Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MITRAL VALVE STENOSIS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Mid-term results of mitral valve replacement combined with chordae tendineae replacement in patients with mitral stenosis.

BACKGROUND AND AIMS OF THE STUDY: Although many studies have found that preservation of the continuity between the mitral annulus and the papillary muscles during mitral valve replacement improves postoperative left ventricular performance in patients with mitral regurgitation, much less research has been done in this respect in patients with mitral stenosis. We reviewed our experience with mitral valve replacement combined with chordae tendineae replacement in 29 patients with mitral disease, 26 of whom had mitral stenosis. METHODS: During mitral valve replacement, continuity between the papillary muscle and annulus was restored with expanded polytetrafluoroethylene (ePTFE) mattress sutures, which were threaded into the compact portion of each papillary muscle and placed at the 2, 4, 8 and 10 o'clock positions in the mitral annulus. Postoperatively, the patients were followed by echocardiographic assessment and exercise (stress) radionuclide angiography testing. The stress test results were compared with those in patients who had undergone traditional mitral valve replacement, and also those in normal people. RESULTS: There were no hospital deaths, complications, or cardiac deaths or events during a median follow up of two-and-a-half years. Echocardiography showed no postoperative cardiac dilatation. The stress tests found no significant differences between the ejection fraction in mitral stenosis patients who underwent conventional mitral valve replacement and in those who had valve replacement combined with ePTFE chordae tendineae replacement. CONCLUSIONS: A direct advantage of chordae-preserving mitral valve replacement over conventional replacement with respect to postoperative global left ventricular performance in patients with mitral valve stenosis has not been demonstrated. However, postoperative regional left ventricular contraction in patients with mitral stenosis has been observed to be better among those who have undergone the chordae-preserving procedure. Additional investigations are needed to elucidate the effects of this procedure in mitral stenosis, but we believe that the technique improves left ventricular performance and may decrease the risk of left ventricular rupture.

Adult↗

[Doppler measurement of transvalvular gradients. Simultaneous Doppler-catheterization recordings on 78 patients].

Several studies have demonstrated the value of Doppler ultrasound as a means of measuring gradients across cardiac valves. However, in view of sudden variations in cardiac output gradients should be measured simultaneously by Doppler and catheterization in order to validate the former method and determine its accuracy. We conducted a prospective study with simultaneous recordings in 78 patients with aortic valve stenosis (33) or mitral valve stenosis (19) or cardiac valve prosthesis (26). Mean age of the patients was 55 +/- 14 years, and 50% of them were male. Subjects with pure or predominant regurgitation were excluded from the study. In the whole of the population studied, correlation between Doppler ultrasound and haemodynamics was very good with r = 0.98, p less than 0.001 for maximum gradient and r = 0.96, p less than 0.001 for mean gradient. The perfect simultaneity of the haemodynamic and ultrasonic recordings was confirmed by comparing the duration of gradients measured by the two methods (r = 0.996, p less than 0.001). There also was very close correlation between ultrasounds and catheter in patients with mitral stenosis (maximum gradient r = 0.98, p less than 0.001; mean gradient r = 0.97, p less than 0.001). Mean Doppler-catheter differences were not significant, and no underestimation by Doppler reached or exceeded 5 mmHg. Correlations were also satisfactory in patients with aortic stenosis (maximum gradient r = 0.97, p less than 0.01; mean gradient r = 0.90, p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve Stenosis↗

Mitral stenosis after mitral valve repair using the duran flexible annuloplasty ring for degenerative mitral regurgitation.

The case is presented of a 47-year-old woman who had undergone mitral valve repair using the Duran annuloplasty ring four years earlier, and who was diagnosed with mitral stenosis owing to fibrous tissue overgrowth. In this patient, dense whitish fibrous tissue covered the annuloplasty ring and extended onto both leaflets of the mitral valve, narrowing its orifice and rendering the leaflets stiff and immobile. The pannus covering the mitral valve could not be stripped off without damaging the leaflets, making mitral valve replacement necessary. Mitral valve replacement with a St. Jude Medical mechanical heart valve prosthesis was successfully performed, and no major perioperative complications were encountered.

Female↗

Effect of severe pulmonary hypertension on the calculation of mitral valve area in patients with mitral stenosis.

We studied 50 consecutive patients with mitral valve stenosis (MS) by cardiac catheterization and Doppler echocardiography to assess whether the presence of severe pulmonary hypertension affected the calculation of valve area by Doppler pressure half-time method and by the Gorlin formula using pulmonary capillary wedge pressure as an index of left atrial pressure. Patients with severe mitral regurgitation were excluded. In patients with pulmonary artery systolic pressure (PAS) less than 70 mm Hg (n = 33), there was good correlation between the mitral valve area derived from Doppler echocardiography and from cardiac catheterization (r = 0.85). However, in patients with PAS greater than or equal to 70 mm Hg (n = 17), this correlation was not as good (r = 0.57). In these 17 patients, the Gorlin formula tended to underestimate the valve orifice area (mean valve area 0.85 +/- 0.49 and 1.06 +/- 0.46 cm2 by catheterization and by Doppler respectively, p = NS). Direct measurement of the valve area by two-dimensional echocardiography was possible in 12 of the 17 patients and correlated well with Doppler values (r = 0.91). Hence in the presence of severe pulmonary hypertension, Doppler pressure half-time estimation of mitral valve area is more accurate than is catheterization-derived valve area, using the wedge pressure and the Gorlin formula.

Acute Disease↗

The effect of pentoxifylline on the lung during cardiopulmonary bypass.

Cardiopulmonary bypass (CPB) produces an inflammatory response due to the interaction of blood with a foreign body surface. The lungs are most affected by this inflammatory response. Pentoxifylline (PTX), a phosphodiesterase inhibitor and an inhibitor of leukocyte activation, is used to minimize damage in lungs where leukocytes play an important role. Twenty patients with mitral valve stenosis with planned mitral valve surgery were included in the study. The ten patients receiving pentoxifylline (PTX group) were administered 400 mg PTX orally TID for 3 days preoperatively and, following anesthetic induction, a 300 mg PTX infusion was given. The ten patients receiving no PTX were the control group (CT). Platelet and leukocyte counts, mean pulmonary arterial pressure (mPAP), pulmonary capillary wedge pressure (PCWP), cardiac index (CI), pulmonary vascular resistance (PVR), alveolar-arterial PO2 gradient (AaDO2) were measured just before and after CPB, and 2 h postoperatively. The number of the leukocytes increased in the blood samples drawn 15 min after CPB in both groups and 2 h postoperatively showed no statistical change. The number of platelets had decreased significantly at the end of the CPB in both groups and, 2 h postoperatively, there was a further decrease in the blood count in the control group (P < 0.05). There was no significant difference in either the preoperative or postoperative PAP, PAWP, and CI. Pulmonary vascular resistance increased in both groups following the CPB (CT, before: 136 +/- 44, after: 177 +/- 94 dyne. sec.cm-5; PTX, before: 151 +/- 82, after 182 +/- 43 dynes.sec.cm-5). Two hours postoperatively, a considerable increase continued in the control group (CT 219 +/- 170 dynes.sec. cm-5), while there was an insignificant increase in the PTX group (PTX 193 +/- 51 dynes.sec.cm-5) (P < 0.05). The alveolar-arterial PO2 gradient increased after the CPB in both groups but a moderate decrease was observed 2 h postoperatively. In lung biopsy specimens taken before and after the CPB, there was marked leukocyte sequestration in the control group, whereas the number of leukocytes was seen to be insignificant in the PTX group (P < 0.005). This dosage regimen of PTX inhibits the postoperative increase in PVR and greatly minimized leukocyte sequestration in the lung due to CPB.

Adult↗

Inaccurate noninvasive mitral valve area calculation during pregnancy.

OBJECTIVE: To compare two different Doppler echocardiographic techniques for the assessment of the transmitral area in pregnant patients with native mitral valve stenosis or prosthetic mitral valves. METHODS: Eight consecutive gravid women with prosthetic mitral valves or obstructive native mitral valve disease were evaluated using both the pressure half-time and the continuity equation Doppler echocardiographic methods. Heart rate, cardiac output, and transmitral valve gradient and area were calculated. These studies were repeated postpartum in five women. Differences between the two methods were assessed by characterizing the absolute differences between the mean and standard deviation and by paired t tests. Linear regression analysis was also applied. RESULTS: For the five women who also had postpartum studies, antepartum data were similar to those of the full set of eight patients. Postpartum heart rate, cardiac output, and transvalvular gradient were lower than antepartum measurements. Calculations using the continuity equation yielded comparable antepartum and postpartum estimates of transmitral areas (1.31 +/- 0.41 versus 1.32 +/- 0.44 cm2, respectively, r = 0.96). These estimates were also consistent with the initial clinical presentation. In contrast, antepartum transmitral valve areas calculated using the pressure half-time technique (2.67 +/- 0.61 cm2) were markedly higher than postpartum (1.94 +/- 0.58 cm2). The correlation between the estimates of antepartum valve area given by the two methods was not statistically significant (r = 0.02). In contrast, there was excellent postpartum correlation of transmitral area between the methods (r = 0.99), despite a significant difference (P < .001) in the transmitral area calculated with each technique. CONCLUSIONS: The results indicate that Doppler echocardiographic estimates of the transvalvular area using the continuity equation technique during pregnancy are valid. In contrast, estimates of area using the pressure half-time technique in pregnant patients are dubious and could result in life-threatening consequences.

Adult↗

[Preservation of the entire mitral subvalvular apparatus during mitral valve replacement in patients with mitral stenosis].

OBJECTIVE: To evaluate the surgical technique and the effect of preservation of the entire mitral subvalvular apparatus during mitral valve replacement (MVR) in patients with mitral stenosis. METHODS: MVR was performed on 56 patients with mitral stenosis. Of them, 11 had complete preservation of the entire mitral subvalvular apparatus (group A) with the technique of preservation of 'button-shaped' transplantation, 25 had the preservation of the posterior leaflet only (group B), and the other 20 underwent the conventional MVR (group C). Pre- and postoperative hemodynamic parameters were measured to determine the left ventricular performance. Echocardiography was performed preoperatively, at the time of discharge, and 3 to approximately 6 months postoperatively to determine the dimensions and ejection function. RESULTS: Cardiac index, stroke volume index and left ventricular stroke work index postoperatively in group A were better than those in group B and C (P < 0.05). Echocardiographic measurements postoperatively showed the increase of LVESD, LVEDD in group B and C, but a better LVL and LVFS in group A (P < 0.05), and LVEF was more pronounced in group A (P < 0.05). There appeared a long cross-clamp time in group A, but the total CPB time was not significant among the three groups. CONCLUSION: The surgical skills of preservation with 'button-shaped' transplantation may be a practical choice for patients with mitral stenosis. The preservation of entire mitral subvalvular apparatus improves the left ventricular functions after MVR in patients with mitral valve stenosis.

Adolescent↗

[Segmental analysis of the movement of the posterior mitral valve in mitral stenosis].

We have analyzed independently, both, early diastolic and end diastolic (A wave) movements of the posterior mitral leaflet in 302 cases of mitral stenosis with sinus rhythm, as well as in a control group of 100 subjects without mitral stenosis. Studied patients were separated into two groups: 275 that were not treated surgically, and 27 studied after mitral commisurotomy. We described 4 patterns of posterior mitral leaflet early diastolic movement, and 3 patterns of A wave motion. Only those patterns that showed anterior drift of the studied segment of the posterior mitral leaflet, were considered diagnostic of mitral stenosis. The sensitivity found was 49% for the anterior early diastolic movement; 89,5% for the anterior A wave, and 95,3% for both signs considered together. The specificity was 99% for anterior A wave, with a predictive value of 99,6%. When surgical and non surgical groups were compared, the absence of anterior drift in early diastole in the former group, showed to have statistical significance when the Chi square test was employed, while A wave pattern (anterior drift) did not show any difference between both groups. It is concluded that the most sensitive and specific sign for M-mode echocardiagraphic diagnosis of mitral stenosis in patients with sinus rhythm is the anterior drift of posterior mitral leaflet's A wave.

Diastole↗

The old-age heart: normal aging changes which can produce or mimic cardiac disease.

The elderly segment of our society may triple by the year 2050. Specific cardiovascular data on the normal aging heart will be needed to provide proper medical and surgical therapy for this patient group. This report reviews normal aging changes of the very elderly heart. Expected or normal aging changes include brown atrophy of the myocardium, increased subepicardial fat, focal amyloid deposits, sigmoid-shaped ventricular septum, and calcific deposits in the aortic valve, mitral annulus and epicardial coronary arteries. Certain normal aging changes may produce clinical heart disease: aortic valve calcium (aortic stenosis), mitral valve annular calcium (mitral stenosis), amyloid deposits (amyloid heart disease). Certain normal aging changes may mimic heart disease: sigmoid-shaped ventricular septum (hypertrophic cardiomyopathy), mitral leaflet "buckling" (floppy mitral valve).

Aged↗