Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ANKLE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

[The evolution of ankle arthroplasty].

The results of ankle arthroplasty have generally been disappointing compared to other forms of arthroplasty. The present survey of results of ankle arthroplasty deals with the anatomical, the kinemasiological the biomechanical and the biological features of the ankle joint. These features all seem important prerequisites for a successful total ankle prosthesis design. From the study of the results displayed in the literature and those of my own series it can be stated that a modern ankle arthroplasty should respect the normal anatomy and kinemasiology. Biomechanically it should work as a normal ankle joint i. e. cylindrical mobility, congruency and a possibility for normal torque within the ankle mortise. The prosthesis components should only be fixed in solid subchondral bone, and preferably without cement. Only compressible forces should act at the bone-prosthesis interface. The axis of the ankle joint as well as of that of the hindfoot should be aligned to normal. Meticulous surgery and special guide instruments are absolute necessities. Restoration of muscle power and gait postoperatively are essential for a good and lasting result. The indication for ankle arthroplasty is mainly cases of osteoarthritis (primary or traumatic) and rheumatoid arthritis. Contraindications are talus necrosis, Charcot joints, extreme osteoporosis, severe arteriosclerosis, and very aggressive arthritis. Mental disorders and neurological disorders may also be contraindications. Furthermore, the patients should agree not to perform sports involving jumping and running or other ankle demanding activities. The average annual failure rate should not exceed 1 % if these recommendations are followed.

Ankle Joint↗

[Prosthetic replacement of the upper ankle joint].

Results after total ankle arthroplasty in the 1970s and 1980s were poor. The outcomes of these surgeries deteriorated rather dramatically with time. Causes of failure were multifactorial, but the two main reasons for failure were constrained designs and cement fixation. Today, the design of total ankle arthroplasty is unconstrained and the fixation is uncemented. Total ankle arthroplasties are considered technically demanding procedures, with relatively high early postoperative complication rates. As yet, the ideal total ankle patient remains to be defined. Good alignment and ligamentous stability are essential. Osteonecrosis and profound osteoporosis are associated with poor results due to problems with bony fixation. Patients should be advised that the implant may fail and that this may require further surgery, including the potential need for an ankle fusion. The results of ankle fusions, although usually initially good, seem to deteriorate with time. Not uncommonly, patients frequently develop peritarsal degenerative joint disease several years after an ankle arthrodesis. Because of the associated pain and functional limitations that can follow ankle fusion, efforts to develop a workable total ankle replacement continue. At present, the long-term results of new designs are unknown. Today, total ankle arthroplasty should be limited to centers where patient volume and infrastructure allows critical review and prospective clinical trials to determine the factors leading to successful and unsuccessful outcomes.

Ankle Joint↗

[The HINTEGRA ankle: short- and mid-term results].

The HINTEGRA ankle was developed as an attempt to specifically address the needs of minimal bone resection, extended bone support, proper ligament balancing, and minimal contact stresses within and around the prosthesis. The purpose of this article was to present the design and rationale of this prosthesis, and to analyze the clinical and radiological short- to mid-term results particularly with respect to the revisions and learning curve. Of the 278 total ankle replacements (between 2000 and 2004) with the HINTEGRA ankle, 271 ankles [patients: 261, males: 133, females: 128, age: 58.4 years (range: 25-90 years)] were clinically and radiographically assessed after 36.1 months (range: 12-64 months). The preoperative diagnosis was post-traumatic osteoarthrosis in 206 cases (76.0%), systemic arthritis in 34 cases (12.5%), and a primary osteoarthrosis in 31 cases (11.5%). Beside 4 perioperative and 19 early postoperative complications, a late complication occurred in 40 cases (14.8%). Of these, 22 complications (8.2%) were not related to implants, and 18 complications (6.6%) were related to implants. In all, 39 cases (14.4%) were revised; of these, 5 cases (1.8%) were revised to ankle arthrodesis. All other 34 revision arthroplasties were successful and did not evidence any differences in the outcome to the non-revised ankles. The AOFAS hindfoot score improved from 40.3 (range: 14-61) to 85.0 (range: 44-100) points at last follow-up. Radiographically, the tibial component was stable in all remaining 266 ankles, and no tilting of the component occurred since surgery. The talar component was positioned too posteriorly in 12 ankles (4.4%). The concept of minimal bone resection and wide bony support was shown to be successful on the tibial and talar sides. Most complications occurred in the early cases of this series, and the learning curve was found to be short and steep. Despite the high amount of post-traumatic cases with limited soft tissue quality, the obtained function, pain relief, and patient satisfaction were promising and, compared with other devices, the results mostly were superior. This may support the belief that anatomically shaped surfaces, as is the case in the HINTEGRA ankle, may advance success in total ankle replacement.

Adult↗

[The TNK ankle: short- and mid-term results].

Total ankle replacement has been introduced in the last 30 years. The TNK ankle is build from ceramics, and it was continuously improved. This prosthesis has the longest fellow-up times. Seventy ankle prostheses of the newest generation has been implanted between 1991 and 2001. Of these, 67 prostheses were assessed clinically and radiographically after 62 months (range, 24 to 132 months). Three ankles have been revised. The clinical score improved for the patients with primary or posttraumatic arthritis from 34 to 86, and for the patients with rheumatoid arthritis from 45 to 74. Loosening was found in 4 ankles with non-rheumatoid arthritis, and in 17 ankles with rheumatoid ankles. Total ankle replacement has emerged to a valuable alternative to ankle arthrodesis, and satisfactory results have been achieved with the current implants. The bone-implant interphase might play a most important factor for success. There is evidence that the biologic advantages of ceramics may help to improve long-lasting success in total ankle replacement.

Adult↗

Physiological coxa varus-genu valgus influences internal knee and ankle joint moments in females during crossover cutting.

This study evaluated the ankle and knee electromyographic, kinematic, and kinetic differences of 20 nonimpaired females with either neutral (group 1) or coxa varus-genu valgus (group 2) alignment during crossover cutting stance phase. Two-way mixed model ANOVA (group, session) assessed mean differences ( p<0.05) and correlation analysis further delineated relationships. During impact absorption, group 2 displayed earlier peak horizontal braking (anterior-posterior) ground reaction force timing, decreased and earlier peak internal knee extension moments (eccentric function), and earlier peak internal ankle dorsiflexion moment timing (eccentric function). During the pivot phase, group 2 displayed later and eccentrically-biased peak ankle plantar flexion moments, increased peak internal knee flexion moments (eccentric function), and later peak knee internal rotation timing. Correlation analysis revealed that during impact absorption, subjects with coxa varus-genu valgus alignment (group 2) displayed a stronger relationship between knee internal rotation velocity and peak internal ankle dorsiflexion moment onset timing ( r= -0.64 vs r = -0.26) and between peak horizontal braking ground reaction forces and peak internal ankle dorsiflexion moment onset timing ( r= 0.61 vs r= 0.24). During the pivot phase these subjects displayed a stronger relationship between peak horizontal braking ground reaction forces and peak internal ankle plantar flexion moment onset timing ( r= -0.63 vs r= -0.09) and between peak horizontal braking forces and peak internal ankle plantar flexion moments ( r= -0.72 vs r= -0.26). Group differences suggest that subjects with coxa varus-genu valgus frontal-plane alignment have an increased dependence on both ankle dorsiflexor and plantar flexor muscle group function during crossover cutting. Greater dependence on ankle muscle group function during the performance of a task that requires considerable 3D dynamic knee joint control suggests a greater need for frontal and transverse plane weight bearing tasks that facilitate eccentric ankle muscle group function to optimize injury prevention conditioning and post-surgical rehabilitation programs.

Adolescent↗

Arthrodesis for failed ankle arthroplasty.

Thirty-eight ankles in 36 patients who underwent fusion for failed total ankle arthroplasty were reviewed. Twenty-two patients were women and 14 were men, and their mean age was 56.8 years. The fusion methods performed in the 38 ankles were malleolar resection in 13, intercalated bone graft in 20, and posterior tibiotalocalcaneal fusion in 5. Fixation was external in 36 ankles and internal in 2. Bone graft was used in 32 ankles. Union was achieved in 33 ankles (89%). The average duration of the follow-up period in 29 patients (31 ankles) was 8.3 years (range, 2-14.4 years). Patients had no or mild pain in 24 ankles (80%). Complications occurred in five ankles (13%). Failed total ankle arthroplasty may be successfully salvaged by arthrodesis.

Adult↗

The effect of foot and ankle prosthetic components on braking and propulsive impulses during transtibial amputee gait.

OBJECTIVE: To assess the influence of energy storage and return (ESAR) prosthetic feet and multi-axis ankles on ground reaction forces and loading asymmetry between lower limbs in transtibial amputees. DESIGN: Subjects wore 2 different prosthetic feet with and without a multi-axis ankle and were analyzed using a blind repeated-measures multivariate analysis-of-variance design. SETTING: Gait analysis laboratory. PARTICIPANTS: Fifteen healthy unilateral transtibial amputees (>55 y) who had an amputation at least 1 year before testing because of vascular disorders. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The anteroposterior ground reaction force impulse, peak ground reaction forces, and braking and propulsion impulse duration were analyzed as subjects walked at a self-selected speed while wearing each of the 4 foot-ankle prosthesis combinations. Statistical analyses were used to determine if there was a significant foot, ankle, or foot-ankle interaction effect on the outcome measures for each foot (P<.05). RESULTS: Amputees generated a significantly greater propulsive impulse with the residual leg when wearing a multi-axis ankle with the ESAR and non-ESAR foot, which improved the propulsive symmetry between the residual and intact legs. There was no prosthetic foot effect on these measures. There were no significant differences in the peak residual-leg braking or propulsive ground reaction forces or the impulse durations due to the prosthetic foot, ankle, or foot-ankle interactions, although an increase in the propulsive impulse duration approached significance (P=.062) with a multi-axis ankle. CONCLUSIONS: These results suggest that amputee gait may improve with the prescription of multi-axis ankles that allow for greater propulsive impulses by the residual leg, which improve the loading symmetry between legs.

Amputation, Surgical↗

Lateral ankle sprain: isokinetic test reliability and comparison between invertors and evertors.

OBJECTIVE: Evaluate reliability of isokinetic tests for inversion and eversion in individuals with recurrent lateral ankle sprain and compare inversion to eversion muscle performance in the same ankles. DESIGN: Reliability was evaluated by comparing the results of two ankle inversion/eversion isokinetic tests. Inversion and eversion were compared with the results presented by the tests. BACKGROUND: Previous studies showed reliable isokinetic tests for ankles with no sprain history. It is unknown if such tests can also be performed in lateral sprained ankles. It is unclear whether there is difference between invertors and evertors in these ankles. METHODS: Eleven men with recurrent ankle lateral sprain in one limb were tested using an isokinetic dynamometer. The tests consisted of 5 cycles of maximal contraction in 30 degrees /s and 120 degrees /s. Both injured and noninjured ankles were tested. Peak torque was recorded for analysis. RESULTS: The tests are reliable and intraclass coefficient correlation varied from 0.71 to 0.95. Invertors generated higher peak torques than evertors (P = 0.03) when injured ankles were tested at 120 degrees /s. CONCLUSIONS: Isokinetic inversion/eversion tests showed to be reliable. A decrease in peak torques can be seen during higher velocity tests. The only difference between invertors and evertors was seen when injured ankles were tested at 120 degrees /s. In this case invertors showed higher peak torques.

Adolescent↗

A comparison of gait with solid and hinged ankle-foot orthoses in children with spastic diplegic cerebral palsy.

This study compared the effects of solid and hinged ankle-foot orthoses (AFOs) on the gait of children with spastic diplegic cerebral palsy (CP) who ambulate with excessive ankle plantar flexion during stance. Twelve children with spastic diplegic CP wore no AFOs for an initial 2-week period, solid AFOs for 1 month, no AFOs for 2 weeks, and hinged AFOs for 1 month. Lower extremity muscle timing, knee and ankle joint motions, moments and powers, and temporal-distance characteristics were measured during ambulation for an initial barefoot baseline test, and with solid and hinged AFOs for the other two tests. Both orthoses increased stride length, reduced abnormal ankle plantar flexion during initial contact, midstance and terminal stance (TST), and increased ankle plantar flexor moments closer to normal during TST. Hinged AFOs increased ankle dorsiflexion at TST and increased ankle power generation during preswing (PSW) as compared to solid AFOs, and increased ankle dorsiflexion at loading compared to no AFOs. No other significant differences were found for the gait variables when comparing these orthoses. Either AFO could be used to reduce the excessive ankle plantar flexion without affecting the knee position during stance. The hinged AFO would be recommended to produce more normal dorsiflexion during TST and increased ankle power generation during PSW in children with spastic diplegic CP.

Adolescent↗

Preoperative gait characterization of patients with ankle arthrosis.

The purpose of this study was to evaluate the kinematic changes that occur about the foot and ankle during gait in patients with degenerative joint disease (DJD). By comparing a normal adult population with what was found in the DJD population we determined how the motion of theses groups differed, thereby characterizing how this pathology affects foot and ankle motion. A 15-camera Vicon Motion Analysis System was used in conjunction with weight bearing radiographs to obtain three-dimensional motion of the foot and ankle during ambulation. The study was comprised of 34 patients and 35 ankles diagnosed with DJD (19 men and 15 women) of the ankle and 25 patients with normal ankles (13 men and 12 women). Dynamic foot and ankle motion was analyzed using the four-segment Milwaukee Foot Model (MFM). The data from this model resulted in three-dimensional (3D) kinematic parameters in the sagittal, coronal, and transverse planes as well as spatial-temporal parameters. Patient health status was evaluated using the SF-36 Health Survey and American Orthopaedics Foot and Ankle Society (AOFAS) hindfoot scores. The DJD group showed significant differences (p<0.001) as compared to normals with prolonged stance time, shortened stride length, reduced cadence and a walking speed which was only 66.96% of normal. Overall, kinematic data in the DJD cohort showed significant differences (p<0.001) in all planes of motion for tibial, hindfoot and forefoot motion as compared to normals. The average preoperative AOFAS hindfoot score was 26. DJD of the ankle results in decreased range of motion during gait. This decreased range of motion may be related to several factors including bony deformity, muscle weakness, and attempts to decrease the pain associated with weight bearing. To date there has not been a study which describes the effect of this disease process on motion of the foot and ankle. These findings may prove to be useful in the pre-operative assessment of these patients.

Adult↗

Ankle ROM and stiffness measured at rest and during gait in individuals with and without diabetic sensory neuropathy.

INTRODUCTION: The purpose of our study was to examine the relationship between ankle dorsiflexion (DF) range of motion (ROM) and stiffness measured at rest (passively) and plantar loading during gait in individuals with and without diabetes mellitus (DM) and sensory neuropathy. Specifically, we sought to address three questions for this at-risk patient population: (1) Does peak passive DF ROM predict ankle DF ROM used during gait? (2) Does passive ankle stiffness predict ankle stiffness used during gait? (3) Are any of the passive or gait-related ankle measures associated with plantar loading? METHODS: Ten subjects with DM and 10 age and gender matched non-diabetic control subjects participated in this study. Passive ankle DF ROM and stiffness were measured with the Iowa Ankle ROM device. Kinematic, kinetic and plantar pressure data were collected as subjects walked at 0.89 m/s. RESULTS: We found that subjects with DM have reduced passive ankle DF ROM and increased stiffness compared to non-diabetic control subjects, however, subjects with DM demonstrated ankle motion, stiffness and plantar pressures, similar to control subjects, while walking at the identical speed, 0.89 m/s (2 mph). These data indicate that clinical measures of heel cord tightness and stiffness do not represent ankle motion or stiffness utilized during gait. Our findings suggest that subjects with DM utilize strategies such as shortening their stride length and reducing their push-off power to modulate plantar loading.

Ankle Joint↗

Relationship between ankle position and pelvic floor muscle activity in female stress urinary incontinence.

OBJECTIVES: To assess the influence of ankle position on pelvic floor muscle (PFM) activity in women with stress urinary incontinence. METHODS: A total of 39 women, ranging in age from 38 to 72 years and clinically diagnosed with stress urinary incontinence, participated in testing of PFM activity changes during various pelvic tilt angles created by horizontal, dorsiflexed, and plantar flexed ankle positions. PFM activity was measured by an intravaginal probe with surface electromyographic electrodes. An adjustable angle platform was used to set the ankle in each of the positions to create the various pelvic tilt postures. RESULTS: Significant differences were found in resting PFM activity between horizontal standing with the ankle in the neutral position and standing with the ankle in plantar flexion (P = 0.01). Patients with ankle dorsiflexion also had greater resting PFM activity than with ankle plantar flexion (P < 0.01). Subjects showed significant changes in mean maximal PFM activity when standing with the ankle dorsiflexed and horizontal or in plantar flexion. CONCLUSIONS: A standing posture that includes various ankle positions effectively facilitates PFM activity through enhanced pelvic tilt. We recommend these ankle positions as an adjunctive option combined with PFM training for stress urinary incontinence.

Adult↗

Utility of automated brachial ankle pulse wave velocity measurements in hypertensive patients.

BACKGROUND: We examined whether pulse wave velocity (PWV), determined by brachial ankle arterial pressure wave measurements, using a newly developed, fully automated device could be a surrogate measure for carotid femoral PWV. METHODS & RESULTS: This device (AT-form PWV/ABI, Nippon Colin, Komaki, Japan) can simultaneously monitor bilateral brachial and ankle pressure wave forms using the volume plethysmographic method, with two optional tonometry sensors for carotid and femoral arterial wave measurements. We examined the right brachial-right ankle PWV and left carotid-left femoral PWV in 89 normotensive and untreated hypertensive patients. The brachial ankle PWV correlated well with carotid femoral PWV (r = 0.755, P <.00001). The Bland-Altman plots of the two variables, however, showed a significant difference exists between the two techniques over the range of measurement. The within-observer and between-observer coefficients of variation of the brachial ankle PWV were 6.5% +/- 4.1% and 3.6% +/- 3.9%, respectively. To determine the factors affecting brachial ankle PWV, we studied treated and untreated hypertensive patients with World Health Organization stage I (n = 146), stage II (n = 74), or stage III (n = 54). In multiple regression analysis, age, brachial ankle PWV, and the presence of diabetes were significant predictors of the severity of hypertensive organ damage. Age, systolic blood pressure, and the stage of hypertensive organ damage were major determinants of brachial ankle PWV. CONCLUSIONS: Although the brachial ankle PWV does not agree with the carotid femoral PWV, this parameter may yet become a new, useful measure for arterial stiffness. Further longitudinal studies are necessary to confirm the clinical significance of the brachial ankle PWV.

Aged↗

The effect of ankle joint position and effort on quadriceps reflex sensitivity.

OBJECTIVE: To investigate a possible ankle-knee synergy, experiments with normal subjects were performed to compare changes of the quadriceps motor pool excitability due to ankle position and effort. METHODS: Vastus medialis H reflex amplitude was examined during ankle isometric contractions conditioned by different ankle positions (dorsiflexion, neutral, and plantarfiexion) with or without voluntary effort (either in the dorsiflexion or plantarflexion direction). Repeated measures ANOVAs were performed on the mean and standard deviation of the H peak-to-peak amplitude. RESULTS: Mean vastus medialis H reflex amplitudes were significantly different among the trials of different ankle efforts (P<0.05), and significantly increased during plantarfiexion efforts. In contrast, mean vastus medialis H reflex amplitude did not vary with respect to changes of ankle position (P>0.05). CONCLUSIONS: The data suggest that (1) the position of the ankle joint did not significantly modify the excitability of the neuromotor pool of the VM muscle, in either static or active cases, and (2) the effort effect from the ankle joint on the VM neuromotor pool is most significant during ankle plantarfiexion effort. Possible mechanisms are central motor irradiation and peripheral force-dependent pathways from the ankle joint that influence the VM neuromotor pool.

Adult↗

Effect on spasticity after performance of dynamic-repeated-passive ankle joint motion exercise in chronic stroke patients.

Spasticity associated with abnormal muscle tone is a common motor disorder following stroke, and the spastic ankle may affect ambulatory function. The purpose of this study was to investigate the short-term effect of dynamic-repeated-passive ankle movements with weight loading on ambulatory function and spastic hypertonia of chronic stroke patients. In this study, 12 chronic stroke patients with ankle spasticity and inefficient ambulatory ability were enrolled. Stretching of the plantar-flexors of the ankle in the standing position for 15 minutes was performed passively by a constant-speed and electrically powered device. The following evaluations were done before and immediately after the dynamic-repeated-passive ankle movements. Spastic hypertonia was assessed by the Modified Ashworth Scale (MAS; range, 0-4), Achilles tendon reflexes test (DTR; range, 0-4), and ankle clonus (range, 0-5). Improvement in ambulatory ability was determined by the timed up-and-go test (TUG), the 10-minute walking test, and cadence (steps/minute). In addition, subjective experience of the influence of ankle spasticity on ambulation was scored by visual analog scale (VAS). Subjective satisfaction with the therapeutic effect of spasticity reduction was evaluated by a five-point questionnaire (1 = very poor, 2 = poor, 3 = acceptable, 4 = good, 5 = very good). By comparison of the results before and after intervention, these 12 chronic stroke patients presented significant reduction in MAS and VAS for ankle spasticity, the time for TUG and 10-minute walking speed (p < 0.01). The cadence also increased significantly (p < 0.05). In addition, subjective satisfaction with the short-term therapeutic effect was mainly good (ranging from acceptable to very good). In conclusion, 15 minutes of dynamic-repeated-passive ankle joint motion exercise with weight loading in the standing position by this simple constant-speed machine is effective in reducing ankle spasticity and improving ambulatory ability.

Adult↗

Comparison of two intervention programmes in young female players in European handball--with and without ankle disc.

INTRODUCTION: The prevention of injuries in all sports calls for a structured plan. The plan consists, as earlier described, of four steps. We have previously presented studies incorporating all four steps. The studies have shown that it is possible to prevent most injuries in young female players in European handball by applying a training programme combining the use of an ankle disc with functional strength training. In the previous studies we were not able to discriminate whether the preventive effect was due to the functional strength training or the training with the ankle disc. The aim of this study was to compare a programme with ankle disc and functional strength training with a programme with functional strength training only. METHODS: Twenty handball teams were asked to participate, and 16 of 20 handball teams agreed to participate. The teams were cluster randomised to either the programme with or without an ankle disc. RESULTS: The group using the programme without the ankle disc had a significantly higher number of traumatic injuries (16 vs. 6). The incidences of traumatic injuries in the ankle disc group were 2.4 (95% CI 0.7; 6.2) injuries per 1000 h of match and 0.2 (95% CI 0.02; 0.7) injuries per 1000 h of practice. In the group without ankle disc the incidences were 6.9 (95% CI 3.3; 12.7) injuries per 1000 h of match and 0.6 (95% CI 0.2; 1.3) injuries per 1000 h of practice. A significantly higher multivariate odds ratio (4.8) was found in the group not using the ankle disc. In addition the group using the ankle disc had significantly fewer moderate and major injuries. CONCLUSION: By adding ankle disc training to a training programme with functional strength training, it is possible to reduce the number of injuries significantly, especially the number of moderate and major injuries.

Adolescent↗

Kinesthetic awareness in subjects with multiple ankle sprains.

The purposes of this study were 1) to determine whether decreased kinesthetic awareness occurs in individuals with recurrent ankle sprains and 2) to determine whether the one-legged standing balance test can be used to differentiate between ankle instability in injured and uninjured ankles. Thirty athletes between 18 and 24 years of age with multiple sprains of one ankle and no reported sprains of the other ankle were tested to compare their ability to detect passive plantar flexion and standing balance in each ankle. Luce's choice theory was used to analyze subjects' responses. Subjects had significantly greater difficulty detecting passive motion in the ankle with sprains as compared with the uninjured ankle. Subjects also performed a one-legged standing balance test on both the injured and uninjured legs. In 20 subjects, either the subject or observer reported balance deficits on the injured side as compared with the uninjured side. The results of this study demonstrate the need for clinicians to evaluate kinesthetic deficits and to design exercise programs to improve kinesthetic awareness and decrease ankle instability in individuals with multiple ankle sprains.

Adolescent↗

Total ankle replacement in patients with rheumatoid arthritis.

Patients with rheumatoid arthritis commonly experience involvement of the ankle and hindfoot. Severe pain and functional limitations may develop as a result of tibiotalar arthritis, requiring surgical treatment. The advantages of total ankle arthroplasty over ankle arthrodesis include preservation of motion and decreased stresses on the midfoot and subtalar joints. Previous experience with early design ankle replacements revealed high complication rates and as much as 75% of component loosening. Modern ankle implants have been designed to achieve uncemented fixation with less articular constraint. Patients with rheumatoid arthritis who had total ankle replacement using two different types of second-generation ankle implants were examined clinically and radiographically. The average postoperative American Orthopaedic Foot and Ankle Society ankle-hindfoot score was 81 of a possible 100, at a mean of 6.4 years after surgery. Radiographically, 88.5% of implants were stable without evidence of subsidence at a mean of 6.3 years. Three tibial components had subsided at an average of 7 years. There was evidence of tibial osteolysis with the Buechel Pappas Low Contact Stress implant in 11.5% of patients. Total ankle replacement in patients with rheumatoid arthritis, using a second-generation prosthesis, can provide reliable relief of pain and good functional results at intermediate-term followup, although the incidence of osteolysis warrants close followup.

Adolescent↗