph node dissection.

BACKGROUND: We previously reported that an identification of sentinel lymph node (SN) with a techenetium-99m (99mTc) tin colloid by ex vivo counting, i.e. the radio-activity of dissected lymph nodes, was a reliable method of establishing the first site of nodal metastasis in non-small cell lung cancer [J. Thorac. Cardiovasc. Surg. 124(2002)486]. However, for SN navigation surgery, SN should be identified before lymph node dissection (in vivo) but not after that (ex vivo). In order to reduce mediastinal lymph node dissection for clinical stage I non-small cell lung cancer (NSCLC) by SN navigation surgery, the SN identifications for hilar lymph nodes by ex vivo counting, and for mediastinal lymph nodes by in vivo, were evaluated. METHODS: Intra-operative SN identification using 99mTc tin colloid was conducted on 104 patients with clinical stage I NSCLC who had had major lung resections with mediastinal lymph node dissections. The hilar SNs were identified by ex vivo counting (after lung resection) and the mediastinal SNs were identified by in vivo counting (before lymph node dissection). To evaluate the accuracy of mediastinal SN identification by in vivo counting, it was compared with the data by ex vivo counting. RESULTS: SNs were identified in 84 patients (81%). SNs were identified at the hilum by ex vivo counting in 78 patients (93%) and at the mediastinum by in vivo counting in 40 patients (48%). While 15 patients had lymph node metastases, i.e. N1 in six and N2 in nine, the SNs could be found to have metastases during operation in 13 of the 15 patients (87%). The in vivo counting of the mediastinum missed out the mediastinal SNs identified by ex vivo counting in four of the 84 patients (5%). CONCLUSION: If the hilar SNs identified by ex vivo counting and the mediastinal SNs identified by in vivo counting had no metastases, then mediastinal lymph node dissection could be abbreviated for patients with clinical stage I NSCLC.

Aged↗

Individualized surgery for early gastric cancer guided by sentinel node biopsy.

BACKGROUND: We have reported that lymphatic mapping using indocyanine green (ICG) solution can be a good tool for identifying sentinel nodes (SNs) in gastric cancer. The purpose of this study was to evaluate individualized operations for gastric cancer guided by SN biopsy and to explore the possibility for more limited operative procedures using SN technology. METHODS: SNs were identified by using (99m)Tc-labeled tin colloid and ICG solution in patients with clinically T1N0M0 gastric cancer. When pathologic examination by frozen section revealed metastasis in SNs, we performed a standard D2 gastrectomy. Less extensive lymphadenectomy preserving vagus and pylorus was applied when the SN biopsy was negative. Then, postoperative pathology was analyzed. RESULTS: Among the 80 enrolled patients, 7 patients with apparent node metastasis or T2-3 neoplasms and 10 patients with positive metastasis in SNs underwent D2 gastrectomy. Sixty-one patients with negative metastasis in SNs underwent a less extensive, function-preserving gastrectomy. The false-negative rate in sentinel node biopsy was 23% (3/13) for frozen section and 7% (1/14) for postoperative pathology. In 3 patients with a false-negative result, metastasis was found in lymph nodes located at the station where the tracers were distributed. Of the 7 patients in whom metastasis was detected in 2 or more SNs by frozen section, postoperative pathology revealed that 3 patients (43%) belonged to the N2 category. CONCLUSIONS: SN biopsy is a useful tool for individualizing the operative procedure for early gastric cancer. Dissecting the lymph node stations only where the tracers are distributed may be a promising procedure for patients with no metastatic SNs.

Adult↗

Lymphatic mapping and sentinel node biopsy using 99mTc tin colloid in gastric cancer.

OBJECTIVE: The aim of this study was to determine the feasibility of sentinel lymph node (SLN) biopsy in patients with gastric cancer for the assessment of regional lymph node status. SUMMARY BACKGROUND DATA: SLN is the first draining node from the primary lesion, and it is the first site of lymph node metastasis in malignancy. SLN mapping and biopsy are of great significance in the determination of the extent of lymphadenectomy, allowing patients with gastric cancer to have a better quality of life without jeopardizing survival. METHODS: The SLN biopsy was performed in 46 consecutive patients having gastric cancer with a preoperative imaging stage of T1/T2, N0, or M0. Three hours prior to each operation, Tc tin colloid (2.0 mL, 1.0 mCi) was endoscopically injected into the gastric submucosa around the primary tumor. Subsequently, serial lymphoscintigraphy was performed using a dual-head gamma camera. After the SLN biopsy had been performed using a gamma probe, all patients underwent radical gastrectomy (D2 or D2+alpha). The SLN was cut and immediately frozen-sectioned. A paraffin block was then produced for permanent hematoxylin-eosin staining and immunohistochemistry (IHC). RESULTS: SLNs were successfully identified in 43 of 46 patients (success rate, 93.5%). On average, 2 (range, 1-8) SLNs were identified per patient. The positive predictive value, negative predictive value, sensitivity, and specificity of SLN biopsy were 100% (11 of 11), 93.8% (30 of 32), 84.6% (11 of 13), and 100% (30 of 30), respectively. SLNs were located at the level I lymph nodes in 38 (88.4%), the level I+II nodes in 2 (4.7%), and the level II nodes in 3 (7.0%). No micrometastases of SLNs was found on IHC for cytokeratin. CONCLUSIONS: SLN biopsy using a radioisotope in patients with gastric cancer is a technically feasible and accurate technique, and it is a minimally invasive approach in the assessment of patient nodal status.

Adenocarcinoma↗

Sentinel node mapping for colorectal cancer with radioactive tracer.

PURPOSE: The aim of this study was to test the feasibility and accuracy of radioactivity-guided mapping of the first lymph nodes found in draining the primary tumor site for colorectal cancer. METHODS: We enrolled 56 consecutive patients with preoperative diagnosis of curatively resectable colorectal cancer. Endoscopic injection of technetium Tc 99m-labeled tin colloid (15 MBq) was performed preoperatively, and radioactive sentinel nodes were identified intraoperatively with a gamma probe. Standard radical resection with lymph node dissection was performed in all patients, and all resected nodes were evaluated by routine histopathologic examination. RESULTS: Radioactivity-guided methods were used to detect sentinel nodes in 51 (91 percent) of 56 patients. The number of lymph nodes resected was 23.9 +/- 15.2 per case. The number of sentinel nodes was 3.5 +/- 2.1 (range, 0-8) per case. In 18 of 22 patients with lymph node metastasis, the sentinel node was positive. The incidence of metastasis in the sentinel node (22 percent) was significantly higher than that in nonsentinel nodes (3 percent, P < 0.01). Diagnostic accuracy according to sentinel node status was 92 percent (47/51). Four false-negative cases in this study were advanced cases with T3 primary tumors. The detection rate and diagnostic accuracy for patients with T1 or T2 primary tumors (29 cases) were 100 percent each. CONCLUSION: Intraoperative radioactivity-guided sentinel node mapping was accurate for patients with colorectal cancer with T1 or T2 tumors. The results suggest that sentinel node mapping and intraoperative biopsy may be a sensitive and specific diagnostic method for detecting metastasis in regional lymph nodes in patients with colorectal cancer.

Adult↗

Radioisotope lymph node mapping in nonsmall cell lung cancer: can it be applicable for sentinel node biopsy?

BACKGROUND: Previous studies on intrathoracic lymph node mapping have focused on the validity of a sentinel node concept, but not on the usefulness for sentinel node biopsy. METHODS: The subjects were 15 patients clinically diagnosed with N0 nonsmall cell lung cancer. Technetium-99m tin colloid was injected into the peritumoral area 1 day preoperatively and a time course of tracer migration was monitored by scintigraphy. A hand-held gamma probe counter was used to count the intrathoracic lymph node stations. Resected nodes were also counted to assess the accuracy of the intrathoracic counting. RESULTS: Serial scintigraphies showed that the tracer migrated through airways and the appearance resembled hot nodes. On intrathoracic counting, 50% of the nodal stations appeared positive; however, only 23% of these apparently positive nodal stations were ultimately shown to be truly radioactive. The true positive and true negative rates of detecting intrathoracic hot nodes were 100% and 56%, respectively. Because the counts of the nodal stations could include the counts from the hot primary tumor ("shine-through") or airway radioactivity, legitimate hot nodes were identified after dissecting all the apparently positive nodal stations. Two of the 9 patients in whom hot nodes were identified had nodal metastatic disease and actually had tumor cells within the hot nodes. The only complication related to the preoperative injection of technetium-99m was a minor pneumothorax. CONCLUSIONS: Although radioisotope intrathoracic lymph node mapping is safe, it appears to be unsuitable for sentinel node biopsy because shine-through and the airway-migrated radioactive tracer complicated the intrathoracic counting. Only serial scintigraphy could distinguish hot nodes from airway migration.

Aged↗

Sentinel nodes of malignancies originating in the alimentary tract.

The feasibility of the sentinel node concept for malignancies originating in the alimentary tract is attracting much interest among researchers in the field of gastrointestinal oncology. We have tested more than 350 such cases and obtained favorable and promising initial results. The detectability of sentinel nodes using endoscopically injected Tc-99m tin colloid for these tumors exceeded 90%. Although the false negative ratio was not so low (approximately 10%), most of these cases had an inaccurate preoperative evaluation of mural invasion and/or a technically unfavorable injection. When the indication is restricted to patients with early-stage disease, and when the radioactive colloid is properly administered, sentinel node navigation therapy would be applicable for gastrointestinal malignancies. To achieve successful sentinel node navigation surgery it is essential to accurately identify sentinel nodes, and lymphoscintigraphy is a very useful test to confirm the location of sentinel nodes preoperatively. However, image processing is required for lymphoscintigrams because the original image depicts only high activity at the injection site and faint radioactivity in the sentinel nodes. We have clearly imaged the silhouette of the body using Compton scattered photons, and have also proposed several methods to improve the contrast between the injection sites and sentinel nodes. Many sentinel nodes can be clearly visualized by subtraction of the background activity with heterogeneous distribution. The development of the portable gamma camera, enabling intraoperative imaging, also contributes to less invasive biopsy of sentinel nodes. We have obtained promising initial results using a portable imaging device with semiconductor detectors. These promising results suggest that sentinel node navigation therapy including radiotherapy will be a new therapy for early-stage gastrointestinal malignancies in the near future, with nuclear medicine contributing to the establishment of new, less invasive therapies for gastrointestinal cancer.

Colorectal Neoplasms↗

A preliminary study of the draining lymph node basin in advanced lower rectal cancer using a radioactive tracer.

PURPOSE: This study was designed to examine the draining lymph node basin at highest risk of metastasis in lower rectal cancer using 99 mTc-tin colloid. METHODS: In 43 patients, the area with highest hot nodes density was defined as the draining lymph node basin using a gamma probe. Metastatic states of all removed lymph nodes were examined histologically. RESULTS: A total of 203 hot nodes were identified in 39 patients (91 percent) with a mean of 5.2 nodes. The number of removed lymph nodes was 808 nodes: 670 nodes in the mesorectum, and 138 nodes in the pelvis. In 21 patients, the metastatic states of 119 nodes were investigated histologically. From the distribution of the identified hot nodes, the draining lymph node basins were classified into two patterns: lateral type (n = 17), and mesorectal type (n = 22). Only 20 (17 percent) of 119 positive nodes were identified as hot node. Tumor cells that occupied the lymph node diffusely or massively probably interfered with the exact diagnosis of metastasis. Lymph node metastasis in the pelvis was observed in 5 patients (13 percent). One false negative was of the mesorectal type with diffuse metastases in the para-aortic lymph nodes. The remaining four patients were of the lateral type and all positive lymph nodes, including positive nonhot nodes, were located within the draining lymph node basin. Consequently, in 20 (95.2 percent) of 21 patients with lymph node metastasis, all positive lymph nodes were located within the draining lymph node basin of the tumor. CONCLUSIONS: Two types of the draining lymph node basin of advanced lower rectal cancer were identified using this method. The concordance between lymph node metastases and the draining lymph node basin is good.

Female↗

Sentinel lymph node detection with Tc-99m tin colloids in patients with esophagogastric cancer.

BACKGROUND: The aim of this study was to determine by radioisotope use whether the sentinel lymph node concept is applicable to esophagogastric cancers. In addition, we examined radioactivities of hot nodes and compared them with the sensitivity of a gamma probe. METHODS: The subjects were 44 patients, 23 with esophageal cancer and 21 with gastric cancer. The day before surgery, patients underwent endoscopic submucosal injection of 184 MBq of Tc-99m tin colloids into sites surrounding the tumor. Radioisotope activities of lymph nodes dissected at surgery were measured with a well-typed gamma detector and each lymph node was categorized as a hot or cold node. Histopathology of the lymph nodes was examined by hematoxylin and eosin staining. Radioisotope activities and histopathological results were compared to determine whether radioisotope flow reflects lymphatic flow to regional lymph nodes. The sensitivity of a gamma probe was measured in a laboratory study and the relation between the radioisotope activities of hot nodes and the detection sensitivity of the gamma probe was examined. RESULTS: Histopathological examination revealed lymph node metastasis in 18 of the 44 patients. In 15 of these 18 patients, metastatic foci were recognized in at least one hot node. Subsequent analysis was performed on the 36 patients in whom tumor invasion was confined to the muscle layer and in whom endoscopic clippings had not been applied. Lymph node metastases were observed in 12 of these 36 patients. In these 12 patients, at least one hot node was positive for metastasis. The laboratory study revealed that the gamma probe was able to detect radioisotope activities of >/=0.02 micro Ci. Thirty-two of 63 (51%) esophageal cancer hot nodes and 16 of 86 (19%) gastric cancer hot nodes showed radioisotope activities below the detection sensitivity of the gamma probe. CONCLUSION: The sentinel lymph node concept is applicable to patients with esophageal and gastric cancers; however, further studies are necessary to identify hot nodes accurately using gamma probes.

Colloids↗

Lymphoscintigraphic visualization of internal mammary nodes with subtumoral injection of radiocolloid in patients with breast cancer.

OBJECTIVE: To determine whether subtumoral injection of radiocolloid is useful for lymphoscintigraphic visualization of the internal mammary node and in sentinel lymph node (SLN) biopsy of the axilla in breast cancer patients. SUMMARY BACKGROUND DATA: The presence of retromammary lymphatics connecting to the axillary and internal mammary basins has been demonstrated by early anatomic studies. Thus, it is hypothesized that some lymph, especially that from the parenchyma under the tumor, may drain into both the axillary and internal mammary basins. METHODS: Patients (n = 196) with T1-2, N0 breast cancer underwent preoperative lymphoscintigraphy with radiocolloid (technetium 99m tin colloid) injection into various sites of the breast, followed by SLN biopsy using the combined method with blue dye. Patients were divided into four groups: group A (n = 41), peritumoral injection of both radiocolloid and blue dye; group B (n = 70), periareolar radiocolloid and peritumoral blue dye; group C (n = 45), intradermal radiocolloid and periareolar blue dye; and group D (n = 40), subtumoral radiocolloid and intradermal blue dye. A retrospective analysis of 1,297 breast cancer patients who underwent extended radical mastectomy with internal mammary node dissection was also conducted to determine the relationship between vertical tumor location (superficial or deep) and frequency of axillary and internal mammary node metastases. RESULTS: One patient (2%) in group A, 3 (4%) in group B, 0 (0%) in group C, and 15 (38%) in group D exhibited hot spots in the internal mammary region on lymphoscintigraphy (P <.001, group D vs. the other groups). The concordance rate of radiocolloid and blue dye methods in detection of SLNs in the axillary basin was significantly lower in group D than in the other groups. In contrast, the mismatch rate (some SLNs were identified by radiocolloid and other SLNs were identified by blue dye, but no SLN was identified by both in the same patient) was significantly higher in group D than in the other groups. In patients treated with extended radical mastectomy, positivity of axillary and internal mammary metastases was significantly higher in patients (n = 215) with deep tumors than those (n = 368) with superficial tumors. CONCLUSIONS: These results suggest the presence of a retromammary lymphatic pathway from the deep portion of the breast to both axillary and internal mammary basins, which is distinct from the superficial pathway. Therefore, SLN biopsy with a combination of subtumoral and other (peritumoral, dermal, or areolar) injections of radiocolloid will improve both axillary and internal mammary nodal staging.

Adult↗