Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Laboratory Procedures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Serum trypsin inhibitory capacity and Pi phenotypes. I. Methods and control values.

Serum trypsin inhibitory capacity determinations are of considerable value in detecting genetically determined types of obstructive pulmonary disease and hepatic disease. These determinations must frequently be followed by determination of protease inhibitor (Pi) phenotype in order to confirm the diagnosis. Piphenotyping has been a specialized and time-consuming procedure, and suggested improvements in the methodology and technics may make it more generally applicable as a clinical laboratory procedure. The prevalence of phenotypes other than MM in a group of 700 control sera from blood donors is reported as a baseline to evaluate typically American populations of mixed ethnic and racial characteristics. There are suggestive differences in prevalences of S and Z genes relating to ethnic stock and racial groups. It is important when comparing the prevalences of S and Z genes in diseasedpopulations to use control groups of similar ethnic and racial compositions. Pi phenotyping is a necessary laboratory procedure in the diagnosis of certain forms of genetically determined chronic obstructive pulmonary disease and hepatic disease. The distributions of all serum protease inhibitory capacity values and those for S and Z Pi phenotypes are shown.

Adolescent↗

Efficient DNA database laboratory strategy for high through-put STR typing of reference samples.

DNA intelligence databases were installed successfully in various countries during the past few years. It is a general trend that laboratories performing STR analysis for DNA databases have to adjust to increased sample through-put, especially when dealing with a high number of reference samples. In contrast to routine forensic casework analysis, where samples of suspects and unknown samples are interpreted with regard to the specific circumstances of the case and are kept distinctly apart from other cases, DNA databases consist of single, primarily unlinked DNA profiles. Problems areas associated with the high number of anonymous DNA profiles are the risk of logistic errors, such as sample mix-up during the laboratory procedure, and the risk of typing errors during manual transcription of data and/or results. Thus, DNA databases clearly require new laboratory strategies to rise to the challenge. This paper presents an efficient automated laboratory strategy on the platform of a laboratory management information system (LIMS) with the Austrian DNA Intelligence Database as example. Two goals were tackled in particular: first, data safety by avoiding both manual interaction during critical laboratory steps (i.e. when DNA is transferred form one tube into another), and errors due to manual transcription of sample information and results. Secondly, efficient sample processing by automizing the laboratory procedure with the help of robotic instruments, thus, giving the DNA staff more time to analyze data.

Austria↗

A comparison of analytic procedures for measurement of fractional dextran clearances.

Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein contamination of 0.2% +/- 0.3%, whereas both 5% TCA and zinc sulfate deproteinization revealed a significantly higher remaining sample protein content (2.5% +/- 0.4% and 3.4% +/- 0.1%, respectively). Only zinc sulfate revealed incomplete deproteinization of urine samples (0.6% +/- 0.2%). Dextran recovery in plasma and urine supernatants was significantly lower after 5% TCA and zinc sulfate deproteinization when compared with 20% TCA deproteinization. Gel permeation chromatography (GPC) and high-performance liquid chromatography (HPLC) showed a variance of calibration smaller than 5% over 1 year. The use of 3 different sets of standard dextrans revealed significant differences in calibration. GPC and HPLC followed by anthrone assay showed a comparable variance in dextran concentration in plasma, from 3 to 6 nm (14% to 25%), whereas the variance in urine was lower for the GPC and anthrone assay, especially from 5.4 to 6 nm (23% to 43% versus 50% to 78%). HPLC and online refractometry showed the lowest variance of dextran concentration in plasma, from 3 to 6 nm (<4%), and in urine, from 3 to 5.2 nm (<7%), whereas it showed a higher variance in urine, from 5.4 to 6 nm, in comparison with GPC and HPLC with the anthrone assay. The GPC and anthrone assay revealed higher fractional dextran clearances in comparison with the HPLC and anthrone assay in healthy subjects (3 to 5.4 nm) as well as in patients with nondiabetic proteinuria (4.2 to 5.8 nm), and lower clearances in patients from 3 to 3.4 nm. The HPLC and anthrone assay revealed higher clearances in comparison with HPLC and online refractometry in healthy subjects (3.6 to 5.4 nm) and in patients (3.6 to 5.2 nm). The GPC and anthrone assay revealed characteristic differences in fractional dextran clearances between healthy subjects and patients. The HPLC and anthrone assay showed no significant differences between both groups, whereas HPLC and online refractometry showed only an increased clearance of dextrans from 4.6 to 5.2 nm in patients. Fractional clearances of dextran 5.6 nm as estimated by all 3 dextran assays were not significantly related to the fractional immunoglobulin G clearance or the immunoglobulin-to-albumin clearance index in our patients. Quantitative and qualitative differences in fractional dextran clearances may be induced by differences in laboratory procedures. We recommend sample preparation by 20% TCA deproteinization, frequent calibration with 1 set of dextran standards with low polydispersity, size-exclusion chromatography by GPC, and dextran detection by anthrone assay for optimal measurement of fractional dextran clearances. Even with such an approach, however, the variability in the measurement remains extremely high in the important range of dextrans greater than 5 nm.

Chromatography, Gel↗

Survey of physician practice behaviors related to diabetes mellitus in the U.S. Physician adherence to consensus recommendations.

OBJECTIVE: To summarize the frequency of physician adherence to consensus recommendations for prevention of diabetic complications. RESEARCH DESIGN AND METHODS: Survey data from a nationwide stratified probability sample of primary-care physicians were analyzed. Adherence to recommendations were reported by physician specialty, age-group, and type of diabetes treated. RESULTS: Adherence was high for eye exams, blood pressure measurements, neurological and circulatory exams, and laboratory procedures using blood. Adherence was low for examination of the teeth and gums, examination of the feet, and laboratory procedures involving the collection of urine. Internists generally had the highest adherence rates and pediatricians the lowest. Reported adherence decreased with physician age. Adherence was higher for the management of individuals with IDDM than for those with NIDDM. CONCLUSIONS: Recommendations for the care of diabetic individuals need to be more widely implemented. Recommendations targeted specifically to pediatricians may be necessary.

Adult↗

Calcium, phosphorus, and alkaline phosphatase values of elderly subjects.

OBJECTIVE: To determine if significant gender differences existed between subjects 65 years of age and older, with regard to calcium, phosphorus, and alkaline phosphatase levels. DESIGN: A retrospective chart review of laboratory procedures performed in six different physician practices. The data consisted of 178 subjects representing 92 males and 86 females over the age of 65. DATA SOURCES: Patient data were obtained from the charts housed in a cardiac care center. Subjects, with charts preceding them, were referred by a physician to the cardiac center. The laboratory procedures had been performed previously in the laboratories of the referring physicians. MAIN OUTCOME MEASURES: After accounting for variation between laboratories, mean values of calcium, phosphorus, and alkaline phosphatase were examined to establish if a gender difference existed in patients over the age of 65. A blocked analysis of variance (ANOVA) was conducted at the 0.05 significance level. RESULTS: ANOVA analysis yielded significant gender differences for calcium, phosphorus, and alkaline phosphatase (p < 0.05). Females over the age of 65 consistently showed higher levels than males over the age of 65 for all three variables in five of the six laboratories studied. CONCLUSION: A statistically significant difference was found between the mean levels of men and women 65 years of age and older for calcium, inorganic phosphorus, and alkaline phosphatase. Gender and age are important variables to consider when analyzing and interpreting calcium, phosphorus, and acid phosphatase levels.

Aged↗

[Concept of reliable laboratory test procedures (author's transl)].

Considering the multitude of tests in clinical chemistry and hematology, their low diagnositc sensitivity and specifity, and the low incidence of the diseases in a non selected population it is not possible presently to recommend a general screening procedure based on the definition of the reference, the methodological reproducibility and the diagnostic information of a test procedure it is possible to calculate the number of requests necessary to get any desired number of pathological results. "Tell me how many pathological results you want and I'll tell you how many requests you need". In order to get an optimal diagnostic information for clinical chemistry and hematological tests, it is necessary to increase the prevalence by proper selection of the patients and then to order test procedures specific for the suspected disease.

Age Factors↗

Implementation of laboratory screening procedures on a short-term psychiatric inpatient unit.

A health maintenance screening procedure was done on blood and urine specimens on 636 patients admitted to short term adult psychiatric ward. The data obtained was assessed by laboratory test and by its effect on the subsequent work-up and diagnostic thinking about those patients who had unexpected abnormal findings. The overall incidence of unexpected abnormal tests was low (3.0%). Similarly the incidence of new disease found by these procedures was low (between 2.2% and 8.5%). In no case was an underlying medical cause for the mental disorder for which the patient was admitted detected by the screening procedure. The authors conclude that these routine blood and urine screening tests add very little to the care of psychiatric inpatients.

Adult↗

Laboratory cross-contamination of Mycobacterium tuberculosis: an investigation and analysis of causes and consequences.

BACKGROUND: The misdiagnosis of Mycobacterium tuberculosis infection has many ramifications. These include medical and psychological implications for patients and their families and financial and public health implications for health-care institutions. Microbiology laboratory procedures should minimize the possibility of laboratory cross-contamination of specimens and maximize the ability to recognize a cluster of false-positive cultures. Newer molecular typing methods provide rapid, accurate and effective means of identifying false-positive M. tuberculosis cultures. AIMS: To investigate a cluster of patients with positive M. tuberculosis cultures that were processed in the mycobacteriology laboratory on the same day. METHODS: Five patients' medical records and radiology results were reviewed to determine whether the cases were epidemiologically linked and whether there was clinical suspicion of tuberculosis. Restriction fragment length polymorphism (DNA fingerprinting) was performed using repetitive elements IS6110 and pTBN12. Laboratory processing procedures were analysed. RESULTS: On the basis of DNA fingerprinting using IS6110, the isolates from all five patients were identical. Molecular typing using pTBN12 was performed on four of the five isolates. All four had identical patterns. There was no epidemiological link between the patients. At least three (and probably four) of the five patients were misdiagnosed with tuberculosis. CONCLUSION: Microbiology laboratories should ensure that appropriate methodologies are in place to avoid cross-contamination of specimens. Clinicians need to critically interpret any positive laboratory result, especially in an unlikely clinical setting.

Adult↗

Sensory characteristics of 2-heptanone. Part I. Threshold values, concentration/odour intensity relations, methodological aspects.

The evaluation of threshold values and concentration/odour intensity relations for 2-heptanone has been carried out in two laboratories applying strictly uniform materials, methods and laboratory procedures. The results obtained in aqueous and oil medium are discussed taking into consideration the influence of methods and judges as variability factors. It has been concluded that standardization of the methods and detailed laboratory procedure seem to be critical factors for inter-reproducibility of the results in various sensory laboratories.

Female↗

Review of epidemiological surveys on the prevalence of contamination of healthy cattle with Escherichia coli serogroup O157:H7.

This paper gathers and critically analyses the results of 26 published epidemiological surveys on the prevalence of contamination of cattle with verocytotoxin-producing E. coli (VTEC) serogroup O157:H7. These surveys have been conducted since 1986 on farms in North America (10 studies), on farms in Europe (6 studies) and at slaughterhouses prior to or just after slaughter (7 studies) or after skinning and evisceration (3 studies). The purpose of this review is to understand the first stages of the epidemiology of the infection in animals and humans (the infection process being obscure in many points) and to prepare herd-based control measures to reduce the risk of O157:H7 human infection. The different statistical methods employed in these surveys, as well as the various laboratory screening methods used for detecting positive animals are presented. The observed frequencies of infected animals (animal prevalence) and herds (herd prevalence) are given as a function of localisation, year, type of industry (beef or dairy) and age. From these measured prevalence values, the risk of contamination of ground beef by E. coli O157:H7 in the first stages of the farm-to-fork continuum is assessed. First, we follow the evolution of contamination frequencies from the living animal on-farm to carcasses before transformation. Then, within each set of measurements (i.e., on farm or at slaughterhouse), we identify the effects of the following factors: target population, sampling strategies and laboratory procedures. We argue that the prevalence values inferred from these measurements are very likely underestimated, due to insufficient sampling and not enough sensitive laboratory procedures (one exception being the immunomagnetic bead separation technique). No firm conclusion can be drawn as to the effects of geographical localisation and season. In those surveys, the effect of hygiene level at slaughterhouse on prevalence values is not quantitatively assessed. In addition, there is growing evidence of other sources of E. coli O157:H7 than live cattle in the farm environment, such as feed, water and water-troughs.

Abattoirs↗

Laboratory routines cause animal stress.

Eighty published studies were appraised to document the potential stress associated with three routine laboratory procedures commonly performed on animals: handling, blood collection, and orogastric gavage. We defined handling as any non-invasive manipulation occurring as part of routine husbandry, including lifting an animal and cleaning or moving an animal's cage. Significant changes in physiologic parameters correlated with stress (e.g., serum or plasma concentrations of corticosterone, glucose, growth hormone or prolactin, heart rate, blood pressure, and behavior) were associated with all three procedures in multiple species in the studies we examined. The results of these studies demonstrated that animals responded with rapid, pronounced, and statistically significant elevations in stress-related responses for each of the procedures, although handling elicited variable alterations in immune system responses. Changes from baseline or control measures typically ranged from 20% to 100% or more and lasted at least 30 min or longer. We interpret these findings to indicate that laboratory routines are associated with stress, and that animals do not readily habituate to them. The data suggest that significant fear, stress, and possibly distress are predictable consequences of routine laboratory procedures, and that these phenomena have substantial scientific and humane implications for the use of animals in laboratory research.

Animal Husbandry↗

Biohazards of investigations on the transmissible spongiform encephalopathies.

There is considerable current interest in the agents that cause the spongiform encephalopathies: scrapie, transmissible mink encephalopathy, kuru, and Creutzfeldt-Jakob disease (CJD). The unusual properties of these agents, their elusiveness, and their pathogenicity for humans (in the cases of kuru and CJD) make these agents interesting subjects of investigation but also make imperative a consideration of their potential biohazards in the laboratory. In view of both the potential pathogenicity of these agents and the potential hazards of many laboratory procedures, a series of physical containment levels, each of which corresponds to a range of composite risk factors, are suggested. The estimated composite risk factor used is a function of the potential pathogenicity or relative risk factor of the agent and the potential hazard of a laboratory procedure. The lowest risk factors (1 to 2+) correspond to levels of containment similar to those recommended by the Center for Disease Control for class II microorganisms, while the highest risk factors (5 to 8+) correspond to levels similar to those for class III microorganisms. The use of such a biohazard ranking system aids in a rational approach to selection of equipment and procedures.

Animals↗

An evaluation of elastic tissue staining.

The Special Procedures Laboratory of the Department of Pathology at M.D. Anderson Hospital was concerned with the nationwide shortage of hematoxylin. The amount of this dye required for various staining solutions was calculated to determine thrifty usage. Some solutions required more hematoxylin than was available and prompted the serious investigation of existing techniques and new methods for routine laboratory use. Evaluation of various techniques resulted in a significantly successful modification of Gomori's aldehyde fuchsin technique, which was subsequently adopted as a routine procedure for elastic tissue staining in the Special Procedures Laboratory.

Aldehydes↗

Epidemic of jungle yellow fever in Brazil, 2000: implications of climatic alterations in disease spread.

Seventy-seven human cases of sylvatic yellow fever were reported in Brazil during the period January-June 2000. The first cases were reported 1 week after New Year's day and originated at Chapada dos Veadeiros, a tourist canyon site in Goiás state, near Brasília, the Brazilian capital. The laboratory procedures used for diagnoses included serology with an IgM capture assay and plaque reduction neutralization test, virus isolation in suckling mice and C6/36 cells, and immunohistochemistry. All cases were diagnosed by at least two different laboratory procedures, with the exception of the first three fatal cases, which were diagnosed on the basis of clinical and epidemiological information. The cases were reported in eight Brazilian states as follows: Goiás with 64.9% (50 cases); Amazonas (1); Bahia (10); Distrito Federal (1); Mato Grosso (4); Minas Gerais (2); Pará (1); São Paulo (2); and Tocantins (6). Patient ages were within the following ranges: 13-74 years old (mean 34.3), 64 (84.4%) were male, especially agricultural workers (n = 30), but tourists (n = 11), carpenters (n = 4), fishermen (n = 4), students (n = 3), truck drivers (n = 3), and other people (n = 22) were also sickened. The case fatality rate was 50.6% (39/77). In Bahia state, a serologic survey that was carried out has suggested a symptomatic/asymptomatic coefficient of 1:4. Field studies developed in Distrito Federal, Goiás, and São Paulo states showed that Haemagogus janthinomys was the mosquito species associated with the transmission. A single strain was also obtained from Aedes scapularis in Bahia. Epizootic occurrence (monkey mortality) was observed in 49 municipalities mainly in Goiás state, where 40 municipalities made reports, 21 of which also diagnosed human cases. Data obtained by the National Institute of Meteorology in Brazil showed an increase in temperature and rain in December 1999 and the first 3 months of 2000 in Goiás and surrounding states, which perhaps has contributed to the intense and widespread transmission of the yellow fever virus. The relatively small number of cases probably reflects the extensive use of yellow fever 17D-vaccine during the last 3 years, in which about 45 million doses were used. During the last months of 1999, 16 and 11 yellow fever cases were reported in Tocantins and Goiás states, respectively. It is noteworthy that the last reported autochthonous cases of sylvatic yellow fever in São Paulo and Bahia, both states outside the endemic/enzootic area, had occurred in 1953 and 1948, respectively.

Adolescent↗

Medically useful criteria for analytic performance of laboratory tests.

To establish medically useful guidelines for analytic precision of commonly used clinical laboratory procedures, the authors conducted a mail survey of physicians selected randomly from national lists of specialists. They were asked to review, briefly, outlined clinical problems and select the change in test results that would alter their diagnosis or treatment or prompt further assessment of the patient's condition. The responses were used to calculate goals for laboratory precision that are sufficient to meet the present requirements of the average physician. The medically useful limits were compared with existing performance of laboratories as reported in national proficiency surveys and regional quality control programs. Almost all the common laboratory procedures they studied are being assayed at a precision level adequate for the perceived needs. The authors suggest that, for the more common constituents, further progress in clinical laboratory testing will depend on factors other than the improvement of analytic precision.

Attitude of Health Personnel↗

Cast aluminum denture base.

The laboratory procedures for a cast aluminum base denture have been presented. If an induction casting machine is not available, the "two-oven technique" works well, provided the casting arm is kept spinning manually for 4 minutes after casting. If laboratory procedures are executed precisely and with care, the aluminum base denture can be cast with good results.

Aluminum↗