Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Refractometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Topology of bovine rotavirus (RF strain) VP6 epitopes by real-time biospecific interaction analysis.

An automated biosensor system designed for measuring molecular interactions in real-time (BIAcore) was used to characterize monoclonal antibodies (Mabs) raised against the inner capsid protein (VP6) of the bovine rotavirus (RF strain). Six Mabs, all reactive in Western blot and in indirect immunofluorescence assays, were mapped, using purified recombinant VP6. These Mabs were delineated into several groups of antibodies. Interactions of selected monoclonal antibodies with purified viral particles were studied by the BIAcore methodology. We showed that some Mabs did not react with single-shelled particles. Conversely, several Mabs reacted with single-shelled particles and one antibody reacted with both single-shelled and double-shelled particles. The latter Mab seemed to interact with VP6 through the holes of the outer capsid and its interaction with the double-shelled particles induced a significant decapsidation. These results allowed a better characterization of the epitopes of VP6. The localization of the epitopes in the viral particle is discussed in comparison with a pepscan study that determined the reactivity of Mabs with nested heptapeptides derived from the whole VP6 molecule.

Amino Acid Sequence↗

Optical diffraction by well-ordered muscle fibres.

We have studied the diffraction of a focussed laser beam by single fibres of glycerinated rabbit psoas muscle as a function of the angle of incidence. Diffraction efficiencies as high as 34% were observed at the first-order Bragg angle, indicative of well-ordered striated fibres with a strong periodic modulation of the refractive index. A theory is presented to account for our observations based upon the coupled-wave model developed by Kogelnik (1967) and Magnusson and Gaylord (1977) for the description of thick phase gratings in holography. We have solved the coupled-wave equations on a computer using a realistic index modulation taken from the measurements of Huxley and Hanson (1957). Comparison of theory with experiment shows that coupled-wave effects are indeed present in well-ordered muscle fibres, and the observed diffraction efficiency is in quite good agreement with what would be expected theoretically. Most importantly, the computer model allows us to calculate the diffraction efficiency for curved striations, which are observed for real muscle fibres under a microscope. The sensitivity of the diffraction efficiency to curvature of the striations may have implications for the interpretation of other optical experiments on muscle. We also consider the effects on our measurements of the focussing lens and refraction by the cylindrical fibre.

Animals↗

[BASIC-Program for calculation of intraocular lens refracting power].

The intraocular power of various types of lenses was calculated, based on different anterior chamber depths. If the lens type planned is changed, the lens power also must be altered, therefore, it is necessary to know the individual difference in diopters. For this purpose, a special computer program in BASIC is introduced, in which there is a table that shows the refraction after implantation of different types of lenses. Possibilities for altering this program are also shown.

Computers↗

[Double refraction of crystals in the lens (spheroliths, "Christmas tree ornaments") and in the vitreous body (scintillatio nivea)].

1. The round, oval, or kidney-shaped, radially built spheroliths of the brown or morgagnian cataract show a double refraction in polarized light of about 0.160 optically positive. This is in accordance with Whewellite (calcium oxalate monohydrate). 2. In crystalline cataracts, there are crystals in polarized light with a mean double refraction of 0.046, which is in accordance with cholesterol (C27H48O). 3. In asteroid hyalinosis of the vitreous, the small bodies consisting of needle-shaped crystals arranged in a radial fashion show a small double refraction of 0.012. Therefore the crystal may be brushite (Ca HPO4 X 2 H2O).

Cataract↗

Reflection versus fluorescence: a note on the physical backgrounds of two types of light microscopy.

Bright microscopic images against a dark background can be originating not only from fluorescence, but also from selective reflection. Selective reflection or scattering of visible light in microscopic preparations can be used for the visualization of sometimes otherwise barely distinguishable material. The images obtained superficially resemble those from fluorescence microscopy. They do not, however, result from huminescence but from selectively reflected light with wavelengths in the region of the absorbance peak of the chromophore present in the stained biological material. The respective backgrounds of the underlying physical phenomena and the conditions under which selective reflection can occur are discussed.

Light↗

Evaluation of image analysis and laser granulometry for microbial cell sizing.

A direct cell size measurement technique and an image analysis based sizing method were developed. The former consisted of a manual size measurement of the two-dimensional cell images on a video screen, with automatic data recording. This method was chosen as the reference. The latter, a semiautomatic method took advantage of a commercial computer program designed for image processing and particle morphology analysis. It gave average and median size values which were compatible with the manual method. However, the performance of these time consuming methods is limited. Hence, the laser granulometry technique, intrinsically far more powerful while capable of analysing millions of sample objects in a short time delay, was applied. The comparison revealed that this method gives too low size values, particularly in disagreement with the known dimensions of the bacterial (Zymomonas mobilis) cells. A size correction method was developed to realign the granulometry results of Z mobilis cell samples with those of the direct manual measurement method.

Bacteria↗

Continuous simultaneous measurement of plasma protein concentration and hematocrit in the alert rat. A short preliminary report.

A method for continuous plasmapheresis and refractometric determination of the protein concentration of blood circulating in the vascular system of the unanesthetized rat is presented. The method is applied to demonstrate very rapid transvascular fluid exchange during physical activity of the animal, noradrenalin infusions and hemorrhage. Changes of protein concentration are compared with concomitant changes of hematocrit in the hepatic portal vein and the v. cava inferior. Though both parameters invariably change in a parallel fashion, relative variations of protein concentration fall short of hot variations by 50%.

Animals↗

Partition coefficients of drugs in bilayer lipid membranes.

The oil/water partition coefficient of drugs is widely accepted as a key parameter in drug design. The coefficients are usually determined using a bulk octanol phase to represent the lipid. The physiologically and pharmacologically relevant structure is, of course, the bilayer lipid membrane, but until now there has been no convenient means of measuring the partition coefficients of small molecules into a single bilayer. This paper demonstrates that the partition coefficient may be calculated from the change in membrane refractive index which occurs when a drug molecule partitions into the membrane. The refractive index is determined by an integrated-optics technique ideally suited to an ultra-thin structure such as a lipid bilayer.

Aspirin↗

Viscosity and refractive index of follicular fluid in relation to in vitro fertilization.

PURPOSE: To set the standard values of follicular fluid viscosity and refractive index, and to investigate a possible relationship between these physiological parameters and the outcome of in vitro fertilization treatment. DESIGN AND RESULTS: 128 samples of follicular fluid were collected from 40 in vitro fertilization patients. Viscosity determinations (centipoise; mean +/- SD) for shear rates of 23, 46, 115, and 230 were 2.04 +/- 0.86, 1.84 +/- 0.49, 1.48 +/- 0.27, and 1.38 +/- 0.22, respectively. The average (+/- SD) refractive index was 1.030 +/- 0.002. There was no significant difference between the values of thawed frozen fluids and fresh samples of the same specimens. The data showed no correlation between follicular fluid viscosity or refractive index and the presence of oocytes, their maturation grade or their fertilizing capacity. CONCLUSIONS: For the first time, values of the viscosity and refractive index of follicular fluid obtained during in vitro fertilization have been determined. However, these preliminary results did not reveal any relationship between the physiological parameters examined and the outcome of in vitro fertilization treatment.

Female↗

A fast, high spatial resolution optical tomographic scanner for measurement of absorption in gel dosimetry.

A fast tomographic optical density measurement system has been constructed and evaluated for application in Fricke 3D gel dosimetry. Although the potential for full three-dimensional radiation dosimetry with Fricke gel dosimeters has been extensively reported, its application has been limited due to a lack of fast optical density measurement systems. In this work, the emphasis of the design has been to achieve a short scan time through the use of precision optics and minimal moving parts. The system has been demonstrated in the laboratory to be able to achieve better than 1mm resolution and a scanning time per tomographic slice of 2.4 seconds. Full volumetric sampling of a 10 cm diameter by 7cm long cylinder can be achieved in 3 minutes. When applied with a Fricke based gel dosimeter a linear response between reconstructed CT number and absolute dose was better than 3%.

Absorption↗

[Documentation of endonasal changes in blood volume using optical rhinometry].

BACKGROUND: In optical rhinometry, the nose is transilluminated with light and the light absorption by the nasal tissue is measured continuously. Using this method, a real time documentation of changes in nasal blood volume is possible. The method has been evaluated using the nasal allergen provocation test. In this study, the ability of optical rhinometry to detect changes in the nasal blood volume due to various posture changes is examined. METHODS: Optical rhinometry was tested on ten healthy probands, with several examinations being performed on each. RESULTS: By bending the neck, lying down or stopping breathing, stronger light extinction was found. Standing up quickly caused a sudden but short decrease in light extinction. A small amount of exercise, such as making a fist several times, decreased light extinction. Harder exercise on an ergometer led to a stronger decrease in light extinction. In the Valsalva maneuver, an increase in light extinction for the duration of the maneuver was observed. Changes in breathing through the nose or mouth or counting from 1 to 100 had no influence. CONCLUSIONS: Using the new method of optical rhinometry, it is possible to detect changes in endonasal blood volume caused by changes of intrathoracic pressure, changes in posture or physical exercise, non-invasively and in real time. This technique can therefore be used for further research on the regulation of the nasal blood flow.

Adult↗

[Laser therapy of the lung: biophysical background].

The laser is a well established surgical instrument in lung therapy. This report provides information on the biophysical basics of the laser-induced thermotherapy (LITT) of lung metastases. Optical properties like absorption and scattering determine the penetration depth of laser radiation in tissue. These parameters vary dynamically during the application and define in combination with thermal tissue properties the achievable destruction volume. Parenchyma behaves very differently compared to more dense tissues due to local inhomogenities and the large amount cavaties filled with air. Beside an account of the affecting parameters an overview of therapy options is given. Therapeutic results depend not only on the tissue properties but also on the technical equipment, e.g. the applicator design and the energy applied. Complex dosimetric models allow for a calculation of the lesion's size in advance.

Animals↗

Trehalose degradation and glucose efflux precede cell ejection during germination of heat-resistant ascospores of Talaromyces macrosporus.

Talaromyces macrosporus forms ascospores that survive pasteurization treatments. Ascospores were dense (1.3 g ml(-1)), relatively dry [0.6 g H(2)O (g dry weight)(-1)] and packed with trehalose (9-17% fresh weight). Trehalose was degraded to glucose monomers between 30 and 100 min after heat activation of the spores. The maximal activity of trehalase was calculated as 400-520 nmol glucose formed min(-1) (mg protein)(-1) as judged by measurements of the trehalose content of spores during germination. During early germination, glucose was released from the cell (10% of the cell weight or more). The intracellular concentration of glucose only peaked briefly. After 160-200 min, the protoplast encompassed by the inner cell wall was ejected through the outer cell wall in a very quick process. Subsequently, respiration of spores increased strongly. The data suggested that trehalose is primarily present for the protection of cell components as glucose is released from the cell. Then, an impenetrable outer cell wall is shed before metabolic activity increases.

Ascomycota↗