Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

The target switch algorithm: a constructive learning procedure for feed-forward neural networks.

We propose an efficient procedure for constructing and training a feed-forward neural network. The network can perform binary classification for binary or analogue input data. We show that the procedure can also be used to construct feedforward neural networks with binary-valued weights. Neural networks with binary-valued weights are potentially straightforward to implement using microelectronic or optical devices and they can also exhibit good generalization.

Algorithms↗

Differences of subcutaneous adipose tissue topography between type-2 diabetic men and healthy controls.

Men with noninsulin-dependent diabetes mellitus (type 2 DM) provide a different subcutaneous body fat distribution and a concentration of fatness on the upper trunk compared with healthy subjects. However, subcutaneous fat distribution is always measured in an inaccurate and/or very simplified way (e.g., by caliper), and to date, there exists no study reporting on the exact and complete subcutaneous adipose tissue distribution of type 2 DM men. A new optical device, the LIPOMETER, enables the nonivasive, quick, and safe determination of the thickness of subcutaneous adipose tissue layers at any given site of the human body. The specification of 15 evenly distributed body sites allows the precise measurement of subcutaneous body fat distribution, so-called subcutaneous adipose tissue topography (SAT-Top). SAT-Tops of 21 men with clinically proven type 2 DM (mean age of 57.5 +/- 6.7 years) and 111 healthy controls of similar age (mean age 59.0 +/- 5.4 years) were measured. In this paper, we describe the precise SAT-Top differences of these two groups and we present the multidimensional SAT-Top information condensed in a two-dimensional factor value plot. In type 2 DM men, especially in the upper trunk, SAT-Top is significantly increased (up to +50.7% at the neck) compared with their healthy controls. One hundred eleven of the 132 individuals (84.1%) are correctly classified (healthy or type 2 DM) by their subcutaneous fat pattern by stepwise discriminant analysis.

Adipose Tissue↗

Subcutaneous adipose tissue pattern in lean and obese women with polycystic ovary syndrome.

The new optical device, Lipometer, permits the noninvasive, quick, safe, and precise measurement of the thickness of subcutaneous adipose tissue (SAT) layers at any given site of the human body. Fifteen anatomically well-defined body sites from neck to calf describe the SAT topography (SAT-Top) like an individual "fingerprint." SAT-Top was examined in 33 women with polycystic ovary syndrome (PCOS), in 87 age-matched healthy controls and in 20 Type-II diabetic women. SAT-Top differences of these three groups were described, and, based on a hierarchical cluster analysis, two distinctly different groups of PCOS women, a lean (PCOS(L)) and an obese (PCOS(O)) cluster, were found. For visual comparison of the different types of body fat distribution, the 15-dimensional body fat information was condensed to a two-dimensional factor plot by factor analysis. For comparison of the PCOS like body fat distribution with the "healthy" fat pattern, the (previously published) SAT-Top results of 590 healthy women and men (20-70 years old) and 162 healthy girls and boys (7-11 years old) were added to the factor plot. PCOS(O) women showed a SAT-Top pattern very similar to that of women with Type-II diabetes, even though the diabetic women were on average 30 years older. Compared with their healthy controls, SAT-Top of these PCOS(O) patients was strongly skewed into the android direction, providing significantly decreased leg SAT development and significantly higher upper body obesity. Compared with healthy women, PCOS(L) patients had significantly lower total SAT development (even though height, weight, and body mass index did not deviate significantly), showing a slightly lowered amount of body fat in the upper region and a highly significant leg SAT reduction. This type of fat pattern is the same as found in girls and boys before developing their sex specific body fat distribution. We conclude that women with PCOS develop an android SAT-Top, but compared in more detail, we found two typical types of body fat distribution: the "childlike" SAT pattern in lean PCOS patients, and the "diabetic" body fat distribution in obese PCOS women.

Adipose Tissue↗

Endoscopic endonasal transsphenoidal surgery.

The endoscopic endonasal transsphenoidal approach is a minimally invasive surgical technique for the removal of sellar and parasellar lesions. The procedure is performed via an anterior sphenoidotomy. The two main characteristics of the endoscopic approach, when compared with the standard microsurgical operation, arise from the use of the endoscope as a unique optical device and from the absence of a transsphenoidal retractor. More convenient straight surgical instruments are employed, whereas bayonet-shaped tools are used in the microsurgical procedure, to avoid any interference with the light beam generated by the microscope. The standard surgical technique is composed of three main time phases: the nasal, sphenoid, and sellar phase. During the nasal phase, the scope is introduced through the chosen nostril and advanced up to the sphenoethmoid recess, where the sphenoidotomy is performed. The sphenoid phase consists of the detachment of the nasal septum from the sphenoid rostrum, the anterior sphenoidotomy, removal of the sphenoid septum or septa, and identification of the landmarks inside the sphenoid sinus. In the sellar phase, an opening of the sellar floor is performed for removal of the lesion. A wide view of the sellar environment is obtained through angled scopes to detect eventual tumor remnants. The procedure ends with the reconstruction of the sella and removal of the endoscope from the nostril, without any postoperative nasal packing.

Adenoma↗

Phase-matched third-harmonic generation in mercury-(I)-chloride.

Using phase-matched third-harmonic generation we determine the effective nonlinear susceptibilities in Hg2Cl2 (Calomel) to /chi(3)eff,I/ = 4.5 x 10(-22) m2V(-2) and /chi(3)eff,II/ = 9.7 x 10(-22) m2V(-2) for type I and type II phase matching, respectively. The type III phase matching uses the same tensor components as type I and is deduced to be /chi(3)eff,III/ approximately equal to 1.5 x 10(-22) m2V(-2). The effective third-order susceptibilities of Hg2Cl2 are two orders of magnitude higher than those of CaCO3, and the tensor components chi11 - 3chi18 exceed the components of ADP by a factor of 5. These measurements demonstrate that Calomel might be a promising material to be used for nonlinear optical devices.

Journal Article↗

Dispersion of barium gallogermanate glass.

Gallogermanate glasses are the subject of intense study as a result of their unique combination of physical and optical properties, including transmission from 0.4 to beyond 5.0 microm. These glasses can be easily made into large optics with high-index homogeneity for numerous U.S. Department of Defense and commercial visible-IR window applications such as reconnaissance, missile domes, IR countermeasures, avionics, and collision avoidance on automobiles. These applications require a knowledge of the refractive index of glass throughout the region of transmission. Consequently, we have measured the refractive index of BaO-Ga2O3-GeO2 glass from 0.4 to 5.0 microm and calculated the Sellmeier coefficients required for optical device design.

Journal Article↗

Rh:BaTiO3 thin films with large nonlinear optical properties.

We report the fabrication and the nonlinear optical properties of Rh-doped BaTiO3 thin films. The films were deposited on SrTiO3 (100) substrates by pulsed-laser deposition. The deposited Rh:BaTiO3 thin films were single phase and c-axis orientation investigated by x-ray diffraction. The films exhibited large nonlinear optical effects, which were determined using Z-scan technique at a wavelength of 532 nm with a laser duration of 10 ns. The real and imaginary parts of the third-order nonlinear susceptibility chi (3) were 5.71 x 10(-7) esu and 9.59 x 10(-8) esu, respectively. The value of Re chi (3) of Rh:BaTiO3 films is much larger than those of several representative nonlinear optical thin films. The results show that Rh:BaTiO3 thin films have great potential applications for nonlinear optical devices.

Journal Article↗

Theoretical study of amplitude and phase filtering of guided waves.

The design of integrated optics filters by use of refinement software based on the Abelès thin-film computation method and the film mode matching method is studied. The results obtained with the two computation methods are compared. Good agreement is obtained provided that the fill factor of the guided mode in the component is high and that modal losses between waveguide sections are simulated by absorption with the Abelès computation method. Integrated optics devices that manage either the amplitude of guided waves such as a dense wavelength division multiplexing narrow-bandpass filter and a gain-flattening filter or the phase of guided waves such as a broadband dispersion compensator are

Journal Article↗

Empirical model for the waveguiding properties of directly UV-written waveguides.

We present an empirical model for the waveguiding properties of directly UV-written planar waveguides in silica-on-silicon. The waveguides are described by a rectangular core step-index profile, in which model parameters are found by comparison of the measured waveguide width and effective index with modal field calculations. The model is used as input for beam propagation method calculations to design UV-written optical components. Subsequent fabrication of such components showed a good agreement with the model predictions. Using the model will reduce the number of iterations and thereby the development time of new optical devices.

Journal Article↗

Optical true time delay for phased-array antennas: demonstration of a quadratic White cell.

We have demonstrated a proof-of-concept optical device that can produce true time delays for a phased-array radar. This device combines White cells of differing lengths with a spatial light modulator to select between the paths on multiple bounces of a given beam. The approach can handle thousands of light beams and produce hundreds of different delays. The number of delays is proportional to the square of the number of bounces.

Journal Article↗

Photoelastic and acousto-optical properties of Cs2HgCl4 crystals.

We use a Mach-Zehdner interferometric technique to study the piezo-optical properties of Cs2HgCl4 crystals at room temperature. All piezo-optical (pi(mn)) and photoelastic (p(in)) tensor constants are obtained. A substantial photoelastic effect and low ultrasonic velocities in these crystals determine a relatively high figure of merit M2 for isotropic diffraction (for a certain geometry of acousto-optical interactions, M2 approximately 110 x 10(-15) s3/kg). The new material may be considered, therefore, a candidate for applications in acousto-optical devices. The dependence of the acoustic walk-off angle on the direction of sound propagation is calculated for the principal crystallographic planes.

Journal Article↗

Long-period gratings in planar optical waveguides.

We present a theoretical analysis of light propagation in a four-layer planar waveguide that consists of a long-period grating (LPG) having a period of the order of 100 microm. By means of the coupled-mode theory, we show that such a structure is capable of coupling light from the fundamental guided mode to the cladding modes at specific wavelengths (resonance wavelengths) and thus results in sharp rejection bands in the transmission spectrum of the waveguide. Our numerical results show that the resonance wavelengths as well as the transmission spectrum can be significantly changed with the waveguide and grating parameters. A waveguide-based LPG should provide a useful approach to the design of a wide range of integrated-optic devices, including wavelength-tunable filters, switches, and environmental sensors.

Journal Article↗

Angstrom-range optical path-length measurement with a high-speed scanning heterodyne optical interferometer.

A highly accurate method of optical path-length measurement is introduced by use of a scanning heterodyne optical interferometer with no moving parts. The instrument has demonstrated the potential to measure optical path length at angstrom resolution over continuous thickness in the micrometer range. This optical path length can be used to calculate the thickness of any material if the refractive index is known or to measure the refractive index of the material if the thickness is known. The instrument uses a single acousto-optic device in an in-line ultra-stable reflective geometry to implement rapid scanning in the microsecond domain for thickness measurements of the test medium.

Journal Article↗

SYMNET: an optical interconnection network for scalable high-performance symmetric multiprocessors.

We address the primary limitation of the bandwidth to satisfy the demands for address transactions in future cache-coherent symmetric multiprocessors (SMPs). It is widely known that the bus speed and the coherence overhead limit the snoop/address bandwidth needed to broadcast address transactions to all processors. As a solution, we propose a scalable address subnetwork called symmetric multiprocessor network (SYMNET) in which address requests and snoop responses of SMPs are implemented optically. SYMNET not only has the ability to pipeline address requests, but also multiple address requests from different processors can propagate through the address subnetwork simultaneously. This is in contrast with all electrical bus-based SMPs, where only a single request is broadcast on the physical address bus at any given point in time. The simultaneous propagation of multiple address requests in SYMNET increases the available address bandwidth and lowers the latency of the network, but the preservation of cache coherence can no longer be maintained with the usual fast snooping protocols. A modified snooping cache-coherence protocol, coherence in SYMNET (COSYM) is introduced to solve the coherence problem. We evaluated SYMNET with a subset of Splash-2 benchmarks and compared it with the electrical bus-based MOESI (modified, owned, exclusive, shared, invalid) protocol. Our simulation studies have shown a 5-66% improvement in execution time for COSYM as compared with MOESI for various applications. Simulations have also shown that the average latency for a transaction to complete by use of COSYM protocol was 5-78% better than the MOESI protocol. SYMNET can scale up to hundreds of processors while still using fast snooping-based cache-coherence protocols, and additional performance gains may be attained with further improvement in optical device technology.

Journal Article↗

Breast cancer detection by mapping hemoglobin concentration and oxygen saturation.

Near-infrared (NIR) spectroscopic imaging technology provides a new modality for measuring changes in total hemoglobin concentration (HbT) and blood oxygen saturation (SO2) in human tissue. The technology can be used to detect breast cancer because cancers may cause greater vascularization and greater oxygen consumption than in normal tissue. Based on the NIR technology, ViOptix, Inc., has developed an optical device that provides two-dimensional mapping of HbT and SO2 in human tissue. As an adjunctive tool to mammography, the device was preliminarily tested in a clinical trial with 50 mammogram-positive patients at the Massachusetts General Hospital. The results of the clinical trial demonstrate that the device can reach as much as 92% diagnostic sensitivity and 67% specificity in detecting ductal carcinoma. These results may indicate that the NIR technology can potentially be used as an adjunct to mammography for breast cancer detection to reduce the number of biopsies performed.

Adult↗

Six-degrees-of-freedom alignment technique that provides diagnostic misalignment information.

We introduce a new six-degrees-of-freedom alignment technique that enables the precise alignment of two optical device planes. The method combines linear diffraction gratings and cylindrical Fresnel lenses that allow the diagnosis of misalignment in each degree of freedom independently. The technique was used to align two 20 mm x 20 mm fused-silica substrates separated by 17 mm. The worst-case alignment precision was found to be better than +/- 5 microm laterally, +/- 20 microm longitudinally, +/- 0.036 degrees rotationally, and +/- 0.007degrees in tilt.

Journal Article↗

Correction of wave-front errors caused by the slight tilt of a reference beam in phase-shifting interferometry.

In standard phase-shifting interferometry the reference beam is supposed to be a plane wave exactly normal to the recording plane. A slight tilt of the reference beam, however, may occur in practice, and it will introduce phase distortion for the reconstructed object wave front. The effects of reference wave tilt on the wave reconstruction are analyzed, and a novel method is proposed to correct the errors caused by this tilt. This method is simple and convenient without the need of any additional optical devices and measurements, and it can be used for both the smooth and the diffuse object surfaces. The effectiveness of this method is verified by a series of computer simulations.

Journal Article↗

Control of spatial polarization by use of a liquid crystal with an optically treated alignment layer and its application to beam apodization.

We have investigated the alignment of a liquid crystal whose orientation is controlled by photoisomerization reaction for use in developing optical devices to improve beam quality. A glass window of a liquid-crystal cell that is coated with poly(vinyl alcohol) doped with azo dye was illuminated with a Hg lamp. We confirmed the dependence of the spatially controlled alignment direction of a liquid crystal on the irradiation time of this ultraviolet light. The new azo dye used in this study substantially reduced the illumination energy density required for aligning liquid-crystal molecules. We have demonstrated the control of polarization and successfully fabricated a serrated apodizing aperture and a soft aperture.

Journal Article↗