Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Endothelial cell density determined by specular microscopy and scanning electron microscopy.

Human eyes were photographed with a specular microscope and later examined wit a scanning electron microscope. Corneas from patients undergoing corneal transplantation in whom we were able to obtain preoperative specular micrographs were similarly analyzed. An attempt was made to correlate the counts obtained with both microscopic techniques by determining the amount of shrinkage the cornea undergoes while being processed for SEM. All specimens were counted with a planimeter. We found that the specular microscope adequately analyzes the endothelial cell density in the central and paracentral cornea of a normal eye, but because of its small sampling area specular microscopic counts are subject to significant error when dealing with nonhomogeneous populations such as postoperative cases. We found the peripheral corneal endothelial density to be less than the central endothelial density. Furthermore, we found that we could maximize the accuracy of counting by using a variable frame in a nonhomogeneous population, counting a minimum of four photographs per specimen, analyzing different areas, and analyzing larger areas.

Adolescent↗

Numerical simulation of scanning electrochemical microscopy experiments with frame-shaped integrated atomic force microscopy--SECM probes using the boundary element method.

Integrated submicroelectrodes for combined AFM-SECM measurements are characterized with numerical simulations using the boundary element method. SECM approach curves and SECM images are calculated and analyzed for a model substrate containing pronounced topographical and electrochemical features. The theoretically calculated image has been compared to the experimental data and shows excellent quantitative agreement. Hence, the applicability of integrated AFM-SECM electrodes for combined electrochemical and topographical imaging and a profound theoretical description including quantification of the obtained results are demonstrated.

Electrochemistry↗

A new miniature hydrostatic pressure chamber for microscopy. Strain-free optical glass windows facilitate phase-contrast and polarized-light microscopy of living cells. Optional fixture permits simultaneous control of pressure and temperature.

This paper describes the development of a miniature, temperature-controlled, stainless steel pressure chamber which uses strain-free optical glass for windows. It is directly adaptable to standard phase-contrast and polarized-light microscopes and requires a minimum amount of equipment to generate and measure pressure. Birefringence retardation (BR) og 0.1 nm up to 3,000 psi, 0.4 nm up to 5,000 psi and 1.0 nm up to 10,000 psi can be detected over a 0.75-mm central field with two strain-free Leitz 20 times UM objectives, one used as a condenser. In phase-contrast studies a Nikon DML 40 times phase objective and Zeiss model IS long working-distance phase condenser were used, with little deterioration of image quality or contrast at pressures as high as 12,000 psi. The actual design process required a synthesis of various criteria which may be categorized under four main areas of consideration: (a) specimen physiology; (b) constraints imposed by available optical equipment and standard microscope systems; (c) mechanical strength and methods for generating pressure; and (d) optical requirements of the chamber windows. Procedures for using the chambers, as well as methods for shifting and controlling the temperature within the chamber, are included.

Atmosphere Exposure Chambers↗

A correlative study by electron and light microscopy of the development of type 5 adenovirus. I. Electron microscopy.

Stages in the nuclear changes consequent to infection with type 5 adenovirus are shown and described. Viral development seems to be confined to the nucleus where characteristic particles are found. The shape of the intracellular virus depends upon the method of preservation employed, appearing spherical after osmium tetroxide or freezing-substitution, occasionally exhibiting angulated faces after formalin and often assuming an hexagonal profile after potassium permanganate. The non-viral crystals are encountered in zones of low density, and it is suggested that crystallization results from the accumulation of protein in these areas. An hypothesis is presented to explain why these crystals, in contrast to the insect polyhedra, contain few viral particles.

Adenoviridae↗

In vivo monitoring of the potassium channel KcsA in Streptomyces lividans hyphae using immuno-electron microscopy and energy-filtering transmission electron microscopy.

The previous discovery of the Streptomyces lividans kcsA gene and its overexpression followed by the functional reconstitution of the purified gene product has resulted in new strategies to explore this channel protein in vitro. KcsA has evolved as a general model to investigate the structure/function relationship of ion channel proteins. Using specific antibodies raised against a domain of KcsA lacking membrane-spanning regions, KcsA has now been localized within numerous separated clusters between the outer face of the cytoplasm and the cell envelope in substrate hyphae of the S. lividans wild-type strain but not in a designed chromosomal disruption mutant DeltaK, lacking a functional kcsA gene. Previous findings had revealed that caesium ions led to a block of KcsA channel activity within S. lividans protoplasts fused to giant vesicles. As caesium can be scored by electron energy loss spectroscopy better than potassium, this technique was applied to hyphae that had been briefly exposed to caesium instead of potassium ions. Caesium was found preferentially at the cell envelope. Compared to the DeltaK mutant, the relative level of caesium was approximately 30 % enhanced in the wild-type. This is attributed to the presence of KcsA channels. Additional visualization by electron spectroscopic imaging supported this conclusion. The data presented are believed to represent the first demonstration of in vivo monitoring of KcsA in its original host.

Cesium↗

Scanning tunneling microscopy and atomic force microscopy: application to biology and technology.

The scanning tunneling microscope (STM) and the atomic force microscope (AFM) are scanning probe microscopes capable of resolving surface detail down to the atomic level. The potential of these microscopes for revealing subtle details of structure is illustrated by atomic resolution images including graphite, an organic conductor, an insulating layered compound, and individual adsorbed oxygen atoms on a semiconductor. Application of the STM for imaging biological materials directly has been hampered by the poor electron conductivity of most biological samples. The use of thin conductive metal coatings and replicas has made it possible to image some biological samples, as indicated by recently obtained images of a recA-DNA complex, a phospholipid bilayer, and an enzyme crystal. The potential of the AFM, which does not require a conductive sample, is shown with molecular resolution images of a nonconducting organic monolayer and an amino acid crystal that reveals individual methyl groups on the ends of the amino acids. Applications of these new microscopes to technology are demonstrated with images of an optical disk stamper, a diffraction grating, a thin-film magnetic recording head, and a diamond cutting tool. The STM has even been used to improve the quality of diffraction gratings and magnetic recording heads.

Animals↗