Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Magnetization process of single molecule magnets at low temperatures.

We show that correlations established before quenching to very low temperatures later drive the magnetization process of systems of single molecule magnets, after a magnetic field is applied at t=0. We also show that in simple cubic lattices m proportional, variant sqrt[t], as observed in Fe8, but only for 1+2log((10)(h(d)/h(w)) time decades, where h(d) is a nearest neighbor dipolar magnetic field and a spin reversal can occur only if the field on it is within (-h(w),h(w)). However, the sqrt[t] behavior is not universal. For bcc and fcc lattices, m proportional, variant t(p), but p approximately 0.7. The value to which m finally levels off is also given.

Journal Article↗

Symmetry of magnetic quantum tunneling in single molecule magnet Mn12-acetate.

The symmetry of magnetic quantum tunneling has been studied in the prototype single molecule magnet Mn12-acetate using a micro-Hall effect magnetometer and superconducting high field vector magnet system. An average crystal fourfold symmetry is shown to be due to local molecular environments of twofold symmetry that are rotated by 90 degrees with respect to one another, confirming that disorder which lowers the molecule symmetry is as important to magnetic quantum tunneling. We have studied a subset of these lower (twofold) site symmetry molecules and present evidence for a Berry phase effect consistent with a local twofold symmetry.

Journal Article↗

Magnetic long-range order induced by quantum relaxation in single-molecule magnets.

Can magnetic interactions between single-molecule magnets (SMMs) in a crystal establish long-range magnetic order at low temperatures deep in the quantum regime, where the only electron spin fluctuations are due to incoherent magnetic quantum tunneling (MQT)? Put inversely: can MQT provide the temperature dependent fluctuations needed to destroy the ordered state above some finite T(c), although it should basically itself be a T-independent process? Our experiments on two novel Mn4 SMMs provide a positive answer to the above, showing at the same time that MQT in the SMMs has to involve spin-lattice coupling at a relaxation rate equaling that predicted and observed recently for nuclear-spin-mediated quantum relaxation.

Journal Article↗

Magnetism and magnetic isomers in free chromium clusters.

We have used the Stern-Gerlach deflection technique to study magnetism in chromium clusters of 20-133 atoms at temperatures between 60 and 100 K. We observe that these clusters have large magnetic moments and respond superparamagnetically to applied magnetic fields. Using superparamagnetic theory, we have determined the moment per atom for each cluster size and find that it often far exceeds the moment per atom present anywhere in the bulk antiferromagnetic lattice. Remarkably, our cluster beam contains two magnetically distinguishable forms of each cluster size with > or =34 atoms. We attribute this observation to structural isomers.

Journal Article↗

Magnetization of nanoparticle systems in a rotating magnetic field.

The investigation of a sizable thermal enhancement of magnetization is put forward for uniaxial ferromagnetic nanoparticles that are placed in a rotating magnetic field. We elucidate the nature of this phenomenon and evaluate the resonant frequency dependence of the induced magnetization. Moreover, we reveal the role of magnetic dipolar interactions, point out potential applications, and reason the feasibility of an experimental observation of this effect.

Journal Article↗

Soft X-ray resonant magnetic scattering from a Ni layer with modulated magnetic anisotropy.

Soft X-ray resonant magnetic scattering studies on a magnetically modulated, but nominally chemically homogenous, 5 nm Ni layer in a Cu/Ni/Cu/Co/NiO/GaAs(110) system are reported. It was possible to estimate the main chemical structure of the sample on the basis of the results from specular reflectivity and rocking scans, probing the scattering vector components in the perpendicular and in-plane direction to the Ni wires, respectively. The magnetic scattering using polarized X-rays demonstrates the magnetic modulation of the Ni layer.

Journal Article↗

Magnetic measurement system for high-field magnets.

One of the main principles in electrodynamics, the change of magnetic field flux inducing an EMF in a wire coil, is applied for magnetic measurement. A scheme and the main parameters of the magnetic measurement system are described. The system was successfully used for magnetic measurement of a 7 T superconducting wiggler for LSU CAMD; results are presented.

Journal Article↗

Transcranial magnetic stimulation: normal values of magnetic motor evoked potentials in 84 normal horses and influence of height, weight, age and sex.

REASONS FOR PERFORMING STUDY: Cervical spinal cord dysfunction is a common problem in equine medicine and the currently available tests give no objective information about the functionality of the nervous tracts. Therefore, transcranial magnetic stimulation (TMS) was performed in 84 healthy horses of different height in order to have an objective measure for the integrity of the descending motor tracts in normal horses. OBJECTIVES: To obtain reference values for onset latency and peak-to-peak amplitude of magnetic motor evoked potentials (MMEPs) and to evaluate the possible effect of height, age and gender on the neurophysiological measures. METHODS: All horses were sedated and stimulated transcranially by using a magnetic coil placed on the forehead. The stimulator triggered the sweep of an electromyogram machine that recorded MMEPs bilaterally from needle electrodes in the extensor carpi radialis and cranial tibial muscles. In that way, it was possible to measure latency between stimulus and onset of response. RESULTS: A significant difference was found between recordings made in the fore- and hindlimbs; MMEPs recorded in the front legs had a shorter onset latency and higher peak-to-peak amplitude. Mean +/- s.d. normal values for onset latency of 19.32 +/- 2.50 and 30.54 +/- 5.28 msecs and peak-to-peak amplitude values of 9.54 +/- 3.73 and 6.62 +/- 3.62 mV were obtained for extensor carpi radialis and cranial tibial muscles, respectively. The left-to-right difference in onset latency and peak-to-peak amplitude was not significant. In the same horse, differences up to 0.82 and 1.53 msecs for the extensor carpi radialis and cranial tibial muscles, respectively, lie within the 95% confidence limit and are considered normal. In contrast to onset latency, peak-to-peak amplitude showed a very large intra- and interindividual variability, even in the same muscle. To reduce the variability and predict normal values of new individual cases, influence of height, weight, age and sex on the MMEPs were determined. No significant effects of sex were observed on onset latency and peak-to-peak amplitude. The age of the horse had only a small but significant effect on peak-to-peak amplitude, with larger responses in older horses. Height at the withers and weight of the horse, parameters that strongly correlate with the size of the horse, had an important significant influence on onset latency but not on peak-to-peak amplitude. The age of the horse and height at the withers were used to predict peak-to-peak amplitude and onset latency, respectively, in normal horses. CONCLUSIONS AND POTENTIAL RELEVANCE: TMS is an excellent addition to the few tools we have for noninvasive imaging of the equine nervous system. Magnetically evoked potentials are highly reproducible and recent advances suggest that the applications of TMS in horses will continue to grow rapidly.

Age Factors↗

Proton magnetic resonance spectroscopic imaging and magnetic resonance imaging volumetry in the lateralization of temporal lobe epilepsy: a series of 100 patients.

Surgery is a safe and effective treatment for drug-resistant temporal lobe epilepsy (TLE). However, bilateral electroencephalographic (EEG) abnormalities are frequently present, making presurgical lateralization difficult. New magnetic resonance (MR) techniques can help; proton magnetic resonance spectroscopic imaging (MRSI) can detect and quantify focal neuronal damage or dysfunction based on reduced signals from the neuronal marker N-acetylaspartate, and magnetic resonance imaging (MRI)-based measurements of amygdala-hippocampal volumes (MRIVol) can improve the detection of atrophy of these structures. We performed proton MRSI and MRIVol in 100 consecutive patients with medically intractable TLE to determine how well these techniques agreed with the lateralization by extensive EEG investigation. We found that the EEG, MRSI, and MRIVol findings were highly concordant. The MRSI was abnormal in 99 of 100 patients (bilateral in 54%). The MRIVol was abnormal in 86 of 98 patients (bilateral in 28%). We obtained lateralization in 83% of patients using MRIVol alone, in 86% using MRSI alone, and in 90% by combining MRSI and MRIVol (vs 93% lateralization by EEG). MRSI was abnormal in 12 patients with normal MRIVol. The combination of proton MRSI and MRIVol can lateralize TLE accurately and noninvasively in the great majority of patients. By reducing reliance on EEG, these imaging techniques could reduce prolonged presurgical evaluation and make seizure surgery available to more patients.

Adult↗

Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral test battery were compared in four 1-hr sessions with and without exposure to magnetic fields, and with and without additional movements. Adverse effects were found for hand coordination (-4%, P < 0.05; Pursuit Aiming II) and near visual contrast sensitivity (-16% and -15%, P < 0.10; Vistech 6000). The results from the remaining tests were inconclusive due to a strong learning effect. No additional effect from gradient fields was detected. The results indicate that working near a 1.5 Tesla MRI system may lead to neurobehavioral effects. Further research is recommended, especially in members of operating teams using interactive MRI systems.

Adult↗

Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields.

At high magnetic fields (7 and 8.4 T), water proton magnetic resonance images of brains of live mice and rats under pentobarbital anesthetization have been measured by a gradient echo pulse sequence with a spatial resolution of 65 x 65-microns pixel size and 700-microns slice thickness. The contrast in these images depicts anatomical details of the brain by numerous dark lines of various sizes. These lines are absent in the image taken by the usual spin echo sequence. They represent the blood vessels in the image slice and appear when the deoxyhemoglobin content in the red cells increases. This contrast is most pronounced in an anoxy brain but not present in a brain with diamagnetic oxy or carbon monoxide hemoglobin. The local field induced by the magnetic susceptibility change in the blood due to the paramagnetic deoxyhemoglobin causes the intra voxel dephasing of the water signals of the blood and the surrounding tissue. This oxygenation-dependent contrast is appreciable in high field images with high spatial resolution.

Animals↗

Magnetic resonance imaging measurement of volume magnetic susceptibility using a boundary condition.

A magnetic resonance imaging method is described for measuring the magnetic susceptibility difference between two homogeneous macroscopic compartments in contact with each other. A boundary condition is derived for the interface of the two compartments. This boundary condition predicts that across the interface there is a resonant frequency jump, which is a function of interfacial orientation relative to B0 field and the difference in susceptibility of the two sides. Based on this relationship, the magnetic susceptibility difference between two materials can be obtained from MR gradient echo imaging using signals from both sides in the vicinity of the boundary. This method is demonstrated by solution phantom experiments.

Algorithms↗

Magnetic field gradient system for nuclear magnetic resonance microimaging.

In this study we present an orthogonal magnetic field gradient system for nuclear magnetic resonance (NMR) microimaging applications. The construction details are given for a prototype assembly for proton microscopy inside a 50-mm vertical bore magnet, which is designed to fit into a commercial 300-MHz NMR probe. This system has been used to acquire images of the human spinal cord in vitro. Its performance has been evaluated and compared to that predicted by computer simulation.

Humans↗

Magnetic forces on orthodontic wires in high field magnetic resonance imaging (MRI) at 3 tesla.

BACKGROUND: In a previous investigation we reported on magnetic forces in the static magnetic field of a 1.5 Tesla MRI system. The aim of the present investigation was to assess forces on orthodontic wires in a high field strength MRI system at 3 Tesla. MATERIALS AND METHODS: Thirty-two different orthodontic wires (21 archwires, eight ligature wires and three retainer wires) were investigated in a 3 Tesla high field strength MRI system (Intera, Philips Medical Systems, Best, The Netherlands). Translational forces were measured by the deflection angle test (ASTM F2052-02), and rotational forces assessed on a 5-point qualitative scale. RESULTS AND CONCLUSION: Translational forces ranged between 43.5 mN and 136.1 mN for retainer wires and between 0.6 mN (Noninium) and 208.4 mN (Orthos Stainless Steel) for steel archwires. Translational forces were up to 53.8 times as high as gravitational forces for retainer wires and up to 54.5 times as high for steel archwires, associated with marked rotational forces for the most part. Archwires manufactured from nickel-titanium, titanium-molybdenum and cobalt-chromium and different ligature wires showed no or negligible forces in the magnetic field. Carefully ligated wires should not present a risk due to translational and rotational forces in the high field MRI system at 3 Tesla.

Alloys↗

Agenesis of the horizontal segment of the left portal vein demonstrated by magnetic resonance imaging including phase-contrast magnetic resonance venography.

Two cases of agenesis of the horizontal segment of the left portal vein are reported. This very rare vascular anomaly probably corresponds to an embryological variation rather than to an obstruction of the left portal vein. In almost all cases liver ultrasonography is sufficient for identifying such vascular abnormalities. It shows a large aberrant vessel emerging from a right anterior segmental portal branch and running transversely in the quadrate lobe towards the teres ligamentum from which the portal supply to the left lobe arises. It is important to be able to recognize the magnetic resonance imaging features of this vascular variation, as magnetic resonance imaging may be the initial imaging study, and ultrasound may be technically challenging. To our knowledge, we present the first description of these features, including an enhanced gradient-echo T1-weighted sequence, a turbo spin-echo T2-weighted sequence with fat saturation, and a three-dimensional phase-contrast magnetic resonance portography.

Adult↗

Numerical analysis of the magnetic field for arbitrary magnetic susceptibility distributions in 3D.

This paper demonstrates a method to calculate the magnetic field distribution in and around a 3D object when it is magnetized by a strong homogeneous magnetic field. The numerical technique is based on the explicit finite difference method. The calculation method is validated against analytical solutions for a sphere. As an application cylinders with different ratios of lengths and diameter are studied.

Magnetic Resonance Imaging↗

Imaging focal reperfusion injury following global ischemia with diffusion-weighted magnetic resonance imaging and 1H-magnetic resonance spectroscopy.

The purpose of the study was to determine whether diffusion-weighted magnetic resonance imaging (DWI) could identify focal lesions that develop in ischemia-sensitive cerebral tissues during reperfusion following global brain ischemia. Localized 1H-Magnetic Resonance Spectroscopy (1H-MRS) measurements were also obtained to determine whether abnormal spectroscopic markers were associated with focal lesions and to define time correlations between DWI and metabolic changes. Brain diffusion-weighted magnetic resonance imaging measurements were made in a cat model of repetitive global cerebral ischemia and reperfusion. Five animals were exposed to three episodes of 10 min vascular occlusions at hourly intervals. Three animals were evaluated as controls. DWI, T2WI, and 1H-MRS data were acquired for up to 12 h. Transient focal DWI hyperintensity was detected in the hippocampus, basal ganglia, and cortical watershed areas. These focal abnormalities usually appeared during the final reperfusion and eventually spread to encompass all of the gray matter. Spectroscopic measurements demonstrated the expected elevation of the lactate signal intensity during vessel occlusion, which returned to normal during early reperfusion. A subsequent rise in the lactate signal occurred approximately 3-4 h after the beginning of the third reperfusion. This late lactate elevation occurred after focal hyperintensities were identified by DWI. No significant signal changes were seen in spectroscopic metabolites other than lactate. The study illustrates that DWI and 1H-MRS are sensitive to focal cerebral lesions that occur during reperfusion following global cerebral ischemia.

Animals↗

Improving automatic analysis of the electrocardiogram acquired during magnetic resonance imaging using magnetic field gradient artefact suppression.

The electrocardiogram (ECG) used for patient monitoring during magnetic resonance imaging (MRI) unfortunately suffers from severe artefacts. These artefacts are due to the special environment of the MRI. Modeling helped in finding solutions for the suppression of these artefacts superimposed on the ECG signal. After we validated the linear and time invariant model for the magnetic field gradient artefact generation, we applied offline and online filters for their suppression. Wiener filtering (offline) helped in generating reference annotations of the ECG beats. In online filtering, the least-mean-square filter suppressed the magnetic field gradient artefacts before the acquired ECG signal was input to the arrhythmia algorithm. Comparing the results of two runs (one run using online filtering and one run without) to our reference annotations, we found an eminent improvement in the arrhythmia module's performance, enabling reliable patient monitoring and MRI synchronization based on the ECG signal.

Algorithms↗