Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Models, Cardiovascular”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

A time-of-flight method of measuring flow velocity by magnetic resonance imaging.

A new time-of-flight method for direct imaging of flow velocities by magnetic resonance is presented. The technique uses selective exciting and refocusing RF pulses to selectively affect planes oriented in orthogonal directions in space, with the region of excitation perpendicular to the flow and the refocusing region parallel to and including the flow. The positions of the sources of the resulting spin echoes are imaged, showing a displacement equal to the product of the velocity and the echo time. These images clearly show the profile of the velocity distribution, both in laminar and nonlaminar flows.

Blood Flow Velocity↗

MR imaging of model fluid velocity profiles.

A projection MR technique for imaging the velocity profiles of moving fluids has been applied to various steady flow models designed to simulate a variety of flow conditions. From such profiles can be readily deduced peak velocities, volume flow rates, information concerning the degree of flow development, features such as flow separation, and estimates shear stresses at the vessel wall.

Blood Flow Velocity↗

Spatially resolved flow velocity measurements and projection angiography by adiabatic passage.

This paper describes the basic principles of gradient modulated adiabatic passage using a CW radiofrequency excitation. The possible applications of this technique include a direct assessment of in-plane and oblique directional flow velocities, and visualization of flow velocity profiles. Flow angiography based on the time-of-flight technique is also discussed with experimental results.

Angiography↗

Quantification of complex flow using MR phase imaging--a study of parameters influencing the phase/velocity relation.

In this study, we describe how motion-induced phase angle is affected by different flow models and imaging parameters when using the MR flow phase mapping technique. In a phantom with straight as well as constricted tubes, simulating healthy and stenotic vessels, nonpulsatile flow in the velocity range 0-1 m/sec was maintained. The phase/velocity relation was studied for various degrees of complex flow caused by the constriction, and regions with a breakdown in linearity were determined. Further studies in these regions were made regarding the influence of pulse sequence parameters on the phase/velocity relation. The results showed that in poststenotic areas characterized by so-called separated flow, the phase/velocity relation became nonlinear due to dephasing effects. In regions with fully developed turbulent flow in straight tubes, however, no breakdown in linearity was observed. Parameters seen to have a substantial influence on the phase/velocity relation were first- and second-order velocity encoding and voxel size. Finally, a pilot in vivo demonstration of complex flow was done using a sequence designed to be robust with respect to linearity of the phase/velocity relation. The results indicate that the MR phase mapping technique can be used to measure flow quantitatively in regions with complex flow. This opens possibilities for future clinical use of the technique in the study of areas of complex flow such as valvular heart disease.

Aortic Valve Stenosis↗

Flow field mapping by multi-zone adiabatic passage excitation.

This paper describes a robust method for flow field mapping by multi-zone adiabatic fast passage (AFP). It provides a quick and simple way to simultaneously acquire flow profiles at several locations and arbitrary orientations inside the field-of-view. The flow profile is the time-averaged evolution of the labeled flowing material. Results obtained using a carotid bifurcation and jet phantoms are similar to the previous experimental studies employing Laser Doppler Anemometry (LDA), and other flow visualization techniques. In addition, the preliminary results obtained with a human volunteer support the feasibility of the technique for in vivo flow quantification.

Blood Flow Velocity↗

Chordal geometry determines the shape and extent of systolic anterior mitral motion: in vitro studies.

In patients with hypertrophic cardiomyopathy, the mitral valve moves anteriorly and assumes a unique shape, with mitral-septal contact centrally and preserved valve orifice area laterally. This shape is not clearly predicted by the Venturi mechanism, which stresses flow above the valve as opposed to changes intrinsic to the valve. On the other hand, it has been suggested that displacement of the papillary muscles anteriorly and toward one another, as observed in this disease, can promote anterior mitral valve motion and produce this unusual shape. The purpose of this in vitro study was to test the hypotheses that anterior motion of a membrane in a flow field can be generated by altering the distribution or effectiveness of chordal tension tethering the membrane, and that the shape achieved by this membrane depends on the geometry of chordal tension. Accordingly, a horizontal leaflet mounted in a flow chamber was attached by chords at its distal end to a series of upstream screws. Chordal tension could be varied by turning the screws or redirected by shifting the screws anteriorly. Anterior leaflet motion having the same unusual configuration seen in patients was reproduced by decreasing central chordal restraint while tension on the leaflet edges was maintained. Directing chordal tension anteriorly caused greater degrees of anterior motion at earlier stages in the release of chordal restraint; increased flow rate had a similar but less marked effect. These studies suggest that primary geometric alterations in the papillary-mitral apparatus can play an important role in determining the presence and geometry of systolic anterior mitral motion. The nature of these alterations suggests a role for anterior and inward papillary muscle displacement in promoting such motion. The geometric factors embodied in this model can explain many observed features of this motion not adequately explained by the Venturi effect, such as early systolic onset and the importance of a distal residual leaflet. Finally, flow visualization studies emphasize the importance in this process of drag forces caused by interposing the leaflet into the flow stream, and of geometric factors that enhance such forces.

Cardiomyopathy, Hypertrophic↗

Factors influencing the structure and shape of stenotic and regurgitant jets: an in vitro investigation using Doppler color flow mapping and optical flow visualization.

To evaluate factors influencing the structure and shape of stenotic and regurgitant jets, Doppler color flow mapping and optical flow visualization studies were performed with use of a syringe model with a constant rate of ejection to simulate jets of valvular regurgitation and a pulsatile flow model of the right heart chambers to simulate jets of mild, moderate and severe valvular pulmonary stenosis. Ink-(0 to 40%) glycerol-water jets (viscosity 1 to 3.5 centiPoise) were produced by injecting the fluid at a constant rate into a 10 gallon rectangular reservoir of the same still fluid through 1.4 and 3.4 mm needles. The Doppler color flow scanners imaged the laminar jet length within 3 mm of actual jet length (2 to 6 cm) and the jet width within 2 to 3 mm of the actual jet width. Jet flows with Reynolds numbers ranging from 230 to 1,200 injected into still fluid yielded jet length/width ratios that decreased with increasing Reynolds numbers and leveled off to a length/width ratio of 5-6:1 at a Reynolds number near 600. When the fluid reservoir was swirled to better mimic the effect of flow entering the same cardiac chamber from a second source, the jets showed diminution of the jet length/width ratio and a clearly defined zone of turbulence. Studies of the pulsatile flow model were performed at cardiac outputs of 1 to 6 liters/min for the normal and each stenotic valve. Mild stenosis had an orifice area of 2.8 cm2, moderate stenosis an area of 1.0 cm2 and severe stenosis an area of 0.5 cm2. Laminar jet length represented the length of the total jet, which had a symmetric width and was measured from the valve opening to a region where the jet exhibited a spray effect. Laminar jet lengths (0.2 to 1.1 cm) were imaged by Doppler color flow mapping and optical visualization only in the moderate and severely stenotic valves and only at flows less than or equal to 3 liters/min (mean Reynolds numbers less than or equal to 3,470). Beyond this flow rate the jets exhibited a spray effect. Laminar jet length/width ratio approached unity with an increased amount of valvular stenosis and higher flow volumes (cardiac output). Proximal aliasing was present in each valve studied. the length of aliasing (0 to 3.2 cm) proximal to the valve was longer with increased flow rates and increased amounts of stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Blood Flow Velocity↗

Pressure recovery distal to a stenosis: potential cause of gradient "overestimation" by Doppler echocardiography.

Doppler ultrasound is currently being widely applied to measure intracardiac pressure gradients noninvasively. In comparative invasive studies, it is generally assumed that pressure is effectively uniform distal to the stenosis. As the poststenotic jet expands, however, its velocity decreases, and pressure is recovered to the extent permitted by turbulence, so that the measured gradient will be lower if the distal catheter is positioned downstream from the vena contracta. This can lead to apparent Doppler "overestimation" of the pressure gradient because of this phenomenon of pressure recovery. This study demonstrates that pressure recovery can be important in a variety of clinical settings studied by in vitro models. Although most prominent in streamlined tunnels modeled after the obstruction in patients with hypertrophic cardiomyopathy, these effects are important even for central stenoses at physiologic flow rates. Because precise catheter position is not always known or controlled, these findings suggest an important advantage for Doppler gradient estimation, because it provides the maximal gradient at the vena contracta, which determines the load on the proximal chamber.

Cardiomyopathy, Hypertrophic↗

Influence of orifice geometry and flow rate on effective valve area: an in vitro study.

Fluid dynamics suggests that orifice geometry is a determinant of discharge properties and, therefore, should influence empiric constants in formulas (such as the Gorlin formula) to calculate stenotic valve area. An in vitro study utilizing a model of transmitral flow was conducted to investigate how the discharge coefficient changes with 1) orifice eccentricity (ratio of long to short diameter), 2) absolute area, 3) the presence of a nozzle-like inlet, and 4) varying flow. Twenty-three orifices with areas varying between 0.3 and 2.5 cm2 and eccentricities from 1:1, or circular, to 5:1, or elliptic, were tested. The calculated discharge coefficients ranged between 0.675 and 0.93. For a given area, the discharge coefficient decreased by a mean value (+/- SD) of 5.5 +/- 1.3% between circular orifices and 5:1 ellipses. Discharge coefficients increased by a mean of 8.9 +/- 3.5% from 0.3 to 2.5 cm2 area within each eccentricity class. A gradually tapering inlet (nozzle) raised the discharge coefficient by 8.8 +/- 3.9%, leading to a discharge coefficient between 0.81 and 0.93 for round orifices. The discharge coefficient did not change appreciably with flow. The concept of the discharge coefficient and its role in assessing restrictive orifices in general by hydraulic formulas (for example, the Gorlin and pressure half-time calculations) are discussed.

Blood Flow Velocity↗

Arteriographic evaluation of small coronary arteries.

The purpose of this study was to determine the accuracy of imaging small coronary arteries with current radiographic equipment. Phantom assessments were performed using a phantom that comprises a large array of circular objects of varying diameter and contrast density. More objects could be identified in the moving cinearteriogram than in single cine frames. Using the largest object as the calibration standard, diameters less than 1 mm were markedly overestimated. A simple morphometric method showed that arteriographic visualization of small vessels was better by digital processing than by cine recording. However, there was no statistically significant difference in the average size of the smallest identifiable vessel by either method (0.5 versus 0.51 mm). After correcting for overestimation and the inaccurate imaging of the smallest detectable vessels, the practical arteriographic threshold is approximately 0.5 mm. Parametric imaging holds promise, but its significance for evaluating small vessel disease has yet to be determined.

Angiography↗

Analysis of the early transmitral Doppler velocity curve: effect of primary physiologic changes and compensatory preload adjustment.

Left ventricular filling (as assessed by Doppler echocardiography) has previously been shown to depend in a complex fashion on ventricular diastolic function (compliance and relaxation) as well as other variables, such as atrial pressure and compliance, ventricular systolic function and mitral valve impedance. To study the effect of isolated physiologic alterations on individual Doppler indexes, a mathematic model of mitral flow was analyzed. By varying one physiologic variable at a time, it was shown that mitral velocity acceleration is affected directly by atrial pressure and inversely by the ventricular relaxation time constant, with relatively little impact of chamber compliance. Deceleration rate was directly influenced by mitral valve area, atrial pressure and ventricular systolic dysfunction and inversely affected by atrial and ventricular compliance relations, with little impact of relaxation unless it was so delayed as to be incomplete during deceleration. Peak velocity was directly affected most strongly by initial left atrial pressure, and lowered somewhat by prolonged relaxation, low atrial and ventricular compliance and systolic dysfunction. Strikingly different filling patterns emerged when the primary physiologic alterations were accompanied by simultaneous compensatory changes in atrial pressure designed to maintain stroke volume constant. Low ventricular compliance with preload compensation produced characteristic E waves with very short acceleration and deceleration times and high peak velocity. Thus, mathematic analysis of ventricular filling helps to explain the physical and physiologic basis for the transmitral velocity curve.

Blood Flow Velocity↗

Amplitude information from Doppler color flow mapping systems: a preliminary study of the power mode.

The flow of a saline-glycerin solution with sand particles through a continuous in vitro flow system was imaged by using two commercially available Doppler color flow mapping systems in a power mode (Toshiba SSH-160A and Advanced Technology Laboratories [ATL] Ultramark 9). The images generated from seven solutions with particle concentrations ranging from 0.0001 x 10(12) to 6 x 10(12) particles/liter and a mean velocity of 30 cm/s measured with use of pulsed Doppler ultrasound were used to examine the dependence of the power mode on particle concentration. To examine the velocity dependence, 20 mean velocities ranging from 0.1 to 0.53 m/s (3 to 30 liters/min) and three particle concentrations (1, 3 and 6 x 10(12) particles/liter) in the solution were used. The recorded images were digitized and analyzed off-line. The SUM values, or the adjusted color intensity levels in delineated areas of interest in the displayed flow, were compared. In general, the power mode was sensitive in displaying slower velocity flows; in the selected particle concentration and velocity ranges, it was both velocity and concentration dependent. The specific dependence differed for the two color flow mapping systems.

Blood Flow Velocity↗

Effective aortic regurgitant orifice area: description of a method based on the conservation of mass.

The natural history of aortic regurgitation is incompletely understood in part because of the lack of a simple method to estimate the defect size. A method of determining the effective regurgitant orifice area that combines Doppler catheter and Doppler echocardiographic techniques and is based on the principle of conservation of mass (the continuity equation) is described. To validate the application of the Doppler catheter system for measuring regurgitant supravalvular diastolic flow, an in vitro model of retrograde aortic flow was used. These studies indicated that measurements of supravalvular retrograde velocity with the Doppler catheter accurately reflect retrograde diastolic velocity when the aorta is less than 4.8 cm in diameter. Twenty-three patients undergoing cardiac catheterization were studied; 20 of these patients had aortic regurgitation. Retrograde supravalvular diastolic velocity was determined from a Doppler catheter positioned above the aortic valve. The effective regurgitant orifice area was calculated with use of the Doppler catheter-derived regurgitant volume and mean transvalvular diastolic velocity as determined by either catheterization or continuous wave Doppler echocardiography. The catheterization-derived regurgitant orifice area increased with the angiographic grade of as follows: 1+ (0.04 to 0.10 cm2), 2+ (0.15 to 0.49 cm2), 3+ (0.29 to 1.11 cm2) and 4+ (1.24 to 1.33 cm2). By combining Doppler catheter, echocardiographic and cardiac catheterization techniques, the effective aortic regurgitant orifice area may be estimated; this hydrodynamic area correlates with grading by supravalvular aortography. Calculation of this area provides a quantitative alternative to aortography for estimating the severity of aortic regurgitation but should be used with caution in patients with a markedly dilated aorta.

Aortic Valve Insufficiency↗

Errors in pressure gradient measurement by continuous wave Doppler ultrasound: type, size and age effects in bioprosthetic aortic valves.

The accuracy of continuous wave Doppler ultrasound in deriving pressure gradients across bioprosthetic heart valves was evaluated in an in vitro pulse duplicator. Simultaneous pressure transducer and Doppler measurements were made in new and explanted aortic bioprosthetic valves of several sizes and four types: Carpentier-Edwards, Ionescu-Shiley, Hancock standard and Hancock modified. The mean and peak gradients calculated by the modified Bernoulli equation from Doppler velocity measurements were always greater than those measured manometrically, despite corrections for location dependence of the manometric gradient (or pressure recovery). The relation between manometric and ultrasonically determined gradient was found to be statistically dependent on the valve type (mean gradient p less than 0.0001; peak gradient p = 0.0003) and size (mean gradient p = 0.0089; peak gradient p = 0.0107). Effects of implantation were observed, but were not shown to be significant. It is concluded that the continuous wave Doppler velocity data overestimated prosthetic valve pressure gradient in all cases, even when pressure recovery was taken into account. Clinicians should be wary of Doppler data when making major diagnostic or therapeutic decisions.

Aortic Valve↗

Impact of orifice geometry on the shape of jets: an in vitro Doppler color flow study.

To investigate the influence of orifice geometry on the three-dimensional shape of jets, an in vitro Doppler color flow study was performed. Jets were formed by discharging blood through round orifices and through orifices with major/minor axis ratios of 2:1, 3:1 and 5:1. These were repeated with orifice areas of 0.1, 0.3 and 0.5 cm2. For turbulent and laminar jets formed by these orifices, Doppler color flow images were obtained from two orthogonal scanning planes aligned with the major and minor orifice axes. Jet width was measured at 1 cm intervals from 0 to 5 cm from the orifice and used to calculate jet eccentricity (ratio of major to minor axis widths) and the rate of divergence of the jet walls. Jets were observed to diverge more rapidly along walls aligned with the orifice minor axis rather than along the major axis. This differential spreading led to the development of circular symmetry at a short distance from the orifice. Jet divergence (theta) occurred more rapidly for turbulent jets and for jets formed by larger orifices: theta (zero) = 0.80 + 6.3.A + 7.0.T + 0.47.E-OR (r = 95, p less than 0.0001, n = 48), where A is orifice area (cm2); T is 0 for laminar jets, 1 for turbulent jets and E-OR combines orifice eccentricity and scanning orientation, ranging from -5 for 5:1 orifices imaged along the major axis, 0 for circular orifices to 5 for 5:1 orifices imaged along the minor axis. Within the jet, eccentricity decayed approximately exponentially with distance from the orifice, more rapidly for turbulent jets, more slowly for the larger and more eccentric orifices.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Flow Velocity↗

Direct quantitation of right and left ventricular volumes with nuclear magnetic resonance imaging in patients with primary pulmonary hypertension.

To test the utility of electrocardiographically gated spin echo nuclear magnetic resonance (NMR) imaging in quantitating right and left ventricular volumes and function in patients with primary pulmonary hypertension, right and left ventricular end-diastolic and end-systolic volumes, stroke volumes and ejection fractions were determined in 11 patients with primary pulmonary hypertension and in 10 subjects with normal echocardiographic findings. Ventricular chamber volumes were computed by summing the ventricular chamber volumes of each NMR slice at end-diastole and end-systole. This technique was verified by comparison of results obtained by this method and with the water displacement volumes of eight water-filled latex balloons and ventricular casts of eight excised bovine hearts. In the patients with primary pulmonary hypertension, right ventricular volume indexes were 121 +/- 45 ml/m2 at end-diastole and 70.1 +/- 41.6 ml/m2 at end-systole; both values were significantly greater than values in the normal subjects (67.9 +/- 13.4 and 27.9 +/- 7.5 ml/m2, respectively). Left ventricular end-diastolic volume index was significantly less in the patients (44.9 +/- 9.7 ml/m2) than in the normal subjects (68.9 +/- 13.1 ml/m2). There was no significant difference in left ventricular end-systolic volume between the two groups (24.4 +/- 8.6 and 27.1 +/- 7.8 ml/m2, respectively). Right and left ventricular ejection fractions in the patients with primary pulmonary hypertension (0.43 +/- 0.21 and 0.46 +/- 0.15, respectively) were significantly less than values in normal subjects (0.59 +/- 0.09 and 0.6 +/- 0.11, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A new integrated system for three-dimensional echocardiographic reconstruction: development and validation for ventricular volume with application in human subjects.

OBJECTIVES: The purpose of this study was to improve three-dimensional echocardiographic reconstruction by developing an automated mechanism for integrating spark gap locating data with corresponding images in real time and to validate use of this mechanism for the measurement of left ventricular volume. BACKGROUND: Initial approaches to three-dimensional echocardiographic reconstruction were often limited by inefficient reconstructive processes requiring manual coordination of two-dimensional images and corresponding spatial locating data. METHODS: In this system, a single computer overlays the binary-encoded positional data on the two-dimensional echocardiographic image, which is then recorded on videotape. The same system allows images to be digitized, traced, analyzed and displayed in three dimensions. This system was validated by using it to reconstruct 11 ventricular phantoms (19 to 271 ml) and 11 gel-filled excised ventricles (21 to 236 ml) imaged in intersecting long- and short-axis views and by apical rotation. To measure cavity volume, a surface was generated by an algorithm that takes advantage of the full three-dimensional data set. RESULTS: Reconstructed cavity volumes agreed well with actual values: y = 0.96x + 2.2 for the ventricular phantoms in long- and short-axis views (r = 0.99, SEE = 2.7 ml); y = 0.95x + 2.9 for the phantoms, reconstructed by apical rotation (r = 0.99, SEE = 2.7 ml); and y = 0.99x + 0.11 ml for the excised ventricles (reconstructed in long- and short-axis views; r = 0.99, SEE = 5.9 ml). The mean difference between three-dimensional and actual volumes was 3% of the mean (3.0 ml) for the phantoms and 6% (4.6 ml) for the excised ventricles. Observer variability was 2.3% for the phantoms and 5.6% for the excised ventricles. Application to 14 normal subjects demonstrated feasibility of left ventricular reconstruction, which provided values for stroke volume that agreed well with an independent Doppler measure (y = 0.97x + 0.94; r = 0.95, SEE = 3.2 ml), with an observer variability of 4.9% (2.4 ml). CONCLUSIONS: A system has therefore been developed that automatically integrates locating and imaging data in no more time than the component two-dimensional echocardiographic scans. This system can accurately reconstruct ventricular volumes in vitro over a wide range and is feasible in vivo, thus laying the foundation for further applications. It has increased the efficiency of three-dimensional reconstruction and enhanced our ability to address clinical and research questions with this technique.

Adult↗

Clinical significance and origin of artifacts in transesophageal echocardiography of the thoracic aorta.

OBJECTIVES: The aim of this study was to identify the mechanism and features of artifacts encountered during transesophageal echocardiography of the aorta. BACKGROUND: Artifacts are an important potential limitation of transesophageal echocardiography of the aorta. METHODS: The mechanism of the artifacts was examined by in vitro modeling. The frequency and clinical correlates of artifacts were examined by retrospective review of transesophageal echocardiograms in 36 patients with aortic pathologic lesions. RESULTS: Two classes of artifact were seen: linear artifacts in the ascending aorta, which may mimic intimal flaps, and mirror image artifacts in the transverse and descending thoracic aorta. Linear artifacts in the ascending aorta, seen in 44% of patients, were shown in vitro to be multiple path artifacts caused by reflection of ultrasound within the left atrium. Linear artifacts in the ascending aorta were associated with dilatation of the ascending aorta and were more frequent when the aortic diameter exceeded the left atrial diameter (p < 0.001). The mirror image artifacts of the transverse and descending thoracic aorta give the appearance of a double-barrel aorta and were shown in vitro to be caused by the aorta-lung interface, which acts as a total reflector of ultrasound. Mirror image artifacts were seen in > 80% of patients. Artifacts were equally frequent with the sagittal and transverse imaging planes when biplane transesophageal echocardiography was used. CONCLUSIONS: Artifacts occur frequently during transesophageal echocardiography of the aorta. An understanding of why they occur and the features that distinguish them from true abnormalities should enhance the diagnostic accuracy of transesophageal echocardiography for aortic disease.

Adult↗