Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Friction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Improvement of the friction behaviour of NiTi orthodontic archwires by nitrogen diffusion.

The lack of low friction coefficient for the NiTi superelastic archwires makes difficult the optimal use of these materials in orthodontic applications. In this study, the decrease of this friction coefficient has been achieved by means of nitrogen diffusion heat treatments. The titanium nitride coating has been characterised by means of optical and scanning electron microscopy. Transformation temperatures, critical stresses, hardness and friction coefficient have been determined. Besides, the metallic ion release studies showed that the titanium nitride coating prevents biodegradation.

Biocompatible Materials↗

Poly-vinyl alcohol hydrogel vascular models for in vitro aneurysm simulations: the key to low friction surfaces.

PURPOSE: To develop a vessel model with poly-vinyl alcohol hydrogel (PVA-H) with low surface friction for in vitro simulations of vascular pathologies. MATERIALS AND METHODS: Simulations of variable vascular pathologies were based on human vessel casts reproduced in wax. Constructions of vascular models were then obtained by lost wax techniques. As materials, liquid silicon or PVA in organic solvents were used. After solidification, the wax was drained by heating. Comparison of PVA-H with silicone models included evaluation of surface characteristics (friction coefficient), of visibility (transparence and compatibility with medical imaging techniques), and of stiffness (pulsatility of vascular lumen). Both model types were integrated in a circulation circuit allowing for flow simulations and testing with endovascular medical devices. RESULTS AND CONCLUSION: Both model types were transparent and compatible with current medical imaging methods. PVA-H models exhibited much lower friction characteristics. PVA-H stiffness was closer to soft tissue when compared to silicone, allowing for pulsations during flow simulations.

Friction↗

Frictional asymptomatic darkening of the extensor surfaces.

Frictional asymptomatic darkening of the extensor surfaces (FADES), also known as hyperkeratosis of the elbows and knees, is commonly seen by dermatologists but has never been well characterized. Patients present with uniform, asymptomatic, brown darkening over the extensor surfaces of the elbows and knees with minimal scaling. Both frictional stress and family history may play a role in the pathogenesis of this condition. The results of cutaneous biopsy specimens typically reveal hyperkeratosis, acanthosis, and mild papillomatosis with minimal inflammation. Keratolytic agents such as lactic acid and urea cream along with avoiding frictional stress can be effective in the management of this condition. We describe a series of cases of FADES and its etiology and management options.

Adult↗

Bidirectional friction study of cancellous bone-porous coated metal interface.

Bidirectional friction tests between cancellous bone cubes and a porous-coated metal plate were performed to determine the mechanical properties of the interface required in 3-dimensional (3-D) finite element model studies of cementless implants. Bone specimens were obtained from different proximal regions of four resurfaced cadaveric tibiae. A beaded porous-surfaced plate similar to those used in implants was used. Tangential loads in perpendicular directions with different magnitudes were applied at the interface in the presence of constant normal pressure, and the displacements were monitored in the same directions. Measured results showed that the interface load-displacement curve is highly nonlinear with significant coupling between two perpendicular directions. The interface friction coefficient (defined as the ratio of the maximum resultant tangential force divided by the normal load) was found to remain nearly unchanged with the relative magnitude of tangential stresses and the bone location. Moreover, bidirectional tests suggested that the load-displacement relation when evaluated for resultant values is similar to that obtained in a unidirectional testing condition. Constitutive equations that account for the cross-stiffness coupling terms between perpendicular directions were also developed. These relations were used in a 3-D finite element model study of preceding bidirectional friction tests. The influence of the coupling terms on results was investigated by comparison of predictions with measurement results. A satisfactory agreement was found between the results of the experiments with those of finite element studies confirming the constitutive relations as well as the importance of coupling terms.

Aged↗

Dielectric friction as a mechanism for selectivity alteration in capillary electrophoresis using acetonitrile-water media.

The mobilities of a series of aromatic carboxylates and sulfonates, ranging in charge from -1 to -4, were investigated as a function of acetonitrile concentration in the electrophoretic buffer. Absolute mobilities were determined by extrapolation of the effective mobilities to zero ionic strength according to the Pitts' equation. In general, anions of higher charge were more strongly influenced by ionic strength, with similarly charged anions experiencing ionic strength effects that were not significantly different at the 95% confidence level. Furthermore, the relative magnitudes of the Onsager slopes varied with acetonitrile content according to the z/(etaepsilon(1/2)) dependence in the electrophoretic effect of the Pitt's equation. Addition of acetonitrile to the electrophoretic media resulted in changes in the absolute mobilities of the anions. These acetonitrile-induced selectivity alterations were attributed to dielectric friction. As predicted by the Hubbard-Onsager model of dielectric friction, changes in sulfonate mobility were shown to correlate to changes in solvent viscosity (eta), dielectric constant (epsilon), and relaxation time (tau). The combined effects of ionic strength and dielectric friction caused analytes with higher charge-to-size ratios to be slowed to a greater extent upon addition of acetonitrile compared to those with lower charge-to-size. For example, at 75% acetonitrile and 20 mM ionic strength, a migration order reversal occurred between the triply and singly charged sulfonates.

Acetonitriles↗

Measurements of friction injuries in man.

Repetitive frictional insults over years to human skin result in lichenification, callosites, and clavi (corns). No measurements of the forces involved have been made for callosites or corns. Two reports deal with lichenification produced by repeated rubbing over weeks. By contrast, friction blisters have been seriously studied because they can be produced in minutes and because foot blisters can disable soldiers. Three devices to measure the coefficient of friction of materials on man's skin and eight machines to rub man's skin are reviewed.

Biophysical Phenomena↗

Study of the DNA/ethidium bromide interactions on mica surface by atomic force microscope: influence of the surface friction.

The influence of mica surface on DNA/ethidium bromide interactions is investigated by atomic force microscopy (AFM). We describe the diffusion mechanism of a DNA molecule on a mica surface by using a simple analytical model. It appears that the DNA diffusion on a mica surface is limited by the surface friction due to the counterion correlations between the divalent counterions condensed on both mica and DNA surfaces. We also study the structural changes of linear DNA adsorbed on mica upon ethidium bromide binding by AFM. It turns out that linear DNA molecules adsorbed on a mica surface are unable to relieve the topological constraint upon ethidium bromide binding. In particular, strongly adsorbed molecules tend to be highly entangled, while loosely bound DNA molecules appear more extended with very few crossovers. Adsorbed DNA molecules cannot move freely on the surface because of the surface friction. Therefore, the topological constraint increases due to the ethidium bromide binding. Moreover, we show that ethidium bromide has a lower affinity for strongly bound molecules due to the topological constraint induced by the surface friction.

Adsorption↗

Imaging friction tracks at diamond surfaces using reflection electron microscopy.

Reflection electron microscopy (REM) is applied to image the structure of polished natural diamond (001) surfaces (of 5 x 4 mm size) after friction experiments under a pressure below the critical value. Friction tracks marked by a diamond needle after a single pass movement under a pressure of 13 GPa can be seen in REM images and show non-uniform contrast. The surface shows relatively dark image contrast at the light contacted area, which is possibly due to the structural modification at the top atomic layer. The high local contacting pressure pushes part of the needle into the surface which causes fracture, resulting in the formation of grooves at the surface. It is possible to have plastic deformation in this process, but no evidence has been found for the presence of cracking. The observations support the adhesion frictional mechanism rather than the micro-cleavage model.

Carbon↗

Frictional transition of pesticides from protective clothing.

Frictional transition of pesticides, the transition of the dried pesticide due to rubbing, from protective clothing was investigated by using an AATCC standard crockmeter. One insecticide (carbaryl) and two herbicides (atrazine and metolachlor) were studied, together with three protective clothing materials [cotton, polyester, and polyester/cotton (65/35) blend] and three crock fabrics (cotton, nylon, and silk). The effects of the properties of pesticide, fabrics, water, and perspiration on the frictional transition are discussed. The experiment showed that up to 12% of the pesticide could transfer from contaminated protective clothing to the skin through rubbing. Choosing the right materials for protective clothing and underwear would greatly decrease the frictional transition of the pesticide.

Laundering↗

Ultrastructural and physico-chemical heterogeneities of yeast surfaces revealed by mapping lateral-friction and normal-adhesion forces using an atomic force microscope.

Scanning force microscopy has been used to probe the surface of the emerging pathogenic yeast Candida parapsilosis, in order to get insight into its surface structure and properties at submicrometer scales. AFM friction images eventually show patches with a very strong contrast, showing high lateral interaction with the tip. Adhesion force measurement also reveals a high normal interaction with the tip, and patches show extraordinarily high pull off values. The tip eventually sticks completely at the center of the patches. While an extraordinarily high interaction is measured by the tip at those zones, topographic images show extraordinarily flat topography over those zones, both of which characteristics are consistent with a liquid-like area. High resolution friction images show those zones to be surrounded by microfibrillar structures, concentrically oriented, of a mean width of about 25 nm, structures that become progressively less defined as we move away from the center of the patches. No structure can be appreciated inside the zones of maximum contrast. Also some helical or ribbon-like structure can be resolved from friction images. There is not only an ordered disposition of the microfibrillar structures, but also the adhesion force increases radially in the direction towards the center of the patches. These structures responsible for the high adhesion are thought to be incipient-emerging budding zones. Microfibrillar structures are thought to represent the first steps of chitin biosynthesis and cell wall digestion, with chitin polymers being biosynthesized, associated with other macromolecules of the yeast cell wall. They can be also beta glucan helical structures, made visible in the zone of yeast division due to the action of autolysins. The observed gradient in surface adhesion and elastic properties correlates well with that expected from a biochemical point of view. The higher adhesion force measured could be either due to the different macromolecular nature of the patches, or to a mechanical adhesion effect due to the different plasticity of that zone. This work reveals the importance of taking into account the dynamic nature of the cell wall physico-chemical properties. Processes related to the normal cell-cycle, as division, can strongly alter the surface morphology and physico-chemical properties and cause important heterogeneities that might have a profound impact on the adhesion behavior of a single cell, which could not be detected by more macroscopic methods.

Candida↗

Frictional properties and molecular weight of native and synthetic myosin filaments from vertebrate skeletal muscle.

1. The molecular weights of a series of synthetic myosin filaments have been measured, using the transport-concentration dependence theory of Rowe, A.J. [Biopolymers, 1977, 16, 2595--2611]. It is shown that for preparations of narrow length distribution (0.60--0.77 micrometer), N, the number of myosin molecules/14.3 nm varies between 3 and 6. 2. The reduced specific viscosity of synthetic myosin filaments has been measured as a function of both concentration and shear rate. From the concentration dependence at zero rate of shear, a value for the "swelling" of the filaments Vs/-v = 2.3 has been calculated. 3. The frictional coefficient of synthetic myosin filaments has been shown to be anomalously but reproducibly high, as compared to that of prolate ellipsoids of the same length and mass. This additional frictional drag has been numerically characterised by a "frictional increment", fi = 1.76 +/- 0.11. 4. A procedure has been devised whereby for any elongated structure which can be assumed to show the same (or other known) fi value, the molecular weight can be estimated from s0 (extrapolated sedimentation coefficient) and 2b (length) alone. 5. An s0 value for natural A-filaments, isolated from rabbit psoas muscle, has been determined by the active enzyme centrifugation technique. From this value, s0 = 132 +/- 3 S, a molecular weight of 1.20 . 10(8) has been computed by the new procedure, for preparations of average length 1.27 micrometer. 6. Contingent upon the validity of the assumptions used (see 4 above) the N value is computed as 3.1 +/- 0.2, consistent with the native, fully intact A-filament having three-fold symmetry, containing 294 myosin molecules, and having a molecular weight based upon myosin and C-protein of 1.31 . 10(8).

Adenosine Triphosphatases↗

Frictional interface micromotions and anisotropic stress distribution in a femoral total hip component.

A numerical model of a femoral total hip component based on the finite element method is developed to evaluate the relative micromotions at the bone-implant interface and the stress distribution in the femoral bone. The interface is modelled as unilateral contact involving Coulomb's dry friction between the bone and the implant. In addition, the model includes inhomogeneity, anisotropy as well as plasticity of both cortical and spongious bones. An automatic data processor coupled to a three-dimensional mesh generator is designed to extract cortical bone geometry and inhomogeneous distribution of trabecular bone density from data obtained with quantitative computed tomography (QCT). A preliminary application is conducted to evaluate the mechanical behaviour of an existing bone-prosthesis structure for two typical loadings: a load simulating the single leg stance and a load simulating the stair climbing stance. The obtained results are subdivided in two parts. Firstly, the characterization of stress transfer and micromotions at the bone-stem interface. The peak value of the shear micromotions reaches 600 microns in the proximal medial region with a friction coefficient equal to 0.6. An analysis of the influence of the friction coefficient reveals that the shear and distractive micromotions as well as the shear and normal stresses depend strongly on this coefficient. Secondly, the representation of stresses in the femoral bone. Determination of complementary invariants such as the hydrostatic pressure, the deviatoric stress and anisotropic stresses brings additional insights in the evaluation of the stress field in the femoral bone.

Activities of Daily Living↗

Effects of sliding velocity on the coefficients of friction in a model orthodontic system.

Four arch wire alloy products were evaluated against 400- or 600-grit finished stainless steel contact flats at 34 degrees C under prevailing atmospheric conditions. Six relative velocities (10, 1.0, 0.1, 5 x 10(-2), 5 x 10(-3), and 5 x 10(-4) mm/min) were evaluated as many as three times each in order to simulate a range of sliding motion which approaches the mean rate of tooth motion--that of 2.3 x 10(-5) mm/min. Measurements of the static and kinetic coefficients of friction were rather invariant for the stainless steel and nickel titanium arch wire products. In contrast, a slight increase and a definite decrease of both coefficients occurred for the cobalt-chromium and the beta-titanium arch wire products, respectively. On the presumption that tooth motion routinely occurs over a wide range of sliding rates, the stainless steel couple produced the lowest and the most consistent coefficients of friction, whereas the beta-titanium wire on stainless steel flats produced the highest and the most erratic coefficients of friction. These observations should prevail whenever the film layer of saliva breaks down at, for example, the contact points of arch wire and bracket wings.

Chromium Alloys↗

Low-frictional catheter materials by photo-induced graft polymerization.

To develop low-frictional catheters, photo-induced graft polymerization of N,N-dimethylacrylamide (DMAA) was performed on to films and tubes of ethylene-vinyl acetate copolymer (EVA) and poly(vinyl chloride) (PVC). Their surfaces became very slippery, when the materials were preirradiated with UV from a low-pressure mercury lamp, followed by graft polymerization with DMAA in the presence of small amount of riboflavin without degassing. Although no significant difference was observed in surface lubrication between the EVA film and the tube, the latter required an additional procedure for the graft polymerization, that is, removal of air trapped inside the tube. The surfaces of EVA and PVC tubes grafted with DMAA were found to exhibit frictional forces around 0.5 N against a PVC and a silicone surface under wet conditions, whereas the frictional force of the ungrafted tubes against the same substrates was 10 and 20 N for PVC and EVA, respectively.

Catheterization↗

Ion implantation effects on friction and wear of joint prosthesis materials.

The literature contains many results from in vitro friction and wear tests for simulating the behaviour of human joint prostheses. However, they are difficult to correlate, even when they are not contradictory. In friction tests, several friction-mechanisms occur when the Ti-6AI-4V titanium alloy rubs against the UHMWPE polyethylene. Corrosion effects which increase wear happen when the 316L stainless steel is used in Ringer's solution. Ion implantation surface treatments have been performed on these three materials. When the operating conditions were optimized, an important reduction of wear and corrosion was observed. The property improvements are due to structural modifications in a thin layer of the materials.

Alloys↗

The friction constants of bundle-like particles in solution.

In our previous experimental work the following was found: an I-Z-I particle, having a bundle-like macromolecule composed of many thin filaments of actin, had a much larger rotational friction constant than that of a single sarcomere having a more compact bundle-like structure composed of not only actin but also myosin filaments. In this paper, the reason for such a large friction constant of I-Z-I is elucidated by a simple theory (based on the Helmholtz principle in hydrodynamics) in terms of the solvent permeability through the particles. It is demonstrated that if the filaments on the bundle surface are composed of flexible segments, each of which has a local Brownian rotation, the solvent-flow along the surface is strongly depressed because of increased energy dissipation and the solvent permeates through the bundle. The large friction constant of an I-Z-I is suggested to be due to this effect. This situation is very different from that of a single sarcomere without flexible filaments on the surface.

Actins↗

Generalization of the Spiegler-Kedem-Katchalsky frictional model equations of the transmembrane transport for multicomponent non-electrolyte solutions.

The Spiegler-Kedem-Katchalsky frictional model equations of the transmembrane transport for systems containing n-component, non-ionic solutions is presented. The frictional interpretation of the phenomenological coefficients of membrane and the expressions connecting the practical coefficients (Lp, sigma i, omega ij) with frictional coefficients (fij) are presented.

Biological Transport↗