Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Matrix stiffness”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Cell-wall recovery after irreversible deformation of wood.

The remarkable mechanical properties of biological materials reside in their complex hierarchical architecture and in specific molecular mechanistic phenomena. The fundamental importance of molecular interactions and bond recovery has been suggested by studies on deformation and fracture of bone and nacre. Like these mineral-based materials, wood also represents a complex nanocomposite with excellent mechanical performance, despite the fact that it is mainly based on polymers. In wood, however, the mechanistic contribution of processes in the cell wall is not fully understood. Here we have combined tensile tests on individual wood cells and on wood foils with simultaneous synchrotron X-ray diffraction analysis in order to separate deformation mechanisms inside the cell wall from those mediated by cell-cell interactions. We show that tensile deformation beyond the yield point does not deteriorate the stiffness of either individual cells or foils. This indicates that there is a dominant recovery mechanism that re-forms the amorphous matrix between the cellulose microfibrils within the cell wall, maintaining its mechanical properties. This stick-slip mechanism, rather like Velcro operating at the nanometre level, provides a 'plastic response' similar to that effected by moving dislocations in metals. We suggest that the molecular recovery mechanism in the cell matrix is a universal phenomenon dominating the tensile deformation of different wood tissue types.

Adaptation, Physiological↗

[Biomechanical tests of a new scaffold for the cultivation of chondrocytes].

AIM: Scaffolds for the cultivation of chondrocytes are of increasing importance. So far, only little is known about their biomechanical properties. The present preliminary study addresses the biomechanical characteristics of a new collagen type I scaffold for the cultivation of chondrocytes. MATERIAL AND METHODS: Human chondrocytes were amplified in a monolayer and then cultivated in a 3D-scaffold over a period of up to 6 weeks. The biomechanical tests addressed the properties under uniaxial compression including stiffness and viscoelastic characteristics (creep and retardation). The obtained values were normalized against the thickness of the specimens and expressed as ratios. In addition, we present histological and quantitative PCR results (for collagen type II and aggrecan). RESULTS: The maximum force (or penetration force) revealed its highest values after a period of seven days. At this time the median value was 40 mN/mm. In the following period, a marked drop of the values was observed (19.8 mN/mm). With respect to the creep properties, we did not find any major changes over the period of six weeks. The median values were between 0.24 and 0.29 mm/mm. There were no significant differences between the samples seeded with chondrocytes and those which served as controls. A re-expansion of the samples was found with median values between 0.026 and 0.049 mm/mm (retardation). However, the original thickness was not reached after a period of 30 seconds with relief of the strain. Again, major differences of the values with respect to the duration of cultivation were not observed. Light microscopy revealed collagen type II and proteoglycans only in the pericellular region. CONCLUSION: In this study not all of the biomechanical properties of the cultivated tissue were investigated. The limitation of the tests to stiffness and viscoelastic properties was reasonable in view of a potential routine use. In addition, it may facilitate a comparison between different matrix systems. In our study, the cultivation of cells within the collagen matrix did not alter the mechanical properties of the scaffold.

Aggrecans↗

Energy restriction reduces bone density and biomechanical properties in aged female rats.

Bone mineral density (BMD) is highly correlated with body weight, and weight loss is associated with reduced BMD. Whether such losses of BMD increase skeletal fragility is unclear. We examined the effect of 9 wk of energy restriction (ER) on bone density, mineral and matrix protein composition and biomechanical properties in mature (20 wk old, n = 12) and aged (48 wk old, n = 16) female rats. Energy-restricted rats were fed 40% less energy than controls that consumed food ad libitum. Bone content of mineral (ash and calcium content) and matrix proteins (hydroxyproline, pyridinium crosslinks and proteoglycans), serum hormones, site-specific bone density and biomechanical properties (peak load, peak torque, shear stiffness and bending stiffness) were measured at the conclusion of the study. In both age groups, ER reduced body weight by 15 +/- 10% (P < 0.001) and dramatically decreased femoral bone density by 32-35% (P < 0.01) compared with controls. Energy restriction resulted in a small reduction in tibia and humerus density, as well as biomechanical properties in the aged but not mature rats (P < 0.05). Reduced serum levels of insulin and estradiol due to ER in aged rats (P < 0.05) may play a role in altering bone quality. These data show that although weight loss due to ER is detrimental to some bone parameters in mature rats, only aged rats show consistent reductions in bone density and biomechanical properties.

Aging↗

The effects of augmentation with Swine small intestine submucosa on tendon healing under tension: histologic and mechanical evaluations in sheep.

BACKGROUND: Rotator cuff failure after surgery may be attributed to inferior tissue healing properties that result from repetitive cyclic loading during early rehabilitation. Enhancing the biological healing process may reduce the incidence of failures after rotator cuff repairs. HYPOTHESIS: Augmentation of rotator cuff tissue using swine small intestine submucosa in a sheep model will improve the rate and quality of tissue repair. STUDY DESIGN: Controlled laboratory study. METHODS: We resected and reattached 26 sheep infraspinatus tendons under tension, with 13 animals receiving a small intestine submucosa patch (augmented group). Animals were sacrificed at 12 weeks, and biomechanical testing and histologic evaluation were performed. Biomechanical testing was completed in 10 tendons from each group. Specimens were loaded to failure at a constant displacement to obtain the load deformation curve used to calculate load to failure and stiffness of the healed bone-tendon interface. Histologic testing addressed tissue healing at the bone-tendon interface. RESULTS: The load-to-failure data did not indicate a significant difference between the augmented and nonaugmented groups (1252 +/- 402 N vs 985 +/- 459 N, respectively; P > .05). However, the augmented group had significantly better stiffness than the nonaugmented group (215 +/- 44 N/mm vs 154 +/- 63 N/mm, respectively; P = .03). Histologic data revealed that the infraspinatus tendon in all specimens inserted into the bone through a zone of fibrocartilage, although none of the patches were intact. CONCLUSION: Although there were no differences in the load-to-failure data between the 2 groups, the statistically significant improvement in stiffness for the augmented group is clinically relevant. Stiffness is the biomechanical parameter representing the tissue response to subdestructive loads seen with early rehabilitation. Augmenting the repair with a collagen matrix improved the early healing characteristics of the repair construct. CLINICAL RELEVANCE: Enhancing the biological process of tendon healing under tension by using a collagen matrix patch may improve the ultimate success of rotator cuff repair.

Animals↗

Elastic anisotropy of articular cartilage is associated with the microstructures of collagen fibers and chondrocytes.

Chondrocyte shape and volumetric concentration change as a function of depth in articular cartilage. A given chondrocyte shape produces different effects on the global material properties depending on the structure of the collagen fiber network. The shape and volumetric concentration of chondrocytes in articular cartilage appear to be related to the mechanical stability of the matrix. The present study was aimed to investigate, theoretically, the effects of the structural arrangement of the collagen fiber network, and the shape and distribution of chondrocytes, on the global material behavior of articular cartilage. Articular cartilage was assumed to be a four-phasic composite comprised of a matrix (associated with the properties of the proteoglycan structure), vertically and horizontally distributed collagen fibers, and spheroidal inclusions representing chondrocytes. A solution for composite materials was used to estimate the global, effective material properties of cartilage. Only the elasticity of the solid phase was investigated in the present study. Our simulations suggest that a soft, spheroidal cell inclusion in a fiber-reinforced proteoglycan matrix affects the material properties differently depending on the shape of the spheroidal inclusions. If the long axis of the inclusions is parallel to the collagen fibers, as in the deep zone, the soft inclusions increase the stiffness of the composite in the fiber direction, and reduce the stiffness of the composite in the direction normal to the fibers. Furthermore, we found that Young's modulus normal to the contact surface increases from the superficial to the deep zone in articular cartilage by a factor of 10-50, a finding that agrees well with experimental observations. Our analysis suggests that the combination of proteoglycan matrix, fiber orientation, and shape of chondrocytes are intimately related and are likely adapted to optimize the mechanical stability and load carrying capacity of the structure.

Anisotropy↗

Effect of 1 alpha-vitamin D3 on bone strength and composition in growing rats with and without corticosteroid treatment.

The effects of 1 alpha-vitamin D3 were studied for 6 months in 2-month-old male and female rats on a moderately low calcium diet with or without low-dose prednisolone treatment. Both cortical bone mechanical and biochemical properties were examined. Femoral bone specimens were subjected to torsional loading tests. With age, bone strength and stiffness increased in both sexes, accompanied by an increased degree of mineralization (bone ash and calcium concentrations). During growth, strength and stiffness increased more in male than in female rats. When 1 alpha-vitamin D3 (0.5 micrograms/kg/day) was given alone, bone mechanical competence improved significantly whereas insulin-like growth factor-I (IGF-I) and calcium concentrations in the bone matrix were significantly reduced. Treatment with low-dose prednisolone (0.5 mg/kg/day) alone did not influence bone mechanical properties compared with intact control rats (without prednisolone) although a significant reduction in calcium concentration and an increased phosphorus concentration were measured. A combined therapy with prednisolone and 1 alpha-vitamin D3 significantly increased bone strength, toughness, and stiffness compared with control bones. Both mineralization degree (ash and calcium concentration) and IGF-I concentration were decreased.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Pulse pressure, arterial stiffness, and drug treatment of hypertension.

Epidemiological studies in the past decade have stressed the importance of pulse pressure as an independent risk factor for cardiovascular morbidity and mortality. We briefly review the epidemiological evidence and discuss in more detail the pathophysiological basis for this observation and the therapeutic consequences. We focus on the vascular determinants of increased pulse pressure. Both longitudinal and cross-sectional components of the vascular system contribute to the shape of the arterial pressure wave and, thereby, to pulse pressure. The primary longitudinal component is the architecture of the arterial tree, which determines the major reflection sites for the pressure wave. The cross-sectional architecture of the vascular system consists of a geometric (diameter) and a structural (composition vessel wall) component. Both diameter and composition of the vessel wall vary greatly when going from central to more peripheral arteries. We review the implications for the functional properties of various arterial segments. Finally, we discuss the therapeutic consequences of targeting pulse pressure rather than mean blood pressure with various drug classes. Among the antihypertensive agents, nitrates, NO donors, and drugs that interfere with the renin-angiotensin-aldosterone system may offer useful tools to lower pulse pressure, in addition to mean blood pressure. Future developments may include non-antihypertensive agents that target collagen or other components of the arterial wall matrix. However, large-scale clinical trials will have to confirm the therapeutic value of these agents in the treatment of increased pulse pressure and arterial stiffness.

Antihypertensive Agents↗

Bone brittleness varies with genetic background in A/J and C57BL/6J inbred mice.

The contribution of genetic and environmental factors to variations in bone quality are understood poorly. We tested whether bone brittleness varies with genetic background using the A/J and C57BL/6J inbred mouse strains. Whole bone four-point bending tests revealed a 70% decrease in postyield deflection of A/J femurs compared with C57BL/6J, indicating that A/J femurs failed in a significantly more brittle manner. Cyclic loading studies indicated that A/J femurs accumulated damage differently than C57BL/6J femurs, consistent with their increased brittleness. Differences in matrix composition also were observed between the two mouse strains. A/J femurs had a 4.5% increase in ash content and an 11.8% decrease in collagen content. Interestingly, a reciprocal relationship was observed between femoral geometry and material stiffness; this relationship may have contributed to the brittle phenotype of A/J femurs. A/J femurs are more slender than those of C57BL/6J femurs; however, their 47% smaller moment of inertia appeared to be compensated by an increased tissue stiffness at the expense of altered tissue damageability. Importantly, these differences in whole bone mechanical properties between A/J and C57BL/6J femurs could not have been predicted from bone mass or density measures alone. The results indicated that bone brittleness is a genetically influenced trait and that it is associated with genetically determined differences in whole bone architecture, bone matrix composition, and mechanisms of cyclical damage accumulation.

Animals↗

Sacrificial bonds and hidden length dissipate energy as mineralized fibrils separate during bone fracture.

Properties of the organic matrix of bone as well as its function in the microstructure could be the key to the remarkable mechanical properties of bone. Previously, it was found that on the molecular level, calcium-mediated sacrificial bonds increased stiffness and enhanced energy dissipation in bone constituent molecules. Here we present evidence for how this sacrificial bond and hidden length mechanism contributes to the mechanical properties of the bone composite, by investigating the nanoscale arrangement of the bone constituents and their interactions. We find evidence that bone consists of mineralized collagen fibrils and a non-fibrillar organic matrix, which acts as a 'glue' that holds the mineralized fibrils together. We believe that this glue may resist the separation of mineralized collagen fibrils. As in the case of the sacrificial bonds in single molecules, the effectiveness of this mechanism increases with the presence of Ca2+ ions.

Animals↗

Alterations in the mechanical properties of the human chondrocyte pericellular matrix with osteoarthritis.

In articular cartilage, chondrocytes are surrounded by a pericellular matrix (PCM), which together with the chondrocyte have been termed the "chondron." While the precise function of the PCM is not know there has been considerable speculation that it plays a role in regulating the biomechanical environment of the chondrocyte. In this study, we measured the Young's modulus of the PCM from normal and osteoarthritic cartilage using the micropipette aspiration technique, coupled with a newly developed axisymmetric elastic layered half-space model of the experimental configuration. Viable, intact chondrons were extracted from human articular cartilage using a new microaspiration-based isolation technique. In normal cartilage, the Young's modulus of the PCM was similar in chondrons isolated from the surface zone (68.9 +/- 18.9 kPa) as compared to the middle and deep layers (62.0 +/- 30.5 kPa). However, the mean Young's modulus of the PCM (pooled for the two zones) was significantly decreased in osteoarthritic cartilage (66.5 +/- 23.3 kPa versus 41.3 +/- 21.1 kPa, p < 0.001). In combination with previous theoretical models of cell-matrix interactions in cartilage, these findings suggest that the PCM has an important influence on the stress-strain environment of the chondrocyte that potentially varies with depth from the cartilage surface. Furthermore, the significant loss of PCM stiffness that was observed in osteoarthritic cartilage may affect the magnitude and distribution of biomechanical signals perceived by the chondrocytes.

Adult↗

Possible role of decorin glycosaminoglycans in fibril to fibril force transfer in relative mature tendons--a computational study from molecular to microstructural level.

Experimental studies on immature tendons have shown that the collagen fibril net is discontinuous. Manifold evidences, despite not being conclusive, indicate that mature tissue is discontinuous as well. According to composite theory, there is no requirement that the fibrils should extend from one end of the tissue to the other; indeed, an interfibrillar matrix with a low elastic modulus would be sufficient to guarantee the mechanical properties of the tendon. Possible mechanisms for the stress-transfer involve the interfibrillar proteoglycans and can be related to the matrix shear stress and to electrostatic non-covalent forces. Recent studies have shown that the glycosaminoglycans (GAGs) bound to decorin act like bridges between contiguous fibrils connecting adjacent fibril every 64-68 nm; this architecture would suggest their possible role in providing the mechanical integrity of the tendon structure. The present paper investigates the ability of decorin GAGs to transfer forces between adjacent fibrils. In order to test this hypothesis the stiffness of chondroitin-6-sulphate, a typical GAG associated to decorin, has been evaluated through the molecular mechanics approach. The obtained GAG stiffness is piecewise linear with an initial plateau at low strains (<800%) and a high stiffness region (3.1 x 10(-11)N/nm) afterwards. By introducing the calculated GAG stiffness in a multi-fibril model, miming the relative mature tendon architecture, the stress-strain behaviour of the collagen fibre was determined. The fibre incremental elastic modulus obtained ranges between 100 and 475 MPa for strains between 2% and 6%. The elastic modulus value depends directly on the fibril length, diameter and inversely on the interfibrillar distance. In particular, according to the obtained results, the length of the fibril is likely to play the major role in determining stiffness in mature tendons.

Animals↗

Forces on adhesive contacts affect cell function.

Cellular forces acting on the adhesive contacts made with the extracellular matrix (ECM) contribute significantly to cell shape, viability, signal transduction and motility. In the past two years, research has determined how cell spreading influences cell viability as well as cytoskeletal organization. The cytoskeleton generates a level of tension against the ECM that is proportional to ECM stiffness. The strength of this tension exerted against the ECM affects the migratory speed of the cell.

Adhesiveness↗

Cell type-specific response to growth on soft materials.

Many cell types respond to forces as acutely as they do to chemical stimuli, but the mechanisms by which cells sense mechanical stimuli and how these factors alter cellular structure and function in vivo are far less explored than those triggered by chemical ligands. Forces arise both from effects outside the cell and from mechanochemical reactions within the cell that generate stresses on the surface to which the cells adhere. Several recent reviews have summarized how externally applied forces may trigger a cellular response (Silver FH and Siperko LM. Crit Rev Biomed Eng 31: 255-331, 2003; Estes BT, Gimble JM, and Guilak F. Curr Top Dev Biol 60: 91-126, 2004; Janmey PA and Weitz DA. Trends Biochem Sci 29: 364-370, 2004). The purpose of this review is to examine the information available in the current literature describing the relationship between a cell and the rigidity of the matrix on which it resides. We will review recent studies and techniques that focus on substrate compliance as a major variable in cell culture studies. We will discuss the specificity of cell response to stiffness and discuss how this may be important in particular tissue systems. We will attempt to link the mechanoresponse to real pathological states and speculate on the possible biological significance of mechanosensing.

Animals↗

Effect of recombinant human osteogenic protein-1 on the healing of a freshly closed diaphyseal fracture.

Osteogenic protein-1 (OP-1), or bone morphogenetic protein-7, is an osteoinductive morphogen that is involved in embryonic skeletogenesis and in bone repair. In bone defect models without spontaneous healing, local administration of recombinant human OP-1 (rhOP-1) induces complete healing. To investigate the ability of rhOP-1 to accelerate normal physiologic fracture healing, an experimental study was performed. In 40 adult female goats a closed tibial fracture was made, stabilized with an external fixator, and treated as follows: (1) no injection; (2) injection of 1 mg rhOP-1 dissolved in aqueous buffer; (3) injection of collagen matrix; and (4) injection of 1 mg rhOP-1 bound to collagen matrix. The test substances were injected in the fracture gap under fluoroscopic control. At 2 and 4 weeks, fracture healing was evaluated with radiographs, three-dimensional computed tomography (CT), dual-energy X-ray absorptiometry, biomechanical tests, and histology. At 2 weeks, callus diameter, callus volume, and bone mineral content at the fracture site were significantly increased in both rhOP-1 groups compared with the no-injection group. As signs of accelerated callus maturation, bending and torsional stiffness were higher and bony bridging of the fracture gap was observed more often in the group with rhOP-1 dissolved in aqueous buffer than in uninjected fractures. Treatment with rhOP-1 plus collagen matrix did not result in improved biomechanical properties or bony bridging of the fracture gap at 2 weeks. At 4 weeks there were no differences between groups, except for a larger callus volume in the rhOP-1 plus collagen matrix group compared with the control groups. All fractures showed an advanced stage of healing at 4 weeks. In conclusion, the healing of a closed fracture in a goat model can be accelerated by a single local administration of rhOP-1. The use of a carrier material does not seem to be crucial in this application of rhOP-1.

Absorptiometry, Photon↗

Fibronectin matrix polymerization increases tensile strength of model tissue.

The composition and organization of the extracellular matrix (ECM) contribute to the mechanical properties of tissues. The polymerization of fibronectin into the ECM increases actin organization and regulates the composition of the ECM. In this study, we examined the ability of cell-dependent fibronectin matrix polymerization to affect the tensile properties of an established tissue model. Our data indicate that fibronectin polymerization increases the ultimate strength and toughness, but not the stiffness, of collagen biogels. A fragment of fibronectin that stimulates mechanical tension generation by cells, but is not incorporated into ECM fibrils, did not increase the tensile properties, suggesting that changes in actin organization in the absence of fibronectin fibril formation are not sufficient to increase tensile strength. The actin cytoskeleton was needed to initiate the fibronectin-induced increases in the mechanical properties. However, once fibronectin-treated collagen biogels were fully contracted, the actin cytoskeleton no longer contributed to the tensile strength. These data indicate that fibronectin polymerization plays a significant role in determining the mechanical strength of collagen biogels and suggest a novel mechanism by which fibronectin can be used to enhance the mechanical performance of artificial tissue constructs.

Actins↗

Characterization of chronic vocal fold scarring in a rabbit model.

The purpose of the current study was to assess the histologic and rheologic properties of the scarred vocal fold lamina propria during a chronic phase of wound repair in a rabbit model. Eighteen rabbit larynges were scarred using a procedure that involved stripping the vocal fold lamina propria down to the thyroarytenoid muscle, using 3-mm microforceps. The approximate dimension of injury to the vocal fold was 3 x 1.5 x 0.5 mm [length x width x depth]. At 6 months postoperatively, histologic analysis of the scarred and control lamina propria in eight of these rabbits was completed for collagen, procollagen, elastin, and hyaluronic acid. Compared with control samples, scarred tissue samples revealed fragmented and disorganized elastin fibers. Additionally, collagen was significantly increased, organized, and formed thick bundles in the scarred vocal fold lamina propria. Measurements of the viscoelastic shear properties of the scarred and control lamina propria in the remaining 10 rabbits revealed increased elastic shear modulus (G') in 8 of 10 scarred samples and increased dynamic viscosity (eta') in 9 of 10 scarred samples. Although rheologic differences were not statistically significant, they revealed that on average, scarred samples were stiffer and more viscous than the normal controls. Histologic data are interpreted as indicating that by 6 months postinjury, the scarred rabbit vocal fold has reached a mature phase of wound repair, characterized by an increased, organized, and thick bundle collagen matrix. Rheologic data are interpreted as providing support for the potential role of increased, thick bundle collagen, and a disorganized elastin network on shear stiffness and dynamic viscosity in the chronic vocal fold scar. Based on these results, a 6-month postoperative time frame is proposed for future studies of chronic vocal fold scarring using the rabbit animal model.

Animals↗

Cancellous bone repair using bovine trabecular bone matrix particulates.

At 5 and 15 weeks post-surgery, biomechanical and histological analyses of cancellous bone defects filled with the bovine trabecular bone matrix (BBM) and hydroxyapatite (Hap) particulates of dimensions 106-150 microm were investigated. It was observed that at 5 weeks post-surgery the stiffness properties of the BBM filled defects were significantly higher than those observed in the Hap filled defects (p < 0.01) but comparable to those recorded in intact cancellous bone from the same anatomical position. Histologically, no significant differences were observed in the percentage of new bone contact with the particles. The biomechanical properties of the Hap filled defects mirrored those in intact cancellous bone only at 15 weeks post-surgery. BBM particles thus appeared to accelerate the early healing of osteotomies. It is therefore suggested that particles of this bioceramic be the subject of intense research for more usage in both periodontal osseous defects and orthopaedic fractures.

Animals↗

Acoustoelastic effect in stressed heterostructures.

Mechanical stresses influence the phase velocity of acoustic waves, known as the AE (acoustoelastic) effect. In order to calculate the AE effect of biaxially stressed layered systems, we extended the transfer matrix method for acoustic wave propagation by considering the change of the density, the influence of residual stress, and the modification of the elastic stiffness tensor by residual strain and by third-order constants. The generalized method is applied to the calculation of the angular dispersion of the AE effect for transverse bulk modes and surface acoustic waves on Ge(001). Our calculations reveal that the AE effect significantly depends on the propagation direction and can even change sign. The maximal velocity change occurs for transversally polarized waves propagating parallel to the [110] direction. For the layered Ge/Si(001) system, the AE effect is investigated for Love modes propagating in the [100] and [110] directions. The AE effect increases rapidly with increasing layer thickness and almost reaches its maximal value when the wave still penetrates into the unstressed substrate.

Journal Article↗