Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy, Scanning Probe”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

The scanning near-field optical microscope as a tool for proteomics.

The identification of the entire genetic code of human DNA is more or less completed. With this knowledge, research in identifying the real information lying in the genes, will begin. This information is contained in the proteins, which are the main biological actors in the cell. For this reason proteins will be targeted in biological investigations in the future. The structure, affinity and reactivity of each identified protein has to be determined, which is a primary goal in the field of proteomics. This will require new and better strategies to identify protein-protein interaction. Our approach, based on the detection and visualization of single proteins by scanning near-field optical microscopy (SNOM), has allowed us to visualize various fixed and fluorochrome-labelled proteins at the nanometer scale. Subsequently SNOM may then be developed to efficiently detect the specific behavior of a certain protein in response to other biomolecules.

Bacterial Proteins↗

Differential scanning calorimetry and scanning thermal microscopy analysis of pharmaceutical materials.

Micro-thermal analysis (microTA) by scanning thermal microscopy is being used increasingly for the analysis of pharmaceutical dosage forms. However, there is currently little evidence to show that microTA data can compare directly with that from the established approach of differential scanning calorimetry (DSC). This work compares DSC and microTA data from an active vitamin B6 analogue, pyridoxal hydrochloride, and two commonly used pharmaceutical excipients, Mannitol and Avicel which are used in its formulation. It is found that microTA provides precise and accurate micro-thermal analytical data with 0.1 K thermal sensitivity, which is comparable to that obtained by DSC measurements of bulk samples. It is also shown that microTA offers the opportunity to study single particles and the interfacial region between particles, data which is currently inaccessible through the DSC technique.

Calorimetry, Differential Scanning↗

Biological infrared imaging and sensing.

A variety of thermoreceptors are present in animals and insects, which aid them in hunting, feeding and survival. Infrared (IR) imaging pit organs in Crotaline and Boid snakes enable them to detect, locate and apprehend their prey by detecting the IR radiation they emit. IR pit organs of common vampire bats (Desmodus rotundus) enable them to detect IR radiation emitted by blood-rich locations on homeothermic prey. The beetle Melanophila acuminata locates forest fires by IR-detecting pit organs in order to lay their eggs in freshly killed conifers. Thermoreceptors located in the wings and antennae of darkly pigmented butterflies (Pachliopta aristolochiae and Troides rhadamathus plateni) protect them from heat damage while sun basking. Blood-sucking bugs (Triatoma infestans) are speculated to possess thermoreceptors, which enable them to perceive the radiant heat emitted by homeothermic prey and estimate its temperature at a distance. This is a review of the diverse types of biological thermoreceptors, their structure and function, and how electron microscopy has been instrumental in determining their ultrastructure.

Animals↗

Nanoscale phenomena in synthetic functional oxide heterostructures.

This paper reviews nanoscale phenomena such as polarization relaxation dynamics and piezoelectric characterization in model ferroelectric thin films and nanostructures using voltage-modulated scanning force microscopy. Using this technique we show the three-dimensional reconstruction of the polarization vector in lead zirconate titanate (PZT) thin films. Second, the time-dependent relaxation of remanent polarization in epitaxial PZT ferroelectric thin films, containing a uniform two-dimensional grid of 90 degrees domains (c-axis in the plane of the film), has been investigated extensively. The 90 degrees domain walls preferentially nucleate the 180 degrees reverse domains during relaxation. Relaxation occurs through the nucleation and growth of reverse 180 degrees domains, which subsequently coalesce and consume the entire region as a function of relaxation time. In addition we also present results on investigation of the relaxation phenomenon on a very local scale, where pinning and bowing of domain walls has been observed. We also show how this technique is used for obtaining quantitative information on piezoelectric constants and by engineering special structures, and how we realize ultrahigh values of piezoconstants. Last, we also show direct hysteresis measurements on nanoscale capacitors, where there is no observable loss of polarization in capacitors as small as 0.16 microm2 in area.

Crystallization↗

Characterization of a novel light source for simultaneous optical and scanning ion conductance microscopy.

We have developed a novel light source suitable for imaging of biological samples. The method is based on the use of a micropipet filled with fluo-3. A fluorogenic complex is formed when fluo-3 meets calcium in the bath solution. The complex is excited by focusing a laser beam at the pipet tip to produce a submicrometer light source. This source is continually renewed at the tip, eliminating problems with photobleaching, and can be controlled by varying the applied potential. We first characterized the light source using fluorescence correlation measurements in order to optimize its properties. We then recorded an image of a model sample under buffer with submicrometer resolution using ion conductance distance control to demonstrate the feasibility of this approach.

Algorithms↗

Real-time pH microscopy down to the molecular level by combined scanning electrochemical microscopy/single-molecule fluorescence spectroscopy.

A new technique combining scanning electrochemical microscopy (SECM) and single-molecule fluorescence spectroscopy was developed to accomplish locally and temporally defined pH adjustments in buffer solutions and on surfaces monitored by fluorescence alteration of pH-sensitive fluorophores in real time. Local pH gradients were created by electrochemical generation of H(+) or OH(-) during redox reactions at ultramicro- or nanoelectrodes with radii from 5 microm to 35 nm. Ratiometric fluorescence measurements were performed with a confocal laser microscope using two detectors for different spectral regions. Time-resolved pH measurements were carried out with freely diffusing SNARF-1-dextran. For pH measurements on surfaces, total internal reflection fluorescence microscopy was used in combination with a CCD camera. The fluorophore SNAFL-succinimidyl ester was bound to amino-terminated octadecylsilane-coated coverslips. Local pH determinations could be accomplished with an accuracy of 0.2 unit. The measured pH profiles showed a strong dependence on the tip diameter, the buffer/mediator concentration ratio, and the tip-surface distance. As an application for bionanotechnology using SECM-induced pH changes on the molecular level, the proton-driven ATP synthesis by single membrane-bound F(0)F(1)-ATP synthases was investigated. ATP synthesis resulted in stepwise subunit rotation within the enzyme that was monitored by single-molecule fluorescence resonance energy transfer.

Adenosine Triphosphate↗

Scanning electrochemical microscopy with a band microelectrode: theory and application.

Scanning electrochemical microscopy (SECM) is described using a band microelectrode tip. Numerical calculations allow the determination of approach curves of an insulating or a conductive substrate, and the numerical analysis is compared to experimental curves. Natural convection provides a steady-state current at the band microelectrode at an infinite distance from the substrate, and the band tip may be used in the SECM configuration as easily as the tip of a disk. Owing to the millimetric dimension of the band microelectrode, the substrate has an influence on the current at much longer distances than with the disk. Finally, the advantage of SECM with a band microelectrode is observed with the fast electrochemical modification of a fluoropolymer surface.

Electrochemistry↗

Biological thermal detection: micromechanical and microthermal properties of biological infrared receptors.

Bioinspired design of biomimetic sensors relies upon the complete understanding of properties and functioning of biological analogues in conjunction with an understanding of their microstructural organization at various length scales. In the spirit of this approach, the microscopic properties of infrared (IR) receptors of snakes with "infrared vision" were studied with scanning thermal microscopy and micromechanical analysis. Low surface thermal conductivity of 0.11 W/(m K) was measured for the IR receptor surfaces as compared to the nonspecific skin areas. This difference in surface thermal conductivity should result in a significant local temperature gradient around the receptor areas. Micromechanical analysis showed that pit organs were more compliant than surrounding skin areas with an elastic modulus close to 40 MPa. In addition, the maximum elastic modulus was detected for the outermost layer with gradually reduced elastic resistance for the interior. The porous microstructure of the underlying tissue combined with the highly branched microfibrillar network (Biomacromolecules 2001, 2, 757) is thought to be responsible for such a combination of biomaterial properties. Considering these biomaterials features, we postulated a possible design of an artificial photothermal detector inspired by the microstructure of natural receptors. This bioinspired design would include a microfabricated cavity filled with an ordered lattice of microspheres with a gradient periodicity from the surface to the interior. Such a "photonic cavity" could provide an opportunity for multiple scattering at wavelength tuned to 8-12 microm as a range of highest sensitivity.

Animals↗

Effect of sample and substrate electric properties on the electric field enhancement at the apex of SPM nanotips.

Finite element (FE) models were built to define the optimal experimental conditions for tip-enhanced Raman spectroscopy (TERS) of thin samples. TERS experimental conditions were mimicked by including in the FE models dielectric or metallic substrates with thin dielectric samples and by considering the wavelength dependence of the dielectric properties for the metallic materials. Electromagnetic coupling between the substrate/sample and the SPM tips led to dramatic changes of both the spatial distribution and magnitude of the scattered electric field which depended on the substrate dielectric permittivity and excitation wavelength. Raman scattering as high as 10(8) with a spatial resolution of approximately 8 nm was estimated for gold SPM tips and gold substrate when excitation is performed at 532 nm (near-resonance wavelength). For dielectric samples (approximately 4 nm thick), the enhancement of Raman scattering intensity is estimated at approximately 10(5); this does not depend significantly on the sample dielectric permittivity for dielectric samples. These results suggest that TERS experimental conditions should be estimated and optimized for every individual application considering the geometric factors and electric properties of the materials involved. Such optimizations could enlarge the range of applications for TERS to samples eliciting weaker intrinsic Raman scattering, such as biological samples.

Algorithms↗

Modeling steady-state experiments with a scanning electrochemical microscope involving several independent diffusing species using the boundary element method.

The BEM algorithm developed earlier for steady-state experiments in the scanning electrochemical microscopy (SECM) feedback mode has been expanded to allow for the treatment of more than one independently diffusing species. This allows the treatment of substrate-generation/tip-collection SECM experiments. The simulations revealed the interrelation of sample layout, local kinetics, imaging conditions, and the quality of the obtained SECM images. Resolution in the SECM SG/TC images has been evaluated, and it depends on several factors. For most practical situations, the resolution is limited by the diffusion profiles of the sample. When a dissolved compound is converted at the sample (e.g., oxygen reduction or enzymatic reaction at the sample), the working distance should be significantly larger than in SECM feedback experiments (ca. 3 r(T) for RG = 5) in order to avoid diffusional shielding of the active regions on the sample by the UME body. The resolution ability also depends on the kinetics of the active regions. The best resolution can be expected if all the active regions cause the same flux. In one simulated example, which might mimic a possible scenario of a low-density protein array, considerable compromises in the resolving power, were noted when the flux from two neighboring spots differs by more than a factor of 2.

Algorithms↗

Scanning electrochemical microscopy (SECM) studies of oxygen transfer across phospholipid monolayers under surface pressure control: comparison of monolayers at air/water and oil/water interfaces.

Scanning electrochemical microscopy has been used in combination with a specially designed Langmuir trough to compare the kinetics of oxygen transfer across an L-alpha-phosphatidylethanolamine, distearoyl monolayer spread at three different interfaces: air/water, air/water in contact with an oil lens, and oil/water. The monolayer is shown to reduce the kinetics of interfacial transport, and rate constants for the transport of oxygen across each interface, at different surface pressures, have been evaluated. The results obtained for each interface are compared, and the implications for studies of passive diffusion across cell membranes are discussed.

Air↗

Heterogeneous molecular distribution in supported multicomponent lipid bilayers.

Membrane domains contribute important structural and functional attributes to biological membranes. We describe the heterogeneous nanoscale distribution of lipid molecules within microscale membrane domains in multicomponent lipid bilayers composed of dipalmitoylphosphatidylcholine (DPPC), dilauroylphosphatidylcholine (DLPC), and cholesterol (chol). The lipids were labeled with the fluorescent lipid analogues Bodipy-PC and DiI-C20:0 to identify the distribution of individual membrane components. We used a near-field scanning optical microscope (NSOM) at room temperature to identify the nanoscale structures in the membrane. Simultaneous multicolor NSOM imaging at the emission maxima of the fluorescent analogues revealed a patchy distribution of Bodipy-PC and DiI-C20:0 indicative of phase separations in the bilayer. In a cholesterol-free system (DPPC/DLPC = 1:1), NSOM images proved that the two phosphatidylcholine molecules can coexist in domains at the micrometer level but form nanoscopic patches within the domains; DPPC occurs at the edge of the domains, whereas DLPC is present throughout the domains. In the presence of cholesterol (DPPC/DLPC = 7:3, chol = 18.9%), the two lipid molecules were more miscible but incomplete phase separations also occurred. The average domain sizes were 140-200 nm, well below the resolution capabilities of diffraction-limited light microscopy techniques; the domains were unresolvable by confocal microscopy. Our high-resolution NSOM studies of membrane domain behavior provide a better understanding of complex membrane phase phenomena in multicomponent biological membranes.

1,2-Dipalmitoylphosphatidylcholine↗

Synthesis and structural characterization of glucopyranosylamide films on gold.

Self-assembled monolayers (SAMs) of glucose derivatives on gold have been prepared from alpha- and beta-glucopyranosylamide derivatives. The glucosyl conjugates were synthesized stereoselectively via the in situ generation of glucosyl isoxazolines followed by treatment with thiopyridyl esters. The resulting film structures were characterized by atomic force microscopy, reflection Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. The experimental data indicated that alpha- or beta-linked glucopyranosylamide derivatives with free hydroxyl groups attach to gold via the thiol linker. Both derivatives form monolayer films with high packing densities--comparable to those typically observed for alkanethiol monolayers on gold. Acetate analogues of these conjugates do not form SAMs on gold; they form multilayered films under identical deposition conditions.

Adsorption↗

Correlation between surface photovoltage and blend morphology in polyfluorene-based photodiodes.

We present a microscopic study of photoinduced charge generation in polyfluorene-based photovoltaic structures. The sub-100 nm lateral resolution of scanning Kelvin probe microscopy allows characterizing the three-dimensional structure of thin films of blends of poly-(9,9'-dioctylfluorene-co-benzothiadiazole) (F8BT) and poly-(9,9'-dioctylfluorene-co-bis-N,N'-(4-butylphenyl)-bis-N,N'-phenyl-1,4-phenylenediamine) (PFB). From the strong correlation between surface photovoltage and blend morphology, we propose a simple model for the lateral and vertical film structure identifying in particular those regions with the most efficient conduction pathway for the photocurrent.

Journal Article↗

Ultrafast dynamics of a ferromagnetic nanocomposite.

Ensembles of iron nanocrystals up to 25 nm in diameter embedded in SiO(2) were found to exhibit an ultrafast magnetic response to a transient out-of-plane magnetic field. The response time varies as a function of in-plane bias magnetic field with the fastest rise times, as short as 26 ps, observed for both zero and high bias fields (140 kA/m). Analytical modeling and micromagnetic simulations confirm that magnetostatic interactions between nanoparticles play an important role in the dynamic response.

Computer Simulation↗