Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Measuring algorithm”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics.

OBJECTIVE: To present an algorithm for noninvasive measurement of cerebral oxygen saturation (cerebral oximetry) and cerebral hemodynamics with near infrared spectroscopy. DESIGN: In vitro correlation of oximetry measurements with reference measurements; illustrative cases of hemodynamic and oximetric recordings. SETTING: Tertiary care neuroscience ICU. PATIENTS: Brain-injured patients with a prolonged, decreased level of consciousness chosen as illustrative examples. INTERVENTIONS: Two-channel multiple wavelength diffuse infrared transmission spectroscopy was interfaced with the scalp using adhesive. Transmission data were collected with gross superficial-to-deep spatial resolution. Saturation calculation based on the deep signal was observed longitudinally in the patient. With the same technology, arterial input and cerebral response functions, generated by iv tracer bolus, were deconvoluted to measure mean cerebral transit time. MEASUREMENTS AND MAIN RESULTS: A positive linear regression fit between diffuse transmission oximetry and measured blood oxygen saturation over the range 23% to 99% (r2 = .98, p less than .001) was noted. CONCLUSIONS: The approach used overcomes previously identified difficulties with cerebral oximetry, and demonstrates excellent in vitro correlation. The technique can be performed clinically without difficulty. A simultaneous measure of mean cortical transit time is possible.

Brain↗

Transthoracic monitoring of the impedance of the right lung in patients with cardiogenic pulmonary edema.

OBJECTIVE: To evaluate the suitability of the new electrical impedance monitor RS-205 for monitoring of cardiogenic pulmonary edema (CPE). DESIGN: Prospective, controlled study. SETTING: A department of internal medicine in a 1,200-bed university-affiliated, teaching hospital. PATIENTS: Sixty patients, aged 52-80 yrs, 30 without CPE (controls) and 30 with or at high risk for CPE. INTERVENTIONS: Internal thoracic impedance (ITI) was monitored by the RS-205. The RS-205 is approximately three times more sensitive than the Kubicek monitor, and it eliminates the effect of the drift of skin-to-electrode impedance. This is achieved by eliminating skin electrode impedance by a special algorithm, thus allowing measurement of ITI rather than total transthoracic impedance. Measuring ITI, the main component of which is lung impedance, is a noninvasive and safe method. CPE was diagnosed in accordance with well-accepted clinical and roentgenological criteria. MEASUREMENTS AND MAIN RESULTS: The controls' initial ITI was 68.3 +/- 12.38 ohms. During 6 hrs of monitoring, the ITI attained a minimum average value of -1.3 +/- 2.08% and a maximum average value of 4.6 +/- 3.56% relative to baseline. In all patients entering CPE, ITI decreased by 14.4 +/- 5.42% on the average (p <.001) 1 hr before the appearance of clinical symptoms. In patients with evolving CPE, ITI decreased significantly compared with controls (22.25 +/- 9.82%, p <.001). In patients at the peak of pulmonary edema, ITI was 2.1 times lower than in the control group (33.1 +/- 10.90 ohms, p <.001). In the last hour before the resolution of CPE, ITI increased in all patients by 17.7 +/- 19.74% compared with the peak of disease (p <.05). After the resolution of pulmonary edema, ITI increased in all patients by 44.14 +/- 26.90% compared with the peak of disease (p <.001). Importantly, the trend in ITI in all patients changed in accordance with the dynamics of CPE. A mixed general linear model shows that ITI values correlated well with the degree of crepitation, a direct characteristics of CPE. CONCLUSIONS: The RS-205 is suitable for monitoring patients at high risk of CPE development. It enables detection of CPE and the monitoring of patients at all stages of CPE.

Aged↗

Assessment of prevalence of left ventricular hypertrophy in hypertension.

The reported prevalence of left ventricular hypertrophy (LVH) in human hypertension is much lower than that among animals with experimental hypertension. With current methods of determining left ventricular mass by M-mode echocardiography, the standard error of a single estimate is high and consequently so is the SD of the population distribution. This accounts for the large overlap in individual values of left ventricular mass index (LVMI) between hypertensive and normotensive groups. The high SD is due to the use of the cube algorithm for relating measurements made in a single plane to the whole left ventricle, and to the difference between actual and assumed left ventricular geometries. These are not problems with nuclear magnetic resonance imaging, which provides information about the entire left ventricle without assumptions about geometry. M-mode echocardiography is well suited for estimating differences between mean LVMI values for groups of subjects but it underestimates the prevalence of LVH. In most series only about 30% of hypertensives have been reported to have LVH. The estimated prevalence of structural remodelling is increased to 50-60% of the same group of subjects when 'low-SD' measurements such as wall thickness and the wall thickness: internal radius ratio are employed. The estimated prevalence of LVH and remodelling is still greater with multivariate discriminant function analysis, with which it is found in about 70% of hypertensives. Overall, the data suggest that prevalence of LVH in established hypertension is high. The 30% of subjects reported to have LVH on the basis of LVMI measurements that are beyond the limits of the control group probably have the most severe changes. The inability to detect lesser grades of left ventricular remodelling reliably is due to the way LVMI is derived by echocardiography, rather than to intrinsic inaccuracies. It suggests that existing approaches should be supplemented by greater use of 'low-SD' variables and discriminant functions. Detecting the full spectrum of left ventricular structural changes in individuals with hypertension is needed for risk assessment and, increasingly, for management aimed at minimizing irreversible myocardial damage. Nuclear magnetic resonance imaging provides 'global' and more accurate information about left chamber structure than does M-mode echocardiography but its cost at present is much greater. Nevertheless, the information provided by echocardiography may be adequate for the above applications, but the high SD of LVMI is a weakness. Greater use of 'low-SD' variables and multivariate discriminant functions may help overcome this problem.

Animals↗

Distinguishing panic disorder and agoraphobia from social phobia.

An attempt was made to differentially diagnose panic disorder with agoraphobia from social phobia on the basis of self-reported phobic situations, panic attack symptomatology, and feared outcomes. Sixty-nine patients with panic disorder (with and without agoraphobia) were compared with 69 patients with social phobia. Subjects completed a modified self-report version of the panic and phobia sections from the Composite International Diagnostic Interview to assess phobic situations, panic symptomatology, and feared outcomes. The two groups were distinguishable on all three measures. A diagnostic algorithm was developed that predicted the primary diagnosis allocated by a clinician for subjects who meet DSM-III-R criteria for panic disorder (with or without agoraphobia) rather than social phobia on the basis of self-reported phobic avoidance, panic symptomatology, and feared outcomes.

Adult↗

Risk adjustment using automated ambulatory pharmacy data: the RxRisk model.

OBJECTIVES: Develop and estimate the RxRisk model, a risk assessment instrument that uses automated ambulatory pharmacy data to identify chronic conditions and predict future health care cost. The RxRisk model's performance in predicting cost is compared with a demographic-only model, the Ambulatory Clinical Groups (ACG), and Hierarchical Coexisting Conditions (HCC) ICD-9-CM diagnosis-based risk assessment instruments. Each model's power to forecast health care resource use is assessed. DATA SOURCES: Health services utilization and cost data for approximately 1.5 million individuals enrolled in five mixed-model Health Maintenance Organizations (HMOs) from different regions in the United States. STUDY DESIGN: Retrospective cohort study using automated managed care data. SUBJECTS All persons enrolled during 1995 and 1996 in Group Health Cooperative of Puget Sound, HealthPartners of Minnesota and the Colorado, Ohio and Northeast Regions of Kaiser-Permanente. MEASURES RxRisk, an algorithm that classifies prescription drug fills into chronic disease classes for adults and children. RESULTS: HCCs produce the most accurate forecasts of total costs than either RxRisk or ACGs but RxRisk performs similarly to ACGs. Using the R(2) criteria HCCs explain 15.4% of the prospective variance in cost, whereas RxRisk explains 8.7% and ACGs explain 10.2%. However, for key segments of the cost distribution the differences in forecasting power among HCCs, RxRisk, and ACGs are less obvious, with all three models generating similar predictions for the middle 60% of the cost distribution. CONCLUSIONS: HCCs produce more accurate forecasts of total cost, but the pharmacy-based RxRisk is an alternative risk assessment instrument to several diagnostic based models and depending on the nature of the application may be a more appropriate option for medical risk analysis.

Adolescent↗

Estimating lung mechanics of dogs with unilateral lung injury.

Extended least-squares algorithms using transpulmonary pressure and airway flow data from ventilatory waveforms were studied for their ability to track parameters of one- and two-compartment models of lung mechanics. A recursive extended least-squares algorithm with discounted measures estimated parameters of discrete-time models during synchronized intermittent mandatory ventilation. In tests on seven dogs developing oleic acid-induced unilateral hemorrhagic pulmonary edema, the one-compartment estimator responded rapidly and appropriately to changes in mechanics: compliance fell to 0.55 +/- 0.15 of its initial value and resistance rose by a factor of 1.8 +/- 0.5 in 3 h following injection of oleic acid. One-compartment parameter estimates revealed a difference between the airway resistance of inspiration and expiration. Two-compartment estimates were seldom physiologically plausible. The difference between inspiratory and expiratory resistance may have caused the two-compartment estimator to fail when applied to data from the entire respiratory cycle; when only expiratory data were used for estimation, the two-compartment estimates were meaningful. These estimates demonstrated increasing lung inhomogeneity after oleic acid was injected; at the end of 3 h, the ratio of the time constants of the two compartments ranged from 5 to 20 in six of the seven dogs. We conclude that the one- and two-compartment estimates may be combined to provide a meaningful assessment of lung mechanics.

Animals↗

The application of cepstral coefficients and maximum likelihood method in EMG pattern recognition.

A new technique for classifying patterns of movement via electromyographic (EMG) signals is presented. Two methods (conventional autoregressive (AR) coefficients and cepstral coefficients) for extracting features from EMG signals and three classification algorithms (Euclidean Distance Measure (EDM), Weighted Distance Measure (WDM), and Maximum Likelihood Method (MLM)) for discriminating signals representative of broad classes of movements are described and compared. These three classifiers are derived from Bayes classifier with some assumptions, the relationship among them is discussed. The conventional MLM is modified to avoid heavy matrix inversion. Six able-bodied subjects with two pairs of surface electrodes located on bilateral sternocleidomastoid and upper trapezius muscles were studied in the experiment. The EMG signals of 20 repetitions of 10 motions were analyzed for each subject. Experimental results showed that mean recognition rate of the cepstral coefficients was at least 5% superior to that of the AR coefficients. The improvement achieved by the cepstral method was statistically significant for all the three classifiers. Reasons for the superiority of cepstral features were investigated from the feature space and frequency domain, respectively. The cepstral coefficients owned better cluster separability in feature space and they emphasized the more informative part in the frequency domain. The discrimination rate of the MLM was the highest among three classifiers. Incorporation of the cepstral features with the MLM could reduce the misclassification rate by 10.6% when compared with the combination of AR coefficients and EDM. Proper choice of five of ten motions could further raise the recognition rate to more than 95%.

Adult↗

Effects of follicular phase exercise on luteinizing hormone pulse characteristics in sedentary eumenorrhoeic women.

OBJECTIVE: Current studies reveal little regarding the inception of exercise-induced LH changes during physical training. This study aimed to assess the susceptibility of the hypothalamic-pituitary axis to the acute physical stress of exercise in untrained, physically inactive women. The acute effects of submaximal endurance exercise upon the pulsatile LH secretion in the follicular phase were compared with those accompanying leisurely strolling for a similar time period. SUBJECTS: All subjects were eumenorrhoeic, as determined by biphasic temperature patterns, detection of the urinary LH surge, and mid-luteal serum progesterone levels. Subjects were not physically active and had little history of strenuous exercise (VO2max = 38.0 +/- 1.8) (mean +/- SEM) ml/kg/min). DESIGN: All women completed a 13.5-hour pulsatility test which included three consecutive 20-minute runs on a treadmill at 50, 60 and 70% of the subjects' maximum oxygen uptake (n = 16). Six of these same subjects completed a separate test on another occasion in which one hour of leisurely strolling was substituted for exercise. Blood was sampled every 10 minutes via an indwelling cannula for 4.5 hours before and 8 hours after one hour of exercise and or strolling. MEASUREMENTS: A pulse algorithm (Pulsar) was used to quantify LH pulse characteristics. RESULTS: Exercise produced no significant effects upon LH pulse frequency or mean serum LH concentration. However, exercise of moderate intensity caused a significant increase in LH pulse amplitude (P < 0.05). Strolling produced no significant changes in LH secretion. CONCLUSION: Acute exercise of moderate intensity in the follicular phase of untrained women is an insufficient stimulus to inhibit the GnRH pulse generator in the post-exercise period, yet may produce a slight stimulatory effect on the amount of LH released per pulse.

Adult↗

Evaluation of mechanisms behind elevated energy expenditure in cancer patients with solid tumours.

The aim of this study was to demonstrate significant factors behind elevated resting energy expenditure in weight-losing cancer patients. Therefore, weight-losing cancer patients (n = 60), with normal liver and kidney function tests, were randomized to receive one of four drug treatments for 5 days: (a) Propranolol 80 mg x 2 (beta-adrenoceptor blockade); (b) Indomethacin 50 mg x 2 (prostaglandin synthesis inhibition); (c) Morphine 5 mg x 3 (pain relief) or (d) Placebo x 2. A reference group of healthy well-nourished individuals were examined outside the formal randomization protocol and they received Propranolol 80 mg x 2. The cancer patients were randomized by a computer based algorithm stratifying for measured resting energy expenditure (REE), body composition, biochemical tests, previous therapy, tumour type and tumour stage. Resting energy expenditure was measured by indirect calorimetry in the morning after an overnight fast before and after drug treatment. beta-blockade reduced REE significantly in cancer patients from 1416 +/- 95 kcal day-1 to 1160 +/- 63 kcal day-1 (P < 0.02) and from 1472 +/- 69 vs, 1398 +/- 63 kcal day-1 (P < 0.01) in the well-nourished reference individuals. The reduction found in cancer patients (10%) was significantly larger than that in the group of reference patients (5%), (P < 0.01). Indomethacin, morphine or placebo did not induce any significant alteration in energy expenditure in our cancer patients. Propranolol treatment was associated with a significant reduction in plasma concentrations of free fatty acids (FFA), but not in plasma glycerol.(ABSTRACT TRUNCATED AT 250 WORDS)

Basal Metabolism↗

Coding of the fundamental frequency in continuous interleaved sampling processors for cochlear implants.

In this study the perception of the fundamental frequency (F0) of periodic stimuli by cochlear implant users is investigated. A widely used speech processor is the Continuous Interleaved Sampling (CIS) processor, for which the fundamental frequency appears as temporal fluctuations in the envelopes at the output. Three experiments with four users of the LAURA (Registered trade mark of Philips Hearing Implants, now Cochlear Technology Centre Europe) cochlear implant were carried out to examine the influence of the modulation depth of these envelope fluctuations on pitch discrimination. In the first experiment, the subjects were asked to discriminate between two SAM (sinusoidally amplitude modulated) pulse trains on a single electrode channel differing in modulation frequency ( deltaf = 20%). As expected, the results showed a decrease in the performance for smaller modulation depths. Optimal performance was reached for modulation depths between 20% and 99%, depending on subject, electrode channel, and modulation frequency. In the second experiment, the smallest noticeable difference in F0 of synthetic vowels was measured for three algorithms that differed in the obtained modulation depth at the output: the default CIS strategy, the CIS strategy in which the F0 fluctuations in the envelope were removed (FLAT CIS), and a third CIS strategy, which was especially designed to control and increase the depth of these fluctuations (F0 CIS). In general, performance was poorest for the FLAT CIS strategy, where changes in F0 are only apparent as changes of the average amplitude in the channel outputs. This emphasizes the importance of temporal coding of F0 in the speech envelope for pitch perception. No significantly better results were obtained for the F0 CIS strategy compared to the default CIS strategy, although the latter results in envelope modulation depths at which sub-optimal scores were obtained in some cases of the first experiment. This indicates that less modulation is needed if all channels are stimulated with synchronous F0 fluctuations. This hypothesis is confirmed in a third experiment where subjects performed significantly better in a pitch discrimination task with SAM pulse trains, if three channels were stimulated concurrently, as opposed to only one.

Acoustic Stimulation↗

Characteristics of exogenous lipid uptake by renal and intestinal brush-border membrane vesicles.

The transfer of radioactive phosphatidylcholine (PC*) from liposomes to rabbit jejunal and renal brush-border membrane vesicles (BBMVs) was measured with a fast-sampling, rapid-filtration apparatus. PC* uptake by jejunal and renal BBMVs was favoured when liposomes were made from soybean phosphatidylcholine (azolectin, AZO), whereas PC* uptake could not be quantitatively assessed from egg yolk phosphatidylcholine (PC) liposomes even after a 22-h period of incubation. The increased turbidity of BBMV dispersion following the addition of CaCl2 or HCl to AZO-treated BBMVs suggested that negatively charged lipids and phosphatidylethanolamine are transferred during the process. These data and the analysis of PC*-uptake time measurements, using an algorithm simulating aggregation phenomena, indicated that the reaction mechanism involved liposome aggregation to BBMVs rather than specific lipid transfer. The constants of the dimerization reaction between AZO liposomes and BBMVs were evaluated to be 0.016 +/- 0.006 min-1 for jejunal and 0.095 +/- 0.02 min-1 for renal preparations. IntraveSICULAR D-ASPartic acid accumulation in the presence of a NA+ gradient indicated that vesicles were still closed after coincubation with liposomes. In contrast, 70-85% of rabbit jejunal and renal Na(+)-D-glucose cotransporter activities were lost after overnight incubation with either AZO liposomes or buffered solution. Further, H(+)-ATPase activity in rabbit renal BBMVs largely decreased after coincubation with AZO liposomes, while brush-border membrane associated enzymes remained stable. These results demonstrate that coincubation of BBMV with liposomes of different composition may represent a useful approach to study the influence of lipidic environment on various membrane protein functions.

Animals↗

Coronary artery calcium: accuracy and reproducibility of measurements with multi-detector row CT--assessment of effects of different thresholds and quantification methods.

PURPOSE: To evaluate the effects of different thresholds and quantification methods on the accuracy and reproducibility of coronary calcium measurements with multi-detector row computed tomography (CT). MATERIALS AND METHODS: A cardiac CT phantom containing predetermined calcified cylinders was scanned. Calcium volume and mass were measured at various threshold values ranging from 80 to 230 HU. In 32 patients, two consecutive CT scans were obtained, and the coronary artery calcium score, volume, and mass were measured by one observer at 130- and 90-HU thresholds. Correlation analysis and analysis of variance were performed to evaluate the measurement errors in the phantom study and the interscan variability in the clinical study. RESULTS: In the phantom, mass measurement error varied with threshold and calcium density (P <.01). Mass error was strongly correlated with volume error (r = 0.91, P <.01) but with a much smaller range. In the clinical study, interscan variability of mass measurements was significantly lower than that with other measurement methods for both patients and individual vessels. For the patients, the mean interscan variability of calcium score, volume, and mass at the 130-HU threshold was 20.4%, 13.9%, and 9.3%, respectively. For all methods, interscan variability was not significantly different between the 130- and 90-HU thresholds (P >.05). CONCLUSION: The mass measurement is more accurate, less variable, and more reproducible in coronary calcium quantification than are measurements with other algorithms. Accurate quantification of calcium in each calcified plaque may require that the threshold be set individually, depending on the calcium density.

Algorithms↗

Absolute left ventricular volume by an iterative build-up factor analysis of gated radionuclide images.

A method for determining absolute left ventricular (LV) volumes from radionuclide gated blood-pool (GBP) images was validated in 34 patients. The technique is nongeometric, corrects for tissue attenuation, and uses an experimentally determined set of build-up factors to account for the effects of scatter. Only four parameters are needed to determine LV volumes: the LV count rates from a left anterior oblique (LAO) and a right posterior oblique (RPO) image (180 degrees opposed to the LAO), a venous blood sample, and a patient thickness measurement. A computer algorithm is used to reach an iterative solution to two simultaneous equations that yield LV volumes. Phantom studies showed less than 4% error for volume determinations at all investigated depths. For the patients studied the correlation between volumes obtained by GBP and contrast ventriculography was 0.97 for diastole and 0.96 for systole.

Adult↗

The effect of the interval between blood pressure determinations on the delay in the detection of changes: a computer simulation.

UNLABELLED: The frequency of automated noninvasive blood pressure (NIBP) measurements during routine anesthesia is a balance between potentially deleterious effects of frequent cycling and a delay in detecting changes caused by a long cycle time. A computer model generated systolic blood pressures that changed to a new, random value after a period of stability. We sampled these data at intervals between 1 and 10 min to simulate NIBP measurements. A separate algorithm, based on Trigg's Tracking Variable, indicated when a change had been detected. For each set of variables, the simulation was repeated 1000 times, and the average time to detect a change was recorded. The mean time to detect a change was 8.0 min with a 1-min cycle, 8.9 min with a 2-min cycle, 10.8 min with a 5-min cycle, and 13.0 min with a 10-min cycle. As the cycle time increased, the delay in detecting changes increased but only by approximately half the increase in the cycle time. The optimum variables for the trend detection algorithm also changed as the NIBP interval increased. Provided that abrupt changes in blood pressure are not anticipated, a 1- or 2-min cycle time for NIBP offers little advantage over a longer period. IMPLICATIONS: We used a computer model to study the effect of increasing noninvasive blood pressure (NIBP) sampling interval on the detection of blood pressure changes. The detection time increased only 50% of the increase in the sampling interval. This information may help optimize NIBP intervals in different circumstances.

Algorithms↗

An alterative method for hospital partition determination using hierarchical cluster analysis.

The classification of short-term hospitals into homogeneous groups has become an integral part of many systems designed to abate continuing cost inflation in the hospital industry. This paper describes one approach which was developed to identify homogeneous groups of short-term hospitals. The approach, based on hierarchical cluster analysis, defines an objective measure (called expected distinctiveness) to evaluate any group of hospitals identified by a hierarchical grouping structure or dendrogram. Using this measure, an efficient algorithm is developed which finds the hospital partition from the identified groups which maximizes total expected distinctiveness. A numerical example illustrates the application and extensions.

Analysis of Variance↗

Practical issues in wave-front sensing by use of phase diversity.

We present the results of the phase-diversity algorithm applied to simulated and laboratory data. We show that the exact amount of defocus distance does not need to be known exactly for the phase-diversity algorithm on extended scene imaging. We determine, through computer simulation, the optimum diversity distance for various scene types. Using laboratory data, we compare the aberrations recovered with the phase-diversity algorithm and those measured with a Fizeau interferometer that uses a He-Ne laser. The two aberration sets agree with a Strehl ratio of over 0.9. The contrast of the recovered object is found to be ten times that of the raw image.

Journal Article↗

[Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation].

Using a dual channel near infrared (NIR) in vivo optical spectroscopy (INVOS) system (INVOS 3100A, Somanetics Corp. Troy, MI, USA) we investigated the relationship between jugular venous oxygen saturation (SjvO2) and regional cerebral oxygen saturation (rSO2) in 30 infants and children (mean age 4.5 years) with congenital heart disease undergoing cardiac catheterisation. The NIRS-SomaSensor (emitter and dual receiver probe) was applied at a standardised right fronto-temporal location (over the right frontal cortex) on the infant's head and covered with an adhesive flexible bandage. Using NIR light (730 and 810 nm) and two source-detector spacings (3 and 4 cm from the transmitter), percentage values of rSO2 were calculated from detected haemoglobin saturations. Simultaneously, jugular venous oxygen saturation (SjvO2) monitoring was performed via a catheter placed in the right internal jugular vein with its tip positioned in the jugular bulb, as verified by fluoroscopy. To compare the reliability of NIRS measurement characteristics, jugular venous blood was analysed for SjvO2 as a reference measure of global cerebral oxygenation, by co-oximetry (OSM3-Hemoximeter, Radiometer Copenhagen, Denmark). Other measured variables included pulse oximetry, arterial blood pressure, and venous and arterial oxygen saturations. Over a jugular venous oxygen saturation range of 31-83%, a significant positive linear correlation was found between rSO2 (NIRS measurement) and SjvO2 (jugular bulb oximetry) (r = 0.93, p < 0.001). No significant correlation was observed between rSO2 values and arterial blood saturation or pulse oximetry. The quantitative correlation between rSO2 (haemoglobin oxygenation in a small hemi-elliptical area of the brain) and reference SjvO2 measurement (method for monitoring global cerebral oxygenation) suggests that NIRS measurement with subtraction algorithm should identify predominantly intracranial saturation in the pediatric age group, and will tend to reflect global oxygenation under physiological conditions. Transcranial oximetry using dual receiving channel NIRS offers a noninvasive, real-time, reliable and practicable means of monitoring cerebral haemoglobin oxygenation changes infants and children with cyanotic and noncyanotic congenital heart disease.

Adolescent↗

Laboratory quality control: using patient data to assess analytical performance.

Quality control plays a vital role helping to ensure the reliability of laboratory test results. The application of statistical quality control has been a component of laboratory medicine for approximately 50 years. Many of the control rules based on the early applications of statistical quality control have remained essentially unchanged since their initial introduction. Optimization of quality control rules can vary depending on the application for which a test is to be used. This review explores the various applications of laboratory quality control procedures and their role in identifying laboratory error. The ubiquitous use of computers in today's laboratories has enabled the development of more sophisticated means of assessing laboratory quality. The use of the Six Sigma technique and its adoption by the laboratory community is one example. Other examples include the use of patient-derived quality control procedures as a means of assessing laboratory performance. Early examples of these types of applications include use of Bull's algorithm, anion gap measurements, and delta checking. More recent applications include the correlation of laboratory test results, the average of normals procedure, and the Bhattacharya method.

Chemistry, Clinical↗