Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIUS FRACTURES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Biomechanical efficacy of an internal fixator for treatment of distal radius fractures.

Despite the effectiveness of external fixation in the treatment of complex wrist fractures, the complication rate for this modality ranges from 20% to 62%. Common complications are related to the use of percutaneous metal pins and result in an average reoperation rate of 16%. In addition, external fixation is unable to prevent dorsal collapse of the radius or maintain the normal palmar tilt of the radiocarpal joint surface. This complication may predispose to posttraumatic wrist instability and arthritis. The problems with external fixation have prompted a search for a better treatment option. An internal fixator placed through limited incisions on the dorsal aspect of the radius and spanning the fracture site can, in theory, provide the benefits of external fixation without the associated morbidity. This study determined the biomechanical efficacy of internal fixators compared with external fixators using a standardized model for an unstable wrist fracture. Two commercially available metal plates were used as internal fixators. Biomechanical testing of the devices was done, and stiffness was determined. Results showed that the internal fixators were significantly stiffer than were the external fixators in axial loading. Failure in axial loading, specifically compression, is a consistent reason for loss of reduction in intraarticular distal radius fractures. The clinical implications of these results suggest that an internal fixator theoretically can prevent loss of reduction in the axial plane and maintain palmar tilt by acting as a rigid dorsal buttress. In addition, the use of an internal fixator potentially decreases the high morbidity associated with external fixation. Additional investigation into the clinical application of internal fixators for distal radius fractures is needed.

Biomechanical Phenomena↗

[Pseudarthroses after distal radius fractures. What is the role of the distal radioulnar joint?].

Non-union following distal radial fracture is extremely rare. Therefore, the patterns are not completely understood. Recently, it was suggested that an associated distal ulna shaft fracture increases the risk to develop a non-union for comminuted fractures of the distal radius. The purpose of this study was to review our 15 cases with this condition to investigate the role of an associated distal ulna shaft fracture and/or an associated lesion of the distal radioulnar joint. The second goal was to evaluate the success of the surgical treatment in relation to the extent of the metaphyseal subchondral bone supporting the articular surface distal to the site of the non-union. We reviewed our 15 cases which were operated on for non-union of the distal radius since 1992. In all cases, the radiographs could be reviewed. Twelve patients could actually be re-examined. The investigated criteria were: initial, pre- and postoperative X-ray findings, other medical conditions, range of motion, grip strength, and pain relief. Clinical outcome was evaluated using the DASH-questionnaire. According to the AO classification system, there were two type A3 and 13 type C3 fractures. There were seven associated distal ulna fractures. The distal radioulnar joint was involved in twelve cases. The other medical conditions in the patients with non-union after distal radial fracture included allergy, hypothyroidism, diabetes mellitus, peripheral neuropathy, and bronchial asthma. Four patients were tobacco smokers. Only one patient was initially treated non-operatively. In all cases, the distal radius was restored preserving wrist motion. Bony union was achieved in 14 cases. The range of motion has improved in all planes. Grip strength increased but still remained over 50% below the level of the opposite side. Postoperatively, the majority of patients was pain free. In four cases, complications were seen postoperatively. Three of these patients had less than 6 mm of metaphyseal subchondral bone beneath the articular surface. Three of the four patients were tobacco smokers. Inadequate treatment of a comminuted distal radial fracture associated with a special local situation--such as an additional distal ulna shaft fracture and/or an associated lesion of the distal radioulnar joint--combined with a general medical condition, adversely affects fracture healing, increasing the risk for non-union. From the review of the records of these 15 cases, we recommend that non-union with more than 5 mm of subchondral bone supporting the articular surface distal to the non-union site undergo reconstruction of the radius. Non-union with less than 5 mm subchondral bone supporting the articular surface requires an individual decision. A good bone stock and stable fixation allows for reconstruction of the radius, otherwise wrist fusion is a useful salvage procedure.

Adult↗

[The prospects for Kirschner-wire osteosynthesis in the dorsally unstable distal radius fracture (Colles' type)].

The following experimental study was conducted to develop biocompatible methods of osteosynthesis in fractures of the distal radius and to evaluate their stability. A model of dorsal wedge osteotomy in the distal radial metaphysis was used to develop the surgical technique and to test the stability of the alternative methods of osteosynthesis. The concept for this model was based on commercially available materials which were either biodegradable or osteoconductive. Four different forms of biocompatible osteosynthesis were compared to combined Kirschner wire osteosynthesis (KWO), our preferred method of treatment of unstable Colles fracture. Biocompatible osteosynthesis was achieved with an invasivity and stability comparable to that of KWO. In conclusion, injection osteosynthesis exceeded the other biocompatible methods of osteosynthesis in all respects. Regarding the recent developments in injectable materials for osteosynthesis it offers the best perspective for clinical application.

Biocompatible Materials↗

[Loco typico radius fractures--personal experience].

Fractura radii loco typico (FRLT) is the fracture of the distal radius. That is the one of the most frequent fractures of locomotor system with the widest range of treatment in traumatology. Therapy depends on the stability of the fracture: nonoperative or operative. We analysed the five-year experience of our Department of Traumatology where more than 1500 patients with FRLT have been treated in the urgent surgery clinic and 126 of them were hospitalized. In our study we evaluated the results of the operative treatment and postoperative functional status of a treated wrist. According to the A-O classification, we hospitalized 36 patients with A type, 28 patients with B type, and 62 patients with C type of FRLT. We operated 80 patients. The postoperative functional status of a treated wrist was excellent or good in 64 patients and good in 16 patients. The treatment of FRLT depends on the type and the complications of the fracture and the age of the patients. Operative therapy is indicated in the unstable FRLT or after an inadequate nonoperative treatment.

Colles' Fracture↗

[Distal radius fractures--forms of fracture and injury pattern].

Fractures at the distal end of the radius are the most frequent fractures. There are still many therapeutical problems. The success of conservative or operative treatment depends mainly on the different types of fractures. In order of compare end results and to recommend therapy, it is necessary to define different fracture types, based on practical classification. A classification of fractures at the distal end of the radius is presented, with localization and reference to the extent of injury with consideration of lesions of the radiocarpal joint and indirectly to the distal radio ulnar joint. In the period of growth five types of injuries are differentiated. In adults three main groups, depending on the involvement of the radio-carpal joint are described. These are subdivided according to dislocation. The fractures types were classified by using X-rays of cases over a period of several years. With this classification the pattern of injury of 593 fractures of the distal end to the radius, treated in 1980 in our clinic, was analysed.

Humans↗

Recurrent dorsal angulation of the distal radius fracture during dynamic external fixation.

Thirty-three fractures of the distal radius treated with a dynamic external fixator (that allowed for wrist motion between 2 to 4 weeks after surgery) were analyzed, focusing on loss of fracture reduction during external fixation. Fractures with preoperative dorsal angulation greater than 20 degrees and those involving the distal radioulnar joint had a significantly larger loss of reduction of dorsal angulation (8.9 degrees and 6.9 degrees, respectively) than fractures with less severe preoperative dorsal angulation or those with an intact distal radioulnar joint (3.0 degrees and 2.6 degrees, respectively). In contrast, preoperative radial shortening (>2 mm) and involvement of the radiocarpal joint did not significantly increase the loss of dorsal angulation. Neither of the 2 dynamic external fixation systems studied consistently stabilized Colles' fractures with preoperative dorsal angulation of greater than 20 degrees or involvement of the distal radioulnar joint.

Adult↗

[Distal radius fractures].

Fractures of the distal end of the radius are the most common fractures in humans. The variants of type of fracture and associated injuries are numerous, depending on the mechanism of injury, the amount of energy absorbed and the quality of the bone. Treatment concepts evolve as our understanding of the physiopathology of this heterogeneous group of injuries increases. It is now commonly accepted that extraarticular anatomy and joint congruency, as well as ligamentous integrity, should be restored to obtain a good functional result. This paper provides an overview of current knowledge and discusses possible future trends.

External Fixators↗

Distal radius fractures: mechanisms of injury and strength prediction by bone mineral assessment.

The strength of the radius depends on the mechanical properties of cancellous and cortical bone. By assessing both compartments quantitatively with bone densitometry, we tried to identify the specificity of each in predicting the load at which the distal radius will fracture. Twenty human cadaver forearms were scanned for bone mineral and geometric properties with quantitative computed tomography and dual x-ray absorptiometry. In both a neutral loading situation and one in which the wrist was extended 45 degrees, the load distribution was determined with pressure-sensitive films, and a fracture simulating a fall on the hand was produced with a material testing machine. Fractures that occur with the wrist in extension were produced by a central impact of the scaphoid onto the radiocarpal joint, and those that occur under neutral loading conditions were produced by a more commonly distributed loading pattern. The load at fracture was most specifically predicted (r2=0.74) by bone mineral and geometric measures of the cortex at the shaft of the radius. Bone mineral density measures of trabecular (r2=0.64) and total (r2=0.66) bone were less successful in predicting the fracture load. After adjustment for bone size, the geometric and density measures revealed similar specificity. Cortical bone, therefore, contributes significantly to the strength of the distal radius and may play an important role in the prediction of osteoporotic wrist fractures.

Absorptiometry, Photon↗