Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sample pretreatment”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Differential effects on the cyanogenic glycoside content of fermenting cassava root pulp by beta-glucosidase and microbial activities.

The degradation of cyanogenic glycosides was studied in spontaneously fermenting cassava root pulp and in fresh pulp samples pretreated to prevent either endogenous beta-glycosidase activity, fermentation, or both. The rate of disappearance of the glycosides, as measured by hydrocyanic acid (HCN) production in situ, in membrane-sterilised media or in samples containing 1% sodium iodoacetate, was comparable with the untreated control in which 85% of the substrate was broken down within 72 h. Pretreatment of the fresh pulp with the beta-glucosidase inhibitor 1,5-gluconolactone (1%) markedly reduced the rate of disappearance of the cyanogens while inclusion of glucose in this test medium at the 3% level appeared to induce some hydrolysis. Loss of bound (glycosidic) cyanide in sterilised medium containing the glucosidase inhibitor was negligible. The results suggest that the contribution of the fermentation process in cyanide detoxification of pulped cassava roots is minimal.

Cyanides↗

Ultrasound-assisted solubilization of trace and minor metals from plant tissue using ethylenediaminetetraacetic acid in alkaline medium.

A simplified and fast sample pretreatment method based on ultrasound-assisted solubilization of metals from plant tissue with ethylenediaminetetraacetic acid in alkaline medium is described. Powdered unknown and certified plant samples (particle size < 50 microns) were slurried in the solubilization medium and subjected to high intensity ultrasonication by a probe ultrasonic processor (20 kHz, 100 W). Metal solubilization can be accomplished within 3 min using a 30% vibrational amplitude and 0.1 M EDTA at pH 10, the supernatant obtained upon centrifugation being used for analysis. The method is applied to several food plants with unknown metal contents and certified plant samples such as CRM GBW07605 tea leaves, BCR CRM 61 aquatic moss and BCR CRM 482 lichen, with good trueness and precision. Intensive treatments with concentrated acids involving total matrix decomposition can be avoided. Metal determination (Ca, Cd, Mg, Mn, Pb and Zn) in the alkaline extracts was carried out by flame and electrothermal atomic absorption spectrometry.

Bryopsida↗

Analysis of nitrate and nitrite in water and urine by capillary zone electrophoresis.

A capillary zone electrophoresis method for the separation and analysis of nitrate and nitrite in water and urine was developed. No interference in the electropherogram from other anions is observed by using a polyacrylamide-coated column with a modified phosphate buffer at pH 3 for the separation, and UV absorption at 214 nm for the detection. The method does not require sample pretreatment or the use of organic solvents. The limit of detection for each analyte (S/N = 3), using a 75 microns I.D. capillary, is 0.5 microgram/ml. Urine samples require 40-fold dilution in order to maintain migration time reproducibility to within 1% relative standard deviation.

Electrophoresis↗

Cyclooxygenase-2 impairs treatment effects of radiotherapy for cervical cancer by inhibition of radiation-induced apoptosis.

PURPOSE: Cyclooxygenase-2 (COX-2) plays a pivotal role in regulation of radiation-induced apoptosis. The aim of this study was to analyze the relationship between COX-2 expression and postradiotherapy outcomes of patients with cervical cancer. METHODS AND MATERIALS: Biopsy specimens from 47 consecutive patients who had undergone definitive radiotherapy alone or radiotherapy combined with chemotherapy between October 2002 and November 2004 were investigated. RESULTS: The COX-2 expression rate of the pretreatment samples was 46.1% +/- 21.0%, and the apoptotic index (AI) 1 week after start of radiotherapy was 2.1% +/- 0.9%. There was a significant negative correlation between the pretreatment COX-2 expression and the AI during radiotherapy (r = -0.52, p = 0.0002). Complete response rates were 59% for COX-2-positive patients compared with 80% for COX-2-negative patients (p = 0.12). The 2-year local control rate for COX-2-positive patients was 71.3%, whereas the corresponding rate for COX-2-negative patients was 96.0% (p = 0.06). CONCLUSIONS: To the best of our knowledge, this is the first report to prove clinically that COX-2 can make cervical squamous cell carcinomas more refractory to radiotherapy by inhibition of radiation-induced apoptosis. Furthermore, expression of COX-2 may be a good indicator to predict local tumor control after radiotherapy. Although long-term results are ultimately needed, the combination therapy of radiotherapy with use of a COX-2 inhibitor could yield improved outcomes for patients with COX-2 expressing cervical cancer.

Adult↗

Miniaturized sample preparation combined with liquid phase separations.

Miniaturized sample preparation methods designed as the sample pretreatment for liquid phase separations, such as liquid chromatography, capillary electrophoresis and capillary electrochromatography, have been reviewed especially for the on-line coupling of the sample preparation process and the separation process. The development of the desorption interfaces for the effective combining of the sample preparation and subsequent liquid phase separations is briefly described along with the applications of the combined analytical systems to the analysis of complex sample mixtures such as biological and environmental matrices. Novel use of fine polymeric filaments as the extraction medium for microscale liquid phase separation methods are investigated and a comparison is made with other sample preparation techniques. Polymer coating onto the fibrous material is also introduced to further develop microscale sample preparation methods with improved extraction performance. Several other microscale sample preparation methods having a potential compatibility to the liquid phase separations are also described for future applications of these techniques.

Chromatography, Liquid↗

Application of a semipermeable surface column for the determination of amoxicillin in human blood serum.

A high-performance liquid chromatography column-switching system for the automated determination of amoxicillin in human serum was developed as a more efficient alternative for the already existing systems with off-line sample pretreatment. The column-switching system consists of a semipermeable surface (SPS) column and an analytical reversed-phase (RP) C18 column. After centrifuging, pure serum samples were injected into the column-switching system. Clean-up, with regard to removal of proteins, was performed on the SPS column. The fraction containing amoxicillin was concentrated on the analytical RP-C18 column. Finally, chromatography and detection were performed with the RP-C18 column using UV detection at 234 nm. The total analysis time was 15 min. The method has proven to be reliable and to be more time- and resource-efficient compared to previously used methods with off-line sample clean-up. It is now used in bioavailability studies for the development of new amoxicillin formulations.

Amoxicillin↗

Total protein determinations by particle beam/hollow cathode optical emission spectroscopy.

A novel method for quantitative total protein determinations is presented. Total protein content is determined by particle beam/hollow cathode optical emission spectroscopy (PB/HC-OES) through monitoring of carbon atomic emission. The PB/HC-OES offers such advantages as ease of operation, exclusion of labor-intensive sample pretreatment processes, rapid analysis, high sensitivity, and low detection limit. The method could also be adapted to be integrated to current microfluidics devices. Parametric optimization for sample introduction, nebulization, desolvation, and hollow cathode source conditions is performed for the analysis of aqueous bovine serum albumin solutions. Response curves of C (I) 193.0-nm emission were obtained under the optimized conditions with both 10% HCl and 100 micromL KCl added to the sample matrix as potential carriers. The detection limit for triplicate injections of bovine serum albumin standards was found to be on the single-nanogram level with 200-microL injections. The addition of KCl significantly improved the sensitivity, supporting the proposed "carrier effect" of chloride salts in the particle transport process. Results obtained here suggest a range of applications for the use of the PB/HC-OES source for total protein determinations; emphasis here is future use in assessing protein quantification in microfluidic systems.

Electrodes↗

Survey of inorganic arsenic in marine animals and marine certified reference materials by anion exchange high-performance liquid chromatography-inductively coupled plasma mass spectrometry.

A method for the determination of inorganic arsenic in seafood samples using high-performance liquid chromatography-inductively coupled plasma mass spectrometry is described. The principle of the method relied on microwave-assisted alkaline dissolution of the sample, which at the same time oxidized arsenite [As(III)] to arsenate [As(V)], whereby inorganic arsenic could be determined as the single species As(V). Anion exchange chromatography using isocratic elution with aqueous ammonium carbonate as the mobile phase was used for the separation of As(V) from other coextracted organoarsenic compounds, including arsenobetaine. The stability of organoarsenic compounds during the sample pretreatment was investigated, and no degradation/conversion to inorganic arsenic was detected. The method was employed for the determination of inorganic arsenic in a variety of seafood samples including fish, crustaceans, bivalves, and marine mammals as well as a range of marine certified reference materials, and the results were compared to values published in the literature. For fish and marine mammals, the results were in most cases below the limit of detection. For other sample types, inorganic arsenic concentrations up to 0.060 mg kg(-)(1) were found. In all samples, the inorganic arsenic content constituted less than 1% of the total arsenic content.

Animals↗

Determination of S-phenylmercapturic acid by GC-MS and ELISA: a comparison of the two methods.

S-phenylmercapturic acid (PMA) is a specific urinary biomarker of benzene at exposure levels lower than 1 ppm. However, measuring PMA in urine is an expensive task by either GC or HPLC due to the necessity of extensive sample pretreatment. In the present study, a commercial chemiluminescence enzyme-linked immunosorbent assay (ELISA) test for PMA and GC-MS were used for screening urine samples of 60 workers employed in petrochemical settings. The ELISA results were evaluated by comparison with the GC-MS. Overall, the ELISA test proved sensitive (limit of detection=0.1 microg l(-1)), rapid, robust and reliable, affording results in good agreement with the GC-MS (54% of measurements) and no false-negatives. On the other hand, 46% of the ELISA assays were assigned as false-positives (arbitrarily established when ELISA >5 microg l(-1), GC-MS <5 microg l(-1) and a correlation coefficient of 0.687 was calculated between the two methods. It appears that urinary PMA routine biomonitoring on large numbers of samples is carried out in a cost-effective and rapid approach by preliminary screening with the ELISA assay followed by GC-MS confirmation of concentrations exceeding the biological exposure index for PMA.

Acetylcysteine↗

Acid-labile subunit of human insulin-like growth factor-binding protein complex: measurement, molecular, and clinical evaluation.

Although the acid-labile subunit (ALS) of the approximately 150-kDa insulin-like growth factor (IGF)-binding protein (IGFBP) complex was described over a decade ago, details of ALS physiology have remained largely uncertain. We evaluated antibodies to synthetic human ALS and constructed a noncompetitive ALS enzyme-linked immunosorbent assay. Whereas uncomplexed ALS is directly measured, determination of total levels required sample pretreatment with SDS, which was found to optimally dissociate complexed ALS and significantly enhance ALS immunoreactivity. ALS in random adult sera was approximately 50% uncomplexed, and samples devoid of complexed ALS by immunoaffinity separation contained about 54% of the total levels. Serum ALS fractionated by gel filtration high performance liquid chromatography eluted in a single peak at approximately 150 kDa with IGF-I and IGFBP-3, but appeared at about 400-500 kDa after sample acidification and fractionation under acidic condition. The unexpected shift in ALS immunoreactivity remained unchanged when acid-neutralized or SDS-treated samples were fractionated under neutral pH and was reproducible when the 150-kDa complex was isolated, treated with acid or SDS, and rechromatographed. ALS in adult sera more tightly correlated with IGFBP-3 than IGF-I or IGF-II. The total levels (mean +/- SD) were 16.7 +/- 3.7 mg/L in 22 normal subjects, 28.3 +/- 8.1 mg/L in 20 acromegalic patients, and 9.5 +/- 3.8 in 32 GH-deficient adults. Little or no ALS was detectable in amniotic fluid, cerebrospinal fluid, seminal plasma, or milk, whereas high levels were present in synovial fluid. The development of ALS enzyme-linked immunosorbent assay should greatly facilitate further investigations of this unique glycoprotein.

Acromegaly↗

Artificial receptors in serologic tests for the early diagnosis of dengue virus infection.

BACKGROUND: Because of the range and nonspecificity of clinical presentations of dengue virus infections, we felt there was a need to create diagnostic tests. We used artificial receptors for the virus to develop serologic assays to detect dengue virus infection. METHODS: We coated a quartz crystal microbalance (QCM) with molecularly imprinted polymers specific for nonstructural protein 1 of flavivirus. These artificial receptors were specifically created on a QCM chip by polymerization of monomers and were cross-linked in the presence of the epitope site of nonstructural protein 1. We tested serum samples from patients with confirmed cases of dengue reported to the Center for Disease Control in Taipei. Samples were diluted 100-fold; no other sample pretreatment was used. The QCM response was compared with results of monoclonal ELISA. RESULTS: QCM signals were >15 Hz in 18 of 21 (86%) of dengue samples and in 0 of 16 control samples. The correlation (r2) of the QCM response and the ELISA result was 0.73. Within-run and run-to-run imprecisions (CV) were 4%-28% and 10%-32%, respectively. CONCLUSIONS: The described assay offers a serologic technique for diagnosis of early viremia. The results illustrate the potential of well-organized polymers on the highly sensitive sensor system for diagnostic and biotechnological applications.

Antibodies, Monoclonal↗

[Detection of an immunoglobulin-like serum protein possessing a high affinity for collagen].

Fibronectin isolated from bovine serum by affinity chromatography on collagen-Sepharose was found to contain a great number of concomitant proteins. Polyacrylamide gel electrophoresis of experimental samples pretreated with beta-mercaptoethanol under denaturation conditions resulted in the polypeptide fractions with Mr of 25, 54 and 82 KD, while the non-treated samples contained only one protein of non-fibronectin type (Mr = = 180-190 KD). This protein was isolated from the total preparations of collagen-binding proteins by the procedures generally employed for the isolation of purified preparations of immunoglobulins G; this protein was also isolated from purified immunoglobulins G using affinity chromatography on collagen-Sepharose. In terms of its molecular weight, subunit composition and immunological and chromatographical behaviour this protein can be related to immunoglobulins. The immunoglobulin-like protein isolated together with fibronectin revealed an affinity for denatured collagen, but not for fibronectin or Sepharose. The content of immunoglobulin with an affinity for denatured collagen in the total fraction of immunoglobulins G is 0.3-0.5%.

Animals↗

High dose intravenous immunoglobulin does not affect complement-bacteria interactions.

Pooled IgG preparations for i.v. use (IVIg) have been shown to possess anticomplementary activity in autoimmune and systemic inflammatory diseases. Both in vitro and in vivo, IVIg is a preferential acceptor of activated C4 and C3, thus diverting complement activation from the target surface. We explored the effect of IVIg on complement-bacteria interactions in an attempt both to determine the safety of IVIg preparations in relation to natural immunity to bacteria and to extend our knowledge of the physiologic mechanism of action of IVIg. Using both complement-sensitive and complement-resistant bacterial strains, we investigated the effect of IVIg on C3 binding to bacterial surfaces. In all cases, whether complement could be directly activated by bacteria through the classical or the alternative pathway, IVIg had no effect on the amount of C3 bound to bacteria. In addition, IVIg did not inhibit complement-dependent bacterial lysis. Interestingly, increasing concentrations of IVIg induced an increase in C1q binding, suggesting the presence of low affinity complement-fixing antibacterial Abs in certain preparations. Using serum samples from patients treated with IVIg, complement binding to and lysis of complement-sensitive bacterial strains were not modified as compared with normal controls and pretreatment samples, although a decrease in C3 binding to sensitized human erythrocytes was observed. Our data suggest that IVIg does not affect direct complement-bacteria interactions, although it is a potent agent to use for diversion of complement activation on sensitized target surfaces.

Animals↗

[Technical note: proposal of a routine method of accurate measurement of urinary trans,trans-muconic acid].

A method for routine measurement of urinary trans,trans-muconic acid. A method is proposed which allows the accurate determination of urinary trans,trans-muconic acid (Ma) by HPLC with UV detection. Sample pretreatment consists of a first purification on strong anionic exchange (SAX) cartridges followed by extraction on "end capped" reversed-phase (C18-EC) ones. Purified samples are directly injected onto a chromatographic column (C18, 150 x 4.6 mm I.D., 3 microns) which is eluted with water: methanol: acetic acid (97:2:1, v/v) mixture followed by a "spike" of acetonitrile. The retention time of MA is 15 min, the coefficient of variation is lower than 3%, the limit of detection is 7 micrograms/l. The method seems suitable for accurate biological monitoring of subjects exposed to benzene.

Chromatography, High Pressure Liquid↗

Application of an enzyme-linked immunosorbent assay for the analysis of paraquat in human-exposure samples.

Paraquat is a toxic quaternary ammonium compound used as an herbicide around the world. Easy, fast, and inexpensive but sensitive methods are needed to study the effects of long-term, low-level exposure of paraquat on human health. An enzyme-linked immunosorbent assay (ELISA) was used for quantification of paraquat in urine and air-filter samples collected in a human-exposure study among farm workers in Costa Rica. A sample pretreatment consisted of removal of interfering substances using solid-phase extraction resin columns. The precision and accuracy of the method were tested using duplicate spiked urine samples. The correlation between results for blind samples obtained using ELISA and liquid chromatography-mass spectrometry was significant (R2 = 0.945 and 0.906 for spiked and field samples, respectively). With an LOQ of 2 ng mL(-1), this ELISA method was able to distinguish the exposed from the nonexposed farm workers. For the air-filter analysis, paraquat was extracted by 9 M H2SO4 at 60 degrees C for 12 hours, and the results obtained by ELISA showed good correlation (R2 = 0.918) with the spectrophotometric (256 nm) measurements. Paraquat in acid-stabilized urine samples was very stable, and no significant losses were detected during a 3-month storage at room temperature, at 4 degrees C, or at -20 degrees C.

Air Pollutants↗

Liquid chromatographic determination of oxcarbazepine and its metabolites in plasma of epileptic patients after solid-phase extraction.

A method based on high-performance liquid chromatography with UV detection in combination with solid-phase extraction for sample pretreatment has been developed for the simultaneous analysis of the antiepileptic drug oxcarbazepine and its main metabolites in human plasma. The extraction of the analytes from plasma samples was carried out by means of a selective solid-phase extraction procedure using hydrophilic-lipophilic balance cartridges. The separation was obtained on a reversed-phase column (C(18), 150x4.6 mm I.D., 5 micrometer) using a phosphate buffer-acetonitrile-methanol-triethylamine mixture (final apparent pH* 3.5) as the mobile phase. Under these chromatographic conditions, oxcarbazepine and its metabolites 10,11-dihydro-10-hydroxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine and the internal standard are baseline separated in less than 9 min. The extraction yield values were >94% for all analytes and the precision, expressed by the RSD%, was in the low percentage range. For the entire method, including sample pre-treatment and HPLC determination, the linearity of the calibration lines, expressed by the linear correlation coefficient, was better than 0.995; the limit of quantitation was 15 ng ml(-1). The method was applied to plasma samples from patients undergoing chronic treatment with oxcarbazepine, both in monotherapy and in polytherapy. Based on the analytical parameters precision, accuracy, limit of quantitation and analysis time the method is suitable for routine application in therapeutic drug monitoring.

Anticonvulsants↗

Comparison study of two procedures for the determination of emamectin benzoate in medicated fish feed.

A new method has been developed for the determination of emamectin benzoate in fish feed. The method uses a wet extraction, cleanup by solid-phase extraction, and quantitation and separation by liquid chromatography (LC). In this paper, we compare the performance of this method with that of a previously reported LC assay for the determination of emamectin benzoate in fish feed. Although similar to the previous method, the new procedure uses a different sample pretreatment, wet extraction, and quantitation method. The performance of the new method was compared with that of the previously reported method by analyses of 22 medicated feed samples from various commercial sources. A comparison of the results presented here reveals slightly lower assay values obtained with the new method. Although a paired sample t-test indicates the difference in results is significant, this difference is within the method precision of either procedure.

Animal Feed↗

Electrospray ionization mass spectrometric studies on the amphoteric surfactant cocamidopropylbetaine.

After liquid chromatographic (LC) separation, electrospray ionization mass spectrometry (ESI-MS) was investigated for the determination of the amphoteric surfactant cocamidopropylbetaine (CAPB). In the positive ion mode the molecule formed the adduct ions [M + H](+), [M + Na](+) and [M + K](+). Adducts of these cations were also detected with decreasing abundance as dimer and trimer clusters. Additionally, doubly charged molecular ions with different combinations of cations were identified. It was noticed that the relative abundances of individual cation adducts were not reproducible, apparently owing to varying contents of alkali metal ions originating from the solvent and the sample. Under negative ionization, the major molecular ion was [M - H](-). Higher clusters formed by two and three surfactant molecules, i.e. [2M - H](-) and [3M - H](-) were likewise registered. The tendency to form clusters in both positive and negative ion modes, even at 0.1 mg l(-1) levels, was attributed to strong electrostatic interactions between the zwitterionic head groups. Further evidence for this assumption was provided by the detection of a fragment formed from [2M - H](-) which contained the two charged head groups. Studies were undertaken in the negative ion mode on the concentration- and orifice voltage-dependent monomer, dimer and trimer formation of C(12)-CAPB in order to evaluate potential issues in using the ion [M - H](-) mode for quantitative analysis. Finally, the established (-)-LC/ESI-MS method was applied to follow up the primary degradation of CAPB in a laboratory-scale fixed-bed bioreactor (FBBR) spiked with a test concentration of 10 mg l(-1). Direct analysis without sample pretreatment revealed that higher alkyl homologues were more prone to adsorption. Primary biodegradation of all alkyl homologues was completed after a period of 4 days. Selected lyophilized FBBR samples were examined for the presence of transient or stable degradation intermediates, but no metabolite could be identified.

Journal Article↗