Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Construction and characterization of different MutS fusion proteins as recognition elements of DNA chip for detection of DNA mutations.

Three MutS fusion systems were designed as the mutation recognition and signal elements of DNA chips for detection of DNA mutations. The expression vectors containing the encoding sequences of three recombinant proteins, Trx-His6-GFP-(Ser-Gly)6-MutS (THGLM), Trx-His6-(Ser-Gly)6-Strep tagII-(Ser-Gly)6-MutS (THLSLM) and Trx-His6-(Ser-Gly)6-MutS (THLM), were constructed by gene slicing in vitro. THGLM, THLSLM and THLM were then expressed in Escherichia coli AD494(DE3), respectively. SDS-PAGE analysis revealed that each of the expected proteins was approximately 30% of the total bacterial proteins. The recombinant proteins were purified to the purity over 90% by immobilized metal (Co2+) chelation affinity chromatography. Bioactivity assay indicated that three fusion proteins retained the mismatch-binding activity and the functions of other fusion partners. DNA chips arrayed both mismatched and unpaired DNA oligonucleotides as well as rpoB gene from Mycobacterium tuberculosis were prepared. THGLM, THLSLM and THLM that was labeled with Fluorolinktrade mark Cy3 reactive dye, were then used as both mutation recognition and labeling elements of DNA chips. The resulting DNA chips were used to detect the mismatched and unpaired mutations in the synthesized oligonucleotides and single base mutation in rpoB gene of M. tuberculosis that is resistant to rifamycin.

Carbocyanines↗

Immunoassays based on microelectrodes arrayed on a silicon chip for high throughput screening of liver fibrosis markers in human serum.

A novel immunoassays for screening of disease markers in human serum are presented by miniaturizing interdigitated array (IDA) of microelectrodes via micro electro-mechanical system (MEMS) on a silicon chip for multi-channel electrochemical measurement. Different selected antibodies (Abs) are incorporated site-specifically into the electrochemically deposited polypyrrole (PPy) formed on the IDA of the silicon chip, which was characterized by fluorescence microscope photo and the electrochemical quartz crystal microbalance (EQCM) measurements. The selective recognition of Ab to the corresponding antigen (Ag) is monitored through the measurable conductivity change, which is directly visualized by cyclic voltammograms (CVs) in presence of the redox probe, Fe (CN)6(3-/4-). By using the strategy presented here, three liver fibrosis markers, hyaluronic acid (HA), lamin (LN) and collagen type IV (IV-C), are detected simultaneously and specifically at the surface of the chip with calibration curves, y = 21.75 + 0.84x (R = 0.995), y = 57.54 + 0.47x (R = 0.999) and y = 37.92 + 0.28x (R = 0.999), separately. Either the standard or the serum samples can be detected at ng/mL concentration level in a tiny amount of volume, approximately 50 microL. The chip-based immunoassay shows the advantages of high sensitivity, good specificity, high throughput, low sample consumption, and the stability offered via batch production by MEMS as well, which is expected to benefit the multi-target screening of desired clinical analytes.

Biomarkers↗

Optimizing recombinant antibody function in SPR immunosensing. The influence of antibody structural format and chip surface chemistry on assay sensitivity.

BACKGROUND: Recombinant antibody fragments are valuable tools for SPR-based detection of small molecules such as illicit drugs. However, the multiple structural formats of recombinant antibody fragments are largely uncharacterised with respect to their respective performance in SPR sensing. We have expressed a model anti-M3G antibody in both scFv and chimeric Fab formats to examine its sensitivity and binding profiles in a microplate immunoassay format and Biacore. We have further examined the influence of scFv multimerisation, Fab constant region stability and SPR chip surface coating chemistry, on anti-hapten SPR assay development. RESULTS: Under optimised competition ELISA conditions, the anti-M3G scFv was found to have an IC(50) value of 30 ng/ml, while the most stable Fab construct exhibited an IC(50) value of 2.4 ng/ml. In SPR competition assay on an M3G-OVA-coated SPR chip surface, the two constructs again differed in sensitivity, with IC(50) values of 117 and 19 ng/ml for the scFv and Fab, respectively (the scFv also exhibiting poor linearity of response). However, when the SPR chip surface was directly coated with M3G, both antibody constructs exhibited good linearity of response, similar high sensitivity IC(50) values (scFv 30 ng/ml, Fab 14 ng/ml) and high reproducibility (50 effective regenerations for M3G-OVA, 200 for M3G direct). During SPR assay development it was noticed that scFv and Fab constructs gave differing off-rate profiles. Subsequent HPLC, ELISA and electrophoretic analyses then confirmed that a portion of the scFv population multimerises. Bivalent scFv was found to profoundly affect the dissociation curve for scFv in stringent SPR kinetic analyses, leading to a 40-fold difference in calculated off-rate values (Fab off rate 4.7 x 10(-3)S(-1), scFv off rate 1.03 x 10(-2)S(-1)). CONCLUSION: The structural format of recombinant antibody fragments and chip functionalisation methodology can both profoundly affect the function of anti-M3G SPR assay, with direct coating and Fab format proving to be optimal. The confirmation of scFv multimerisation and resulting changes in SPR kinetics profile, in comparison with a Fab, further suggest that caution must be taken in the interpretation of SPR sensorgrams, which are commonly used in the 'affinity ranking' of scFv panels in which the extent of dimerisation in each sample is unknown.

Animals↗

Determination of free sulfite in wine by zone electrophoresis with isotachophoresis sample pretreatment on a column-coupling chip.

This work deals with the determination of free sulfite in wine by zone electrophoresis (ZE) with on-line isotachophoresis (ITP) sample pretreatment on a column-coupling (CC) chip with conductivity detection. A rapid pre-column conversion of sulfite to hydroxymethanesulfonate (HMS), to minimize oxidation losses of the analyte, was included into the developed analytical procedure, while ITP and ZE were responsible for specific analytical tasks in the separations performed on the CC chip. ITP, for example, eliminated the sample matrix from the separation compartment and, at the same time, provided a selective concentration of HMS before its transfer to the ZE stage of the separation. On the other hand, ZE served as a final separation (destacking) method and it was used under the separating conditions favoring a sensitive conductivity detection of HMS. In this way, ITP and ZE cooperatively contributed to a 900 microg/l concentration detectability for sulfite as attained for a 60 nl load of wine (a 15-fold wine dilution and the use of a 0.9 microl sample injection channel of the chip) and, consequently, to the determination of free sulfite when this was present in wine at the concentrations as low as 3 mg/l. The separations were carried out in a closed separation compartment of the chip with suppressed hydrodynamic and electroosmotic flows. Such transport conditions, minimizing fluctuations of the migration velocities of the separated constituents, made a frame for precise migration and quantitation data as achieved for HMS in both the model and wine samples. Ninety percent recoveries, as typically obtained for free sulfite in wine samples, indicate promising potentialities of the present method as far as the accuracies of the provided analytical results are concerned.

Calibration↗

Novel multi-depth microfluidic chip for single cell analysis.

A novel multi-depth microfluidic chip was fabricated on glass substrate by use of conventional lithography and three-step etching technology. The sampling channel on the microchip was 37 microm deep, while the separation channel was 12 microm deep. A 1mm long weir was constructed in the separation channel, 300 microm down the channel crossing. The channel at the weir section was 6 microm deep. By using the multi-depth microfluidic chip, human carcinoma cells, which easily aggregate, settle and adhere to the surface of the channel, can be driven from the sample reservoir to the sample waste reservoir by hydrostatic pressure generated by the difference of liquid level between sample and sample waste reservoirs. Single cell loading into the separation channel was achieved by applying a set of pinching potentials at the four reservoirs. The loaded cell was stopped by the weir and precisely positioned within the separation channel. The trapped cell was lysed by sodium dodecyl sulfate (SDS) containing buffer solution in 20s. This approach reduced the lysing time and improved the reproducibility of chip-based electrophoresis separations. Reduced glutathione (GSH) and reactive oxygen species (ROS) were used as model intracellular components in single human carcinoma cells, and the constituents were separated by chip-based electrophoresis and detected by laser-induced fluorescence (LIF). A throughput of 15 samples/h, a migration time precision of 3.1% RSD for ROS and 4.9% RSD for GSH were obtained for 10 consecutively injected cells.

Fluorescence↗

Analysis of human hippocampus gangliosides by fully-automated chip-based nanoelectrospray tandem mass spectrometry.

Modern microfluidic devices are currently introduced in electrospray (ESI) mass spectrometry (MS), tending to substitute the classical capillary-based ESI infusion. Automated systems using the combination of robotized sample handling and chip-based ESI are significantly increasing the analysis reproducibility, precision, throughput, and efficiency. In the last couple of years our group developed the chip-based ESI-MS approach for glycomics in biomedical research and applied it for oligosaccharide, glycopeptide and ganglioside investigation. Here we report upon the optimization and application of this modern technique for the analysis of differential ganglioside expression patterns in human fetal and adult hippocampus. By this methodology, ganglioside species exhibiting high degree of heterogeneity in the ceramide motifs and biologically-relevant modifications could be identified in human hippocampus. The ultra-high reproducibility of the experiments uniquely provided by the chip-ESI approach allowed for a reliable MS-based ganglioside comparative assay. Moreover, the particular feature of chip ESI-tandem MS to provide structural information at high sensitivity was useful for detailed characterization of hippocampus-associated species. The experimental data presented in this study indicate the benefits of microfluidic/MS for determination of the topospecific brain ganglioside composition and development-related changes in their expression, which might be of high value in clinical investigation and for studies related to ganglioside-based therapy of central nervous system diseases.

Adult↗

Field amplified sample stacking coupled with chip-based capillary electrophoresis using negative pressure sample injection technique.

A multi-T microchip for integrated field amplified sample stacking (FASS) with CE separation to increase the chip-based capillary electrophoresis (chip-based CE) sensitivity was developed. Volumetrically defined large sample plug was formed in one step within 5s by the negative pressure in headspace of the two sealed sample waste reservoirs produced using a syringe pump equipped with a 3-way valve. Stacking and separation can proceed only by switching the 3-way valve to release the vacuum in headspace of the two sample waste reservoirs. This approach considerably simplified the operations and the equipments for FASS in chip-based CE systems. Migration time precisions of 3.3% and 1.3% RSD for rhodamine123 (Rh123) and fluorescien sodium salt (Flu) in the separation of a mixture of Flu and Rh123 were obtained for nine consecutive determinations with peak height precisions of 4.8% and 3.4% RSD, respectively. Compared with the chip-based CE on the cross microchip, the sensitivity for analysis of FlTC, FITC-labeled valine (Val) and Alanine (Ala) increased 55-, 41- and 43-fold, respectively.

Alanine↗

Evaluation of the CombiChip Mycobacteria Drug-Resistance detection DNA chip for identifying mutations associated with resistance to isoniazid and rifampin in Mycobacterium tuberculosis.

The CombiChip Mycobacteriatrade mark Drug-Resistance Detection DNA chip, recently developed by GeneIn (Pusan, South Korea), is an oligonucleotide microchip coupled with polymerase chain reaction for the detection of mutations associated with resistance to isoniazid (INH) and rifampin (RIF). This oligonucleotide chip was compared with DNA sequencing and phenotypic drug susceptibility testing with 69 INH- and/or RIF-resistant and 27 all tested drug-susceptible Mycobacterium tuberculosis isolates. Two selected codons (the katG codon 315 and inhA15) allowed identification of 84.1% of INH-resistant isolates and 100% of RIF resistance were detected by screening for 7 codons: rpoB511, rpoB513, rpoB516, rpoB522, rpoB526, rpoB531, and rpoB533. The overall specificity of this oligonucleotide chip for detecting INH and RIF resistance were 100 and 95.3%, respectively. This level of sensitivity and specificity is concordant with that from the determination of M. tuberculosis drug resistance by DNA sequencing. This oligonucleotide chip is a rapid and reliable genotypic method capable of detecting multiple mutations associated with INH and RIF resistance simultaneously in a single microchip slide.

Antitubercular Agents↗

CHIP interacts with heat shock factor 1 during heat stress.

Heat shock factor 1 (HSF1) is a major transactivator of heat shock genes in response to stress and mediates cell protection against various harmful conditions. In this study, we identified the interaction of CHIP (carboxyl terminus of the heat shock cognate protein 70-interacting protein) with the N-terminus of HSF1. Using GST full-down assay, we found that CHIP directly interacts with C-terminal deleted HSF1 (a.a. 1-290) but not with full-length HSF1 under non-stressed conditions. Interestingly, interaction of CHIP with full-length HSF1 was induced by heat shock treatment. The structural change of HSF1 was observed under heat stressed conditions by CD spectra. These observations demonstrate the direct interaction between HSF1 and CHIP and this interaction requires conformational change of HSF1 by heat stress.

Binding Sites↗

Chip calorimetry for the monitoring of whole cell biotransformation.

Efficient control of whole cell biotransformation requires quantitative real-time information about the thermodynamics and kinetics of growth and product formation. Heat production contains such information, but its technical application is restricted due to the high price of calorimetric devices, the difficulty of integrating them into existing bio-processes and the slow response times of established microcalorimeters. A new generation of chip or nanocalorimeters may overcome these weaknesses. We thus tested a highly sensitive chip calorimeter for its applicability in biotechnological monitoring. It was used to monitor aerobic growth of suspended and immobilized Escherichia coli DH5alpha DSM 6897 and anaerobic growth of suspended Halomonas halodenitrificans CCM 286(T). The chip data corresponded well with enthalpy balance calculations and measurements with a conventional calorimeter, indicating the applicability of the chip calorimeter for bio-process control.

Anaerobiosis↗

The design and application of DNA chips for early detection of SARS-CoV from clinical samples.

BACKGROUND: SARS coronavirus has been identified as the cause of severe acute respiratory syndrome (SARS). Few tests allow confirmation or exclusion of SARS within the first few days of infection. A gene chip is a useful tool for the study of microbial infections mainly for its capability of performing multi-target analysis in a single test. OBJECTIVES: Investigate the possibility of early detection of SARS virus from clinical samples using the gene chip-based method. STUDY DESIGN: We purified RNA from SARS-CoV obtained from routinely collected peripheral blood and sputum samples of 34 patients who had been identified as probable SARS patients by following the interim U.S. case definition. Four segments of the SARS-CoV were amplified using reverse transcription-nested PCR and the products examined using the 70-mer gene chips for SARS-CoV detection. RESULTS: A blind-test of both peripheral blood and sputum specimens lead to the positive detection of SARS-CoV in 31 out of 34 patients. SARS-CoV was not found in peripheral blood or sputum specimens from three patients. Two of the 34 patients were only 3 days post-onset of symptoms and were subsequently confirmed to be SARS positive. Our results indicate that the gene chip-based molecular test is specific for SARS-CoV and allows early detection of patients with SARS with detection rate about 8% higher than the single PCR test when the sputum sample is available.

Blood↗

An adaptable microvalving system for on-chip polymerase chain reactions.

On-chip genetic analysis systems are beginning to provide a viable alternative to conventional gene profiling and amplification devices, through minimal reagent use, high detection resolution, and the potential for high-throughput parallel testing of the genetic material, even from single cells. Despite the advantages, there are many difficulties inherent in creating an integrated microfluidic diagnostic platform. One major challenge is the accurate control and manipulation of fluid, and particularly the immobilization of reaction mixtures during heating phases of polymerase chain reactions (PCR). In this paper we present a pumping and valving system based on the use of three servomotor-controlled valve fingers that actuate microchannels within a poly-dimethylsiloxane (PDMS) fluidic chip. We characterize the valving ability of the system in terms of fluid loss and show the successful fluid retention of the system over 35-cycle PCR runs at temperatures of up to approximately 96 degrees C. In addition, we demonstrate the system's ability to perform PCR by successfully amplifying a sample of beta2 microglobulin transcript obtained from the peripheral blood of a patient with multiple myeloma. This work has proven to be a successful approach to multi-use valving and a viable method of alleviating the fluid control difficulties inherent in performing a PCR reaction in an on-chip environment. In addition, it opens the door for further automation and integration with other chip-based genetic analysis platforms.

Humans↗

Confirmation of E. coli among other thermotolerant coliform bacteria in paper mill effluents, wood chips screening rejects and paper sludges.

Paper sludges are solid wastes material generated from the paper production, which have been characterized for their chemical contents. Some are rich in wood fiber and are a good carbon source, for example the primary and de-inking paper sludges. Others are made rich in nitrogen and phosphorus by pressing the activated sludge, resulting from the biological water treatments, with the primary sludge, yielding the combined paper sludge. Still, in the absence of sanitary effluents very few studies have addressed the characterization of their coliform microflora. Therefore, this study investigated the thermotolerant coliform population of one paper mill effluent and two paper mill sludges and wood chips screening rejects using chromogenic media. For the first series of analyses, the medium used was Colilert broth and positive tubes were selected to isolate bacteria in pure culture on MacConkey agar. In a second series of analyses, double selective media, based on ss-galactosidase and ss-glucuronidase activities, were used to isolate bacteria. First, the presence of thermotolerant coliforms was detected in low numbers in most water effluents, but showed that the entrance of the thermotolerant coliforms was early in the industrial process. Also, large numbers of thermotolerant coliforms, i.e., 7,000,000 MPN/g sludge (dry weight; d.w.), were found in combined sludges. From this first series of isolations, bacteria were purified on MacConkey medium and identified as Citrobacter freundii, Enterobacter sp, E. sakazakii, E. cloacae, Escherichia coli, K. pneumoniae, K. pneumoniae subsp. rhinoscleromatis, K. pneumoniae subsp. ozaenae, K. pneumoniae subsp. pneumoniae, Pantoea sp, Raoultella terrigena, R. planticola. Second, the presence of thermotolerant coliforms was measured at more than 3,700-6,000 MPN/g (d.w) sludge, whereas E. coli was detected from 730 to more than 3,300 MPN/g (d.w.) sludge. The presence of thermotolerant coliform bacteria and E. coli was sometimes detected from wood chips screening rejects in large quantities. Also, indigenous E. coli were able to multiply into the combined sludge, and inoculated E. coli isolates were often able to multiply in wood chips and combined sludge media. In this second series of isolations, API20E and Biolog identified most isolates as E. coli, but others remained unidentified. The sequences of the 16S rDNA confirmed that most isolates were likely E. coli, few Burkholderia spp, but 10% of the isolates remained unidentified. This study points out that the coliform bacteria are introduced by the wood chips in the water effluents, where they can survive throught the primary clarifier and regrow in combined sludges.

DNA, Bacterial↗

Gene chips and arrays revealed: a primer on their power and their uses.

This article provides an overview and general explanation of the rapidly developing area of gene chips and expression array technology. These are methods targeted at allowing the simultaneous study of thousands of genes or messenger RNAs under various physiological and pathological states. Their technical basis grows from the Human Genome Project. Both methods place DNA strands on glass computer chips (or microscope slides). Expression arrays start with complementary DNA (cDNA) clones derived from the EST data base, whereas Gene Chips synthesize oligonucleotides directly on the chip itself. Both are analyzed using image analysis systems, are capable of reading values from two different individuals at any one site, and can yield quantitative data for thousands of genes or mRNAs per slide. These methods promise to revolutionize molecular biology, cell biology, neuroscience and psychiatry. It is likely that this technology will radically open up our ability to study the actions and structure of the multiple genes involved in the complex genetics of brain disorders.

DNA, Complementary↗

Microfluidic chip-based method for genotyping microsatellites, VNTRs and insertion/deletion polymorphisms.

We have developed a method to genotype variable number of tandem repeats (VNTRs) and insertion/deletion polymorphisms using an integrated microfluidic chip-based system. We used this method to analyze a) a highly polymorphic pentanucleotide repeat (CCTTT)(n) locus within the 5'-putative promoter region of the human inducible nitric oxide synthase gene (iNOS5) which is associated with diabetic complications and infectious diseases; b) a bi-allelic 27 bp VNTR region within intron 4 of endothelial nitric oxide gene (eNOS27) which is associated with hypertension in type 2 diabetes patients with coronary heart disease and excess risk of advanced diabetic nephropathy in type 1 diabetes patients and c) an insertion/deletion polymorphism within the gene encoding angiotensin-converting enzyme (ACE/ID) which is associated with cardiovascular pathology and nitric oxide activity, and is in strong linkage disequilibrium with functional variants. Following amplifications, samples were mixed with gel-dye and markers and loaded into commercially available microfluidic chips designed for DNA sizing applications. In the study (N = 230), 95 (41%) of the DNA samples were homozygous and 135 (59%) were heterozygous for the iNOS5 repeats. For eNOS27, 173 (75%) of the genotyped DNA samples were homozygous for the larger 4b allele and the remaining 57 samples (25%) were heterozygous (4b/4a). No DNA samples were homozygous for the shorter 4a allele with four 27 bp repeats. In case of ACE/ID, 47 (20%) of the DNA samples were homozygous for the insertion, 65 (28%) were homozygous for the deletion and the remaining 118 (51%) were heterozygous. The results obtained were verified by analyzing random amplicons using bi-directional sequencing and GeneScan 3.0 analyses with 100% concordance being observed. Using the microfluidic chip-based method, separation and DNA sizing and genotyping are rapidly accomplished. The DNA fragments are resolved clearly and the system allows quantitation. Finally, the microfluidic chip-based method may be used for both large- and small-scale genotyping studies.

Alleles↗

A simple DNA disc chip in a microarray design based on modified comparative genomic hybridization for sperm DNA analysis.

OBJECTIVE: A DNA disc chip assay, based on comparative genomic hybridization, was designed to measure changes in sperm DNA intensities. The objective was to analyze the DNA integrity of hyperactive sperm cells after mild heat treatment. DESIGN: The assay based on a multiple cell comet assay was used to analyze changes in genomic DNA. Washed sperm DNA were tested on the assay and images stored in a microarray design. SETTING: Clinical and academic research environment. PATIENT(S): Frozen-thawed washed sperm from different donors (n = 7). INTERVENTION(S): Discarded sperm leftover from trial washes carried out at 37 degrees and 40 degrees C were frozen and processed for the DNA disc chip assay. MAIN OUTCOME MEASURE(S): Fluorescent intensities of DNA disc chips and sperm variables. RESULT(S): Heat treatment resulted in more than eightfold increase in sperm hyperactive motility with little degradation in DNA integrity. Sperm with low hyperactivation was associated with alterations in DNA after heat treatment. CONCLUSION(S): The DNA disc chip assay was simple, inexpensive, and permitted assisted reproduction technologies laboratories to use comparative genomic hybridization for cytogenotoxicity testing. However, the assay required manual processing, a fluorescent microscope, and computer. The data showed an association between sperm hyperactivation and DNA integrity suggesting that the hyperactivation marker may be used for selecting quality sperm for intracytoplasmic sperm injection. More studies are needed to examine temperature effects on ejaculated human sperm.

DNA↗

The ratio of prostate chips with cancer: a new measure of tumor extent and its relationship to grade and prognosis.

The ratio of chips with cancer to the total number of chips was studied in 118 patients with prostate cancer who underwent transurethral prostatectomy. We found that this ratio is a prognosticator closely associated to the stage of tumor (local or extensive) and to the chance of death from prostate cancer. Stage, the ratio of positive chips and the Gleason histologic score are all closely tied one to another, and it is unclear from this initial study whether these variables provide independent or additive prognostic information. Nevertheless, the ratio of positive chips shows far better interobserver agreement than does the Gleason score, and in patients with the most common predominant score of three, it can separate most of those with localized disease from most of those with extensive disease. Thus the ratio shows promise as a reliable predictor of stage of disease and of long-term failure, and hence it may help in the choice of patients for curative surgery.

Adenocarcinoma↗

Scratch hardness and chipping of dental ceramics under different environments.

OBJECTIVE: The goal of this program was to identify promising environments that could efficiently minimize machining-induced damage of dental materials. METHODS: Single point abrasion (SPA) scratch testing was used on five materials to determine the scratch hardness and amount of edge chipping as functions of chemical environment, including air, water, saline and glycerol solutions. Limited testing was also done under additional environments expected to promote chemomachining effects via crack growth promotion or debris removal. A conical diamond indenter and a conventional tungsten carbide machining tool were used in the scratch tests. One-way ANOVA analysis was used to determine statistical differences among the variables. RESULTS: There was a consistent trend across materials that the water and saline yielded the lowest values of scratch hardness, air the next lowest, and the tests performed in glycerol yielded the highest hardness values. The measured hardness values using the conical diamond tool in the glycerol environments were about twice the hardness values measured under water and saline solutions. Environmental effects on chipping were minimal, but a linear relationship between load and per cent chipping was determined for the WC tool within the 10-50 N test range. The choice of scratch tool strongly affected scratch hardness and chipping tendency. SIGNIFICANCE: The chemical environment had an effect on machining characteristics, but the effects were more dependent on tool interactions rather than material specific properties. As a result, it may not be possible to utilize a particular single environment to substantially improve the damage response of dental materials to machining operations. Improvements in damage resistance can be environmentally obtained, but only for shallow cuts (finishing operations).

Air↗